• Title/Summary/Keyword: membrane surface modification

Search Result 130, Processing Time 0.021 seconds

Membrane Permeation Characteristics and Fouling Control through the Coating of Poly(vinyl alcohol) on PVDF Membrane Surface (PVDF막 표면에 폴리비닐알코올 코팅을 통한 분리막의 투과특성 및 막오염 제어)

  • Jang, Hanna;Kim, In-Chul;Lee, Yongtaek
    • Membrane Journal
    • /
    • v.24 no.4
    • /
    • pp.276-284
    • /
    • 2014
  • In this study, a hydrophobic polyvinylidene fluoride (PVDF) membrane was modified by coating neutral hydrophilic poly(vinyl alcohol). The flux of pure water was measured and then fouling test was conducted with bovin serum albumin (BSA) as model protein foulant. As a result, the experiments showed that pure water flux was decreased but anti-fouling property was significantly enhanced. Pure water flux with increasing molecular weights of the polymer was decreased and fouling resistance was enhanced. Also, Pure water flux with increasing solution concentration was decreased and fouling resistance was enhanced. It is probably due to the increase in hydrophilicity and decrease in roughness of the membrane surface, as revealed by contact angle and AFM analysis.

Nanofiber Membrane based Colorimetric Sensor for Mercury (II) Detection: A Review (나노 섬유 멤브레인을 기반으로 한 수은(II) 색변화 검출 센서에 대한 총설)

  • Bhang, Saeyun;Patel, Rajkumar
    • Membrane Journal
    • /
    • v.31 no.4
    • /
    • pp.241-252
    • /
    • 2021
  • Rapid industrialization with growing population leads to environmental water pollution. Demand in generation of clean water from waste water is ever increasing by scarcity of rain water due to change in weather pattern. Colorimetric detection of heavy metal present in clean water is very simple and effective technique. In this review membrane based colorimetric detection of mercury (II) ions are discussed in details. Membrane such as cellulose, polycaprolactone, chitosan, polysulfone etc., are used as support for metal ion detection. Nanofiber based materials have wide range of applications in energy, environment and biomedical research. Membranes made up of nanofiber consist up plenty of functional groups available in the polymer along with large surface area and high porosity. As a result, it is easy for surface modification and grafting of ligand on the fiber surface enhanced nanoparticles attachment.

Preparation and Properties of Sulfonated Polyvinylchloride (PVC) Membrane for Capacitive Deionization Electrode by Ultra Sonication Modification (초음파 표면개질에 의한 CDI 전극용 술폰화 염화비닐(PVC) 멤브레인의 제조 및 특성)

  • Hwang, Chi Won;Oh, Chang Min;Hwang, Taek Sung
    • Journal of Adhesion and Interface
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 2014
  • Ion exchange membrane is widely used in various fields such as electro dialysis, diffusion dialysis, redox flow battery, fuel cell. PVC cation exchange membrane using ultrasonic modification was prepared by sulfonation reaction in various sulfonation times. Sulfuric acid was used as a sulfonating agent with ultrasonic condition. We've characterized basic structure of sulfonated PVC cation exchange membrane by FT-IR, EDX, water uptake, ion exchange capacity (IEC), electrical resistance (ER), conductivity, ion transport number and surface morphology (SEM). The presence of sulfonic groups in the sulfonated PVC cation exchange membrane was confirmed by FT-IR. The maximum values of water uptake, IEC, electrical resistance and ion transport number were 40.2%, 0.87 meq/g, $35.2{\Omega}{\cdot}cm^2$ and 0.88, respectively.

Characterization of Surface Modified Polysulfone Membranes with Various Fluorine Chemicals

  • Lee, Choong-Sub;Rhim, Ji-Won
    • Korean Membrane Journal
    • /
    • v.4 no.1
    • /
    • pp.20-24
    • /
    • 2002
  • The surface of polysulfone membranes has been modified using the fluorine chemicals, ITFE (2-iodo-1,1,1-trifluoro-ethane F.W.=209.94) and PFPI (1H,1H-pentafluoro-n-propyl iodide F.W.=259.95), and PFI (1H,1H,2H,2H-perfluorohexyl iodide, F.W.=373.99) based on Friedel-Crafts reaction mechanism with varying reaction temperatures, reaction time, and catalysis types. The resulting membranes were characterized through mainly the contact angle measurement and pure water permeability. The smaller reactant shows the larger contact angles. FeBr$_3$ catalyst is more effective than AlCl$_3$. Typically, the PS film treated with ITFE at $25^{\circ}C$ under FeBr$_3$ catalyst showed the contact angle 78.5$^{\circ}C$ which indicated 10% over the value of unreacted PS films. More than 50% of pure water flux 8.0 g/$m^2$hr, reduced at reaction time 10 min relative to the original flux, 3.49 g/$m^2$hr.

Fabrication and Ionic Current Rectification Characteristics of Biomimetic Aluminum Oxide Membrane (생체모방형 비대칭 나노채널을 갖는 산화알루미늄 분리막 제조 및 이온 정류 특성)

  • Jung, Jaehoon;Kim, Jongyoung;Choi, Kiwoon;Lee, Joonho;Kang, Il-suk;Ahn, Chi-won;Cho, Churl-Hee
    • Membrane Journal
    • /
    • v.30 no.3
    • /
    • pp.181-189
    • /
    • 2020
  • In the present study, a biomimetic alumina membrane was fabricated by using selenic acid as an electrolyte to overcome the asymmetry limit of the square pulse anodization process. The prepared membrane has conical channels with a minimum diameter of 10 nm, a maximum diameter of 50 nm, and a length of 5 ㎛. The rectification property was higher than membranes fabricated by sulfuric acid. It showed 2.9 times larger current at +1 V than -1 V. Also, the membrane, which sulfonic acid group was introduced by surface modification, showed 4.2 times larger rectification property at -1 V than +1 V. Theoretical verifications were supported by the numerical analyses of 2D models. The results of the present study present a convenient method to fabricate two type membranes with different rectification properties and are expected to be used to control ion transport.

Low Pressure Hybrid Membrane Processes for Drinking Water Treatment (저압 막여과 혼성공정을 이용한 고도 정수처리)

  • Choo, Kwang-Ho;Chung, Ji-Hyun;Park, Hak-Soon
    • Membrane Journal
    • /
    • v.17 no.3
    • /
    • pp.161-173
    • /
    • 2007
  • Membrane filtration processes are increasingly popular for drinking water treatment that requires high quality of water. Low pressure membrane(LPM) processes such as microfiltration(MF) and ultrafiltration(UF), however, are ineffective in the removal of dissolved organic matter and also membrane fouling is still an important issue to be resolved. High pressure membranes(HPMs) may guarantee better water quality, but at the high energy consumption. Thus, various approaches to combine LPM processes with other physicochemical methods have been recently made to achieve their efficiency to the level comparable to that of HPM processes. In this work, therefore, hybrid processes that coupled MF/UF with coagulation, adsorption, chemical reactions(e.g., chelation and oxidation) are reviewed regarding system design and performance and also membrane surface modifications conducted by grafting and polyelectrolyte multilayer formation were assessed.

Surface Hydrophilization of PVDF Membrane by Thermal Polymerization Lamination Process (열중합 Lamination 공정에 의한 PVDF 분리막의 표면 친수화)

  • Lee, Se-Min;Byun, Young-Jin;Kim, Jin-Ho;Kim, Sung Soo
    • Membrane Journal
    • /
    • v.23 no.3
    • /
    • pp.220-225
    • /
    • 2013
  • Hydrophilic monomers were polymerized for lamination on polyvinylidene fluoride (PVDF) membrane surface for hydrophilization of the membranes. Hydrophilization reduced the contact angle from $95^{\circ}$ to $55^{\circ}$ and enhanced the water flux by 10 times while it reduced the bovine serum albumin (BSA) adsorption amount to 1/4 level. Thermal polymerization process was optimized by examining several operation parameters. Dimethyl oxobuthyl acrylamide (DOAA) showed the best effect due to its better hydrophilicity than others. Increase of amount of monomer enhanced the performance until the optimum concentration of 30 wt%, beyond which excess amount of monomer resulted in homopolymerization to deteriorate the performance. Azobis (isobutyronitrile)(AIBN) initiator has greater activation temperature range than benzoyl peroxide (BPO) and it showed better hydrophilation performance. Two stage lamination process, application of initiator followed by monomer addition, was more effective than one stage process, addition of initiator and monomer at once, which still reduced the contact angle but also reduced the water flux by pore blocking phenomena.

Electrokinetics Evaluation of Poly(styrene-ethylene-butylene-styrene) Based Anion Exchange Membrane (Poly(styrene-ethylene-butylene-styrene)계 고분자 음이온교환막 계면동전위 특성평가)

  • Son, Tae Yang;Yun, Jun Seong;Han, Song I;Nam, Sang Yong
    • Membrane Journal
    • /
    • v.27 no.5
    • /
    • pp.399-405
    • /
    • 2017
  • The zeta potential, called an electrokinetic potential, refers to the potential difference caused by electrodynamic phenomenon, which is a value obtained by quantifying the surface charge property. The zeta potential has been actively studied for membrane fouling, confirmation of modification and substituent confirmation through surface charge analysis. The methods of measurement for zeta potential were developed on the basis of electrophoresis, electrosmosis and streaming potential. Among them, it was known that the streaming potential method was suitable for the flat sheet membrane. So, in this study, aminated poly(styrene-ethylene-butylene-styrene) membranes were prepared by introducing ammonium groups and the streaming potentials of the prepared membranes were measured by using an electrokinetic potential analyzer (SurPASS) and the results were analyzed.

Surface Modification of Glass Chip for Peptide Microarray (펩타이드 Microarray를 위한 유리 칩의 표면 개질)

  • Cho, Hyung-Min;Lim, Chang-Hwan;Neff, Silke;Jungbauer, Alois;Lee, Eun-Kyu
    • KSBB Journal
    • /
    • v.22 no.4
    • /
    • pp.260-264
    • /
    • 2007
  • Peptides are frequently studied as candidates for new drug development. Recently, synthesized peptide library is screened for a certain functionality on a microarray biochip format. In this study, in order to replace the conventional cellulose membrane with glass for a microarray chip substrate for peptide library screening, we modified the glass surface from amines to thiols and covalently immobilized the peptides. Using trypsin-FITC (fluorescein isothiocyanate) conjugate that could specifically bind to a trypsin binding domain consisting of a 7-amino acid peptide, we checked the degree of surface modification. Because of the relatively lower hydrophilicity and reduced surface roughness, the conjugation reaction to the glass required a longer reaction time and a higher temperature. It took approximately 12 hr for the reaction to be completed. From the fluorescence signal intensity, we could differentiate between the target and the control peptides. This difference was confirmed by a separate experiment using QCM. Furthermore, a smaller volume and higher concentration of a spot showed a higher fluorescence intensity. These data would provide the basic conditions for the development of microarray peptide biochips.

Efficient Biotinylation of Nitrocellulose Membrane for Immuno-Filtration Capture Assay

  • Choi, Ki-Bong;Ha, Youn-Chul;Youn, Hee-Ju;Choi, Jung-Do
    • BMB Reports
    • /
    • v.30 no.5
    • /
    • pp.308-314
    • /
    • 1997
  • We investigated biotinylation of nitrocellulose membrane for immuno-filtration capture assay. In order to enhance the efficiency of biotinylation, nitrocellulose membranes were pretreated with several chemicals for the purpose of suitable protein absorption through surface modification. As a signal generating enzyme, urease was used and the concentration of avidin was optimized for the efficient binding kinetics between urease-biotin in liquid phase and biotinylated membrane in solid phase. For effective biotinylation, bovine serum albumin-biotin complexes could be immobilized at a concentration of $370\;{\mu}g$/stick ($4.4\;cm^2$). Among tested chemicals, polylysine (0.25%) showed a significant effect in biotinylation. Polylysine is thought to enhance surface area by extending unbound residues into solution. Time of treatment over 30 min and higher molecular weight of polylysines (58,100 dalton) showed positive effect on the enhancement of biotinylation. The result from this study may be useful for developing a new biosensor and other biofunctional membranes for examining molecular recognition.

  • PDF