• Title/Summary/Keyword: membrane replacement

검색결과 85건 처리시간 0.018초

Effects of membrane orientation on permeate flux performance in a submerged membrane bioreactor

  • Lee, Tsun Ho;Young, Stephanie
    • Membrane and Water Treatment
    • /
    • 제3권3호
    • /
    • pp.141-149
    • /
    • 2012
  • The aeration provided in a Submerged Membrane Bioreactor (SMBR) improves membrane filtration by creating turbulence on the membrane surface and reducing membrane resistance. However, conventional hollow fiber membrane modules are generally packed in a vertical orientation which limits membrane scouring efficiency, especially when aeration is provided in the axial direction. In the present research, 3 innovative hollow-fiber membrane modules, each with a different membrane orientation, were developed to improve membrane scouring efficiency and enhance permeate flux. Pilot testing was performed to investigate the permeate flux versus time relationship over a 7-day period under different intermittent modes. The results indicated that the best module experienced an overall permeate flux decline of 3.3% after 7 days; the other two modules declined by 13.3% and 18.3%. The lower percentage of permeate flux decline indicated that permeate productivity could be sustained for a longer period of time. As a result, the operational costs associated with membrane cleaning and membrane replacement could be reduced over the lifespan of the module.

Thermo-responsive antifouling study of commercial PolyCera® membranes for POME treatment

  • Haan, Teow Yeit;Chean, Loh Wei;Mohammad, Abdul Wahab
    • Membrane and Water Treatment
    • /
    • 제11권2호
    • /
    • pp.97-109
    • /
    • 2020
  • Membrane fouling is the main drawback of membrane technology. Frequent membrane cleaning and membrane replacement are, therefore, required to reduce membrane fouling that causes permeate flux reduction, lower rejection, or higher operating pressure. Studies have proved that the alteration of membrane properties is the key controlling factor in lessening membrane fouling. Among stimuli-responsive membranes, thermo-responsive membrane is the most popular, with a drastic phase transition and swelling-shrinking behavior caused by the temperature change. In this study, the thermo-responsive ability of two commercial membranes, PolyCera® Titan membrane and PolyCera® Hydro membrane, at different temperatures was studied on the antifouling function of the membrane in palm oil mill effluent (POME) treatment. The evaluation of the membrane's thermo-responsive ability was done through three cycles of adsorption (fouling) and desorption (defouling) processes in a membrane filtration process. The experimental result depicted that PolyCera® Hydro membrane had a higher membrane permeability of 67.869 L/㎡.h.bar than PolyCera® Titan membrane at 46.011 L/㎡.h.bar. However, the high membrane permeability of PolyCera® Hydro membrane was compensated with low removal efficiency. PolyCera® Titan membrane with a smaller mean pore size had better rejection performance than PolyCera® Hydro membrane for all tested parameters. On the other hand, PolyCera® Titan membrane had a better hydrodynamic cleaning efficiency than PolyCera® Hydro membrane regardless of the hydrodynamic cleaning temperature. The best hydrodynamic cleaning performed by PolyCera® Titan membrane was at 35℃ with the flux recovery ratio (FRR) of 99.17 ± 1.43%. The excellent thermo-responsive properties of the PolyCera® Titan membrane could eventually reduce the frequency of membrane replacement and lessen the use of chemicals for membrane cleaning. This outstanding exploration helps to provide a solution to the chemical industry and membrane technology bottleneck, which is the membrane fouling, thus reducing the operating cost incurred by the membrane fouling.

Prognosis of closure of large sinus membrane perforations using pedicled buccal fat pads and a resorbable collagen membrane: case series study

  • Kim, Young-Kyun;Yun, Pil-Young;Oh, Ji-Su;Kim, Su-Gwan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제40권4호
    • /
    • pp.188-194
    • /
    • 2014
  • For large membrane perforations that develop during sinus-bone grafting, we performed repairs using a pedicled buccal fat pad and a resorbable collagen membrane simultaneously with the bone graft. This study included eight patients. Postoperative maxillary sinusitis developed in two patients, which we managed with incision and drainage, and antibiotics. Ultimately, six patients received 12 implants, three of which failed (75% success). Implant replacement was performed after the removal of the failed replacement, at which point the prosthetic treatment was considered complete. In all of the six cases that we were able to follow-up with, the sinus-bone graft was healing favorably. We observed that the sinus bone height decreased gradually with time. Based on these case series, we conclude that our procedure of repairing large sinus-membrane perforations with a pedicled buccal fat pad and a collagen membrane is a reliable technique.

에너지절약형 VSA MF Membrane 수처리 시스템 (Effective Water Treatment Process by Hollow Fiber MF Membranes; VAS(Vibrating & Stripping by Air ) Process)

  • 김정학
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1999년도 Energy Saving Membrane Separtion Systems 에너지 절약형 막분리 시스템
    • /
    • pp.93-116
    • /
    • 1999
  • MF membrane element was specially designed for water purification and VSA process which can solve the fouling problem. Especially VSA process is developed for the SK Chemicals' asymmetric microfiltration hollow fiber membranes. In case of outside-to-in filtration process, MF membrane element showed the excellent flux stability caused by cleaning ability of VSA process . Simultaneous back-washing with VSA consideratbly enhances cleaning efficiency. From the result the possibility of the replacement of chemical coagulation and sand filtration process with newly developed VSA process was revealed.

  • PDF

EFFECTIVE WATER TREATMENT PROCESS BY HOLLOW FIBER MEMBRANES : VAS (VIBRATING & STRIPPING BY AIR) PROCESS

  • Kim, Jeong-Hak
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1999년도 The 7th Summer Workshop of the Membrane Society of Korea
    • /
    • pp.63-66
    • /
    • 1999
  • MF membrane element was specially designed for water purification and VSA process which can solve the fouling problem. Especially VSA process is developed for the SK Chemical's asymmetric microfiltration hollow fiber membranes. In case of outside-to-in filtration process, MF membrane element showed the excellent flux stability caused by cleaning ability of VSA process. Simultaneous back- washing with VSA considerably enhances cleaning efficiency. Form the result, the possibility of the replacement of chemical coagulation and sand filtration process with newly developed VSA process was revealed.

  • PDF

에크모와 신대체요법을 이용하여 치료한 칼슘채널차단제, 안지오텐신 수용체 차단제, 메트포민 중독 환자 증례 (Extracorporeal Membrane Oxygenation and Continuous Renal Replacement Therapy for Treatment of Calcium Channel Blockers, Angiotensin II Receptor Blockers, and Metformin Overdose)

  • 정재한;선경훈;박용진;김선표
    • 대한임상독성학회지
    • /
    • 제16권2호
    • /
    • pp.165-171
    • /
    • 2018
  • An overdose of antihypertensive agents, such calcium channel blockers (CCBs) and angiotensin II receptor blocker (ARBs), and the antihyperglycemic agent, metformin, leads to hypotension and lactic acidosis, respectively. A 40-year-old hypertensive and diabetic man with hyperlipidemia and a weight of 110 kg presented to the emergency room with vomiting, dizziness, and hypotension following an attempted drug overdose suicide with combined CCBs, ARBs, 3-hydroxy-3-methylglutaryl-coemzyme A reductase inhibitors, and metformins. A conventional medical treatment initially administered proved ineffective. The treatment was then changed to simultaneous extracorporeal membrane oxygenation (ECMO) and continuous renal replacement therapy (CRRT), which was effective. This shows that simultaneous ECMO and CRRT can be an effective treatment protocol in cases of ineffective conventional medical therapy for hypotension and lactic acidosis due to an overdose of antihypertensive agents and metformin, respectively.

Mitral Valve Replacement with a Pulmonary Autograft in an Infant

  • Jeong, Yong Ho;Yun, Tae-Jin
    • Journal of Chest Surgery
    • /
    • 제51권2호
    • /
    • pp.149-152
    • /
    • 2018
  • A 76-day-old infant weighing 3.4 kg was referred for surgical intervention for severe mitral valve stenoinsufficiency caused by leaflet fibrosis and calcification. He had ex perienced a cerebral infarction in the left middle cerebral artery territory, which was deemed attributable to an embolism of a calcified particle from the dysmorphic mitral valve. Because mitral valve replacement using a prosthetic valve was not feasible in this small baby, mitral valve replacement with a pulmonary autograft was performed. After a brief period of extracorporeal membrane oxygenation (ECMO) support, he was weaned from ECMO and was discharged home without further cardiovascular complications.

분리된 막성 대동맥 판막하 협착증;1례 보고 (Discrete Membranous Subvalvulr Aortic Stenosis - A Case -)

  • 오중환
    • Journal of Chest Surgery
    • /
    • 제25권7호
    • /
    • pp.739-744
    • /
    • 1992
  • Discrete membranous subaortic stenosis[DMSS] is one of the subtype of congenital left ventricular outflow obstruction and can be associated with aortic regurgitation, infective endocarditis, ventricular obstruction. DMSS should be removed early, when diagnosed, and completely before secondary myocardial changes occur. Recently we experienced a case of DMSS with aortic regurgitation, and its left ventricular outflow tract obstruction[LVOTO] peak systolic gradient was 10lmmHg. Resection of membrane and aortic valve replacement is adequet for LVOTO and postoperative pressure gradient was 26mmHg. Postoperative echocardiogram shows no obstuctive membrane and well functioning aortic valve.

  • PDF

Analysis of the Effect of Renal Replacement Therapy: In the Prolonged Extracorporeal Membrane Oxygenation Patients

  • Park, Hyun-Seok;Cho, Seong-Joon;Ryu, Se-Min;Park, Sung-Min;Kim, Ki-Hwan;Lim, Sun-Hye;Shin, Hee Kon
    • Journal of Chest Surgery
    • /
    • 제47권4호
    • /
    • pp.373-377
    • /
    • 2014
  • Background: This paper aimed to verify the effects of renal replacement therapy on changing the levels of serum creatinine for different veno-arterial and veno-venous configurations in prolonged extracorporeal membrane oxygenation (ECMO) patients. Methods: The subjects were chosen 71 patients who had undergone more than 1,440 minutes (24 hours) of the therapy from among 117 patients who had undergone ECMO insertion between January 2008 and December 2012. The patients were separated into the veno-arterial configuration group I (51 patients) and the veno-venous configuration group II (20 patients). The difference in the level of serum creatinine (${\Delta}Cr$) between before or just after ECMO insertion ($Cr_I$) and the level when the pump time was between 2,880 and 4,320 minutes ($Cr_F$) was checked (${\Delta}Cr=Cr_F-Cr_I$), and the average ${\Delta}Cr$ for each group was compared using a Student t-test at the confidence interval (CI) of 95%. Results: The change in the level of serum creatinine was an increase of 0.341 mg/dL (${\sigma}$=0.9202) for group I and a decrease of 0.120 mg/dL (${\sigma}$=1.5292) for group II. The change was significantly high for group I (p=0.011, CI=95%). Meanwhile, within group I, when renal replacement therapy was not done, there was a significant increase in the level of serum creatinine (p=0.009, CI=95%). Conclusion: For ECMO insertion patients whose pump time was more than 1,440 minutes, there was a significant change in the level of serum creatinine when renal replacement therapy was not done, for the veno-arterial configuration of group I.