DOI QR코드

DOI QR Code

Mitral Valve Replacement with a Pulmonary Autograft in an Infant

  • Jeong, Yong Ho (Division of Pediatric Cardiac Surgery, Asan Medical Center, University of Ulsan College of Medicine) ;
  • Yun, Tae-Jin (Division of Pediatric Cardiac Surgery, Asan Medical Center, University of Ulsan College of Medicine)
  • Received : 2017.08.25
  • Accepted : 2017.10.12
  • Published : 2018.04.05

Abstract

A 76-day-old infant weighing 3.4 kg was referred for surgical intervention for severe mitral valve stenoinsufficiency caused by leaflet fibrosis and calcification. He had ex perienced a cerebral infarction in the left middle cerebral artery territory, which was deemed attributable to an embolism of a calcified particle from the dysmorphic mitral valve. Because mitral valve replacement using a prosthetic valve was not feasible in this small baby, mitral valve replacement with a pulmonary autograft was performed. After a brief period of extracorporeal membrane oxygenation (ECMO) support, he was weaned from ECMO and was discharged home without further cardiovascular complications.

Keywords

References

  1. Beierlein W, Becker V, Yates R, et al. Long-term follow-up after mitral valve replacement in childhood: poor event-free survival in the young child. Eur J Cardiothorac Surg 2007;31:860-5. https://doi.org/10.1016/j.ejcts.2007.02.006
  2. Ross DN, Kabbani S. Mitral valve replacement with a pulmonary autograft: the mitral top hat. J Heart Valve Dis 1997;6:542-5.
  3. Kabbani S, Jamil H, Nabhani F, et al. Analysis of 92 mitral pulmonary autograft replacement (Ross II) operations. J Thorac Cardiovasc Surg 2007;134:902-8. https://doi.org/10.1016/j.jtcvs.2007.05.056
  4. Kawahito T, Egawa Y, Yoshida H, et al. Experience of mitral valve replacement using a pulmonary autograft (Ross II operation) in an infant: report of a case. Kyobu Geka 2015;68:523-7.
  5. Kabbani SS, Sabbagh NA, Kudsi AY, Nabhani F, Jamil H. Update on the mitral pulmonary autograft. Asian Cardiovasc Thorac Ann 2011;19:253-9. https://doi.org/10.1177/0218492311409631
  6. Yamagishi M, Shuntoh K, Matsushita T, et al. Mitral valve replacement by a Gore-Tex reinforced pulmonary autograft in a child. J Thorac Cardiovasc Surg 2003;126:1218-9. https://doi.org/10.1016/S0022-5223(03)00785-2
  7. Pace Napoleone C, Oppido G, Angeli E, Giardini A, Gargiulo G. Ross-kabbani operation in an infant with mitral valve dysplasia. Cardiol Res Pract 2009;2009:593659.
  8. Lee JW, Kim KI, Jung SH, Choi E, Song MG. Mitral valve replacement with a pulmonic autograft. Korean J Thorac Cardiovasc Surg 2001;34:361-4.

Cited by

  1. Mitral valve replacement with a pulmonary autograft: long-term follow-up in an infant vol.28, pp.5, 2018, https://doi.org/10.1093/icvts/ivy322
  2. Don’t go breaking my heart valve: historical review of mitral valve replacement vol.17, pp.5, 2018, https://doi.org/10.2217/fca-2020-0136