• 제목/요약/키워드: membrane performance

검색결과 1,784건 처리시간 0.024초

Exploration of shockwaves on polymeric membrane physical properties and performance

  • Lakshmi, D. Shanthana;Saxena, Mayank;Ekambaram, Shivakarthik;Sivaraman, Bhalamurugan
    • Membrane and Water Treatment
    • /
    • 제12권1호
    • /
    • pp.43-49
    • /
    • 2021
  • The Commercial polymeric membranes like Polysulfone (PSF), Polyvinylidene difluoride (PVDF) and Polyacrylonitrile (PAN) which are an integral part of water purification investigation were chosen for the shockwave (SW) exposure experiment. These membranes were prepared by blending polymer (wt. %) / DMF (solvent) followed by phase-inversion casting technique. Shockwaves are generated by using Reddy Tube lab module (Table-top Shocktube) with range of pressure (1.5, 2.5 and 5 bar). Understanding the changes in membrane before and after shock wave treatment by parameters, i.e., pure water flux (PWF), rejection (%), porosity, surface roughness (AFM), morphology (SEM) and contact angle which can significantly affect the membrane's performance. Flux values PSf membranes shows increase, 465 (pristine) to 524 (1.5wt%) LMH at 50 Psi pressure and similar enhancement was observed at 100Psi (625 to 696 LMH). Porosity also shows improvement from 73.6% to 76.84% for 15wt% PSf membranes. It was observed that membranes made of polymers such as PAN and PSF (of high w/w %) exhibits some resistance against shockwaves impact and are stable compared to other membranes. Shockwave pressure of up to 1.5 bar was sufficient enough to change properties which are crucial for performance. Membranes exposed to a maximum pressure of 5 bar completely scratched the surface and with minimum pressure of 1.5bar is optimum enough to improve the water flux and other parameters. Initial results proved that SW may be suitable alternative route to minimize/control membrane fouling and improve efficiency.

Treatment of Industrial Wastewater with High Concentration of Hydrocarbons Using Membrane Reactors

  • Bienati, B.;Bottino, A.;Comite, A.;Ferrari, F.;Firpo, R.;Capannelli, G.
    • 멤브레인
    • /
    • 제17권2호
    • /
    • pp.112-117
    • /
    • 2007
  • The application of membrane bioreactors for the depuration of wastewater coming from the washing of mineral oil storage tanks is described. Microfiltration hollow-fibre membranes were used in the submerged configuration. Filtration tests were carried out with a biomass concentration of about 15 g/L in order to assess the critical flux of the hollow fibre membrane used. Then particular care was taken in carrying out the performance runs in the sub-critical flux region. The reactor performance was very high, with removal efficiencies ranging between 93% and 97% also when the concentration of hydrocarbon was very high. Some kinetic parameters for the COD and the hydrocarbon removal were estimated.

탄화수소계 전해질막과 저온 전사법을 이용한 DMFC용 MEA 제조 (Fabrication of Hydrocarbon Membrane based DMFC MEAs with Low Temperature Decal Method)

  • ;;하흥용;김수길
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.415-417
    • /
    • 2009
  • A low temperature decal (LTD) transfer method is tried to fabricated hydrocarbon (HC) membrane based MEA. Sandwiched structures of outer ionomer/catalyst/carbon coating/substrate, which had been developed for Nafion membrane, are used for transfer of catalyst to the HC membrane. Performances of the HC MEA before and after 500hr continuous operation are compared and it is found that a severe delamination occurs at the interface between the HC membrane and the catalyst layer, which is the main reason of the low performance and its degradation. The delamination is due probably to the different nature of HC membrane to the Nafion ionomer. A substitutional method, therefore, is suggested to overcome this. In such a way, the outer ionomer process is removed and the low transfer rate of catalyst by skipping the ionomer process is compensated with optimization of other process variables such as transfer time or temperature. The resulting performance is superior to the original LTD method, which can be explained in terms of low resistive components both in ohmic and kinetic.

  • PDF

Performance and antifouling properties of PVDF/PVP and PSf membranes in MBR: A comparative study

  • Hazrati, Hossein;Karimi, Naser;Jafarzadeh, Yoones
    • Membrane and Water Treatment
    • /
    • 제11권2호
    • /
    • pp.159-166
    • /
    • 2020
  • In this study, the performance and antifouling properties of polysulfone (PSf) and polyvinylidene fluoride/polyvinylpyrrolidone (PVDF/PVP) membranes in a membrane bioreactor (MBR) were investigated. The membranes were prepared via phase inversion method, and then characterized by a set of analyses including contact angle, porosity and water flux and applied in a lab-scale MBR system. Soluble microbial product (SMP), extracellular polymeric substance (EPS), FTIR, gel permission chromatography (GPC) and particle size distribution (PSD) analyses were also carried out for MBR system. The results showed that the MBR with PSf membrane had higher hydrophobic organic compounds which resulted in formation of larger flocs in MBR. However, in this MBR had high compressibility coefficient of cake layer was higher (n=0.91) compared to MBR with PVDF/PVP membrane (n=0.8); hence, the fouling was more profound. GPC analysis revealed that compounds with molecular weight lower than 2 kDa are more formed on PSf membrane more than PVDF/PVP membrane. The results of FTIR analysis confirmed the presence of polysaccharide and protein compounds on the cake layer of both membranes which was in good agreement with EPS analysis. In addition, the results showed that their concentration was higher for the cake on PSf membrane.

Performance of fouled NF membrane as used for textile dyeing wastewater

  • Abdel-Fatah, Mona A.;Khater, E.M.H.;Hafez, A.I.;Shaaban, A.F.
    • Membrane and Water Treatment
    • /
    • 제11권2호
    • /
    • pp.111-121
    • /
    • 2020
  • The fouling of Nanofiltration membrane (NF) was examined using wastewater containing reactive black dye RB5 of 1500 Pt/Co color concentrations with 16890 mg/l TDS collected from El-alamia Company for Dying and Weaving in Egypt. The NF-unit was operated at constant pressure of 10 bars, temperature of 25℃, and flowrate of 420 L/min. SEM, EDX, and FTIR were used for fouling characterization. Using the ROIFA-4 program, the total inorganic fouling load was 1.07 mM/kg present as 49.3% Carbonates, 10.1% Sulfates, 37.2% Silicates, 37.2% Phosphates, and 0.93% Iron oxides. The permeate flux, recovery, salt rejection and mass transfer coefficients of the dye molecules were reduced significantly after fouling. The results clearly demonstrate that the fouling had detrimental effect on membrane performance in dye removal, as indicated by a sharp decrease in permeate flux and dye recovery 68%. The dye mass transfer coefficient was dropped dramatically by 34%, and the salt permeability increased by 14%. In this study, all the properties of the membrane used and the fouling that caused its poor condition are identified. Another study was conducted to regeneration fouled membrane again by chemical methods in another article (Abdel-Fatah et al. 2017).

Membrane behavior of bentonite-amended compacted clay towards Zn(II) and Pb(II)

  • Tang, Qiang;Katsumi, Takeshi;Inui, Toru;Li, Zhenze
    • Membrane and Water Treatment
    • /
    • 제6권5호
    • /
    • pp.393-409
    • /
    • 2015
  • Zinc and lead pollution are public environmental issues that have attracted lots of attention for a long time. Landfill leachate contains heavy metals, such as Zn(II) and Pb(II), which are usually related to the pollution of groundwater, especially in developing countries. Bentonite has been proven to be effective in enhancing the membrane property of clay, by which landfill liners can have better barrier performance towards the migration of contaminants. In this study, 5% sodium bentonite amended with locally available Fukakusa clay was utilized to evaluate the membrane behavior towards the heavy metals zinc and lead. The chemico-osmotic efficiency coefficient, ${\omega}$, was obtained through Zn(II) and Pb(II) solutions with different concentrations of 0.5, 1, 5, 10, and 50 mM. According to the results, ${\omega}$ continually decreased as the Zn(II) and Pb(II) concentrations increased, which is consistent with the Gouy-Chapman theory. Compared to normal inorganic ions, the membrane behavior towards heavy metal ions was lower. The migration of heavy metal ions was not observed based on experimental results, which can be attributed to the adsorption or ion exchange reaction. The mechanisms of the membrane performance change were discussed with the assistance of XRD patterns, free swelling results, XRF results, and SEM images.

청각 구조를 이용한 잡음 음성의 인식 성능 향상 (Performance Improvement of Speech Recognizer in Noisy Environments Based on Auditory Modeling)

  • 정호영;김도영;은종관;이수영
    • 한국음향학회지
    • /
    • 제14권5호
    • /
    • pp.51-57
    • /
    • 1995
  • 본 논문에서는 청각 모델을 기초로 잡음에 강한 음성 특징 추출을 연구하였다. 청각모델은 basilar membrane 모델, 섬모세포(hair cell) 모델과 스펙트럼 출력단으로 구성하였다. Basilar membrane 모델은 음파의 진동에 따른 전달 특성을 묘사한 것으로 대역 통과 필터의 열로 나타난다. 섬모 세포 모델은 basilar membrane의 진동에 의한 신경 물질로의 변환을 나타낸다. 이것은 입력의 상대적인 값에 크게 반응하는 adaptation 기능을 이용하게 되며, 잡음 제거에 중요한 역할을 하게 된다. 스펙트럼 출력 단은 각 채널의 평균 firing rate를 이용하여 mean rate spectrum을 형성한다. 그리고 mean rate spectrum을 이용하여 특징 벡터를 추출하였다. 실험 결과는 청각 구조에 기초한 특징 추출이 다른 특징 추출 방법에 비해 잡음에서 더 향상된 성능을 가짐을 보였다.

  • PDF

Performance improvement of countercurrent-flow membrane gas absorption in a hollow fiber gas-liquid membrane contactor

  • Ho, Chii-Dong;Sung, Yun-Jen;Chen, Wei-Ting;Tsai, Feng-Chi
    • Membrane and Water Treatment
    • /
    • 제8권1호
    • /
    • pp.35-50
    • /
    • 2017
  • The theoretical membrane gas absorption module treatments in a hollow fiber gas-liquid membrane contactor using Happel's free surface model were obtained under countercurrent-flow operations. The analytical solutions were obtained using the separated variable method with an orthogonal expansion technique extended in power series. The $CO_2$ concentration in the liquid absorbent, total absorption rate and absorption efficiency were calculated theoretically and experimentally with the liquid absorbent flow rate, gas feed flow rate and initial $CO_2$ concentration in the gas feed as parameters. The improvements in device performance under countercurrent-flow operations to increase the absorption efficiency in a carbon dioxide and nitrogen gas feed mixture using a pure water liquid absorbent were achieved and compared with those in the concurrent-flow operation. Both good qualitative and quantitative agreements were achieved between the experimental results and theoretical predictions for countercurrent flow in a hollow fiber gas-liquid membrane contactor with accuracy of $6.62{\times}10^{-2}{\leq}E{\leq}8.98{\times}10^{-2}$.

Pre-treatment of textile wastewaters containing Chrysophenine using hybrid membranes

  • lehi, Arash Yunessnia;Mousavirad, Seyed Jalaleddin;Akbari, Ahmad
    • Membrane and Water Treatment
    • /
    • 제8권1호
    • /
    • pp.89-112
    • /
    • 2017
  • Dyeing wastewaters are the most problematic wastewater in textile industries and also, growing amounts of waste fibers in carpet industries have concerned environmental specialists. Among different treatment methods, membrane filtration processes as energy-efficient and compatible way, were utilized for several individual problems. In this research, novel hybrid membranes were prepared by waste fibers of mechanical carpets as useful resource of membrane matrix and industrial graphite powder as filler to eliminate Chrysophenine GX from dyeing wastewater. These membranes were expected to be utilized for first stage of hybrid membrane filtration process including (adsorption-ultrafiltration) and nanofiltration in Kashan Textile Company. For scaling of membrane filtration process, fouling mechanism of these membranes were recognized and explained by the use of genetic algorithm, as well. The graphite increased rejection and diminished permeate flux at low concentration but in high concentration, the performance was significantly worsened. Among all hybrid membranes, 18% wt. waste fibers-1% wt. graphite membrane had the best performance and minimum fouling. The maximum pore size of this optimum membrane was ranged from 16.10 to 18.72 nm.

산성용액 노출 시 폴리아마이드 분리막의 표면성질 및 투과성능 변화에 관한 총설 (Review on Changes in Surface Properties and Performance of Polyamide Membranes when Exposed to Acidic Solutions)

  • 이형개;후엔티탄다오;강우석;권영남
    • 멤브레인
    • /
    • 제30권5호
    • /
    • pp.283-292
    • /
    • 2020
  • 산업분야에서는 다양한 용액을 대상으로 분리, 정제, 농축 등의 공정이 필요하며, 분리막이 그 역할을 잘 수행해 오고 있다. 반면, 처리 대상 용액이 강산을 함유하고 있는 경우, 대부분의 분리막은 산에 취약하기 때문에 사용이 제한적일 수밖에 없다. 현재 내산성 분리막으로 상용화 되고 있는 분리막은 투과속도가 낮은 문제점을 갖고 있다. 이에, 투과속도가 높은 폴리아마이드 분리막에 내산성을 부여하기 위한 접근 방법을 모색하기 위한 기초 자료로 본 총설에서는 폴리아마이드 분리막이 산성 용액 노출 시 표면성질 및 투과특성이 변화하는 원인과 기작에 대해 살펴보고자 한다.