• Title/Summary/Keyword: membrane penetration

Search Result 136, Processing Time 0.026 seconds

Correction for Membrane Penetration Effect during Isotropic Unloading and Undrained Cyclic Shear Process (등방제하과정과 반복전단과정에서의 멤브레인 관입량 및 보정식에 대한 실험적 고찰)

  • Kwon, Youngcheul;Bae, Wooseok;Oh, Sewook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.3C
    • /
    • pp.201-207
    • /
    • 2006
  • Soil tests are generally conducted using a membrane to measure a pore water pressure. However, it has also been recognized that the membrane penetrates into the specimen by the change of the confining pressure, and it results in the erroneous measurement in the pore water pressure and the volumetric strain. This study examined the effectiveness of the correction equation of the membrane penetration on the basis of the experimental data acquired during the isotropic unloading and the cyclic shear process using the hollow cylindrical shear test equipment. The results showed that the membrane penetration by the correction equation could be overestimated when the mean effective stress was lower than 20kPa in this study. The limitations originated from the sudden increase near the zero effective stress, and in order to prevent the overestimation in low effective stress condition, the use of the constant a was proposed in this study. Furthermore, the correction equation for the membrane penetration had to be applied carefully when the initial relative density was high and the density changes were occurred by the relocation of the soil particle by the liquefaction.

The penetration site of local anesthetics into liposomal membrane

  • Han, Suk-Kyu;Bae, Song-Ja;Il-Yun;Kim, Nam-Hong
    • Archives of Pharmacal Research
    • /
    • v.8 no.4
    • /
    • pp.205-211
    • /
    • 1985
  • The distribution of local anesthetics between the hydrocarbone interior and surface area of the lipid bilayer of liposomal membrane was calculated employeg fluorescence probe technique. The quenching of fluorescence probe technique. The quenching of fluorescence probe technique. The quenching of fluorescence of 12-(9-anthroyl) stearic acid and N-octadecyl naphthyl-2-amini-6-sulfonic acid by the local anesthetics in liposomal system was used to calculate the distribution. The Stern-Volmer equation was modified and employed for this calculation. The results showed that procaine hydrocloride and benzocaine were mainly distributed on the surface area of the lipid bilayer of the liposoal membrane, while tetracaine hydrochloride penetrated effectively into the hydrocarbon interior and showed even distribution in the lipid bilayer.

  • PDF

Influence of Lap Weld Shapes on Shear Strength by Plasma Arc Welding of SUS 304L (플라즈마 아크 용접에 의한 SUS 304L Lap 용접부형상이 강도에 미치는 영향)

  • 문종현;윤동렬;김동철;이동우;장태원
    • Proceedings of the KWS Conference
    • /
    • 2004.05a
    • /
    • pp.129-130
    • /
    • 2004
  • The stainless steel sheet which is one of primary barrier components for membrane on LNG ship is ordinarily welded by either TIG or PAW. The weld shapes of acceptant tolerance for membrane construction are scripted by G.T.T.(Gaztransport & Technigaz)‘s rules such as penetration depth, weld throat and weld length etc. This paper presents relationship between weld metal shear strength and weld penetration formed with plasma arc welding. The results show penetration depth is not decisive factor on shear strength, but weld throat and length.

  • PDF

A Study on Flow Properties of Semisolid Dosage Forms

  • Shon, Sung-Gil;Lee, Chi-Ho
    • Archives of Pharmacal Research
    • /
    • v.19 no.3
    • /
    • pp.183-190
    • /
    • 1996
  • There are a wide variety of semi-solid ointments used for healing the skin diseases, whose therapeutic and skin penetration abililties may greatly differ from one another depending on the compositions of ointment vehicles. A computer optimization technique was applied to obtain the optimum formula of o/w type ointment giving the in vitro maximum absorption rate through hairless rat skin membrane. Some of the formulations were selected to find out a relationship between skin penetration of ointment and its Theological characteristics. The experimental value of absorption rate obtained from the ointment by optimum formula agreed well with the theoretical value obtained from a polynomial regression analysis, Three kinds of ointments selected among 15 formulations were obtained with a concentric cylinder type rheometer (Model; Rheolab SM-HM Physica, Germany) at 20, 30, 40 and $50^{\circ}C$ for rheograms of rhelolgical properties of o/w type ointments. As the temperature was raised, all products showed a decrease in both shear stress and yield values. The higher skin penetration, the lower shear stress showed.

  • PDF

Studies on Salmonella enteritidis Contamination in Chicken Egg using Confocal Scanning Laser Microscopy (Confocal Scanning Laser Microscopy 를 이용한 계란에서의 Salmonella enteritidis 오염 연구)

  • Jang, Keum-Il;Park, Jong-Hyun;Kim, Kwang-Yup
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.3
    • /
    • pp.771-777
    • /
    • 1999
  • The structural function of three egg membrane layers and cuticle layer, and the effectiveness of 5 film coatings (chitosan, starch, gelatin, dextrin, mineral oil) on the prevention of Salmonella enteritidis penetration was investigated using confocal scanning laser microscopy (CSLM). Diameters of outer membrane fibers, inner membrane fibers and limiting membrane particles in eggshell were $1.5{\sim}7.2$, $0.8{\sim}2.0$ and $0.1{\sim}1.4\;{\mu}m$, respectively and average thicknesses were 10.0, 3.5, $3.6\;{\mu}m$, respectively. Average thickness of cuticle layer was $6.0\;{\mu}m$ and cuticle layer covered $40{\sim}80%$ of total eggshell surface. Average coating films thickness for chitosan, starch, gelatin, dextrin and mineral oil were 2.2, 2.5, 3.9, 3.6 and $5.0\;{\mu}m$, respectively. After immersion process eggshell surface was almost completely covered by coating films. Chitosan coating was most effective among 5 film coatings in inhibiting growth of Salmonella enteritidis. Penetration process of Salmonella enteritidis through eggshell was investigated by multicolor imaging using CSLM and plate counting. Cuticle layer was the most important structure in blocking the penetration. Among 5 film coatings, chitosan showed the best and similar effectiveness with cuticle layer.

  • PDF

Salt damage resistance of mortar substrate coated by the urethane and acrylic waterproofing membranes (우레탄계와 아크릴계 도막 방수재가 도포된 바탕 모르타르의 염해 저항성 평가)

  • Lee, Jun;Miyauchi, Hiroyuki;Koo, Kyung-Mo;Choe, Gyeong-Cheol;Miyauchi, Kaori;Kim, Gyu-Yong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.329-331
    • /
    • 2013
  • The salt damage resistance of waterproofing membrane was evaluated on the cracked mortar substrate. The types of specimens are urethane, acrylic waterproofing membrane, and no coating mortar substrate. After these specimens were cured by water curing for 4 weeks, they were cured by atmospheric curing at 20±2Co for 8 weeks. The salt water immersion test was carried out by following KS F 2737, and the penetration depth of chloride ion into substrate was measured in 1, 4, 8, and 13 weeks. As a result, in the case of non coating specimen, the chloride ion penetrated within one week. In the coated specimens, a regardless of the membrane type, the chloride ion did not penetrate during 13 weeks-tests on condition that the cracked width of substrate is less than 0.3mm. Also, the penetration speeds of the coated specimens were lower than that of non coating specimen. Therefore, our results reached a conclusion that waterproofing membrane has high salt damage resistance.

  • PDF

Analytical Structural Integrity for Welding Part at Piping Penetration under Seismic Loads (지진하중이 적용되는 배관 관통부의 용접에 대한 구조 건전성 해석)

  • Choi, Heon-Oh;Jung, Hoon-Hyung;Kim, Chae-Sil
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.1
    • /
    • pp.23-29
    • /
    • 2014
  • The purpose of this paper is to assess the structural integrity of piping penetrations for nuclear power plants. A piping qualification analysis describes loads due to deadweight, pressure difference acts normal to the plate, thermal transients, and earthquakes, among other events, on piping penetrations that have been modeled as an anchor. Amodel was analyzed using a commercial finite element program. Apiping penetration analysis model was constructed with an assembly of pipe, head fittings and sleeves. Normally, the design load, thus obtained, will consist of three moments and three forces, referred to a Cartesian coordinate system. When comparing the stress analysis results from each required cutting position, the general membrane stress intensities and local membrane plus bending stress intensities during a structural evaluation cannot exceed the allowable amount of stress for the design loads. Therefore, the piping penetration design satisfies the code requirements.

Development of Antibacterial Hood and Filter for Medical Powered Air Purifying Respirators (PAPR) (의료용 전동공기청정호흡기(PAPR)용 항균성 후드 및 필터 개발)

  • Eunjoo Koh;Nahyun Cho;Yong Taek Lee
    • Membrane Journal
    • /
    • v.33 no.6
    • /
    • pp.398-408
    • /
    • 2023
  • This work developed a hood and filter for antibacterial protective clothing for medical powered air purifying respirators (PAPR) that can be used in medical settings and quarantine against infectious diseases such as Zika virus, Middle East respiratory syndrome (MERS), and coronavirus disease-19 (COVID-19). The hood material of the protective clothing was made of polypropylene spunlace nonwoven fabric (SFS) was used for withstand wind pressure and external physcial pressure. Forthermore, in order to reduce the user's risk of infection, phytoncide-based materials were used on the outer-surface of the hood to achieve a 99.9% antibacterial effect, and the inner-surface were treated with hydro-philic materials to improve absorbency by 25%. In addition to evaluating the artificial blood penetration resistance, dry mi-croorganism penetration resistance, wet bacteria penetration resistance, and bacteriophage penetration resistance required for medical protective clothing hoods, it received a passing evaluation of levels 2-6. Meanwhile, as a result of evaluating the performance of the antibacterial treated spunlace high efficiency particulate air (HEPA) filter, excellent antibacterial properties, dust removal rate, and differential pressure effect were confirmed. All performance evaluations were conducted by an accredited certification body in accordance with the medical PAPR certification standards.

A Study on the Penetration Depth Measurement Methods of Inorganic Waterproofing Agent for Concrete (콘크리트용 무기계 방수제의 침투깊이 측정방법에 관한 연구)

  • Choi, Yun-Wang;Oh, Sung-Rok;Park, Man-Seok;Kim, Kyung-Hwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.3
    • /
    • pp.116-124
    • /
    • 2014
  • Penetration depth of inorganic waterproofing agent is difficult to assess quantitatively because inorganic waterproofing agent for concrete is not an internal waterproof membrane. However, evaluation of penetration depth of inorganic waterproofing agent is one of the most important evaluation index to secure efficiency in a consistent penetration. Therefore, this paper was proposed penetration depth measurement method of inorganic waterproofing agent for concrete and the penetration depth of the conventional inorganic waterproofing agent have been evaluated through the proposed penetration depth measurement method. As a result of test, the measured penetration depth throught the proposed penetration depth measurement method of inorganic waterproofing agent showed that more than 90% reliability.

Moisture Absorption Characteristics of Pt/Nafion Membrane for PEMFC Prepared by a Drying Process (건식법에 의해 제조한 PEMFC용 Pt/나피온 막의 흡습 특성)

  • Lee, Jae-Young;Lee, Hong-Ki
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.4
    • /
    • pp.310-315
    • /
    • 2012
  • A simple drying process was developed for the preparation of a Pt/Nafion self-humidifying membrane to be used for a proton-exchange membrane fuel cell (PEMFC). Platinum (II) bis (acetylacetonate), $Pt(acac)_2$ was sublimed, penetrated into the surface of a Nafion film and then reduced to Pt nanoparticles simultaneously without any support of a reducing agent in a glass reactor at $180^{\circ}C$ for 15 min. The process was carried out in $N_2$ atmosphere to prevent the oxidation of Pt nanoparticles at high temperature. The morphology and distribution of the Pt nanoparticles were observed by transmission electron microscopy (TEM) and energy dispersive spectroscopy (EDS), and we found that the average Pt particle size was ca. 3.7 nm, the penetration depth was ca. $17{\mu}m$. Almost all Pt nanoparticles were formed just beneath the surface and the number density decreased rapidly as the penetration depth increased. To estimate water absorption characteristics of the Nafion membranes, water uptake at an isothermal condition was measured by dynamic vapor sorption (DVS), and it was found that water uptake of the Pt/Nafion membrane was higher than that of the neat Nafion membrane.