• 제목/요약/키워드: membrane material

검색결과 1,081건 처리시간 0.032초

폐수중 티오시안산이온을 측정하기 위한 계면활성제를 이용한 고분자 막전극 (The Polymer Membrane Electrode by Surfactants for Measuring Continuously Thiocyanate Ion in Wastewater)

  • 최종석;안형환;강안수;우인성;황명환
    • 한국안전학회지
    • /
    • 제6권4호
    • /
    • pp.13-20
    • /
    • 1991
  • Ion-selective electrode responsive to the thiocynate ion prepared by using the quaternary ammonium salts as a active material and PVC as a membrane matrix. The effect of chemical structure and composition of active material, and the membrane thickness on the linear response. the detection limit, and Nernstian slope of the electrode studied. Under the above optimum conditions of membrane, the effect of pH and the selectivity coefficients to various interfering anions were compared and investigated. It was concluded that the functions of thiocynate ion-selective electrode(ISE) were closely related to the chemical structure of the quaternary ammonium salts. The linear response, and the detection limit of the electrode potential increased with the increase of the carbon chain length of the alkyl group in the quaternary ammonium salts in the ascending order of Aliquat 336T, TOAT, TDAT, and TDDAT. The optimum membrane thickness was 0.3mm. The electrode characteristics was better with the decrease of the concentration of active material, and the best concentration was 3 weight percent. The membrane potential was independent of the pH variation in the region from pH 2 to 12. The order of the selectivity coefficients is as follows:Cl $O_4$$^{[-10]}$$I^{[-10]}$ >N $O_3$$^{[-10]}$ >B $r^{[-10]}$$F^{[-10]}$ >C $l^{[-10]}$ >O $A_{c}$ $^{[-10]}$ 〓S $O_4$$^{2-}$.

  • PDF

천공형 티타늄 막의 조기 노출이 수직 골 형성에 미치는 영향 (The effect of early membrane exposure on exophytic bone formation using perforated titanium membrane)

  • 김은정;허익;권영혁;박준봉;정종혁
    • Journal of Periodontal and Implant Science
    • /
    • 제37권2호
    • /
    • pp.237-249
    • /
    • 2007
  • This study was performed to evaluate the effect of membrane exposure on new bone formation when guided bone regeneration with perforated titanium membrane on atrophic alveolar ridge. The present study attempted to establish a GBR model for four adult beagle dog premolar. Intra-marrow penetration defects were created on the alveolar ridge(twelve weeks after extraction) on the mandibular premolar teeth in the beagle dogs. Space providing perforated titanium membrane with various graft material were implanted to provide for GBR. The graft material were demineralized bovine bone(DBB), Irradiated cancellous bone(ICB) and demineralized human bone powder(DFDB). The gingival flap were advanced to cover the membranes and sutured. Seven sites experienced wound failure within 2-3weeks postsurgery resulting in membrane exposure. The animals were euthanized at 4 weeks postsurgery for histologic and histometric analysis. The results of this study were as follows: 1. There was little new bone formation at 4 weeks postsurgery. irrespectively of membrane exposure. 2. There was significant relationship between membrane exposure and bone graft resorption(P<0.05), but no relation between membrane exposure and infiltrated connective tissue. 3. There was much bone graft resorption on DFDB than ICB and DBB. 4. The less exposure was on the perforated titanium membrane, the more dense infiltrated connective tissue was filled under the membrane when grafted with ICB and DBB. but there was no relationship between the rate of membrane exposure and the percentage of infiltrated connective tissue area and no relationship between the percentage of the area in the infiltrated connective tissue and in the residual bone graft. Within the above results, bone formation may be inhibited when membrane was exposed and ICB and DBB were more effective than DFDB as a bone graft material when guided bone regeneration.

SOI와 트랜치 구조를 이용한 초저소비전력형 미세발열체의 제작과 그 특성 (The Fabrication of Micro-heaters with Low Consumption Power Using SOI and Trench Structures and Its Characteristics)

  • 정귀상;홍석우;이원재;송재성
    • 한국전기전자재료학회논문지
    • /
    • 제14권3호
    • /
    • pp.228-233
    • /
    • 2001
  • This paper presents the optimized design, fabrication and thermal characteristics of micro-heaters for thermal MEMS (micro elelctro mechanical system) applications usign SOI (Si-on-insulator) and trench structures. The micro-heater is based on a thermal measurement principle and contains for thermal isolation regions a 10㎛ thick Si membrane with oxide-filled trenches in the SOI membrane rim. The micro-heater was fabricated with Pt-RTD (resistance thermometer device) on the same substrate by suing MgO as medium layer. The thermal characteristics of the micro-heater wit the SOI membrane is 280$\^{C}$ at input power 0.9W; for the SOI membrane with 10 trenches, it is 580$\^{C}$ due to reduction of the external thermal loss. Therefore, the micro-heater with trenches in SOI membrane rim provides a powerful and versatile alternative technology for improving the performance of micro-thermal sensors and actuators.

  • PDF

막 구조물의 측지선을 이용한 재단도 생성에 관한 연구 (A Study on Cutting Pattern Generation of Membrane Structures by Using Geometric Line)

  • 안상길;손수덕;김승덕
    • 한국공간구조학회:학술대회논문집
    • /
    • 한국공간구조학회 2005년도 춘계학술발표회 및 정기총회 2권1호(통권2호)
    • /
    • pp.125-132
    • /
    • 2005
  • Membrane structures, a kind of lightweight soft structural system, are used for spatial structures. The material property of the membrane has strong axial stiffness, but little bending stiffness. The design procedure of membrane structures are needed to do shape finding, stress-deformation analysis and cutting pattern generation. In shape finding, membrane structures are unstable structures initially. These soft structures need to be introduced initial stresses because of its initial unstable state, and it happens large deformation phenomenon. And also there are highly varied in their size, curvature and material stiffness. So, the approximation inherent in cutting pattern generation methods is quite different. Therefore, in this study, to find the structural shape after large deformation caused by Initial stress, we need the shape analysis considering geometric nonlinear ten And the geodesic line on surface of initial equilibrium shape and the cutting pattern generation using the geodesic line is introduced.

  • PDF

SOI와 드랜치 구조를 이용한 초저소비전력형 미세발열체의 제작 (The fabrication of ultra-low consumption power type micro-heaters using SOI and trenche structures)

  • 정귀상;이종춘;김길중
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.569-572
    • /
    • 2000
  • This paper presents the optimized fabrication and thermal characteristics of micro-heaters for thermal MEMS applications using a SDB SOI substrate. The micro-heater is based on a thermal measurement principle and contains for thermal isolation regions a 10$\mu\textrm{m}$ thick silicon membrane with oxide-filled trenches in the SOI membrane rim. The micro-heater was fabricated with Pt-RTD(Resistance Thermometer Device)on the same substrate by using MgO as medium layer. The thermal characteristics of the micro-heater with the SOI membrane is 280$^{\circ}C$ at input Power 0.9 W; for the SOI membrane with 10 trenches, it is 580$^{\circ}C$ due to reduction of the external thermal loss. Therefore, the micro-heater with trenches in SOI membrane rim provides a powerful and versatile alternative technology for improving the performance of micro thermal sensors and actuators.

  • PDF

임플란트 식립시 동종뼈 막의 임상적 활용 (CLINICAL USES OF HOMOLOGOUS GELATINIZED BONE MATRIX(GBM) IN DENTAL IMPLANT SURGERY)

  • 이은영;김경원;엄인웅
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제28권3호
    • /
    • pp.229-236
    • /
    • 2006
  • The biologic principle of guided bone regeneration(GBR) has been studied extensively in hopes of regenerating alveolar bone. Various materials have been utilized as regenerative membranes and grafting materials in implant surgery. To improve the ability of membranes, several types of membrane have been developed. Various materials have been utilized as regenerative membranes; however, all materials have disadvantages, and the ideal membrane material is yet to be identified. In these cases, a homologous gelatinized bone matrix(GBM) were used as a regenerative material in conjunction with the placement of endosseous root implants. 22 patients participated in this study, and 42 implants were inserted. The result of 1st operative surgery was uneventful, inflammatory reaction and dehiscences were not observed except for only one case. After the final protheses, all implants were functioning successfully. The major advantages in the use of GBMs for guided bone regeneration are of very wide application such as membrane and graft material, and that a second procedure to remove the material is not necessary, and the GBMs are accepted by the surrounding tissues without complications. The purpose of this study was to observe the usefulness of GBMs in dental implant surgery.

막구조물의 준공평형형상해석 및 최적재단도 결정 (Determination of the Actual Equilibrium Shape Finding and Optimum Cutting Pattern for Membrane Structures)

  • 이장복;권택진
    • 한국공간구조학회논문집
    • /
    • 제1권1호
    • /
    • pp.157-166
    • /
    • 2001
  • In general, the cutting pattern of the membrane structures is determined by dividing the complicated curved 3-D surface into several 2-D plane strip by using flattening technique. In this procedure, however, some discrepancies ore occurred between actual stresses of equilibrated state and designed uniform stresses because the material properties are not considered. These deviations can cause the critical structural problems, wrinkling or overstress, and thus a optimization process should be considered. In this paper, a new analytical method for determining an optimum cutting pattern considering material properties is presented. Here, iterative procedure is introduced to decrease the errors caused in numerical process. The optimization method proposed can diminish the deviations occurred by material properties and numerical errors, simultaneously. As a results, it is shown that the final stress distributions for the HP shell model are sufficiently near to design stress distributions, and it can be concluded that this method can be used to obtain the optimized cutting pattern of membrane structures.

  • PDF

생체 청각기구를 모사한 폴리머 박막의 주파수 분리 특성 평가 (Characterization of Frequency Separation in Polymer Membranes Mimicking a Human Auditory System)

  • 송원준;배성재;김완두
    • 비파괴검사학회지
    • /
    • 제31권5호
    • /
    • pp.516-521
    • /
    • 2011
  • 청각기관인 달팽이관에 존재하는 기저막의 중요한 기능은 등자뼈로부터 전달되는 진동에너지를 주파수별로 분리하는 것이다. 본 연구에서는 인간 기저막의 형상을 모사하여 설계한 매크로 스케일의 폴리머 박막을 사용하여 주파수 분리 특성을 연구하였다. 각각의 폴리머 박막상의 위치에 따른 변위 분포는 LDV (laser Doppler vibrometer) 스캐닝 기법을 이용하여 측정하였고, 측정된 결과는 후처리 과정을 거쳐 주파수별로 분리하였다. 인가된 주파수에 따른 최대 변위 발생 위치를 추출하여 각 박막에 대한 주파수-최대 변위 발생 위치 관계를 도식화하였다. 아울러 박막 두께 및 물성치가 주파수-최대 변위 발생 위치 관계에 미치는 영향에 대해서도 논하였다.

Layer-by-Layer 코팅법을 적용한 복합막 제조와 투과성능 평가 (Preparation and Performance of Composite Membrane Prepared by Layer-by-Layer Coating Method)

  • 전이슬;임지원
    • 멤브레인
    • /
    • 제25권6호
    • /
    • pp.538-546
    • /
    • 2015
  • 폴리설폰막 위에 친수성 고분자를 Layer-by-Layer법으로 코팅하여 복합막을 제조하였다. FE-SEM 분석을 통하여 복합막 표면과 기공 내 코팅층을 확인하였다. 또한 100 ppm NaCl 용액에 대한 복합막의 투과성능 평가를 실시하였다. 복합막 제조를 위한 코팅 고분자는 PVSA, PEI, PAA, PSSA, PSSA_MA를 사용하였다. 폴리설폰막 표면에 8,000 ppm PAA (이온세기 0.35) 수용액을 3분 동안 코팅한 뒤 10,000 ppm PEI 수용액을 4분 동안 코팅하였다. 그 결과 PAA-PEI 복합막의 투과도는 101 LMH, 제거율은 66.7%로 가장 좋은 투과성능을 나타내었다. PAA-PEI 복합막의 투과성능은 도레이케미칼의 NE 4040-70 (투과도 = 30 LMH, 염 배제율 = 40~70%) 제품과 유사한 성능을 보여주는 우수한 투과 특성을 나타내었다.