• Title/Summary/Keyword: melting curve

Search Result 93, Processing Time 0.022 seconds

Effects of Nb Content and Thermal History on the Mechanical and Corrosion Characteristics of Stainless Steels

  • Choe, Han-Cheol;Kim, Kwan-Hyu
    • Corrosion Science and Technology
    • /
    • v.2 no.3
    • /
    • pp.117-126
    • /
    • 2003
  • Due to excellent corrosion resistance and mechanical properties, austenitic stainless steel is widely used as the material for chemical plants. nuclear power plants, and food processing facilities. But, the zone affected by heat in the range of 400 to $800^{\circ}C$ during welding loses corrosion resistance and tensile strength since Cr-carbide precipitation like $Cr_{23}C_6$ forms at the grain boundary and thereby takes place the intergranular corrosion. In this study, AISI 304 stainless steel with the added Nb of 0.3 to 0.7 wt% was solutionized at $1050^{\circ}C$ and sensitized at $650^{\circ}C$. Specimen was welded by MIG. The phase and the microstructure of the specimens were examined by an optical microscope, a scanning electron microscope, and a x-ray diffractometer. The corrosion characteristics of specimens were tested by electrolytic etching and by double loop electrochemical potentiokinetic reactivation method(EPR) in the mixed solution of 0.5M $H_2SO_4$ + 0.01M KSCN. The melting zone had dendritic structure constituted of austenitic phase and $\delta$-ferrite phase. Cr carbide at the matrix did not appear, as Nb content increased. At the grain boundaries of the heat affected zone, the precipitates decreased and the twins appeared. The hardness increased, as Nb content increased. The hardness was highest in the order of the heat affected zone>melted zone>matrix. According to EPR curve, as the Nb content decreased, the reactivation current density(Ir) and the activation current density(la) were highest in the order of the melted zone

Butadiene Polymerization Catalyzed by Tri(aryloxo)aluminum Adduct of Cobalt Acetate

  • Park, Ji Hae;Kim, Ahreum;Jun, Sung Hae;Kwag, Gwanghoon;Park, Ka Hyun;Lee, Junseong;Lee, Bun Yeoul
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.12
    • /
    • pp.4028-4034
    • /
    • 2012
  • Tris(2-phenylphenoxo)aluminum ($(2-PhC_6H_4O)_3Al$) exists as a dimeric form in toluene. When toluene-insoluble anhydrous cobalt acetate is treated with tris(2-phenylphenoxo)aluminum in toluene, the toluene-soluble adduct $(2-PhC_6H_4O)_3Al{\cdot}Co(OAc)_2$ is formed. The 2-phenylphenoxo ligand in the adduct can be replaced with another aryloxo ligand to give (aryloxo)$(2-PhC_6H_4O)_2Al{\cdot}Co(OAc)_2$ (aryloxo = 2-methylphenoxo, 2-isopropylphenoxo, 4-methylphenoxo, 4-isopropylphenoxo, or 4-tert-butylphenoxo). These complexes are active for butadiene polymerization without gel formation when activated with an equivalent amount of $(2-PhC_6H_4O)AlEt_2$ for 2 h. The highest activity, 175 kg/mol-Co (turnover number, 3200) was achieved with $(2-PhC_6H_4O)_3Al{\cdot}Co(OAc)_2$ at $65^{\circ}C$ for 2 h. The microstructure of the polymer chains is mostly trans-1,4-configuration (70-75%) with the remaining being 1,2-vinyl. The cis-1,4-configuration observed by IR is minimal (1-5%). By replacing the 2-phenylpheoxo with a 4-alkylphenoxo ligand, the amount of 1,4-configuration slightly increases, resulting in increase in the endothermic melting signal at $-30{\sim}50^{\circ}C$ in the DSC curve. The molecular weights of the polymers are high ($M_n$: 300000~800000) with a fairly narrow molecular weight distribution ($M_w/M_n$, 2.0-2.7).

A Study on the Effect of Field Shaping on Dose Distribution of Electron Beams (전자선의 선량분포에 있어서 Field Shaping의 효과에 관한 연구)

  • Kang, Wee-Saing;Cho, Moon-June
    • Radiation Oncology Journal
    • /
    • v.4 no.2
    • /
    • pp.165-172
    • /
    • 1986
  • In electron therapy, lead cutout or low-melting alloy block is used for shaping the field. Material for shaping electron field affects the output factor as wet 1 as the collimation system. The authors measured the output factors of electron beams for shaped fields from Clinac-18 using ionization chamber of Farmer type in polystyrene phantom. They analyzed the parameters that affect the output factors. The output factors of electron beams depend on the incident energy, collimation system and size of shaped field. For shaped field the variation of output factor for the field size (A/P) has appearence of a smooth curve for all energy and all applicator collimator combination. The output factors for open field deviate from the curves for shaped fields. An output factor for a given field can be calculated by equivalent field method such as A/P method, if a combination of applicator and collimator is fixed.

  • PDF

A study on the diffusion bonding of the $Al_2$O$_3$ ceramics to metal (A$_2$O$_3$세라믹과 Ni-Cr-Mo鋼과의 인서트 合金을 이용한 擴散接合에 關한 硏究)

  • 김영식;박훈종;김정일
    • Journal of Welding and Joining
    • /
    • v.10 no.3
    • /
    • pp.63-72
    • /
    • 1992
  • The joining methods of ceramics to metals which can be expected to obtain high temperature strength are mainly classified into the solid-state diffusion bonding method and the active brazing method. Between these two, the solid-state diffusion bonding method is given attentions as substituting method for active brazing method due to being capable of obtaining higher bonding strength at high temperature and accurate bonding. In this paper, the solid-state diffusion bonding of $Al_{2}$O$_{3}$ ceramics to Ni-Cr-Mo alloy steel (SNCM21) using insert metal was carried out. The insert metal employed in this study was experimentally home-made, Ag-Cu-Ti alloy. Influence of several bonding parameters of $Al_{2}$O$_{3}$SNCM21 joint was quantitatively evaluated by bonding strength test, and microstructural analyses at the interlayer were performed by SEM/EDX. From above experiments, the optimum bonding condition of the solid-state diffusion bonding of $Al_{2}$O$_{3}$/SNCM21 using Ag-Cu-Ti insert metal was determined. Futhermore, high temperature strength and thermal-shock properties of $Al_{2}$O$_{3}$/SNCM21 joint were also examined. The results obtained are as follows. 1. The maximum bonding strength was obtained at the temperature of 95% melting point of insert metal. 2. The high temperature strength of $Al_{2}$O$_{3}$/SNCM21 joint appeared to bemaximum value at test temperature 500.deg.C and the bonding strength with increasingtemperature showed parabolic curve. 3. The strength of thermal-shocked specimens was far deteriorated than those of as-bonded specimens. Especially, water-quenched specimen after heated up to 600.deg. C was directly fractured in quenching.

  • PDF

The Genes Expression Patterns Induced by High Temperature in Licorice (Glycyrrhiza uralensis F.) (온도상승에 따른 감초(Glycyrrhiza uralensis Fisch.)의 유전자 발현 양상)

  • Hyeju Seong;Woosuk Jung
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2020.12a
    • /
    • pp.56-56
    • /
    • 2020
  • 감초는 다년생 콩과(Leguminocae) 식물로 국내에서 시중가격이 높은 만주감초가 일부 재배되고 있다. 우리나라에서 감초 재배법이 불완전한 상황에서 한반도의 기후변화에 의한 온도 상승은 약용작물의 생산 및 품질에 많은 영향을 미칠 것으로 예상되므로 본 연구에서는 재배환경 중 온도 조건만 조절할 수 있는 온도구배터널(temperature gradient tunnel system)을 이용하여 4개의 T1(외기온도+0.5~1.3℃), T2(+1.3~2.2℃), T3(+2.2~3.2℃), T4(+3.2~4.0℃) 처리로 온도구배 하여 4년생 만주감초(Glycyrrhiza uralensis F.)를 재배하였다. 지하부가 오래된 모주와 신초1의 경우 저온(T1)과 중간구간(T2, T3)에서 초장과 총화수가 우세하였고, 번식이 가장 늦은 신초2의 경우 중간구간(T2, T3)에서의 생육 및 개화반응이 뚜렷했다. 각 온도처리구마다 3개의 감초 개체를 선발하여 모주의 정단으로부터 5개의 성엽을 채취하였다. Reverse transcription quantitative PCR (RT-qPCR)은 AccuPower® GreenStarTM RT-qPCR Master Mix (Bioneer, Korea)를 이용하여 진행되었다. Primer 디자인은 NCBI Primer-blast 프로그램을 사용해 제작하였고 ABI StepOne real time system (Applied Biosystem)의 melting curve analysis에서 one-peak test를 통해 gene specific primer임을 확인하였다. 각 온도처리구의 감초 잎에서 RNA를 추출하였고, RT-qPCR을 통해 감초의 유전자 발현양상을 비교, 분석하였다. Phytochrome interacting factor 4 (PIF4)는 식물 호르몬을 유발하는 전사조절을 조정함으로써 고온 신호전달에 핵심적인 역할을 수행한다. 활성화된 Phytochrome B(PhyB)는 PIF4의 활성을 억제한다고 알려졌다. Eukaryotic initiation factors(eIFs)는 mRNA 번역 개시인자로 유전자 발현과 특정 단백질 생산을 조절하는 역할을 한다. 본 결과는 온도조건에서 반응하는 생리적 변화를 전사체 수준에서 조사 분석하여 생리해석의 기초자료로 활용, 국내 감초 재배를 위한 환경조건 구명 및 적지 선정 기초자료로서 활용을 기대한다.

  • PDF

A study on the growth behavior of AlN single crystal according to the change of N2 in HVPE propcess (HVPE(Hydride Vapor Phase Epitaxy) 법을 적용한 N2 양의 변화에 따른 AlN 단결정의 성장 거동에 관한 연구)

  • Kyung-Pil Yin;Seung-Min Kang
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.34 no.2
    • /
    • pp.61-65
    • /
    • 2024
  • HVPE (Hydride vapor phase epitaxy) is a method of manufacturing thin films or single crystals using gaseous raw materials. This is a method that applies the principles of chemical vapor deposition to grow a single crystal of a material with low meltability or high melting point, and is one of the methods that can obtain a gallium nitride (GaN) single crystal. Recently, much research has been conducted to grow aluminum nitride (AlN) single crystals using this method, but good results have not yet been obtained. In this study, we attempted to grow AlN single crystals using the HVPE method. Nitrogen was used as a carrier gas in the growth process, and the growth results according to changes in the amount of nitrogen (N2) were examined. Changes in growth crystals as the amount of nitrogen increased were confirmed. The shape of the grown AlN single crystal was observed using an optical microscope, and the rocking curve was measured using double crystal X-ray diffractometry (DCXRD) to confirm the creation of the AlN crystal. The crystallinity of single crystals was also investigated.

Comparison of PANA RealTyper HPV Kit with AdvanSure HPV GenoBlot Assay for Human Papillomavirus Genotyping (인유두종바이러스 유전자형 검사법 PANA RealTyper HPV Kit와 AdvanSure HPV GenoBlot Assay의 비교)

  • Kim, Yi Hyeon;Chung, Hae-Sun;Lee, Miae
    • Annals of Clinical Microbiology
    • /
    • v.21 no.4
    • /
    • pp.86-91
    • /
    • 2018
  • Background: The PANA RealTyper HPV kit (PANAGENE, Korea; PANA RealTyper) was developed to genotype human papillomavirus (HPV) and was based on multiplex real-time PCR amplification and melting curve analysis. In this study, we compared PANA RealTyper to the AdvanSure HPV GenoBlot assay (LG Life Sciences, Korea; AdvanSure assay) and attempted to evaluate the performance of PANA RealTyper. Methods: A total of 60 cervical specimens were collected from women undergoing routine cervical cancer screening. The AdvanSure assay and PANA RealTyper kit identified the same 20 high-risk genotypes. However, the AdvanSure assay identified 15 low-risk genotypes, while the PANA RealTyper kit identified only 2 but detected 18 low-risk genotypes. Results: Among the total 60 specimens, 54 high-risk genotypes (40 specimens) and 20 low-risk genotypes (18 specimens) were detected. The agreement rates of the assays ranged from 94.4 to 100% for high-risk genotypes. Among 9 genotypes that were positive in the PANA RealTyper kit but negative in the AdvanSure assay, 7 were confirmed as true positive (HPV genotypes 16 (n=1), 39 (n=1), 52 (n=1), 58 (n=2), 68 (n=2)). Among 4 genotypes that were negative in the PANA RealTyper kit but positive in the AdvanSure assay, 3 were confirmed as HPV genotype 59. Among the 19 low-risk genotypes positive in the AdvanSure assay, there were 2 cases of HPV 6 and 1 case of HPV 11. In comparison, only 1 positive case of HPV 6 was determined by the PANA RealTyper kit. Conclusion: The PANA RealTyper kit was comparable with the AdvanSure assay. The PANA RealTyper kit would be useful and suitable for HPV genotyping in the clinical laboratory.

Report on the Stability of Freeze-dried Standard Solution (동결건조표준액의 안정성에 관한 보고)

  • Park, Jun Mo;Yoo, Hye Jung;Kim, Han Chul;Han, Geul Soon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.139-148
    • /
    • 2012
  • Purpose : Since standard solution is the one that knows its exact concentration, the curve of the dissolution has been determined according to the amount of the solution, compared to the amount of the unknown sample. Therefore, the antigen that makes up standard materials should be made in a pure form. The configuration of the standard substance solution in the kit we use is a freeze-dried material, or made and comes as a liquid. Lyophilized reference material is used after dissolving in usually D.W. (Distilled Water), and if the antigen to use is too sensitive, reagents should be freeze-dried. Furthermore, when freeze-dried reference has to be frozen again after being dissolved, it should be kept under $-20^{\circ}C$ until the expiration date according to the reports. Since it is not expressed in the experiment if it is safe or stable to reuse the solution which was dissolved a few times, thus, this time it is tested and evaluated that the changes of the standard solution by freezing and melting several times, and its results and the effectiveness of it were compared to the solution which was kept in a fridge. Materials and Methods : Among Vitro diagnostic kits on the market made by radioimmunoassay, parathyroid hormone (PTH), adrenocorticotropic hormone (ACTH), luteinizing hormone (LH) are made of freeze-dried standard solution and all composed of the same Lot.NO. These hormones melted in D.W. and were separated into three groups. In the first group, melting and freezing were repeated, and in the second group, The solution only for one time use was put into a test tube after melting and freeze it. The third group was kept in the refrigerator. This experiment has been conducted from January to February in 2012. January to 2012. PH test was employed because ph is prone to changing depending on the change of protein. Each group of the standard solution, cpm (counter per minute), and the patient relative concentration values were compared by date, and Through the correlation coefficient and Paired t-test, the significant level of each group was analyzed. Results : ACTH, PTH, LH pH values were too subtle denaturation rather than numerical changes in the protein. In addition, when the standard solution of ACTH, PTH, LH was refrigerated, after 3 days and 7 days, there was a significant difference observed between the solution being kept in a refrigerator and a freezer within a significance level. Conclusion : Standard solution should be kept in a freezer, and being kept in a fridge, it is recommended to use the solution as soon as possible.

  • PDF

Development of HRM Markers Based on SNPs Identified from Next Generation Resequencing of Susceptible and Resistant Parents to Gummy Stem Blight in Watermelon (수박에서 덩굴마름병 감수성 및 저항성 양친에 대한 차세대 염기서열 재분석으로 탐색된 SNP 기반 HRM 분자표지 개발)

  • Lee, Eun Su;Kim, Jinhee;Hong, Jong Pil;Kim, Do-Sun;Kim, Minkyong;Huh, Yun-Chan;Back, Chang-Gi;Lee, Jundae;Lee, Hye-Eun
    • Korean Journal of Breeding Science
    • /
    • v.50 no.4
    • /
    • pp.424-433
    • /
    • 2018
  • Watermelon (Citrullus lanatus) is an economically important vegetable crop all over the world, which has functional compounds such as lycopene and citrulline. Gummy stem blight caused by Didymella bryoniae is one of the most devastative diseases in watermelon. Single nucleotide polymorphisms (SNPs), which are genetic variations occurring between individuals with respect to a single base, were often used to construct genetic linkage maps and develop molecular markers linked to a variety of horticultural traits and resistance to several diseases. In this study, we developed high-resolution melting (HRM) markers based on SNPs generated from NGS resequencing of two parents in watermelon. Plant materials were C. lanatus '920533' (female and susceptible parent), C. amarus 'PI 189225' (male and resistant parent), and their $F_1$ and $F_2$ progenies. A total of 13.6 Gbp ('920533') and 13.1 Gbp ('PI 189225') of genomic sequences were obtained using NGS analysis. A total of 6.09 million SNPs between '920533' and 'PI 189225' were detected, and 354,860 SNPs were identified as potential HRM primer sets. From these, a total of 330 primer sets for HRM analysis were designed. As a result, a total of 61 HRM markers that have polymorphic melting curves were developed. These HRM markers can be used for the construction of SNP-based linkage maps and for the analysis of quantitative trait loci (QTLs) related to gummy stem blight resistance.

CYP1A1 (Ile462Val), CYP1B1 (Ala119Ser and Val432Leu), GSTM1 (null), and GSTT1 (null) Polymorphisms and Bladder Cancer Risk in a Turkish Population

  • Berber, Ufuk;Yilmaz, Ismail;Yilmaz, Omer;Haholu, Aptullah;Kucukodaci, Zafer;Ates, Ferhat;Demirel, Dilaver
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.6
    • /
    • pp.3925-3929
    • /
    • 2013
  • We aimed to investigate bladder cancer risk with reference to polymorphic variants of cytochrome p450 (CYP) 1A1, CYP1B1, glutathione S-transferase (GST) M1, and GSTT1 genes in a case control study. Polymorphisms were examined in 114 bladder cancer patients and 114 age and sex-matched cancer-free subjects. Genotypes were determined using allele specific PCR for CYP1A1 and CYP1B1 genes, and by multiplex PCR and melting curve analysis for GSTM1 and GSTT1 genes. Our results revealed a statistically significant increased bladder cancer risk for GSTT1 null genotype carriers with an odds ratio of 3.06 (95% confidence interval=1.39-6.74, p=0.006). Differences of CYP1A1, CYP1B1 and GSTM1 genotype frequencies were not statistically significant between patients and controls. However, the specific combination of GSTM1 null, GSTT1 null, and CYP1B1 codon 119 risk allele carriers and specific combination of GSTM1 present, GSTT1 null, and CYP1B1 432 risk allele carriers exhibited increased cancer risk in the combined analysis. We did not observe any association between different genotype groups and prognostic tumor characteristics of bladder cancer. Our results indicate that inherited absence of GSTT1 gene may be associated with bladder cancer susceptibility, and specific combinations of GSTM1, GSTT1 and CYP1B1 gene polymorphisms may modify bladder cancer risk in the Turkish population, without any association being observed for CYP1A1 gene polymorphism and bladder cancer risk.