• 제목/요약/키워드: mega frame structure

검색결과 14건 처리시간 0.026초

메가골조구조물 전용 해석프로그램의 개발 (Development of Analysis Program for Mega Frame System)

  • 김현수;유일향;이동근
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2006년도 정기 학술대회 논문집
    • /
    • pp.873-880
    • /
    • 2006
  • Since the mega frame structure has significant numbers of elements and nodes, it takes tremendous times and computer memories to analyze and design the structures. Therefore, the exclusive structural analysis program for mega frame system is developed to reduce the efforts and time required for the analysis and design of mega frame structure. To this end, an efficient modelling technique using the characteristics of mega frame structures and an efficient analytical model, which uses a few DOFs selected by the user using the matrix condensation method. are developed in tins study. Static and dynamic analyses are conducted using an example structure.

  • PDF

초대형 골조시스템 전용 전후처리 및 해석프로그램의 개발 (Development of Structural Analysis and Pre-post Program for Mega Frame System)

  • 김현수;이동근
    • 한국전산구조공학회논문집
    • /
    • 제19권3호
    • /
    • pp.283-293
    • /
    • 2006
  • 근래에 들어서 사회적 및 경제적인 요구에 의하여 건축구조물이 점차 고층화 및 대형화됨에 따라서 다양한 형식의 구조시스템이 연구 및 개발되고 있다. 비교적 최근에 개발된 초대형 골조시스템은 초대형부재의 조합으로 횡방향 강성을 충분히 발휘함으로써 초고층건물에 적합한 구조시스템으로 인식되고 있다. 그러나 이러한 초대형 골조시스템을 적용한 건물의 거동을 예측하기 위해서는 매우 많은 수의 절점과 요소로 이루어진 유한요소 모델을 해석해야 하므로 상당한 양의 해석시간과 엔지니어의 노력이 필요하게 된다. 따라서 본 연구에서는 초대형 골조시스템 전용 해석프로그램을 개발하여 초대형 골조구조물의 해석과 설계에 소요되는 시간과 노력을 줄이고자 한다. 이를 위하여 초대형 골조구조물의 특징을 활용한 효율적인 모형화기법과 행렬응축기법을 사용하여 해석에 사용되는 자유도수를 최소화도록 만든 해석모델이 개발되었다. 예제구조물의 해석을 수행하여 본 연구에서 개발된 프로그램을 사용한 결과와 일반적인 해석방법에 의한 결과와 비교함으로써 개발된 프로그램의 효율성과 정확성을 검증하였다.

Challenge in the Structural Design of Suzhou IFS

  • Zhou, Jianlong;Huang, Yongqiang
    • 국제초고층학회논문집
    • /
    • 제10권3호
    • /
    • pp.165-171
    • /
    • 2021
  • Core-outrigger-mega frame system is used in Suzhou IFS with 95-story, 450 m-tall, which is beyond Chinese code limit. Besides simple introduction on design principle, structure system and analysis, key techniques including performance based design criteria, frame shear ratio, capacity check of mega column, human comfort criteria under wind induced vibration and TSD design were presented in details for reference of similar super tall building design.

다이어그리드 메가프레임 초고층 건물을 위한 효율적인 해석모델의 개발 (Development of Efficient Analytical Model for a Diagrid Mega-Frame Super Tall Building)

  • 김현수;강주원
    • 한국공간구조학회논문집
    • /
    • 제11권3호
    • /
    • pp.95-103
    • /
    • 2011
  • 비정형 초고층건물을 위한 구조시스템 중에서 다이어그리드 구조시스템은 구조적인 효율성 및 조형성 때문에 널리 사용되고 있다. 근래에는 초고층건물을 위한 구조시스템으로 메가부재의 조합을 통하여 횡방향 강성을 효과적으로 발휘할 수 있는 메가프레임 시스템이 널리 사용되고 있다. 두 가지 구조시스템의 장점을 혼합한 다이어그리드 메가프레임 구조시스템은 미래형 초고층건물에 적용될 유망한 구조시스템으로 평가받고 있다. 그러나 이러한 다이어그리드 메가프레임 구조시스템을 적용한 건물의 거동을 예측하기 위해서는 매우 많은 수의 절점과 요소로 이루어진 유한요소 모델을 해석해야 하므로 상당한 양의 해석시간과 엔지니어의 노력이 필요하게 된다. 따라서 본 연구에서는 다이어그리드 메가프레임시스템을 적용한 초고층건물의 거동을 효율적으로 해석할 수 있는 기법을 제안하여 다이어그리드 메가프레임 초고층건물의 해석과 설계에 소요되는 시간과 노력을 줄이고자 한다. 이를 위하여 다이어그리드 메가프레임의 특정을 활용한 효율적인 모형화기법과 행렬응축기법을 사용하여 해석에 사용되는 자유도수를 최소화한 해석기법을 제안하였다. 예제구조물의 해석을 수행하여 본 연구에서 제안된 해석방법과 일반적인 해석방법에 의한 결과와 비교함으로써 제안된 방법의 효율성과 정확성을 검증하였다.

준능동 TMD를 이용한 메가골조구조물의 진동제어 (Vibration Control of Mega Frame Structures using a Semi-active Tuned Mass Damper)

  • 김현수;이동근
    • 한국지진공학회논문집
    • /
    • 제11권2호
    • /
    • pp.57-68
    • /
    • 2007
  • 메가골조시스템은 사용되는 구조재료를 절약하면서도 구조물의 강성을 효과적으로 높일 수 있는 장점 때문에 고층건물의 설계에 많이 사용되고 있다. 이러한 메가골조시스템이 주로 적용되고 있는 초고층건물의 구조설계에서는 횡하중에 대한 거주자의 불안감을 최소화시키는 것이 주요한 관심사중의 하나이다. 따라서 본 연구에서는 메가골조구조물의 사용성을 향상시키기 위한 방법으로 일반적인 수동 TMD의 제어성능을 개선한 준능동 TMD(STMD)를 사용하였다. 이를 위하여 TMD에서 일반적으로 사용되고 있는 수동감쇠기 대신 준능동 MR 감쇠기를 사용하여 STMD를 구성하였다. 메가골조구조물의 일반적인 유한요소해석모델은 매우 많은 수의 자유도로 구성되어 있기 때문에 원형모델을 사용하여 STMD의 제어성능을 검토하는 것은 현실적으로 불가능하다. 따라서 메가골조구조물의 동적 거동을 정확하게 표현할 수 있는 최소한의 자유도를 가진 응축모델을 행렬응축기법을 이용하여 제안하였다. 또한 일반적인 행렬응축기법의 효율성을 향상시키기 위하여 메가골조구조물의 특성을 활용한 다단계 행렬응축기법을 제안하였다. 본 연구에서 제안된 응축모델을 사용한 제어의 효율성과 정확성 및 메가골조구조물에 대한 STMD의 제어성능을 예제해석을 통하여 검증하였다.

The Structural Design of "China Zun" Tower, Beijing

  • Liu, Peng;Cheng, Yu;Zhu, Yan-Song
    • 국제초고층학회논문집
    • /
    • 제5권3호
    • /
    • pp.213-220
    • /
    • 2016
  • The "China Zun" tower in Beijing will rise to 528 meters in height and will be the tallest building in Beijing once built. Inspired by an ancient Chinese vessel, the "Zun", the plan dimensions reduce gradually from the bottom of the tower to the waist and then expand again as it rises to form an aesthetically beautiful and unique geometry. To satisfy the structural requirement for seismic and wind resistance, the structure is a dual system composed of a perimeter mega structure made of composite mega columns, mega braces, and belt trusses, and a reinforced-concrete core with steel plate-embedded walls. Advanced parametric design technology is applied to find the most efficient outer-perimeter structure system. The seismic design basically follows a mixed empirical and performance-based methodology that was verified by a shaking table test and other specimen lab tests. The tower is now half-way through its construction.

The Structural Design of Tianjin Goldin Finance 117 Tower

  • Liu, Peng;Ho, Goman;Lee, Alexis;Yin, Chao;Lee, Kevin;Liu, Guang-lei;Huang, Xiao-yun
    • 국제초고층학회논문집
    • /
    • 제1권4호
    • /
    • pp.271-281
    • /
    • 2012
  • Tianjin Goldin Finance 117 tower has an architectural height of 597 m, total of 117 stories, and the coronation of having the highest structural roof of all the buildings under construction in China. Structural height-width ratio is approximately 9.5, exceeding the existing regulation code significantly. In order to satisfy earthquake and wind-resisting requirements, a structure consisting of a perimeter frame composed of mega composite columns, mega braces and transfer trusses and reinforced concrete core containing composite steel plate wall is adopted. Complemented by some of the new requirements from the latest Chinese building seismic design codes, design of the super high-rise building in high-intensity seismic area exhibits a number of new features and solutions to professional requirements in response spectrum selection, overall stiffness control, material and component type selection, seismic performance based design, mega-column design, anti-collapse and stability analysis as well as elastic-plastic time-history analysis. Furthermore, under the prerequisite of economic viability and a series of technical requirements prescribed by the expert review panel for high-rise buildings exceeding code limits, the design manages to overcome various structural challenges and realizes the intentions of the architect and the client.

Structural Design of Cheongna City Tower

  • Chung, Kwangryang;Kim, Jung-Hyun;Song, Younghoon;Kim, Sihyeong;Kang, Jihun
    • 국제초고층학회논문집
    • /
    • 제10권3호
    • /
    • pp.193-201
    • /
    • 2021
  • Cheongna City Tower is a 448-meter-high rise observatory tower with 8.7:1 aspect ratio located at central lake park in Incheon Cheongna international city. The tower is a crystal shaped image and it turns invisible when the façade is activated. The tower was planned to be hexagonal 30-story building with two basements which are composed of mega frame structure using mega column and mega brace. In order to minimize the wind effect, the blow-through area was installed so that the wind can pass through. This observatory tower is an unprecedented project since the whole building is covered by façade for invisibility effect.

Structural System Selection and Highlights of Changsha IFC T1 Tower

  • Jianlong, Zhou;Daoyuan, Lu;Liang, Huang;Jun, Ji;Jun, Zhu;Jingyu, Wang
    • 국제초고층학회논문집
    • /
    • 제3권2호
    • /
    • pp.99-106
    • /
    • 2014
  • This paper presents the determination of the structural system of the Changsha IFC T1 tower with 452 m in architectural height and 440.45 m in structural height. Sensitivity analyses are carried out by varying the location of belt trusses and outriggers. The enhancement of seismic capacity of the outer frame by reasonably adjusting the column size is confirmed based on parametric studies. The results from construction simulation including the non-load effect of structures demonstrate that the deformation of vertical members has little effect on the load-bearing capacity of belt trusses and outriggers. The elastoplastic time-history analysis shows that the overall structure under rare earthquake load remains in an elastic state. The influence of the frame shear ratio and frame overturning moment ratio on the proposed model and equivalent mega column model is investigated. It is found that the frame overturning moment ratio is more applicable for judging the resistance of the outer frame against lateral loads. Comparison is made on the variation of these two effects between a classical frame-core tube-outrigger structure and a structure with diagonal braces between super columns under rare earthquakes. The results indicate that plasticity development of the top core cube of the braced structure may be significantly improved.

Generic optimization, energy analysis, and seismic response study for MSCSS with rubber bearings

  • Fan, Buqiao;Zhang, Xun'an;Abdulhadi, Mustapha;Wang, Zhihao
    • Earthquakes and Structures
    • /
    • 제19권5호
    • /
    • pp.347-359
    • /
    • 2020
  • The Mega-Sub Controlled Structure System (MSCSS), an innovative vibration passive control system for building structures, is improved by adding lead rubber bearings (LRBs) on top of the substructure. For the new system, a genetic algorithm is used to optimize the dynamic parameters and distributions of dampers and LRBs. The program uses various seismic performance indicators as optimization objectives, and corresponding results are compared. It is found that the optimization procedure for maximizing the energy dissipation ratio yields the best solutions, and optimized models have consistent seismic performances under different earthquakes. Seismic performances of optimized MSCSS models with and without LRBs, as well as the traditional Mega-Sub Structure model, are evaluated and compared under El Centro wave, Taft wave and 20 other artificial waves. In both elastic and plastic analysis, the model with LRBs shows significantly smaller story drift and horizontal acceleration than those of the other two models, and fewer plastic hinges are developed during severe earthquakes. Energy analysis also shows that LRBs installed in proper locations increase the deformation and energy dissipation of dampers, thereby significantly reduce the kinetic, potential, and hysteretic energy in the structure. However, LRBs do not have to be mounted on all the additional columns. It is also demonstrated that LRBs at unfavorable locations can decrease the energy dissipation for dampers. After LRBs are installed, the optimal damping coefficient and the optimal damping exponent of dampers are reduced to produce the best damping effect.