• Title/Summary/Keyword: medical material

Search Result 2,233, Processing Time 0.031 seconds

A TISSUE RESPONSE TO THE TITANIUM ALLOY (Ti-13Zr-6Nb) IN VIVO

  • Kim Chang-Su;Lee Seok-Hyung;Shin Sang-Wan;Suh Kyu-Won;Ryu Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.6
    • /
    • pp.619-627
    • /
    • 2004
  • Statement of problem. Mechanisms of tissue-implant interaction and the effect of the implant surface on the behavior of cells has not yet been clarified. Purpose. This study was performed to investigate the tissue reaction to the titanium alloy submerged into rat peritoneum in vivo. Materials and methods. Titanium alloys (titanium-13Zirconium-6Niobium) were inserted inside the peritoneal cavity of Sprague Dawley rats. After 3 months, the tissue formed around the inserted titanium alloys were examined with a light-microscope. Tissue reaction around the material was analyzed by confocal microscopy to evaluate their biocompatibility in a living body. Results. In in vivo study, foreign body type multinucleated giant cells were found in the fibrous tissue formed as a reaction to the foreign material (4 in 20 cases), but the inflammatory reaction was very weak. After experiment, the contaminants of biomaterials was removed from living tissue. In confocal microscopy, we observed that the staining of vinculin and actin showed mixed appearance. In a few cases, we found that the staining of vinculin and beta-catenin showed the prominent appearance. Conclusion. We found that titanium-13Zirconium-6Niobium alloy was an excellent biomaterial.

Determination of Buprenorphine in Raw Material and Pharmaceutical Products Using Ion-pair Formation

  • Amanlou, Massoud;Khosravian, Peghah;Souri, Effat;Dadrass, Orkideh Ghorban;Dinarvand, Rasoul;Alimorad, Mohammad Massoud;Akbari, Hamid
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.2
    • /
    • pp.183-187
    • /
    • 2007
  • A simple and sensitive extractive spectrophotometric method has been described for the determination of buprenorphine either in raw material or in pharmaceutical formulations. The developed method is based on the formation of a colored ion-pair complex (1 : 1 drug/dye) of buprenorphine and bromocresol green (BCG) in buffer pH 3 and extracting in chloroform. The extracted complex shows absorbance maxima at 415 nm. Beer's law is obeyed in the concentration range of 1.32-100.81 μ g mL-1. The proposed method has been applied successfully for the determination of drug in commercial sublingual tablets and injectable dosage form. No significant interference was observed from the excipients commonly used as pharmaceutical aids with the assay procedure.

System Development and Fundamental Study of CCD Camera Based Electronic Portal Imaging Device (CCD Camera 기반 실시간 방사선치료조사면 검증 시스템 개발 및 화질개선을 위한 기초연구)

  • Jang, Gi-Won;Park, Ji-Koon;Lee, Dong-Gil;Kim, Jin-Yeong;Nam, Sang-Hee;Ha, Sung-Whan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.380-383
    • /
    • 2003
  • The purpose of this study is to develope prototype EPID system and improve image quality of radiation therapy field imaging system using CCD camera. For this research we used Linac(Clinac 4/100), Copper metal plate, $Gd_2O_2S_2$ phosphor and CCD camera(Photronic). In this study we find best thickness of buil-up metal plate and acquired projection image of humanoid head phantom. Also we enhanced raw image data using superposition and histogram stretching method. Through the thickness optimized of metal plate and image processing, we confirmed of an improved image quality of an EPID system using CCD camera. As result, highest quality image was acquired at 1mm thickness of Copper metal plate and improved image quality by image processing methods.

  • PDF

Knowledge on Fish in the Imwon-Gyeongje-Ji from a Korean Medical Perspective - A Comparative Study with the Dongui-bogam - (『림원경제지(林園經濟志)』 어류지식의 한의학적 고찰 - 『동의보감(東醫寶鑑)』과의 비교를 중심으로 -)

  • JEON, Jongwook
    • Journal of Korean Medical classics
    • /
    • v.35 no.3
    • /
    • pp.71-90
    • /
    • 2022
  • Objectives : This paper summarizes contents on fish in the Injeji and Jeoneo-Ji parts in the Imwon-Gyeongje-Ji and compares them with those in the Dong-uibogam from a Korean Medical perspective. Methods : Most of the knowledge of fish in the Imwon-Gyeongje-Ji is based on preceding material medica studies such as the Dongui-bogam in Joseon, the Bencao-gangmu in China, and the Hwahan Samjaedohoe in Japan. The influential relationships and the process of change among these knowledge information were examined within the context of each literature's development or through identifiable changes in knowledge on each particular kind of fish. Results & Conclusions : In the Imwon-Gyeongje-Ji, the consisting 16 parts are organically connected, sometimes functioning as cross-references. In particular, the medical contents on the efficacy of fish for treating disease is closely linked to contents on fish ecology and environment as written in the Jeoneo-Ji, which deals with the field of living things. On the more detailed knowledge on about 30 kinds of fish, one could grasp the formation process and changes of East Asian traditional knowledge on fishkind among historical study of influential Chinese texts, new stimulation and methodology through Japanese literature on natural history, and dynamic processes of inheriting and selectively accepting traditional knowledge of Joseon.

Publish or Perish (출판하여 살아남기)

  • Choe, Won-Sick
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.5
    • /
    • pp.263-268
    • /
    • 2003
  • Purpose: This editorial deals with the basic structures of medical papers in general and emphasizes the ethics of authors and reviewers. A majority of the content originated from educational material issued at the 2002 Annual Meeting for the Korean Committee of Medical Journal Editors. Current issues from the publication of the Korean Journal of Nuclear Medicine were also included.

Clinical Implementation of 3D Printing in the Construction of Patient Specific Bolus for Photon Beam Radiotherapy for Mycosis Fungoides

  • Kim, Sung-woo;Kwak, Jungwon;Cho, Byungchul;Song, Si Yeol;Lee, Sang-wook;Jeong, Chiyoung
    • Progress in Medical Physics
    • /
    • v.28 no.1
    • /
    • pp.33-38
    • /
    • 2017
  • Creating individualized build-up material for superficial photon beam radiation therapy at irregular surface is complex with rice or commonly used flat shape bolus. In this study, we implemented a workflow using 3D printed patient specific bolus and describe our clinical experience. To provide better fitted build-up to irregular surface, the 3D printing technique was used. The PolyLactic Acid (PLA) which processed with nontoxic plant component was used for 3D printer filament material for clinical usage. The 3D printed bolus was designed using virtual bolus structure delineated on patient CT images. Dose distributions were generated from treatment plan for bolus assigned uniform relative electron density and bolus using relative electron density from CT image and compared to evaluate the inhomogeneity effect of bolus material. Pretreatment QA is performed to verify the relative electron density applied to bolus structure by gamma analysis. As an in-vivo dosimetry, Optically Stimulated Luminescent Dosimeters (OSLD) are used to measure the skin dose. The plan comparison result shows that discrepancies between the virtual bolus plan and printed bolus plan are negligible. (0.3% maximum dose difference and 0.2% mean dose difference). The dose distribution is evaluated with gamma method (2%, 2 mm) at the center of GTV and the passing rate was 99.6%. The OSLD measurement shows 0.3% to 2.1% higher than expected dose at patient treatment lesion. In this study, we treated Mycosis fungoides patient with patient specific bolus using 3D printing technique. The accuracy of treatment plan was verified by pretreatment QA and in-vivo dosimetry. The QA results and 4 month follow up result shows the radiation treatment using 3D printing bolus is feasible to treat irregular patient skin.

Surface microhardness of three thicknesses of mineral trioxide aggregate in different setting conditions

  • Shokouhinejad, Noushin;Jafargholizadeh, Leila;Khoshkhounejad, Mehrfam;Nekoofar, Mohammad Hossein;Raoof, Maryam
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.4
    • /
    • pp.253-257
    • /
    • 2014
  • Objectives: This study aimed to compare the surface microhardness of mineral trioxide aggregate (MTA) samples having different thicknesses and exposed to human blood from one side and with or without a moist cotton pellet on the other side. Materials and Methods: Ninety cylindrical molds with three heights of 2, 4, and 6 mm were fabricated. In group 1 (dry condition), molds with heights of 2, 4, and 6 mm (10 molds of each) were filled with ProRoot MTA (Dentsply Tulsa Dental), and the upper surface of the material was not exposed to any additional moisture. In groups 2 and 3, a distilled water- or phosphate-buffered saline (PBS)-moistened cotton pellet was placed on the upper side of MTA, respectively. The lower side of the molds in all the groups was in contact with human blood-wetted foams. After 4 day, the Vickers microhardness of the upper surface of MTA was measured. Results: In the dry condition, the 4 and 6 mm-thick MTA samples showed significantly lower microhardness than the 2 mm-thick samples (p = 0.003 and p = 0.001, respectively). However, when a distilled water- or PBS-moistened cotton pellet was placed over the MTA, no significant difference was found between the surface microhardness of samples having the abovementioned three thicknesses of the material (p = 0.210 and p = 0.112, respectively). Conclusions: It could be concluded that a moist cotton pellet must be placed over the 4 to 6 mm-thick MTA for better hydration of the material. However, this might not be necessary when 2 mm-thick MTA is used.

Transport property of a Se:As films for digital x ray imaging

  • Kim, Jae-Hyung;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.04a
    • /
    • pp.85-88
    • /
    • 2006
  • The transport properties of amorphous selenium typical of the material used in direct conversion x-ray imaging devices are reported. The effects of As addition on the carrier mobility and recombination lifetime in amorphous selenium (a-Se) films have been studied using the moving photocarrier grating (MPG) technique. We have found an increase in hole drift mobility and recombination lifetime, especially when 0.3% As is added into a-Se film, whereas electron mobility decreases with As addition due to the defect density. The transport properties for As doped a-Se films obtained by using MPG technique have been compared with the drift mobilities of holes and electrons obtained by time of flight (TOF) measurement.

  • PDF

Development of a New Liquid Embolic for Arteriovenous Malformation (동정맥기형 치료를 위한 액상폐색물질 개발)

  • Park, S.;Huh, S.J.;Suh, D.C.;Song, H.Y.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.439-442
    • /
    • 1997
  • For the treatment of arteriovenous malformations (AVM), we developed a new liquid embolic material and named it Embol. The material was pre-tested in an in vitro AVM model and tested in rete mirabile of pigs that is similar in structure with the AVM in human. We report on the construction of the in vitro AVM model, the pre-test results of Embol in the AVM model, and the animal test result in pig rete mirabile.

  • PDF

Complications after craniofacial reconstruction with calcium phosphate cements: a case report and review of the literature

  • Pourdanesh, Fereydoun;Latifi, Noorahmad;Latifi, Fatemeh
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.44 no.5
    • /
    • pp.207-211
    • /
    • 2018
  • Among different graft materials for craniofacial reconstruction, calcium phosphate cements have the advantages of alloplastic grafts and wide use. The authors report a case of foreign body reaction following frontal reconstruction with JectOS (an injectable calcium orthophosphate cement; Kasios) and reviewed the literature on complications of this material after craniofacial reconstruction from 2002 to 2017. Complications were categorized into two groups: immunologic reactions (consisting of seroma collection, chronic sinus mucosa swelling, and foreign body reaction) and non-immune events (infection, fragmentation, and ejection). It is wise to use calcium phosphate-based material only in selected cases with small defects, and long-term follow-up is needed to observe their consequences.