Computer Assisted EPID Analysis of Breast Intrafractional and Interfractional Positioning Error (유방암 방사선치료에 있어 치료도중 및 분할치료 간 위치오차에 대한 전자포탈영상의 컴퓨터를 이용한 자동 분석)

  • Sohn Jason W.;Mansur David B.;Monroe James I.;Drzymala Robert E.;Jin Ho-Sang;Suh Tae-Suk;Dempsey James F.;Klein Eric E.
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.24-31
    • /
    • 2006
  • Automated analysis software was developed to measure the magnitude of the intrafractional and interfractional errors during breast radiation treatments. Error analysis results are important for determining suitable planning target volumes (PTV) prior to Implementing breast-conserving 3-D conformal radiation treatment (CRT). The electrical portal imaging device (EPID) used for this study was a Portal Vision LC250 liquid-filled ionization detector (fast frame-averaging mode, 1.4 frames per second, 256X256 pixels). Twelve patients were imaged for a minimum of 7 treatment days. During each treatment day, an average of 8 to 9 images per field were acquired (dose rate of 400 MU/minute). We developed automated image analysis software to quantitatively analyze 2,931 images (encompassing 720 measurements). Standard deviations ($\sigma$) of intrafractional (breathing motion) and intefractional (setup uncertainty) errors were calculated. The PTV margin to include the clinical target volume (CTV) with 95% confidence level was calculated as $2\;(1.96\;{\sigma})$. To compensate for intra-fractional error (mainly due to breathing motion) the required PTV margin ranged from 2 mm to 4 mm. However, PTV margins compensating for intefractional error ranged from 7 mm to 31 mm. The total average error observed for 12 patients was 17 mm. The intefractional setup error ranged from 2 to 15 times larger than intrafractional errors associated with breathing motion. Prior to 3-D conformal radiation treatment or IMRT breast treatment, the magnitude of setup errors must be measured and properly incorporated into the PTV. To reduce large PTVs for breast IMRT or 3-D CRT, an image-guided system would be extremely valuable, if not required. EPID systems should incorporate automated analysis software as described in this report to process and take advantage of the large numbers of EPID images available for error analysis which will help Individual clinics arrive at an appropriate PTV for their practice. Such systems can also provide valuable patient monitoring information with minimal effort.

  • PDF

An Analysis of the Determinants of Employment and Wage of New College Graduates (신규대졸자의 취업 및 임금수준 결정요인 분석)

  • Chai, Goo-Mook
    • Korean Journal of Social Welfare
    • /
    • v.59 no.4
    • /
    • pp.35-61
    • /
    • 2007
  • This study examines the determinants of employment and wage of new college graduates by using Youth Panel Data(2003-2005) of the Work Information Center, and seeks assignments for mitigating unemployment and wage disparities of new college graduates. Results are summarized as follows. First, an analysis of the determinants of employment shows that the Kyunggi Inchon district in school locations, higher school records, and qualification certificates positively affect the employment rate, while the private college group in the non-capital area negatively affects the employment rate. Second, an analysis of determinants of standard employment demonstrates that the Kyunggi Inchon district in school locations, higher school records, qualification certificates, and the major group of medical science, pharmacy, nursing science and health science, and the major group of education positively affect the employment rate, while the private college group in the non-capital area, the junior college groups in the capital and non-capital areas negatively affect the employment rate. Third, an analysis of determinants of nonstandard employment shows that the junior college graduation in scholarly attainments, the junior college groups in the capital and non-capital areas positively affect the employment rate, while the private college group in the non-capital area negatively affects the employment rate. Fourth, an analysis of the determinants of wages demonstrates that male in sex, the older in ages, the major group of medical science, pharmacy, nursing science and health science, and the major group of education positively affect the wages, while nonstandard employment, Kyunggi Inchon and Cholla districts in school locations negatively affect the wages. These results suggest several implications. First, college education should be reformed to cultivate professional manpower who are required by industries. Second, alternative measures to mitigate sex discrimination in labor markets should be prepared. Third, the process of attaining qualification certificates should be reformed in order that it is actually connected to the abilities of work performances and the improvement of productivity. Fourth, a locally balanced development must be realized through the decentralization of industries. Fifth a systematic and comprehensive program need to be prepared to promote the employment of new college graduates.

  • PDF

Bladder Volume Variations in Patients Receiving Conformal Radiotherapy to Prostate (전립선암 환자의 방사선 치료 시 방광 체적 변화)

  • Lee, Re-Na;Lee, Ji-Hye;Lee, Kyung-Ja;Ji, Young-Hoon
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.2
    • /
    • pp.61-65
    • /
    • 2008
  • Objective: To reduce urinary side effects in prostate cancer patients receiving radiation, patients were asked to drink certain amount of water to maintain bladder volume constant and the bladder volumes were measured weekly using ultrasound scanner. Materials and Methods: Twenty-six patients with prostate cancer who received radiation between December 2002 and August 2007 were enrolled in this study. Thirteen patients were enrolled in experimental group. These patients were asked to drink 450 cc of water, one hour prior to simulation, CT scan, and treatment. The other thirteen patients were given no information about bladder filing. Bladder, prostate, and rectum were contoured on CT and volumes were calculated. 3D conformal treatment planning was performed and effective volumes of bladder were calculated when a prescription dose of 70.2 Gy was delivered. For the patients in experimental group, bladder volumes were measured weekly using ultrasound scanner for 6-8 weeks and the bladder volume variations were analyzed. Results: Average bladder volumes and standard deviations obtained at CT scanning were $283.5{\pm}114.0\;cc$ (40%) and $181.2{\pm}120.1\;cc$ (66%) in experimental and control groups, respectively. Although it was not statistically significant, there was correlation between the bladder volumes measured from CT and ultrasound. The volumes measured using ultrasound scanner were 62% lower than the volumes using CT images on average. There was significant variations in volumes measured weekly for 6-8 weeks. It ranged between 33 - 75 %. Conclusion: Our results showed that it is possible to obtain larger bladder volume if they are asked to drink certain amount of water prior to CT scan. However, patients were unable to maintain constant bladder volumes over the 6-8 weeks of treatment period although they were asked to drink constant amount of water.

Survey on the Hospice Care Needs of Hospice Volunteers (호스피스 자원봉사자의 호스피스 케어 요구도 분석)

  • Cho, Hyun;Kang, Hee-Sook;Kim, Jeoung-Hee
    • Journal of Hospice and Palliative Care
    • /
    • v.5 no.2
    • /
    • pp.155-162
    • /
    • 2002
  • Purpose : The purpose of this study is to provide preliminary information on the hospice care needs of hospice volunteers. Methods : The sample of this study was obtained from those who completed the hospice volunteer education program in three different areas in Korea. This study was conducted by a self-administered questionnaire. The sample analyzed for this study contained 88 hospice volunteers. Frequency, percentage, mean, standard deviation, and logistic regression analysis were performed to produce the findings of this study. Results : The characteristics of the study sample were $40{\sim}49$ aged, middle class, christianity, married women with high school diplomas. They attended at the hospice center with less than 1 year experience. Majority of them had no family members who received a hospice care. The hospice care was strongly required in the field of information, particularly regarding their diseases and treatments. The identified hospice care needs were the prevention and treatment of gangrene in the field of physical needs, the maintenance of closer relationship with their doctors in the field of emotional needs, and the support of supporting medical insurance in the field of socioeconomic needs. The significant predictors were 'having hospice care taker among family members' in the field of the total hospice care needs and physical needs. Two predictable variables were found in the field of emotional needs. However, none were found to be a predictable variable in the field of information and socioeconomic needs. Conclusion : The findings or this study have a weekness of generalizability due to the sampling methodology used in this study. Thus, further research should be designed in relation to this topic with a probability sampling method.

  • PDF

Clinical Usefulness of PET-MRI in Lymph Node Metastasis Evaluation of Head and Neck Cancer (두경부암 림프절 전이 평가에서 PET-MRI의 임상적 유용성)

  • Kim, Jung-Soo;Lee, Hong-Jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.26-32
    • /
    • 2014
  • Purpose: As PET-MRI which has excellent soft tissue contrast is developed as integration system, many researches about clinical application are being conducted by comparing with existing display equipments. Because PET-MRI is actively used for head and neck cancer diagnosis in our hospital, lymph node metastasis before the patient's surgery was diagnosed and clinical usefulness of head and neck cancer PET-MRI scan was evaluated using pathological opinions and idiopathy surrounding tissue metastasis evaluation method. Materials and Methods: Targeting 100 head and neck cancer patients in SNUH from January to August in 2013. $^{18}F-FDG$ (5.18 MBq/kg) was intravenous injected and after 60 min of rest, torso (body TIM coil, Vibe-Dixon) and dedication (head-neck TIM coil, UTE, Dotarem injection) scans were conducted using $Bio-graph^{TM}$ mMR 3T (SIEMENS, Munich). Data were reorganized using iterative reconstruction and lymph node metastasis was read with Syngo.Via workstation. Subsequently, pathological observations and diagnosis before-and-after surgery were examined with integrated medical information system (EMR, best-care) in SNUH. Patient's diagnostic information was entered in each category of $2{\times}2$ decision matrix and was classified into true positive (TP), true negative (TN), false positive (FP) and false negative (FN). Based on these classified test results, sensitivity, specificity, accuracy, false negative and false positive rate were calculated. Results: In PET-MRI scan results of head and neck cancer patients, positive and negative cases of lymph node metastasis were 49 and 51 cases respectively and positive and negative lymph node metastasis through before-and-after surgery pathological results were 46 and 54 cases respectively. In both tests, TP which received positive lymph node metastasis were analyzed as 34 cases, FP which received positive lymph node metastasis in PET-MRI scan but received negative lymph node metastasis in pathological test were 4 cases, FN which received negative lymph node metastasis but received positive lymph node metastasis in pathological test was 1 case, and TN which received negative lymph node metastasis in both two tests were 50 cases. Based on these data, sensitivity in PET-MRI scan of head and neck cancer patient was identified to be 97.8%, specificity was 92.5%, accuracy was 95%, FN rate was 2.1% and FP rate was 7.00% respectively. Conclusion: PET-MRI which can apply the acquired functional information using high tissue contrast and various sequences was considered to be useful in determining the weapons before-and-after surgery in head and neck cancer diagnosis or in the evaluation of recurrence and remote detection of metastasis and uncertain idiopathy cervical lymph node metastasis. Additionally, clinical usefulness of PET-MRI through pathological test and integrated diagnosis and follow-up scan was considered to be sufficient as a standard diagnosis scan of head and neck cancer, and additional researches about the development of optimum MR sequence and clinical application are required.

  • PDF

Strategies for Public Health Service Development in the Times of Local Autonomy (지방자치시대의 공공보건사업 발전 전략)

  • 박정한
    • Health Policy and Management
    • /
    • v.12 no.3
    • /
    • pp.1-22
    • /
    • 2002
  • Health is a fundamental human right and a sine qua non for happiness of people and for national development. Government has a responsibility for the provision of health services for their people. Recent changes of disease pattern, i.e. decrease of Infectious diseases and increase of chronic and degenerative diseases Including cancer and cardiovascular diseases, together with universal coverage of health insurance and improved living standard have prompted medical care utilization and skyrocketed the national health expenses. The goal of national health policy is improving the quality of life through the betterment of health level. To achieve this goal it is necessary to establish a healthcare system for lifetime, to improve the efficiency of healthcare delivery system, and to strengthen the public health services for disease prevention and health promotion. The current public health service programs are Inefficient due to an inconsistent policy for health service program, lack of health information system, irrational health program planning and evaluation, and Inadequate training of health workers. Local government has a legal responsibility for health service program planning and promoting the competence of health workers. Thus, municipal and provincial health departments should expand their roles and strengthen their function. The strategies for developing public health service programs at local level are ${\circled}1$ stipulating the goals of health policy, ${\circled}2$ promoting the ability for health program planning and evaluation, ${\circled}3$ establishing health information and surveillance system, ${\circled}4$ training of health workers, ${\circled}5$ establishing an institution for health information management and training of health workers, and ${\circled}61$ collaboration with local universities.

Preservation of World Records Heritage in Korea and Further Registry (한국의 세계기록유산 보존 현황 및 과제)

  • Kim, Sung-Soo
    • Journal of Korean Society of Archives and Records Management
    • /
    • v.5 no.2
    • /
    • pp.27-48
    • /
    • 2005
  • This study investigates the current preservation and management of four records and documentary heritage in Korea that is in the UNESCO's Memory of the World Register. The study analyzes their problems and corresponding solutions in digitizing those world records heritages. This study also reviews additional four documentary books in Korea that are in the wish list to add to UNESCO's Memory of the World Register. This study is organized as the following: Chapter 2 examines the value and meanings of world records and documentary heritage in Korea. The registry requirements and procedures of UNESCO's Memory of the World Register are examined. The currently registered records of Korea include Hunmin-Chongum, the Annals of the Choson Dynasty, the Diaries of the Royal Secretariat (Seungjeongwon Ilgi), and Buljo- Jikji-Simche-Yojeol (vol. II). These records heritage's worth and significance are carefully analyzed. For example, Hunmin-Chongum("訓民正音") is consisted of unique and systematic letters. Letters were delicately explained with examples in its original manual at the time of letter's creation, which is an unparalleled case in the world documentary history. The Annals of the Choson Dynasty("朝鮮王朝實錄") are the most comprehensive historic documents that contain the longest period of time in history. Their truthfulness and reliability in describing history give credits to the annals. The Royal Secretariat Diary (called Seungjeongwon-Ilgi("承政院日記")) is the most voluminous primary resources in history, superior to the Annals of Choson Dynasty and Twenty Five Histories in China. Jikji("直指") is the oldest existing book published by movable metal print sets in the world. It evidences the beginning of metal printing in the world printing history and is worthy of being as world heritage. The review of the four registered records confirms that they are valuable world documentary heritage that transfers culture of mankind to next generations and should be preserved carefully and safely without deterioration or loss. Chapter 3 investigates the current status of preservation and management of three repositories that store the four registered records in Korea. The repositories include Kyujanggak Archives in Seoul National University, Pusan Records and Information Center of National Records and Archives Service, and Gansong Art Museum. The quality of their preservation and management are excellent in all of three institutions by the following aspects: 1) detailed security measures are close to perfection 2) archiving practices are very careful by using a special stack room in steady temperature and humidity and depositing it in stack or archival box made of paulownia tree and 3) fire prevention, lighting, and fumigation are thoroughly prepared. Chapter 4 summarizes the status quo of digitization projects of records heritage in Korea. The most important issue related to digitization and database construction on Korean records heritage is likely to set up the standardization of digitization processes and facilities. It is urgently necessary to develop comprehensive standard systems for digitization. Two institutions are closely interested in these tasks: 1) the National Records and Archives Service experienced in developing government records management systems; and 2) the Cultural Heritage Administration interested in digitization of Korean old documents. In collaboration of these two institutions, a new standard system will be designed for digitizing records heritage on Korean Studies. Chapter 5 deals with additional Korean records heritage in the wish list for UNESCO's Memory of the World Register, including: 1) Wooden Printing Blocks(經板) of Koryo-Taejangkyong(高麗大藏經) in Haein Temple(海印寺); 2) Dongui-Bogam("東醫寶鑑") 3) Samguk-Yusa("三國遺事") and 4) Mugujeonggwangdaedaranigyeong. Their world value and importance are examined as followings. Wooden Printing Blocks of Koryo-Taejangkyong in Haein Temple is the worldly oldest wooden printing block of cannon of Buddhism that still exist and was created over 750 years ago. It needs a special conservation treatment to disinfect germs residing in surface and inside of wooden plates. Otherwise, it may be damaged seriously. For its effective conservation and preservation, we hope that UNESCO and Government will schedule special care and budget and join the list of Memory of the Word Register. Dongui-Bogam is the most comprehensive and well-written medical book in the Korean history, summarizing all medical books in Korea and China from the Ancient Times through the early 17th century and concentrating on Korean herb medicine and prescriptions. It is proved as the best clinical guidebook in the 17th century for doctors and practitioners to easily use. The book was also published in China and Japan in the 18th century and greatly influenced the development of practical clinic and medical research in Asia at that time. This is why Dongui Bogam is in the wish list to register to the Memory of the World. Samguk-Yusa is evaluated as one of the most comprehensive history books and treasure sources in Korea, which illustrates foundations of Korean people and covers histories and cultures of ancient Korean peninsula and nearby countries. The book contains the oldest fixed form verse, called Hyang-Ka(鄕歌), and became the origin of Korean literature. In particular, the section of Gi-ee(紀異篇) describes the historical processes of dynasty transition from the first dynasty Gochosun(古朝鮮) to Goguryeo(高句麗) and illustrates the identity of Korean people from its historical origin. This book is worthy of adding to the Memory of the World Register. Mugujeonggwangdaedaranigyeong is the oldest book printed by wooden type plates, and it is estimated to print in between 706 and 751. It contains several reasons and evidence to be worthy of adding to the list of the Memory of the World. It is the greatest documentary heritage that represents the first wooden printing book that still exists in the world as well as illustrates the history of wooden printing in Korea.

Reproducibility of Regional Pulse Wave Velocity in Healthy Subjects

  • Im Jae-Joong;Lee, Nak-Bum;Rhee Moo-Yong;Na Sang-Hun;Kim, Young-Kwon;Lee, Myoung-Mook;Cockcroft John R.
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.4 no.2
    • /
    • pp.19-24
    • /
    • 2006
  • Background: Pulse wave velocity (PWV), which is inversely related to the distensibility of an arterial wall, offers a simple and potentially useful approach for an evaluation of cardiovascular diseases. In spite of the clinical importance and widespread use of PWV, there exist no standard either for pulse sensors or for system requirements for accurate pulse wave measurement. Objective of this study was to assess the reproducibility of PWV values using a newly developed PWV measurement system in healthy subjects prior to a large-scale clinical study. Methods: System used for the study was the PP-1000 (Hanbyul Meditech Co., Korea), which provides regional PWV values based on the measurements of electrocardiography (ECG), phonocardiography (PCG), and pulse waves from four different sites of arteries (carotid, femoral, radial, and dorsalis pedis) simultaneously. Seventeen healthy male subjects with a mean age of 33 years (ranges 22 to 52 years) without any cardiovascular disease were participated for the experiment. Two observers (observer A and B) performed two consecutive measurements from the same subject in a random order. For an evaluation of system reproducibility, two analyses (within-observer and between-observer) were performed, and expressed in terms of mean difference ${\pm}2SD$, as described by Bland and Altman plots. Results: Mean and SD of PWVs for aorta, arm, and leg were $7.07{\pm}1.48m/sec,\;8.43{\pm}1.14m/sec,\;and\;8.09{\pm}0.98m/sec$ measured from observer A and $6.76{\pm}1.00m/sec,\;7.97{\pm}0.80m/sec,\;and\;\7.97{\pm}0.72m/sec$ from observer B, respectively. Between-observer differences ($mean{\pm}2SD$) for aorta, arm, and leg were $0.14{\pm\}0.62m/sec,\;0.18{\pm\}0.84m/sec,\;and\;0.07{\pm}0.86m/sec$, and the correlation coefficients were high especially 0.93 for aortic PWV. Within-observer differences ($mean{\pm}2SD$) for aorta, arm, and leg were $0.01{\pm}0.26m/sec,\;0.02{\pm}0.26m/sec,\;and\;0.08{\pm}0.32m/sec$ from observer A and $0.01{\pm}0.24m/sec,\;0.04{\pm}0.28m/sec,\;and\;0.01{\pm}0.20m/sec$ from observer B, respectively. All the measurements showed significantly high correlation coefficients ranges from 0.94 to 0.99. Conclusion: PWV measurement system used for the study offers comfortable and simple operation and provides accurate analysis results with high reproducibility. Since the reproducibility of the measurement is critical for the diagnosis in clinical use, it is necessary to provide an accurate algorithm for the detection of additional features such as flow wave, reflection wave, and dicrotic notch from a pulse waveform. This study will be extended for the comparison of PWV values from patients with various vascular risks for clinical application. Data acquired from the study could be used for the determination of the appropriate sample size for further studies relating various types of arteriosclerosis-related vascular disease.

  • PDF

CT Examinations for COVID-19: A Systematic Review of Protocols, Radiation Dose, and Numbers Needed to Diagnose and Predict (COVID-19 진단을 위한 CT 검사: 프로토콜, 방사선량에 대한 체계적 문헌고찰 및 진단을 위한 CT 검사량)

  • Jong Hyuk Lee;Hyunsook Hong;Hyungjin Kim;Chang Hyun Lee;Jin Mo Goo;Soon Ho Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.6
    • /
    • pp.1505-1523
    • /
    • 2021
  • Purpose Although chest CT has been discussed as a first-line test for coronavirus disease 2019 (COVID-19), little research has explored the implications of CT exposure in the population. To review chest CT protocols and radiation doses in COVID-19 publications and explore the number needed to diagnose (NND) and the number needed to predict (NNP) if CT is used as a first-line test. Materials and Methods We searched nine highly cited radiology journals to identify studies discussing the CT-based diagnosis of COVID-19 pneumonia. Study-level information on the CT protocol and radiation dose was collected, and the doses were compared with each national diagnostic reference level (DRL). The NND and NNP, which depends on the test positive rate (TPR), were calculated, given a CT sensitivity of 94% (95% confidence interval [CI]: 91%-96%) and specificity of 37% (95% CI: 26%-50%), and applied to the early outbreak in Wuhan, New York, and Italy. Results From 86 studies, the CT protocol and radiation dose were reported in 81 (94.2%) and 17 studies (19.8%), respectively. Low-dose chest CT was used more than twice as often as standard-dose chest CT (39.5% vs.18.6%), while the remaining studies (44.2%) did not provide relevant information. The radiation doses were lower than the national DRLs in 15 of the 17 studies (88.2%) that reported doses. The NND was 3.2 scans (95% CI: 2.2-6.0). The NNPs at TPRs of 50%, 25%, 10%, and 5% were 2.2, 3.6, 8.0, 15.5 scans, respectively. In Wuhan, 35418 (TPR, 58%; 95% CI: 27710-56755) to 44840 (TPR, 38%; 95% CI: 35161-68164) individuals were estimated to have undergone CT examinations to diagnose 17365 patients. During the early surge in New York and Italy, daily NNDs changed up to 5.4 and 10.9 times, respectively, within 10 weeks. Conclusion Low-dose CT protocols were described in less than half of COVID-19 publications, and radiation doses were frequently lacking. The number of populations involved in a first-line diagnostic CT test could vary dynamically according to daily TPR; therefore, caution is required in future planning.

Metal artifact SUV estimation by using attenuation correction image and non attenuation correction image in PET-CT (PET-CT에서 감쇠보정 영상과 비감쇠보정 영상을 통한 Metal Artifact 보정에 대한 고찰)

  • Kim, June;Kim, Jae-II;Lee, Hong-Jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.21-26
    • /
    • 2016
  • Purpose Because of many advantages, PET-CT Scanners generally use CT Data for attenuation correction. By using CT based attenuation correction, we can get anatomical information, reduce scan time and make more accurate correction of attenuation. However in case metal artifact occurred during CT scan, CT-based attenuation correction can induce artifacts and quantitative errors that can affect the PET images. Therefore this study infers true SUV of metal artifact region from attenuation corrected image count -to- non attenuation corrected image count ratio. Materials and Methods Micro phantom inserted $^{18}F-FDG$ 4mCi was used for phantom test and Biograph mCT S(40) is used for medical test equipment. We generated metal artifact in micro phantom by using metal. Then we acquired both metal artifact region of correction factor and non metal artifact region of correction factor by using attenuation correction image count -to- non attenuation correction image count ratio. In case of clinical image, we reconstructed both attenuation corrected images and non attenuation corrected images of 10 normal patient($66{\pm}15age$) who examined PET-CT scan in SNUH. After that, we standardize several organs of correction factor by using attenuation corrected image count -to- non attenuation corrected count ratio. Then we figured out metal artifact region of correction factor by using metal artifact region of attenuation corrected image count -to- non attenuation corrected count ratio And we compared standard organs correction factor with metal artifact region correction factor. Results according to phantom test results, metal artifact induce overestimation of correction factor so metal artifact region of correction factors are 12% bigger than the non metal artifact region of correction factors. in case of clinical test, correction factor of organs with high CT number(>1000) is $8{\pm}0.5%$, correction factor of organs with CT number similar to soft tissue is $6{\pm}2%$ and correction factor of organs with low CT number(-100>) is $3{\pm}1%$. Also metal artifact correction factors are 20% bigger than soft tissue correction factors which didn't happened metal artifact. Conclusion metal artifact lead to overestimation of attenuation coefficient. because of that, SUV of metal artifact region is overestimated. Thus for more accurate quantitative evaluation, using attenuation correction image count -to-non attenuation correction image count ratio is one of the methods to reduce metal artifact affect.