• 제목/요약/키워드: medical fibers

검색결과 218건 처리시간 0.024초

설신경과 장협신경 전달마취 시행 후 발생된 설부와 협선반부의 장기간 이상감각증 관리 -증례보고- (The Persistent Paresthesia Care on Left Lingual & Buccal Shelf Regions after the Lingual & Long Buccal Nerve Block Anesthesia -A Case Report-)

  • 김하랑;유재하;최병호;모동엽;이천의;김종배
    • 대한치과마취과학회지
    • /
    • 제9권2호
    • /
    • pp.108-115
    • /
    • 2009
  • Trauma to any nerve may lead to persistent paresthesia. Trauma to the nerve sheath can be produced by the needle. The patient frequently reports the sensation of an electric shock throughout the distribution of the nerve involved. It is difficult for the type of needle used in dental practice to actually sever a nerve trunk or even its fibers. Trauma to the nerve produced by contact with the needle is all that is needed to produce paresthesia. Hemorrhage into or around the neural sheath is another cause. Bleeding increases pressure on the nerve, leading to paresthesia. Injection of local anesthetic solutions contaminated by alcohol or sterilizing solution near a nerve produces irritation; the resulting edema increases pressure in the region of the nerve, leading to paresthesia. Persistent paresthesia can lead to injury to adjacent tissues. Biting or thermal or chemical insult can occur without a patient's awareness, until the process has progressed to a serious degree. Most paresthesias resolve in approximately 8 weeks without treatment. In most situations paresthesia is only minimal, with the patient retaining most sensory function to the affected area. In these cases there is only a very slight possibility of self injury. But, the patient complaints the discomfort symptoms of paresthesia, such as causalgia, neuralgiaform pain and anesthesia dolorosa. Most paresthesias involve the lingual nerve, with the inferior alveolar nerve a close second. This is the report of a case, that had the persistent paresthesia care on left lingual & buccal shelf regions after the lingual and long buccal nerve block anesthesia.

  • PDF

혈관 내 폐 보조장치의 압력손실 예측을 위한 모델링기법에 관한 연구 (Study on the Modeling Technique for Prediction about Pressure Drop of an Intravenous Lung Assist Device)

  • 김기범;권대규;정경락
    • 대한의용생체공학회:의공학회지
    • /
    • 제24권4호
    • /
    • pp.293-299
    • /
    • 2003
  • 본 연구에서는 혈관 내 폐 보조장치(Vibrating Intravascular Lung Assist Device. VIVLAD)에서의 뉴우튼 유체와 비뉴우튼 유체의 압력손실관계에 대한 관계를 고찰하고자 하였으며, VIVLAD를 선계하기 위한 압력 강하를 예측할 수 있는 관계식을 결정하고자 하였다. 혈관 내 폐 보조장치를 정맥에 삽입하기 전, 모듈 설계를 위하여 압력손실을 예측하기 위한 설계조건을 실험적 모델을 통하여 연구하고자 하였다. 뉴우튼 유체로 증류수와 글리세롤/증류수 혼합용액을 이용하였으며, 비뉴우튼 유체는 혈액을 이용하여 실험을 수행하였다. 액체의 흐름은 중공사의 외부로 평행하게 흐르도록 하였다. 내경의 직경을 3cm로 고정한 관에 삽입되는 중공사 개수의 변화에 파른 압력손실을 측정하였으며 실험에 의하여 얻어진 압력손실과 중공사의 전면면적과의 상관관계를 curve fitting을 통하여 유도하였고 유도되어진 관계식을 이용하여 관내에 삽입되는 중공사 개수의 변화에 따른 압력손실을 예측하였다 그리고 실험을 통하여 예측되어진 값과 비교 검토하여 유사성을 찾고자 하였다. 실험결과 40%글리세롤 용액에서의 압력손실과 혈액에서의 압력손실과 마찰계수는 유사한 결과를 보였다. 이 실험에서 VIVLAD의 압력손실을 측정하는데 40%글리세롤 용액이 이용될 수 있음을 보였다 또한 장치 내에서의 압력손실과 마찰계수에 대한 관계식을 중공사 충진율의 함수로 관계식을 유도할 수 있었으며. 관계식에 의하여 압력손실을 예측할 수 있었다. 또한. 실험에 의한 압력손실과 비교하였을 때 유사한 경향성을 보여 줌으로써 압력손실 예측의 신뢰성을 얻을 수 있었다. 이와 같은 연구결과는 VIVLAD를 설계하는데 유용한 자료가 될 것이다.

티벳의학에 대한 연구 - "사부의전(四部醫典).근본의전(根本醫典)"을 중심으로 (Study on "Four Tantras", the Prime Textbook of Tibetan Medicine)

  • 장은영;윤창열
    • 대한한의학원전학회지
    • /
    • 제11권1호
    • /
    • pp.416-512
    • /
    • 1998
  • The following conclusions are obtained from the studies on the chapters concerning phisiology, pathology, daily conduct, materia medica, pulse, and urinalysis from , of the "Four Tantras". 1. The theoretical basis forming the Tibetan Medicine is the substance of phlegm, bile, and wind each of which is divided into five kinds. These phisiological substances can be transformed into pathological factors when certain environment is formed. 2. In embryology, the semen of the father and menstral blood of mother is considered the most important condition in conception, and the Five factors are regarded as important. There is a detailed explanation of development of the fetus while it stays in the womb of mother during 38weeks, such as the formation of the viscera, channels, sense organs, etc. 3. There is metaphor which compares the human body with the king's palace. With the development of human anatomy, there is the detailed anatomical picture of anterior and posterior aspects of human body. And also there is the measurement of physiological constitution and the three fluids. 4. In division of the channels, they concerned the now of the blood and distribution of the nerve fibers, and each channel is connected with one another. The division of the cannel is namely embryonic channel, channel of existence, channel of connection, and the course of life principle. 5. The seven bodily constituents and three factors of phlegm, bile, and wind are important in sustaining the life of human body as well as growth and maturization, and when their equilibrium is broken, the human body is degnerated, and finally death comes. 6. The signs of death is divided into distant sign, remote sign, certain sign. and uncertain sign, and is used as a clue in diagnosis of the disease. Especially there is a mention about the mechanism of the dreams, and different dreams according to the condition of the patient. 7. In pathology, there is the cause of the disease, the environmental factors which can induce disease, the path by which disease come into the human body, the characteristics of the disease, and the kinds of disease. 8. There is a mention about the conduct, and it is divided into the daily conduct, the mental attitude, and the side-effects which can occur when one puts up with the physiological actions of the body. 9. The daily diet is divided into food and beverage. The food is divided again into grain, meat, fat, boiled food, and spiced food, and the beverage into milk, water, and wine. 10. The pulsation should be taken in lift hand to diagnose heart, small intestine, stomach, spleen, kidney, reproductive organ, and in right hand jungs, large intestine, liver, gall bladder, kidney, and bladder. In the healthy person, the pulse moves 5times in one perspiration, and the type of pulse is constant while the pulse moves 100times. But unhealthy person's pulse is different from this. The urinalysis is the unique part of Tibetan Medicine, and is important in examination of the disease. One should decide which of the three factors are dominant by the obervation of the color, amount of the steam and how long it lasts, odour, foam, and the shape of the swirl in three different states when the urine is hot, warm, and cold. One can determine the life of the patient and which viscera is the cause of the disease by the pulse, and whether the nature of the disease is hot or cold by the urinalysis. 11. The materia medica contains gemstones, minerals, plateau medication, and meat products.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

수종의 고정성 보정장치에 따른 유성견의 치주조직 반응 (Periodontal Tissue Response Following Different Types of Fixed Retainers in Young Adult Dogs)

  • 조명훈;윤영주;김광원
    • 대한치과교정학회지
    • /
    • 제31권1호
    • /
    • pp.85-95
    • /
    • 2001
  • 교정력을 가한 후 각기 다른 재료로 제작된 고정성 보정장치를 적용한 경우에 발생하는 치주조직의 재형성과 치유과정을 조직학적으로 관찰하기 위해 건강한 치주상태를 가진 네 마리의 유성견을 대상으로 최초 교정력이 200gm이 되도록 견인 스프링 (sentalloy closed coil $spring^{\circledR}$, Tomy Co., Japan)을 대상 치아에 결찰하여 1주일 간 교정력 을 가한 후 각각의 실험동물에 3가닥 호선인 0.018인치 $Dentaflex^{\circledR}$(Dentarum Co., Germany), 3가닥 호선인 0.020인치 $Dentaflex^{\circledR}$(Dentarum Co. Germany), 5가닥 호선인 0.0195인치 $Respond^{\circledR}$(G&H Co., U.S.A.)를, 그리고 자가중합형 레진 접착제인 Superbond $C&B^{\circledR}$를 고정성 보정장치의 재료를 이용하여 보정장치를 접착한 군과 보정장치를 접착하지 않은 군으로 나누어 3주간 적용 후 희생하여 H-E 염색군, M-T 염색군으로 나누어 광학현미경으로 관찰하여 다음과 같은 결과를 얻었다. 1. 0.0195인치 $Respond^{\circledR}$를 접착시킨 군은 0.018인치 $Dentaflex^{\circledR}$, 0.020인치 $Dentaflex^{\circledR}$, Superbond $C&B^{\circledR}$를 접착시킨 군에 비교할 때 압박측에서의 거대세포 침윤 감소와 긴장측에서의 신생골 형성 증가가 매우 두드러지게 나타났으며 치주인대는 형태와 배열에서 대부분 정상적인 소견을 보였다. 2. 실험 1군의 모든 실험대상에서 압박측 치조골 내부의 괴사골이 관찰되었고, 압박측과 긴장측 모두에서 치조골 표면의 골양조직 및 sharpey 섬유의 형성과 치주인대의 재형성 현상이 나타나는 것이 관찰되었다. 3. 실험 2군은 실험 1군에 비교하여 압박측에서 거대세포 침윤이 현저히 감소되었고 치주인대는 거의 정상적인 소견을 보였다. 긴장측에서는 수층의 골침착을 보이며 치주인대 측으로 골양조직과 골아세포가 구상으로 나타나는 활성화 소견을 보였다. 이상의 결과에서 더 여러 가닥이 꼬인 6가닥 호선인 0.0195인치 $Respond^{\circledR}$(G&H Co., U.S.A.)를 보정장치로 적용한 경우가 다른 재료의 고정성 보정장치보다 더 활발한 신생골주 형성의 활성화 소견이 관찰되었으며 대조군과 유사한 배열과 형태를 보이는 정상적인 치주인대 섬유의 배열양상이 관찰되어 다른 재료들에 비교하여 치주조직의 초기 재형성 과정을 더 신속하게 유도하는 것으로 사료된다.

  • PDF

돼지의 심낭, 판막을 이용한 이종이식 보철편의 개발(고정 방법에 따른 조직학적 분석) (Development of Porcine Pericardial Heterograft for Clinical Application (Microscopic Analysis of Various Fixation Methods))

  • 김관창;최창휴;이창하;이철;오삼세;박성식;김웅한;김경환;김용진
    • Journal of Chest Surgery
    • /
    • 제41권3호
    • /
    • pp.295-304
    • /
    • 2008
  • 배경: 지금까지 심장 및 혈관 등의 결손을 교정하기 위하여 자기 조직이 아닌 다른 보철편의 필요가 증가함에 따라, 그에 따른 다양한 대체제가 연구 개발되고 있으며, 임상에서 실제로 흔히 이용되고 있다. 본 연구는 새로운 조직의 처리방법을 개발하기 위하여 이미 상용화되고 있는 기존의 일부 이종이식 보철편들과, 여러 가지 조건들에서 제조되는 이종조직인 돼지 심낭과 대동맥, 페동맥판막 등의 보철편들의 임상적용 전에 각종 고정, 처리 방법에 따른 이종조직의 조직학적 변성이나 변화의 가능성을, 물리적, 구조적, 기능적 치적의 상태를 분석하기 위하여 광학 현미경 및 전자 현미경 소견을 통하여 알아보고자 하였다. 대상 및 방법: 1) 0.625% glutaraldehyde용액에 고정 전과 고정 후의 돼지 심낭과 대동맥, 폐동맥판막, 사람의 심낭, 그리고 상용화되고 있는 기존의 이종이식 보철편들과 광학 및 전자현미경으로 비교관찰 하였다. 2) 돼지 심낭과 대동맥, 페동맥판막을 0.625% glutaraldehyde 고정 전과 고정 후에 80% Ethanol 처리한 군과, sodium dodecylsulfate (SDS) 을 이용하여 무세포화 처리만 시행한 군, 무세포화과정 후에 0.625% glutaraldehyde 고정한 군, 80% ethanol 처리 후 다시 무세포화과정을 한 후 0.625% glutaraldehyde 고정한 군, 무세포화한 후 다시 ethanol 처리 후 다시 0.625% glutaraldehyde 고정한 군으로 나누어 각각을 광학 및 전자현미경으로 관찰하였다 결과: 1) 돼지 심낭은 장막 층(serosal layer), 섬유층(fibrosa), 심외막 결합조직(epicardial connective tissue)로 이루어져 있었으며, 여러 가지 처치 후에도 모두 콜라겐 섬유는 잘 유지되고 있었다. 하지만 무세포화만 시행하거나 먼저 무세포화 처리한 군의 콜라겐구조는 다른 군에 비해 느슨하게 연결된(loosely condensed) 양상이었다. 기존의 소나 돼지의 심낭으로 만들어진 Shelhign, Biocor, Supple Peri-guard 등의 제품들의 콜라겐 섬유는 비교적 잘 유지되고 있었다. 2) 돼지 대동맥, 폐동맥 판막은 섬유판(lamina fibrosa), 해면질판(lamina spongiosa), 심실판(lamina ventricularis) 세층으로 이루어져 있었으며 이 판막들은 여러 가지 처치 후에도 모두 세층과 콜라겐 섬유는 잘 유지되고 있었다. 하지만 무세포화만 시행하거나 민저 처리한 군은 신낭에서 처럼 콜라겐구조는 다른 군에 비해 약간 느슨하게 연결된(loosely condensed) 양상이었다. 돼지 대동맥판막으로 만들어진 Carpentier Edwards, Medtronics, Shelhigh, Biocor의 다른 제품들도 세 개의 층은 잘 유지되었고 콜라겐도 잘 유지되고 있었다. 결론: 이종이식 돼지심낭과 대동맥 판막, 폐동맥 판막 보철편은 여러 조건하의 고정 방법들에 따라 광학 및 전자 현미경적 구조의 확연한 차이를 보이지 않아, Glutaraldehyde를 이용한 각종 조직 처리과정 중 조직손상에 의한 구조적, 기계적손실은 없는 것으로 생각되며, sodium dodecylsulfate (SDS)을 이용하여 무세포화 처리를 시행한 경우 대부분의 보철편에서 콜라겐 조직의 미세한 변성이나 분해(degradation)가 광학 및 전자현미경에서 관찰되어, 무세포화의 처리방법이나 조건의 적절화가 필요한 것으로 생각되었다.

표지방식을 이용한 흰 쥐 복강 내장을 지배하는 감각신경세포체와 신경섬유의 표지부위 (Localization of Sensory Neurons Innervating the Rat Intestine Using the Cholera Toxin B Subunit(CTB) and Wheat Germ Agglutinin-Horseradish Peroxidase(WGA-HRP))

  • 이동협;이창현;이무삼
    • Journal of Yeungnam Medical Science
    • /
    • 제15권1호
    • /
    • pp.75-96
    • /
    • 1998
  • 복강내장을 지배하는 감각신경세포체 및 신경섬유의 표지부위를 관찰하기 위하여 복강내장을 부위별(위, 십이지장, 공장, 회장, 맹장, 오름결장, 내림결장)로 나누어 2.5% WGA-HRP $30{\mu}l$와 0.5% CTB $20{\mu}l$를 장막과 근육층 사이의 4부위에 나누어 주입하였다. 그 후 48-96시간의 생존시간이 경과한 후 뇌줄기, 척수신경절과 미주신경절에서의 감각신경섬유와 신경세포체의 표지부위를 면역조직화학 염색법과 HRP 조직화학 기법으로 관찰한 결과는 다음과 같다. 1. WGA-HRP에 표지된 감각신경섬유는 위와 맹장에서만 관찰되었으며, CTB에 표지된 감각신경섬유는 복강내장의 모든 장기에서 관찰되었다. 2. 복강내장을 지배하는 감각신경섬유는 뇌줄기내 좌우 고립로핵의 교질부, 교질부의 등쪽내측부, 교차연결부, 내측부, 넷째뇌실벽, 맨아래구역의 앞쪽경계 및 중심관의 등쪽 정중선인 교차연결부에 국소적으로 강하게 표지되었다. 3. 척수신경절에서 위 (stomach)에 분포하는 감각신경세포체는 좌우 관계없이 $T_2$에서 $L_1$까지 여러 신경절에 표지되었으며 이 중 좌우 $T_{8-9}$부위에 가장 많이 표지되었다. 4. 십이지장에서의 척수신경절에 표지된 감각 신경세포체는 좌우 $T_6-L_2$부위에 표지되었으나 다른 장기에 비하여 표지된 감각신경세포체의 수는 적었다. 5. 공장에서의 척수신경절에 표지된 감각신경세포체는 좌우 $T_6-L_2$부위에 표지되었다. 가장 많이 표지된 부위는 좌측 $T_{12}$ 부위였으며, 우측은 $T_{13}$ 부위에 표지되었다. 6. 회장에서의 척수신경절에 표지된 감각신경세포체는 좌우 $T_6-L_2$부위였다. 가장 많이 표지된 부위는 좌측에서 $T_{11}$부위였고, 우측에서 $L_1$부위였다. 7. 맹장에서의 척수신경절에 표지된 감각신경 세포체는 좌측은 $T_7-L_2$부위였으며 우측은 $T_6-L_1$부위였다. 가장 많이 표지된 부위는 좌측은 $T_{11}$이었으며, 우측은 $T_{11-12}$에 표지되었다. 8. 오름결장에서 척수신경절에 표지된 감각신경세포체는 좌측은 $T_7-L_2$부위에 표지되었고 우측은 $T_9-L_4$부위에 표지되어 좌우측 표지부위의 차이를 보였다. 가장 많이 표지된 부위는 좌측은 $T_9$이었으며, 우측은 $T_{11}$에 표지되었다. 9. 내림결장에서 척수신경절에 표지된 감각신경 세포체는 좌측은 $T_9-L_2$부위에 표지되었고 우측은 $T_6-L_2$부위에 표지되었다. 가장 많이 표지된 부위는 좌측은 $T_{13}$이었으며, 우측은 $L_1$에 표지되었다. 10. 복강내장을 지배하는 좌우 미주신경절에 표지된 감각신경세포체는 위에서 가장 많이 표지되었으며 위를 제외한 나머지 장기에서는 표지된 감각신경세포체의 수는 위에 표지된 수보다 적었다. 이상의 결과로 흰쥐의 복강내장을 지배하는 감각신경섬유의 뇌줄기내 표지영역은 좌우 고립로 핵의 교질부, 교질부의 등쪽내측부, 교차연결부, 내측부, 넷째뇌실벽, 맨아래구역의 앞쪽경계 및 중심관의 등쪽 정중선인 교차연결부였으며, 감각신경세포체의 표지영역은 미주신경절과 척수신경절 $T_2-L_4$ 부위였음을 알 수 있었다. 위를 제외한 나머지 장기들에서는 $T_6-L_4$부위에 표지되었으나 소장에서 대장으로 갈수록 가장 많이 표지된 부위는 원위부 가슴신경절에서 근위부 허리신경절쪽으로 이동하는 경향을 보였다.

  • PDF