• Title/Summary/Keyword: medical electrical equipment

Search Result 110, Processing Time 0.04 seconds

A Study on an Improvement Scheme of ISM Management Regulation (전파응용설비 관리제도 개선방안 연구)

  • Park, Yeon-Gyu;Cho, Hyun-Mook;Lee, Il-Kyoo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.7
    • /
    • pp.581-587
    • /
    • 2016
  • Recently, ISM(Industrial, Scientific and Medical) equipments that exceed 50 watts were expended at home, medical institutions and industrial sites. Therefore, the equipments that are subject to permission have been significantly increased. So, the present permission system that individually permits each equipment and inspects all equipments has a limitation. Thus, it is also difficult to reflect the environmental changes. In this paper, we reviewed the ISM management system in major foreign countries and domestic, and then proposed an improvement scheme of ISM management system for domestic environment. These results will be useful for revitalization of domestic industry related to ISM equipment and an efficient management of ISM equipments in the future.

Job Analysis of Ubiquitous Medical Electronic Device Export by the Method of DACUM (DACUM 법을 활용한 유비쿼터스 의료전자기기 전문가의 직무분석)

  • Cho, Dong-Heon;Koo, Kyung-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.8
    • /
    • pp.1192-1197
    • /
    • 2013
  • In this paper Ubiquitous Medical Electronic Device Export was defined, and it's job analysis. The authors have been defined the job and classified duties and tasks of Ubiquitous Medical Electronic Device Export. To fine what is the most efficient task for Ubiquitous Medical Electronic Device Export, we have been investigated the levels of importance, difficulty, frequency and entry in each task. A DACUM committee is composed of total 12 members, which are one facilitator, 10 panel members, one coordinator & recorder to analyze the job of Ubiquitous Medical Electronic Device Export. Following is the result of this study. First, The process began with the identification of a job title and definition of Ubiquitous Medical Electronic Device Export. Second, a job model of Ubiquitous Medical Electronic Device Export is constructed based on the results of DACUM job analysis. 5 duties and 33 tasks are analyzed. Third, occupational specification was drawn up in consultation with SME council. Fourth, duty specification was drawn up in consultation. 33 tasks that are essential in entry level of occupation are identified. Fifth, task specification was drawn up in consultation. Detail task component which include skill, materials, knowledge, equipment, achievement level and tool was specified in task specification.

Analysis of Output Characteristics and Frequency Variation Design for Personal High Frequency Electrical Stimulation Medical Devices (개인용 고주파 전기자극기의 주파수 가변 설계 및 출력 특성의 분석)

  • Jang, Kyeong-Wook;Leem, Ji-Hyun;Baek, Seung-Myoung;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.1
    • /
    • pp.25-30
    • /
    • 2016
  • In this paper, personal electrical stimulation medcial devices using bioelectrical stimulating was developed. Therapy effect of RET(resistive electric transfer) was more effective than CET(capacitive electric transfer), but CET was adopted because of safety issue. Then, the optimum parameters that may be effective in thin skin or facial wrinkles was set. For example, the frequency of the pulse voltage for stimulation is 1.8[MHz], burst frequency is 7[kHz] or 400[Hz], the development of devices was to have ON/OFF control and frequency control. When burst frequency was adjusted 7[kHz], heat was generated in the electrode. The case of 400[Hz] the heat was little generated. The microcontroller ATmega128-based experimental results show that the proposed personal high frequency electrical stimulation devices can be applied to medical equipment using therapy effect successfully.

The effect of 470nm LED Irradiation on skin injury of RAT (470nm LED 광이 RAT 피부결손에 미치는 효과)

  • Cheon, Min-Woo;Kim, Seong-Hwan;Park, Yong-Pil;Lee, Ho-Shik;Kim, Young-Pyo;Kim, Tae-Gon;Lee, Hee-Keb
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.416-417
    • /
    • 2008
  • This paper performed the basic study for developing the Photodynamic Therapy Equipment for medical treatment. We developed the 4channel light medical therapy apparatus for external injury cure using a LED light source. This equipment was fabricated by using microcontroller, and designed to enable us to control light irradiation timer, intensity and reservation. In this paper, the designed device was used to find out how 470nm LEDs light source affects the skin wound of RAT. In the experiment, $1cm_2$ wounds on the External injury of RAT were made. Light irradiation RAT and none light irradiation RAT divided, each RAT was irradiated one hour a day for 15 days. In result, compared with none light irradiation RAT, the lower incidence of inflammation and faster recovery was shown in light irradiation RAT.

  • PDF

Study of Circuit Analysis & Application for Isolated Power System for the medically used rooms (의료실의 비접지 배선방식 회로해석 및 적용에 관한 연구)

  • Kim, Young-Bae
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.89-93
    • /
    • 2005
  • Today, the sciences in medical and nursing fields are becoming progressively more dependent on electrical apparatus for the preservation of life of hospitalized patients. Therefore, it is required more safety medical power distribution system in order to protect patients and physicians more securely from unexpected leakage of current. Especially for the medically used rooms which use life sustaining equipment, power should be provided as supplying continuously without interrupting with lowest leakage current. This thesis proposed the reason why Isolation Power System is safety through the circuit analysis and applications.

  • PDF

Analysis of Level Characteristics of 630nm Light Emitting Diode Module (630nm Light Emitting Diode 모듈의 레벨 특성 평가)

  • Kim, Tae-Gon;Cheon, Min-Woo;Park, Yong-Pil;Kim, Seong-Hwan;Song, Chang-Hun;Kim, Young-Su
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.347-348
    • /
    • 2006
  • This paper performed the basic study for developing the Photodynamic Therapy Equipment for medical treatment. The equipment have been manufactured by using the High Bright Light Emitting Diode and TLC5941 integrated circuit. As a result, 630nm Light Emitting Diode Module was made for the optimization of irradiation condition. And we confirmed the current change according to increase of the level of Light Emitting Diode Module.

  • PDF

Exposure Does of X-ray Generator on Full Wave Rectification Method (전파정류 방식의 X선 발생장치에서 조사선량)

  • Kim, Tae-Gon;Kim, Young-Pyo;Cheon, Min-Woo;Lee, Ho-Shik;Park, Yong-Pil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.138-138
    • /
    • 2010
  • X-ray systems for medical treatment use noninvasive procedures. I fabricated a high tension generator of a full-wave rectification type using a LC resonant inviter. It is said that a full-wave rectifying X-ray equipment such as the fabricated system can shorten initiating period and be precision control because of stable output, compared with the X-ray equipment of a half wave rectifying type used in the usual clinical medicine. In order to evaluate the capability of the fabricated high tension generator, I performed exposure dose characteristics experiments.

  • PDF

Amendment of the Inspection Standard for Diagnostic Radiation Equipment Applying IEC 60601-1-3: Medical Electrical Equipment - Part 1-3: General Requirements for Basic Safety and Essential Performance - Collateral Standard: Radiation Protection in Diagnostic X-ray Equipment (KS C IEC60601-1-3: 의료용 전기기기-제1-3부: 기본 안전 및 필수 성능에 관한 일반 요구사항-보조표준: 진단용 X선 장치의 방사선 방어를 적용한 진단용 방사선 발생장치의 검사기준 개선안)

  • Park, Hye-Min;Kim, Jung-Min;Kim, Jung-Su;Kim, Seong-Ok;Choi, Young-Min
    • Journal of radiological science and technology
    • /
    • v.41 no.5
    • /
    • pp.493-504
    • /
    • 2018
  • The diagnostic radiation equipment is managed in accordance with the "Rules for Safety Management of Diagnostic Radiation Equipment" enacted in 1995. The equipments should be inspected before use and every three years after use in accordance with the [Appendix 1] of the same rule. The inspection standard has been maintained without particular revision since enacted. But, over the past two decades new types of equipments have been manufactured and used. So, it is necessary to revise [Appendix 1] by making inspection items and inspection standards. In this study, we revised the classification system of equipments and reviewed international standards of IEC 60601 series, IEC 61223 series and AAPM TG 18 On-line Report No.03. And identified the problem of current inspection standards. Through this, we revised, deleted and added the inspection items and inspection standard of each equipment to meet the domestic circumstances. As a result of the study, we reorganized the classification system of equipment which are current classified as 5 classes into 22 classes as X-ray system etc. (7 classes), CT system etc. (5 classes) and Dental X-ray system etc. (10 classes). And then, we developed 70 inspection items for 6 types of equipments according to the reorganized classification system of equipments. The inspection items and inspection standards derived from this study have been proposed to the KCDC and will be applied to the revision of the Rule's [Appendix 1]. Therefore, we expect to be used as reference materials for domestic medical center, inspection institutions, and equipment manufacturing import companies.

Development of Three-Phase Line-Interactive Dynamic Voltage Restorer with Hybrid Detection Method (Hybrid 검출방식을 적용한 삼상 선로 응동형 DVR(Dynamic Voltage Restorer))

  • Jeong, Jong-Kyou;Han, Byung-Moon
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.901_902
    • /
    • 2009
  • This paper describes the development of a three-phase Line-Interactive DVR(Dynamic Voltage Restorer), which is applied to Hybrid detection method and super-capacitor. The operational feasibility was verified through computer simulations with PSCAD/EMTDC software, and experimental will be work with 3kVA prototype. The developed system can compensates the input voltage sag and interruption within 2ms, in which the maximum allowable sensitive load, such as computer, communication equipment, automation equipment, and medical equipment. The developed system has a simple structure to be easily implemented with commercially available components and to be highly reliable in operation.

  • PDF

Development of Single-Phase DVR(Dynamic Voltage Restorer) Composed of H-Bridge Inverter and SuperCapacitor (H-브리지 인버터와 수퍼커패시터로 구성된 단상 DVR(Dynamic Voltage Restorer)의 개발)

  • Lee, Dong-Geun;Lee, Doo-Young;Yang, Seung-Chul;Bae, Byung-Yeol;Han, Byung-Moon
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.160-161
    • /
    • 2007
  • This paper describes the development of a single-phase DVR(Dynamic voltage Restorer), which is composed of H-bridge inverter and super-capacitors. The operational feasibility was verified through computer simulations with PSCAD/EMTDC software, and experimental works with 3kVA prototype. The developed system can compensates the input voltage sag and interruption within 2ms, in which the maximum allowable duration of voltage interruption is 1.5 seconds. It can be effectively used to compensate the voltage interruption in the sensitive load, such as computer, communication equipment, automation equipment, and medical equipment. The developed system has a simple structure to be easily implemented with commercially available components and to be highly reliable in operation.

  • PDF