• Title/Summary/Keyword: medical diagnostics

Search Result 373, Processing Time 0.019 seconds

Quality Assessment and Comparison of Several Radioimmunoassay Kits and Chemiluminescence Immunoassay Methods for Evaluating Serum Estradiol (혈중 Estradiol 농도 측정을 위한 여러 방사면역측정 검사키트 및 화학면역발광 검사법의 성능평가 및 상호비교)

  • Choi, Sung Hee;Noh, Gyeong Woon;Kim, Jin Eui;Song, Yoo Sung;Paeng, Jin Chul;Kang, Keon Wook;Lee, Dong Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.72-80
    • /
    • 2015
  • Purpose Serum estradiol ($E_2$) measurement is requested for diagnosing menstrual cycles, ovulation induction, infertility, and menopause. $E_2$ is measured using several methods and kits including radioimmunoassay (RIA) and chemiluminescece immunoassay (CLIA). The purpose of this study was to evaluate quality of these methods and to compare them with each other. Materials and Methods Seven radioimmunoassay kits and two CLIA methods were included in the analysis. Using standard samples and patient samples, intra-assay precision, inter-assay precision, correlation between other methods, sensitivity, and recovery rate were evaluated. Results For all tested kits and methods, coefficients of variance (CVs) of intra-assay precision test were 10.9~13.6% in low-level samples and less than 10% in medium and high-level samples. CVs of inter-assay precision test were 10.8~12.3% in low-level samples and less than 10% in medium and high-level samples with all tested kits and methods. Recovery rates were $92.7{\pm}12.4%$ for SIEMENS, $101.4{\pm}18.4%$ for DIAsource, $95.1{\pm}11.5%$ for AMP, $108.4{\pm}18.5%$ for BECKMAN COULTER, $104.2{\pm}13.5%$ for BECKMAN COULTER Ultra Sensitive, $101.3{\pm}11.6%$ for CIS Bio, and $93.1{\pm}13.2%$ for MP kits. Sensitivity was 7.5, 6.2, 5.7, 6.2, 5.3, 4.5, and 5.5 pg/mL for SIEMENS, DIAsource, AMP, BECKMAN COULTER, BECKMAN COULTER Ultra Sensitive, CIS Bio, and MP kits, respectively. The measurement by MP kit was slightly higher than those by other kits in low-level samples, and the measurement by E170 was slightly higher than those of other kits in medium and high-level samples. In the measurement of standard sample for external quality control, SIEMENS kit produced relatively lower values whereas E170, Architect, and MP kits produced relatively higher values compared with other kits. Conclusion All tested kits for $E_2$ measurement have satisfactory performance for clinical use. However, correlation between kits should be considered when test kits are to be changed, because some pairs of kits do not have correlations with each other.

  • PDF

Investigation of Domestic and Foreign Unexpected Antibodies for Emergency Blood Transfusion (응급수혈을 위한 비예기 항체의 국내·외 실태조사)

  • Weonjoo, Hwang;Sang-Hee, Lee;Chang-Eun, Park
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.54 no.4
    • /
    • pp.279-284
    • /
    • 2022
  • Certain pre-transfusion tests are not commonly performed during emergency blood transfusion. In this study, we reviewed and analyzed the data of post-blood transfusion antibody screening tests to establish the effects of unexpected antibodies causing hemolytic transfusion reactions. We reviewed information published domestically and internationally, and selected the data of 68,602 antibody screening tests and 528 antibody identification tests conducted at P hospital. We found that unexpected antibody positive (1198,1.74%), Rh type (161, 30.49%), Lewis type (67, 12.69%), others (Di (a), 28, 5.30%). The anti-E type positive was 93 (17.61%), and that of the cases with anti-C (13, 2.46%). Only data of domestic cases were included for analysis that were published before 2007, which established the presence of antibodies of the following types and numbers of cases: anti-E (196, 22.45%), anti-Le a (82, 9.39%), and anti-E+C (60, 6.87%). In 2018, anti-E (107, 17.12%), anti-E+Canti-E+C (56, 8.96%), and anti-Di a (28, 4.48%) were detected. In other domestic cases, S hospital was detect to anti-E, anti-Le a, anti-E+C. The Anti-E, anti-D, anti-E+C, and anti-C+E were detected in D hospital. In Saudi Arabia, Anti-D, anti-E, and anti-Jka was detected. The Anti-M, Anti-N, Anti-Le (a), and Anti-D were detected in India. Requests for emergency blood transfusion increased 1.8 times after the opening of the trauma center. This study has the disadvantage of being a cross-sectional study. additional studies are needed to provide basic information on alternative treatments that can increase the safety and reduce the side effects of hemolytic transfusion in emergency transfusion situations.

A Study on the Sasang Constitutional Distribution Among the People in the United States of America (북미지역주민(北美地域住民)의 사상체질(四象體質) 분포(分布)에 관(關)한 연구(硏究))

  • Koh, Byung-hee;Kim, Seon-ho;Park, Byung-gwan;Lavelle, Jonathan D;Tecun, Marianne;Anthony Jr., Ross;Hobbs, Ron;Zolli, Frank;Chin, Kyung-hee
    • Journal of Sasang Constitutional Medicine
    • /
    • v.11 no.2
    • /
    • pp.119-150
    • /
    • 1999
  • In spite of recent remarkable recent development in both western and oriental medical sciences, there is still only a shallow understanding of individual differences for various prognoses of incurable diseases and immunopathy diseases. Nevertheless, the care, cure and prevention methods of Sasang Constitutional Medicine are broadly used as an effective treatment of incurable diseases like immunopathy diseases and stress-related diseases and diseases due to aging. In this sense, the establishment of classification norms is urgent and essential for the worldwide application of Sasang Constitutional Medicine(SCM). This study began with the confirmation process of whether Sasang Constitutional types exist in Americans. To accomodate for cultural differences, the distinguishing tool was readjusted so that Sasang Constitutional Types in Americans could be determined. Hence, the selected tool is the new QSCCII+, which is a newly revised English version of the QSCCII. QSCCII was made and standardized by Dept. of SCM in Kyung Hee Medical Center and Dr. Kim7). The evaluation methods of the old version were improved in the new QSCCII+ through necessary statistical manipulation. The original QSCCII was officially authorized by the Korean Society of Sasang Constitutional Medicine as the only computerized version of Sasang diagnostics. This study is the first attempt to design a new diagnostic tool for the classification of Sasang Constitutional types in North Americans with the revision of QSCCII. The subjects of this study were selected from the cooperative people among the students and staffs of the University of Bridgeport and the patients who visited the Clinic in the Health Science Center. This study takes for about 1 year from 1998. 8 to 1999. 8 The conclusions of the study can be summarized as follows: 1. Sasang constitutional types also exist in Americans. It can also naturally be inferred that Sasang Constitutional types exist in all human beings, for there are many different human races in America. 2. There are more So-Yang In's than any other types in American white people. This result confirms the hypothesis that there also exist Sasang Constitutional types in westerners. 3. The result of repetitive tests suggests that the new QSCCII+ is an effective diagnostic tool for westerners when we consider the constant diagnostic results of the QSCCII+. 4. Sasang Constitutional types exit in the sample group regardless of racial difference. 5. The question items that were not often checked by Americans need to be modified into more understandable expressions. 6. The standardization of diagnosis for Americans should be established by use of the QSCCII+ 7. It can be guessed that there are many Tae-yang In's among the 71 persons who could not be clearly classified by the QSCCII+. Due to the scarcity of Tae-yang-In in general, it is important to improve upon the discernability of the QSCC II+. 8. The results of the Sasang Constitutional distribution in North Americans are as follows: The percentage of So-yang In distribution in the sample group is 36.25%(87persons), that of Tae-eum In is 13.75%(33persons), and that of So-eum In is 20.41%(49persons).

  • PDF