• Title/Summary/Keyword: median body

Search Result 351, Processing Time 0.031 seconds

A Study about Scapular Rhythm of Normal Persons (정상인들의 Scapular Rhythm에 대한 연구)

  • Kim, Keun-Jo;Kim, Bonn-Won;Ahn, Duk-Hyun
    • Journal of Korean Physical Therapy Science
    • /
    • v.3 no.4
    • /
    • pp.139-145
    • /
    • 1996
  • This study was carried out to investigate the scapular rhythm of normal persons. 16 persons was no disease, injury and after-effect in period for July 1, 1996 to July 14, 1996. The statistical measures were performed by SPSS/PC t-test for classification. The result of this study were as follow : 1. There was a significant difference between the body median line and scapular superior angle from the mean distance in 83.4 mm of male and 86.0 mm of female to shoulder neutral position(p<0.05). 2. The mean distance of body median line between scapular inferior angle was 97.9 mm of male and 92.0 mm of female to shoulder neutral position. 3. There was a significant difference between the body median line and scapular inferior angle from the mean distance with male and female to shoulder abduction $90^{\circ}$ position(p<0.05). 4. The mean angle of body median line between scapular angle was $6.4^{\circ}$ of male and $4.4^{\circ}$ of female with shoulder neutral position. 5. The mean ratio of scapular rhythm was 5.6 : 1 in shoulder abduction of $90^{\circ}$ and 5.1 : 1 in shoulder abduction of 180.

  • PDF

Mean Value of Median Nerve Cross-sectional Area in Healthy 20s and 30s in Busan Area

  • Kang, Kyoung-Hwa;Lee, Gil-Hyun;Choi, Go-Eun;Hyun, Kyung-Yae
    • Biomedical Science Letters
    • /
    • v.26 no.3
    • /
    • pp.186-191
    • /
    • 2020
  • This study was designed to investigate the median nerve cross-sectional area of the upper extremity which is the main cause of CTS in the 20s and 30s. The median nerve cross-sectional area (MNC-area) of each part of the upper limb was measured in healthy 20s and 30s females and males without neurological diseases or other diseases. This MNC-area was compared with the hand, wrist, finger, and other body indexes. The research group was divided into 20s female and male groups, and the 30s were also divided into female and male groups. In the comparison between the ages, the hand, and wrist configurations in the 30s were significantly higher than those of the 20s. The mean median nerve cross-sectional area was significantly larger in the male group than in the female group in both 20s and 30s, and it was larger in both men and women than in the 20s. Hand and wrist configurations were also positively correlated with the median nerve cross-sectional area in both 20s and 30s. The median values of hand ratio and wrist ratio were 2.26 and 0.65, respectively. This median value of hand ratio was inversely correlated with the median nerve cross-sectional area. The median nerve cross-area of the 20s was 6.88~7.38 ㎟ in the male group and 5.69~6.99 ㎟ in the female group, respectively. The median nerve cross-area of the 30s was 6.32~8.89 ㎟ in the male group and 6.15~7.17 ㎟ in the female group, respectively. The mean median nerve cross-sectional area was positively correlated with body mass index in both groups. Most of the variables were higher in their 30s than in their 20s.

Low-dose Epidermal Growth Factor Receptor (EGFR)-Tyrosine Kinase Inhibition of EGFR Mutation-positive Lung Cancer: Therapeutic Benefits and Associations Between Dosage, Efficacy and Body Surface Area

  • Hirano, Ryosuke;Uchino, Junji;Ueno, Miho;Fujita, Masaki;Watanabe, Kentaro
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.2
    • /
    • pp.785-789
    • /
    • 2016
  • A key drug for treatment of EGFR mutation-positive non-small cell lung cancer is epidermal growth factor receptor-tyrosine kinase inhibitor (EGFR-TKI). While the dosage of many general anti-tumor drugs is adjusted according to the patient body surface area, one uniform dose of most TKIs is recommended regardless of body size. In many cases, dose reduction or drug cessation is necessary due to adverse effects. Disease control, however, is frequently still effective, even after dose reduction. In this study, we retrospectively reviewed the characteristics of 26 patients at Fukuoka University Hospital between January 2004 and January 2015 in whom the EGFR-TKI dose was reduced with respect to progression free survival and overall survival. There were 10 and 16 patients in the gefitinib group and the erlotinib group, respectively. The median progression-free survival in the gefitinib group and the erlotinib group was 22.4 months and 14.1 months, respectively, and the median overall survival was 30.5 months and 32.4 months, respectively. After stratification of patients by body surface area, the overall median progression-free survival was significantly more prolonged in the low body surface area (<1.45 m2) group (25.6 months) compared to the high body surface area (>1.45 m2) group (9.7 months) (p=0.0131). These results indicate that low-dose EGFR-TKI may sufficiently control disease without side effects in lung cancer patients with a small body size.

Hypofractionated stereotactic body radiotherapy in low- and intermediate-risk prostate carcinoma

  • Kim, Hun Jung;Phak, Jeong Hoon;Kim, Woo Chul
    • Radiation Oncology Journal
    • /
    • v.34 no.4
    • /
    • pp.260-264
    • /
    • 2016
  • Purpose: Stereotactic body radiotherapy (SBRT) takes advantage of low ${\alpha}/{\beta}$ ratio of prostate cancer to deliver a large dose in few fractions. We examined clinical outcomes of SBRT using CyberKnife for the treatment of low- and intermediate-risk prostate cancer. Materials and Methods: This study was based on a retrospective analysis of the 33 patients treated with SBRT using CyberKnife for localized prostate cancer (27.3% in low-risk and 72.7% in intermediate-risk). Total dose of 36.25 Gy in 5 fractions of 7.25 Gy were administered. The acute and late toxicities were recorded using the Radiation Therapy Oncology Group scale. Prostate-specific antigen (PSA) response was monitored. Results: Thirty-three patients with a median 51 months (range, 6 to 71 months) follow-up were analyzed. There was no biochemical failure. Median PSA nadir was 0.27 ng/mL at median 33 months and PSA bounce occurred in 30.3% (n = 10) of patients at median at median 10.5 months after SBRT. No grade 3 acute toxicity was noted. The 18.2% of the patients had acute grade 2 genitourinary (GU) toxicities and 21.2% had acute grade 2 gastrointestinal (GI) toxicities. After follow-up of 2 months, most complications had returned to baseline. There was no grade 3 late GU and GI toxicity. Conclusion: Our experience with SBRT using CyberKnife in low- and intermediate-risk prostate cancer demonstrates favorable efficacy and toxicity. Further studies with more patients and longer follow-up duration are required.

Fine Structural Analysis of Principal and Secondary Eyes in Wandering Spider, Pardosa astrigera (배회성 거미 (Pardosa astrigera) 주안과 부안의 미세구조적 분석)

  • Jeong, Moon-Jin;Lim, Do-Seon;Moon, Myung-Jin
    • Applied Microscopy
    • /
    • v.30 no.1
    • /
    • pp.1-9
    • /
    • 2000
  • The wandering spider, Pardosa astrigera, had four pairs of ocelli that arranged in three rows on the cephalothorax. Along the anterior margin lay a pair of small anterior median (AM) eye flanked on each side by anterior lateral (AL) eye. Two large posterior median (PM) eye was situated on the clypeus behind the anterior row and still more posteriorly was a pair of posterior lateral (PL) eye. The visual cell of retina consisted of cell body, rhabdome, and intermediate segment. Bipolar neuron was found in anterior median eye (principal eye) and unipolar neuron in others (secondary eye). Rhabdome showed that arranged in PMeye and PLeye. But rhabdomes of AMeye and ALeye were irregular in retina. Except AMeye, incontinuous tapetum found in ALeye, PMeye, PLeye. Anterior median eye was similar to anterior lateral eye in length and posterior median eye similar to posterior lateral eye. Component size of eye were similar to 4 pairs eye in cornea. Size of lens, cell body, and rhabdome was similar not only anterior median eye and anterior lateral eye but also posterior median eye and posterior lateral eye. Vitreous body was large posterior median eye than others.

  • PDF

Feasibility Analysis on Wind Turbine Embedded to Highway Median Strip - Consideration on Vehicle Drag Coefficient (고속도로 중앙분리대형 풍력발전 타당성 분석 - 차량 저항계수 관점에서)

  • Yoon, Seong-Wook;Jeon, Wan-Ho;Kim, Hyun-Goo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.536-538
    • /
    • 2009
  • In recent day, many people are interested in wind resource for generation of electric power. Especially, it is made assessment the possibility of generation of electric power by wind resource originated from running cars and buses in downtown or highway. Moreover bus, driven in the exclusive lane, is focused on possibility of generation electric power on highway because median strip makes fast flow way between bus body and median strip and a pattern will appear in the flow way like drag coefficient. But nobody can guess whether the induced flow will increase or decrease and estimate amount of change of drag coefficient. Solving drag coefficient of bus running highway is the point of this paper. To solve this problem, we use the CFD method. The model is a bus simplified without mirror and gates. In order to assess result, the flow analysis surrounding the bus on the flat road where median strip is not installed has been compared with road with median strip. Solving condition is that the driving highway and median strip are running with 100km/h (27.8m/s).

  • PDF

Significantly Low Effective Dose from 18FDG PET/CT Scans Using Dose Reducing Strategies: "Lesser is Better"

  • uz Zaman, Maseeh;Fatima, Nosheen;Zaman, Areeba;Zaman, Unaiza;Tahseen, Rabia
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.7
    • /
    • pp.3465-3468
    • /
    • 2016
  • Background: Fluorodeoxyglucose ($^{18}FDG$) PET/CT imaging has become an important component of the management paradigm in oncology. However, the significant imparted radiation exposure is a matter of growing concern especially in younger populations who have better odds of survival. The aim of this study was to estimate the effective dose received by patients having whole body $^{18}F$-FDG PET/CT scanning as per recent dose reducing guidelines at a tertiary care hospital. Materials and Methods: This prospective study covered 63 patients with different cancers who were referred for PET/CT study for various indications. Patients were prepared as per departmental protocol and 18FDG was injected at 3 MBq/Kg and a low dose, non-enhanced CT protocol (LD-NECT) was used. Diagnostic CT studies of specific regions were subsequently performed if required. Effective dose imparted by 18FDG (internal exposure) was calculated by using multiplying injected dose in MBq with coefficient $1.9{\times}10^{-2}mSv/MBq$ according to ICRP publication 106. Effective dose imparted by CT was calculated by multiplying DLP (mGy.cm) with ICRP conversion coefficient "k" 0.015 [mSv / (mG. cm)]. Results: Mean age of patients was $49{\pm}18$ years with a male to female ratio of 35:28 (56%:44%). Median dose of 18FDG given was 194 MBq (range: 139-293). Median CTDIvol was 3.25 (2.4-6.2) and median DLP was 334.95 (246.70 - 576.70). Estimated median effective dose imparted by $^{18}FDG$ was 3.69 mSv (range: 2.85-5.57). Similarly the estimated median effective dose by low dose (non-diagnostic) CT examination was 4.93 mSv (range: 2.14 -10.49). Median total effective dose by whole body 18FDG PET plus low dose non-diagnostic CT study was 8.85 mSv (range: 5.56-13.00). Conclusions: We conclude that the median effective dose from a whole body 18FDG PET/CT in our patients was significantly low. We suggest adhering to recently published dose reducing strategies, use of ToF scanner with CT dose reducing option to achieve the lower if not the lowest effective dose. This would certainly reduce the risk of second primary malignancy in younger patients with higher odds of cure from first primary cancer.

Comparative Assessment of the Vertebral Left Atrial Size in Healthy Adult Dogs

  • Han, Sung-Hyun;Yun, Mun-Su;Song, Kunho
    • Journal of Veterinary Clinics
    • /
    • v.39 no.2
    • /
    • pp.45-50
    • /
    • 2022
  • Vertebral left atrial size can be used as a radiographic tool to evaluate left atrial size in dogs. Vertebral left atrial size has been studied in dogs; however, few studies have been conducted on breed-specific differences in healthy dogs. To study the median vertebral left atrial size differences by breed and to investigate the association between age, sex, body condition score, thoracic depth-to-width ratio, and vertebral left atrial size. A total of 220 dogs of the following breeds: Maltese (n = 73), Beagle (n = 30), Poodle (n = 41), Shih-tzu (n = 44), and Mongrel (n = 32) were reviewed retrospectively. Sex, body weight, age, and body condition score of each dog were collected. Thoracic radiography was conducted for dorsoventral and right/left lateral views in all dogs to measure the vertebral heart score, vertebral left atrial size, and thoracic depth-to-width ratio. No significant differences in the median vertebral left atrial size were found among the breeds. There were no effects of sex, age, body condition score, and thoracic depth-to-width ratio on vertebral left atrial size. There was a significant positive correlation between the vertebral heart score and vertebral left atrial size. Breed, age, sex, and chest conformation did not correlate with vertebral left atrial size.

Effects of Consecutive whole Body Vibration Exercise using Heel Raise Posture on Neuromuscular Response during Single-leg Stance (뒤꿈치 들기 자세를 이용한 전신진동 운동이 외발서기 시 근신경 반응에 미치는 영향)

  • Kim, Dae Dong;Lee, Myeounggon;Youm, Changhong
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.2
    • /
    • pp.104-112
    • /
    • 2021
  • Objective: This study aimed to analyze the effects of consecutive whole body vibration through heel raise posture on the center of pressure and electromyography of anterior tibial muscle, lateral gastrocnemius and soleus muscles during single-leg stance. Method: The subjects of this study included 30 healthy males in their 20's, with the following inclusion criteria: no history of orthopaedic medical history, no participation in regular exercises, no history of whole body vibration exercise, and right leg being the dominant leg. The experimental procedure involved pretreatment measurement of eye open single-leg stance, application of whole body vibration for 30 seconds, post-treatment measurement (3 measurements in total). Static and dynamic movements have been measured over 2 separate experiments, with 72 hours gap between the experiments. Static movement involved maintaining single-leg heel raise posture for 30 seconds while applying whole body vibration, and dynamic movement involved heel raise (15 repetitions over 30 seconds) while applying whole body vibration. The strength of applied whole body vibration was 35 Hz frequency and 2~4 mm amplitude. Results: As the single-leg posture after static heel raise posture, mediolateral velocity of the center of pressure at post 2 and post 3 were significantly reduced compared to the pre-treatment measurement. In addition, the percentage for reference voluntary contraction in anterior tibial muscle and soleus and median frequency at anterior tibial muscle and lateral gastrocnemius muscle at post 3 were significantly decreased compared to the pre-treatment value. As the single-leg posture after dynamic heel raise posture, the mediolateral 95% edge frequency of the center of pressure and median frequency at anterior tibial muscle, lateral gastrocnemius muscle, and soleus muscle at post 3 were significantly reduced compared to the pre-treatment value. Conclusion: Acute whole body vibration via static and dynamic heel raise posture have positive effect on mediolateral posture control during single-leg stance.

Median modified wiener filter for improving the image quality of gamma camera images

  • Park, Chan Rok;Kang, Seong-Hyeon;Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • v.52 no.10
    • /
    • pp.2328-2333
    • /
    • 2020
  • The filter technique was applied to noise images, as noise is the significant factor that cause poor image quality due to lower photon counting. The purpose of this study is to confirm that image quality can be improved using the median modified Wiener filter (MMWF) technique; this is achieved via a National Electrical Manufacturers Association International Electrotechnical Commission body phantom with four large spheres that are filled with the 99mTc radioisotope when evaluating the image quality. Conventional filters such as Wiener, Gaussian, and median filters were designed, and signal to noise ratio, coefficient of variation, and contrast to noise ratio were used as the evaluation parameters. The improvement in the image quality was in the following order, from the least to the highest improvement, in all cases: Wiener filter, Gaussian filter, median filter, and the MMWF technique. The results show that the image quality was improved from 20.6 to 65.5%, 7.4-40.3%, and 12.7-44.7% for the SNR, COV, and CNR values, respectively, when using the MMWF technique, compared with the use of conventional filters. In conclusion, our results demonstrated that the MMWF technique is useful for reducing the noise distribution in gamma camera images.