• Title/Summary/Keyword: medial approach

Search Result 115, Processing Time 0.045 seconds

Sonoanatomic Variation of Pes Anserine Bursa

  • Imani, Farnad;Rahimzadeh, Poupak;Gharehdag, Farid Abolhasan;Faiz, Seyed Hamid Reza
    • The Korean Journal of Pain
    • /
    • v.26 no.3
    • /
    • pp.249-254
    • /
    • 2013
  • Background: The pes anserine bursa lies beneath the pes anserine tendon, which is the insertional tendon of the sartorius, gracilis, and semitendinosus muscles on the medial side of the tibia, but it can lie in different sites in the medial knee. Accurate diagnosis of the position of the bursa is critical for diagnostic and therapeutic goals. The aim of this study was to evaluate sonoanatomic variations of the pes anserine bursa in the medial knee. Methods: One hundred seventy asymptomatic volunteers were enrolled in this study. Using ultrasound imaging (transverse approach, 7-13 MHz linear array probe) the sonoanatomic position of the pes anserine bursa and its relation to the pes anserine tendon were evaluated. Additionally, we evaluated the sonoanatomic variation of the saphenous nerve. Results: The position of the pes anserine bursa was between the medial collateral ligament and the pes anserine tendons in 21.2%/18.8% (males/females) of subjects; between the pes anserine tendons and the tibia in 67.1%/64.7% (m/f); and among the pes anserine tendons in 8.2%/12.9% (m/f). No significant differences in the position of the bursa existed between males and females. The saphenous nerve was found within the pes anserine tendons in 77.6%/74.1% (m/f) of subjects, but outside the pes anserine tendons in 18.8%/15.3% (m/f). Visibility of sonoanatomic structures was not related to either gender or BMI. Conclusions: Ultrasound provides very accurate information about variations in the pes anserine bursa and the saphenous nerve. This suggests that our proposed ultrasound method can be a reliable guide to facilitate approaches to the medial knee for diagnostic and therapeutic objectives.

A novel technique for placing titanium mesh with porous polyethylene via the endoscopic transnasal approach into the orbit for medial orbital wall fractures

  • Bae, Seong Hwan;Jeong, Dae Kyun;Go, Ju Young;Park, Heeseung;Kim, Joo Hyoung;Lee, Jae Woo;Kang, Taewoo
    • Archives of Plastic Surgery
    • /
    • v.46 no.5
    • /
    • pp.421-425
    • /
    • 2019
  • Background The endoscopic transnasal approach is widely used for reconstructing the medial orbital wall by filling it with a silicone sheet or Merocel, but this technique has the disadvantage of retaining the packing for a long time. To overcome this drawback, a method of positioning an absorbable plate in the orbit has been introduced, but there is a risk of defect recurrence after the plate is absorbed. Here, the authors report the results of a novel surgical technique of placing a nonabsorbable titanium mesh with porous polyethylene into the orbit through the endoscopic transnasal approach. Methods Fourteen patients underwent surgery using the endoscopic transnasal approach. Preoperative computed tomography (CT) was used to calculate the size of the bone defect due to the fracture, and the titanium mesh was designed to be shorter than the anteroposterior length of the defect and longer than its height. The titanium mesh was inserted into the orbit under an endoscopic view. The authors then confirmed that the titanium mesh supported the orbital contents by pressing the eyeball and finished the operation. Immediately after surgery, CT results were evaluated. Results Postoperative CT scans confirmed that the titanium mesh was well-inserted and in the correct position. All patients were discharged without any complications. Conclusions We obtained satisfactory results by inserting a titanium mesh with porous polyethylene into the orbit via the transnasal approach endoscopically.

Technical Note Transarticular Approach for Elbow Arthroscopy

  • Kim Sung-Jae;Jeong Jae-Hoon
    • The Academic Congress of Korean Shoulder and Elbow Society
    • /
    • 2004.11a
    • /
    • pp.176-179
    • /
    • 2004
  • Arthroscopy of the stiff elbow joint is a technically difficult procedure because of the decreased joint space of the elbow joint. even to experienced surgeons. Problems encountered include limited access of instrument to the intra-articular ,pace and an increased risk of cartilage injury in the contracted elbow joint. This study describes a novel transarticular approach for elbow arthroscopy that allow, the safe and effective creation of the proximal medial and lateral portals.

  • PDF

Medial Canthopexy using Modified Hiraga's Incision for Correction of Traumatic Telecanthus (외상성 내안각격리증 환자에 있어 Hiraga 절개법을 이용한 내안각 고정술)

  • Lim, Jong-Hyo;Kim, Yong-Ha;Kim, Tae-Gon;Lee, Jun-Ho
    • Archives of Plastic Surgery
    • /
    • v.37 no.4
    • /
    • pp.504-508
    • /
    • 2010
  • Purpose: Traumatic telecanthus can result from nasoethmoid-orbital fractures. Repair of the medial canthal tendon (MCT) using transnasal wiring is regarded as a choice of method to treat telecanthus, however, is often complicated by incomplete anchoring and drift of canthus, extrusion of wire, in-fracture of orbital bone, and eye damage. The authors introduced oblique transnasal wiring method through the Hiraga's epicanthopalsty incision instead of well-known classical bicoronal approach. Methods: Five patients with traumatic telecanthus were treated with this method. Though the Hiraga's epicanthoplasty incision, we could approach the operative field; the medial orbital wall and detached MCT. Oblique transnasal wiring was performed as following steps. After slit skin incision on the contralateral nasal recession area, drill holes were made from this point to the superior and posterior point of lacrimal sac of deformed eye. A 2-0 wire was double-passed through the holes and MCT. Traction was applied to ensure pulling the MCT and the wires were twisted in the contralateral nose, securing the MCT in the correct position. Results: All patients except 1 person showed improvement and rapid recovery. On average each canthus was moved 5.6 mm medially. In all cases, there were no eyelashes disappear, lacrimal canaliculitis, lacrimal duct injury, or infections. Conclusion: The Hiraga's epicanthoplasty incision could give sufficient operative field to reattach the MCT in traumatic telecanthus patients. And the oblique transnasal wiring technique is effective for the Asians who have flat nose and exophthalmic eye. The authors conclude that this technique could be a simple, safe and scarless method to correct traumatic telecanthus.

Traumatic Displacement of the Globe into the Maxillary Sinus: Case Report (외상성 상악동 안구탈출의 치험례: 증례보고)

  • Lim, Chan Soo;Kang, Dong Hee
    • Archives of Plastic Surgery
    • /
    • v.34 no.4
    • /
    • pp.524-527
    • /
    • 2007
  • Purpose: Globe displacement due to a blowout fracture is a rare clinical phenomenon. The authors present reduction of a globe displacement to the maxillary sinus due to trauma suffered in a fall and the reconstruction of a large defect left in the medial and inferior orbit. Methods: A 39-year-old male patient was unable to open his left eye after being struck on the periorbital area by a metal edge. Laceration was not noted in that area but we were unable to observe the intraorbital globe. A facial computed tomography (CT) scan showed that the globe was displaced through the maxillary sinus. A transconjunctival approach was used to access the infraorbital margin and the globe entrapped in the inferior margin of the orbit was successfully reduced. A large defect in the medial and inferior orbit was reconstructed using a graft from the iliac bone. Results: In 5 months after the operation, no atrophy of the globe was seen. Both sides retained a similar shape. A satisfactory functionality outcome in terms of improved extraocular muscle movement, and a satisfactory aesthetical outcome were achieved. Conclusion: The authors report the reduction of a globe displaced to the maxillary sinus following a fall and the reconstruction of the large defect left in the medial and inferior orbit.

Pronunciation of Sonorant Clusters in English for Korean Speakers: A Constraint-based Approach

  • Chung, Chin-Wan
    • English Language & Literature Teaching
    • /
    • v.13 no.3
    • /
    • pp.23-40
    • /
    • 2007
  • This paper discusses why Korean speakers have problems in pronouncing some medial sonorant clusters in English. We argue that the main reasons lie in the sonority sequence requirement difference between the two languages. English does not have any specific sonority sequence preference between the medial sonorant sequences while Korean has a strict requirement between the two sonorants over a syllable boundary. This sonority sequence requirement difference between the two languages acts as an interference for Korean speakers in learning English pronunciation. This barrier for Korean speakers in acquiring correct pronunciation is implemented in a constraint ranking difference in the Optimality Theory, which is not familiar for Korean speakers. Understanding the details of sonorant production mechanisms along with the different constraint ranking will facilitate the learning process of Korean speakers learning English.

  • PDF

Burn Wound along the Guide Needle Trajectory as a Complication of Radiofrequency Neurotomy of the Lumbar Medial Branch -A case report- (요부 내측지 고주파 신경절리술 시행 시 유도침 경로를 따라 발생한 화상 -증례보고-)

  • Youn, Hong Jun;Shim, Jae Chol
    • The Korean Journal of Pain
    • /
    • v.19 no.2
    • /
    • pp.257-260
    • /
    • 2006
  • Radiofrequency neurotomy of the lumbar medial branch, via a caudal approach, is a representative interventional procedure for lumbar zygapophysial joint pain, which can be performed more accurately and easily using a guide needle technique. We experienced a case of burn wound formation along the guide needle trajectory, where heat conduction through the guide needle was suggested to have resulted in the burn wound.

A New Anterior Approach for Fluoroscopy-guided Suprascapular Nerve Block - A Preliminary Report -

  • Kang, Sang-Soo;Jung, Jae-Woo;Song, Chang-Keun;Yoon, Young-Jun;Shin, Keun-Man
    • The Korean Journal of Pain
    • /
    • v.25 no.3
    • /
    • pp.168-172
    • /
    • 2012
  • Background: The aim of the study was to investigate the feasibility of fluoroscopy-guided anterior approach for suprascapular nerve block (SSNB). Methods: Twenty patients with chronic shoulder pain were included in the study. All of the nerve blocks were performed with patients in a supine position. Fluoroscopy was tilted medially to obtain the best view of the scapular notch (medial angle) and caudally to put the base of coracoid process and scapular spine on same line (caudal angle). SSNB was performed by introducing a 100-mm, 21-gauge needle to the scapular notch with tunnel view technique. Following negative aspiration, 1.0 ml of contrast was injected to confirm the scapular notch, and 1 % mepivacaine 2 ml was slowly injected. The success of SSNB was assessed by numerical rating scale (NRS) before and after the block. Results: The average NRS was decreased from $4.8{\pm}0.6$ to $0.6{\pm}0.5$ after the procedure (P < 0.05). The best view of the scapular notch was obtained in a medial angle of $15.1{\pm}2.2$ ($11-19^{\circ}$) and a caudal angle of $15.4{\pm}1.7^{\circ}$ ($12-18^{\circ}$). The average distance from the skin to the scapular notch was $5.8{\pm}0.6$ cm. None of the complications such as pneumothorax, intravascular injection, and hematoma formation was found except one case of partial brachial plexus block. Conclusions: SSNB by fluoroscopy-guided anterior approach is a feasible technique. The advantage of using a fluoroscopy resulted in an effective block with a small dose of local anesthetics by an accurate placement of a tip of needle in the scapular notch while avoiding pneumothorax.

Morphological Assessment of Cadaveric Radial, Brachial and Subclavian Arteries : A Neurointerventional Approach

  • Yilmaz, Ali;Ozkul, Ayca;Shin, Dong Seong;Im, Soo-Bin;Yoon, Seok-Mann;Kim, Bum-Tae
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.6
    • /
    • pp.499-503
    • /
    • 2015
  • Objective : The transradial catheterization (TRC) is becoming widespread, primarily for neurointerventions. Therefore, the evaluation of radial artery puncture in clinical practice and a better understanding of the anatomy are important to improve the safety of neuroendovascular surgery. Methods : Ten formalin-fixed adult Korean cadavers were dissected to expose radial artery (RA), brachial artery (BrA) and subclvian artery (ScA), bilaterally. Vessel lengths and diameters were meaured using a caliper and distance between the specific point of vessels and the anatomical landmarks including the radial styloid process, the medial epicondyle of the humerus, the sternoclavicular joint, and the vertebral artery orifice were also measured. Results : The average length between the radial (RAPS) and the BrA puncture sites (BrAPS) and between the vertebral artery orifice (VAO) and the BrA bifurcation (BrAB) did not differ between sides (p>0.05). The average length between the radial styloid process (RSP) and the RAPS was $13.41{\pm}2.19mm$, and the RSP was $26.85{\pm}2.47mm$ from the median nerve (MN). The mean length between the medial epicondyle (ME) and the BrAPS as $44.23{\pm}5.47mm$, whereas the distance between the ME and the MN was $42.23{\pm}4.77mm$. The average VAO-ScA angle was $70.94{\pm}6.12^{\circ}$, and the length between the ScA junction (SCJ) and the VAO was $60.30{\pm}8.48mm$. Conclusion : This study provides basic anatomical information about the radial artery and the brachial route and can help improving new techniques, selection of size and shape of catheters for TRC. This can help neurointerventionists who adopt a transradial neuroendovascular approach and offers comprehensive and safe care to their patients.

The Open Surgical Treatment for Stiff Elbow (주관절 구축의 관혈적 치료)

  • Lee, Ji-Ho;Ra, In-Hoo;Jeon, In-Ho
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.2
    • /
    • pp.293-298
    • /
    • 2010
  • Purpose: Since an injured elbow joint can disturb the activity of daily life by limiting motion, especially if the motion is restricted over 40 degree of flexion contracture and under 105 degree of further flexion, it is imperative to select the best method and the timing of treatment of the elbow stiffness. Therefore this review will discuss open surgical techniques for stiff elbows based on the literature. Materials and Methods: It is important to take sufficient clinical examination of the patient, including history taking. And, a surgeon should select appropriate procedure after accurately understanding about the status and cause of the stiff elbow with radiographic methods. Surgical methods include arthroscopic release open release, distraction arthroplasty, total elbow replacement and there are four approachs in the open release - anterior approach, medial "over the top" approach, limited lateral approach: column procedure, posterior extensile approach-. Results and Conclusion: Although at present the arthroscopic technique is emphasized for the treatment of elbow stiffness, a surgeon should know conventional open techniques.