• Title/Summary/Keyword: mechanical strain device

Search Result 99, Processing Time 0.022 seconds

Development of Optical Strain Sensor with Nanostructures on a Poly-dimethylsiloxane (PDMS) Substrate (Poly-dimethylsiloxane (PDMS) 기판 위에 형성된 나노구조를 이용한 시각 인장센서의 개발)

  • Kim, Geon Hwee;Woo, Hyeonsu;Lim, Geunbae;An, Taechang
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.6
    • /
    • pp.392-396
    • /
    • 2018
  • Structural color has many advantages over pigment based color. In recent years, researches are being conducted to apply these advantages to applications such as wearable devices. In this study, strain sensor, a kind of wearable device, was developed using structural color. The use of structural color has the advantage of not using energy and complex measuring equipment to measure strain rate. Wrinkle structure was fabricated on the surface of Poly-dimethylsiloxane (PDMS) and used it as a sensor which color changes according to the applied strain. In addition, a transmittance-changing sensor was developed and fabricated by synthesizing additional glass nanoparticles. Furthermore, a strain sensor was developed that is largely transparent at the target strain and opaque otherwise.

Dynamic Behavior Characteristic Test of Structural Aluminium Alloy Materials using SHPB (SHPB를 이용한 구조용 AL합금재의 동적거동 특성 시험에 관한 연구)

  • Hur, S.;Kim, D.S.;Koo, J.S.;Kang, H.S.;Hong, S.I.;Chung, D.T.
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.419-423
    • /
    • 2001
  • It is important to know the mechanical properties of the materials under dynamic load. The mechanical properties of most materials are influenced to some extent by strain rate. One of the reliable test device for determining the mechanical properties of materials at high strain rate is Split Hopkinson Pressure bar. In this paper, we conducted the mechanical properties test for the aluminium alloy 6063 and 6061 using the SHPB device.

  • PDF

Development of Data Acquisition System for Strain Gauge Sensor (스트레인게이지 센서용 데이터획득시스템의 개발)

  • Cho, Si-Hyeong;Park, Chan-Won
    • Journal of Industrial Technology
    • /
    • v.30 no.A
    • /
    • pp.89-93
    • /
    • 2010
  • This research suggested a development of a Data Acquisition System for strain gauge sensor which enables the usage of portable device in the various engineering field that includes, a strain indicator which is frequently used in civil and mechanical engineering, and a GUI function of data acquisition device. The developed system can record 16 channels of strain gauges at a time and its resolution is over 16 bits which can be used effectively in the actual field.

  • PDF

A Newly-developed Plane Strain Testing Device and Its Applicability (새로운 평면변형률 시험장비의 개발과 적용성 검증)

  • Kim Chang-Youb;Lee Young-Sun;Chung Choong-Ki
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.1
    • /
    • pp.5-14
    • /
    • 2006
  • A simple and useful plane strain testing device was newly developed and its mechanical features were presented in this paper. The new testing device was designed to be capable of testing various stress paths expected under plane strain condition with only the conventional triaxial loading system. The applicability of the new testing device was systematically checked both by theoretical evaluation and by experiments. As a result, it was found that the new testing device has much wider range of application than the conventional plane strain testing devices.

Design of Load and Strain Measuring Equipment Using Strain Gage, Instrumental Differential Amplifier and A/D Converter in a Truss System (스트레인 게이지 계측용 차동 증폭기와 A/D 변환기를 이용한 트러스 구조물의 내력 측정 장치 설계)

  • Baek, Tae-Hyun;Lee, Byung-Hee
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.2
    • /
    • pp.217-224
    • /
    • 2008
  • Trusses are found in many common structures such as bridges and buildings. The truss is a fundamental design element in engineering structures and it is important for an engineer to apply the truss design to engineering structures by understanding the mechanics of truss element. In an experimental course, the experiment selves as an example of the usefulness of the Wheatstone bridge in amplifying the output of a transducer. With the apparatus described here, it is possible to obtain experimental measurements of forces in a truss member which agree within errors to predictions from elementary mechanics. The apparatus is inexpensive, easy to operate, and suitable as either a classroom demonstration or student laboratory experiment. This device is a small table-top experiment. The conventional strain measuring device is costly and complicated - it is not simple to understand its structure. Hence, strain gage and the A/D converter are assembled to come up with a load and a strain measuring device. The device was tested for measuring the strain in a loaded specimen and the results were compared to those predicted by theory of mechanics.

Strain measurement method for moving parts using IoT sensors (사물인터넷 센서를 이용한 동적 부품의 스트레인 측정 방법)

  • Ba Da Kim;Young Chul An;Jung Hyun Park;Yeong Jun Yu;Chul Hee Lee;Daeyup Lee
    • Journal of Drive and Control
    • /
    • v.20 no.1
    • /
    • pp.41-47
    • /
    • 2023
  • The aim of this study was to develop a method for installing strain gauges on moving, lubricating oil-filled, and sealed parts, such as drive shafts of equipment, including construction machinery. A measuring device was constructed using an embedded CPU and an IoT sensor to measure the strain of the strain gauge, which allowed for the measurement of axial torque and axial force, and subsequent analysis. To verify the performance of the developed device, the axial torque and axial force of the forklift were measured during operation using a strain gauge attached to the inside of the drive shaft. This study confirmed the possibility of measuring and analyzing the strain of a moving part, such as the inside of a drive shaft, which is sealed and filled with hydraulic oil.

Influences of Bending Temperature on the I$_{c}$ Degradation Behavior of Bi-2223 tapes under Bending

  • Shin Hyung Seop;Dizon John Ryan C.;Katagiri Kazumune;Kuroda Tsuneo
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.2
    • /
    • pp.11-15
    • /
    • 2005
  • The I$_{c}$ degradation behavior of Bi-2223 tapes bent at RT and 77K were investigated using the bending device invented by Goldacker. Test results on fixing the tape at RT and 17K showed no difference. At 17K and RT bending, the critical strain was 0.67 and 0.50$\%$, respectively, for the VAM-l tape. For the AMSC tape, it was 0.94 and 0.88$\%$, respectively. These results show that there is additional residual stress in the superconducting filaments to be bent at 17K which shifts the formation of cracks into smaller bending radii. This was proved by computational analysis based on the mixture rule of composites. For the VAM-l tape, the Ie degradation behavior using the Goldacker type device shifted to higher strain levels at about 0.5$\%$, as compared with the FRP sample holders which have a critical bending strain of about 0.24$\%$. Also, for the externally reinforced AMSC tape, Ie degradation using the Goldacker type device begins at a higher strain level, at 0.88$\%$ as compared with using FRP sample holders, at 0.74$\%$. The difference between both cases can be explained by the tensile' and thermal stresses that the tapes were subjected to during fixing (soldering) when the FRP sample holders were used.

Wavelength tunability of a fiber ring laser using a novel strain device (새로운 스트레인 인가장치를 이용한 광섬유 링 레이저의 파장가변 특성)

  • Kim, Sung-Chun;Jang, Hyun-Soo;Lee, Kyung-Shik
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.1
    • /
    • pp.99-102
    • /
    • 2005
  • We fabricated a tunable fiber ring laser consisting of a novel strain device and fiber Bragg gratings. The lasing power and FWHM bandwidth of the optical fiber ring laser was -12dBm and 0.05nm respectively. The fiber ring laser was tuned as much as 10nm at a 8000.

Ag Electrode Strain Sensor Fabrication Using Laser Direct Writing Process

  • Kim, Hyeonseok;Shin, Jaeho;Hong, Sukjoon;Ko, Seung Hwan
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.4
    • /
    • pp.215-218
    • /
    • 2015
  • As several innovative technologies for flexible electric devices are being realized, demand for in-situ strain monitoring for flexible electric devices is being emphasized. Because flexible devices are commonly influenced by substrate strain, suitable strain sensors for flexible devices are essential for the sophisticated maneuvering of flexible devices. In this study, a flexible strain sensor based on an Ag electrode is prepared on a polyimide substrate using the LDW (laser direct writing) process. In this process, first, the Ag nanoparticles are coated on the substrate and selectively sintered using a focused laser. Because of the advantages of the LDW process (such as being mask-less, using low temperatures, and having non-vacuum characteristics), the entire fabrication process has been dramatically simplified; as a final outcome, a highly reliable strain sensor has been fabricated. Using this strain sensor, various strain conditions that arise from different bending radii can be detected by measuring real-time electrical signals.

Study of dynamic mechanical behavior of aluminum 7075-T6 with respect to diameters and L/D ratios using Split Hopkinson Pressure Bar (SHPB)

  • Kim, Eunhye;Changani, Hossein
    • Structural Engineering and Mechanics
    • /
    • v.55 no.4
    • /
    • pp.857-869
    • /
    • 2015
  • The aluminum 7075-T6 is known as an alloy widely used in aircraft structural applications, which does not exhibit strain rate sensitivity during dynamic compressive tests. Despite mechanical importance of the material, there is not enough attention to determine appropriate sample dimensions such as a sample diameter relative to the device bar diameter and sample length to diameter (L/D) ratio for dynamic tests and how these two parameters can change mechanical behaviors of the sample under dynamic loading condition. In this study, various samples which have different diameters of 31.8, 25.4, 15.9, and 9.5 mm and sample L/D ratios of 2.0, 1.5, 1.0, 0.5, and 0.25 were tested using Split Hopkinson Pressure Bar (SHPB), as this testing device is proper to characterize mechanical behaviors of solid materials at high strain rates. The mechanical behavior of this alloy was examined under ${\sim}200-5,500s^{-1}$ dynamic strain rate. Aluminum samples of 2.0, 1.5 and 1.0 of L/D ratios were well fitted into the stress-strain curve, Madison and Green's diagram, regardless of the sample diameters. Also, the 0.5 and 0.25 L/D ratio samples having the diameter of 31.8 and 25.4 mm followed the stress-strain curve. As results, larger samples (31.8 and 25.4 mm) in diameters followed the stress-strain curve regardless of the L/D ratios, whereas the 0.5 and 0.25 L/D ratios of small diameter sample (15.9 and 9.5 mm) did not follow the stress-strain diagram but significantly deviate from the diagram. Our results indicate that the L/D ratio is important determinant in stress-strain responses under the SHPB test when the sample diameter is small relative to the test bar diameter (31.8 mm), but when sample diameter is close to the bar diameter, L/D ratio does not significantly affect the stress-strain responses. This suggests that the areal mismatch (non-contact area of the testing bar) between the sample and the bar can misrepresent mechanical behaviors of the aluminum 7075-T6 at the dynamic loading condition.