New Approach in the Treatment of Intertrochanteric Fracture Using a Cephalomedullary Nail (골수정을 이용한 대퇴골 전자간 골절의 새로운 치료 경향)

  • Kim, Junyoung;Choi, Kihong;Yang, Kyu Hyun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.3
    • /
    • pp.193-199
    • /
    • 2020
  • A gamma nail has been used to treat intertrochanteric fractures since 1988. Although such cephalomedullary nails have mechanical advantages over extramedullary fixation devices, such as sliding hip screw, their beneficial effects on treating the Arbeitsgemeinschaft für Osteosynthesefragen/Orthopaedic Trauma Association (AO/OTA) 31-A1 and 31-A2 fractures are still controversial. During their 30-year history, many problems have been overcome, and new types of cephalomedullary nails have been introduced in clinical practice. New cephalomedullary nail systems facilitate nailing procedures and enhance the purchase capability of the femoral head by a lag screw. On the other hand, the failure rate still depends on the hands of the orthopedic surgeons. This review article focused on the basic principle of medial support and restoration of a medial buttress during the treatment of trochanteric fractures using a cephalomedullary nail.

Improvement of Dimensional Stability of Tropical Light-Wood Ceiba pentandra (L) by Combined Alkali Treatment and Densification

  • Deded Sarip NAWAWI;Andita MARIA;Rizal Danang FIRDAUS;Istie Sekartining RAHAYU;Adesna FATRAWANA;Fadlan PRAMATANA;Pamona Silvia SINAGA;Widya FATRIASARI
    • Journal of the Korean Wood Science and Technology
    • /
    • v.51 no.2
    • /
    • pp.133-144
    • /
    • 2023
  • Densification is an effective method for improving the physical and mechanical properties of low-density wood. However, the set-recovery of dimensions was found to be the problem of densified wood due to low fixation during the densification process. Alkali pretreatment before densification is thought to be a modification process to improve the dimensional stability of densified wood. In this research, the wood samples used were boiled in a 1.25 N sodium hydroxide (NaOH) solution at different times, followed by densification for 5 h at 100℃. The alkali pretreatment for 1, 3, and 5 h of boiling increased the dimensional stability of densified woods and anti-swelling efficiency values were 8.52%, 63.24%, and 48.94%, respectively. The boiling of wood in NaOH solution decreased the holocellulose content, as well as lignin to a lesser degree, and a lower crystallinity index was observed. The lower hydroxyl groups and a higher proportion of lignin in treated samples seem to have contributed to the high dimensional stability detected.

Development of Porcine Pericardial Heterograft for Clinical Application (Tensile Strength-thickness) (돼지의 심낭을 이용한 이종이식 보철편의 개발 (장력-두께간의 구조적 특성))

  • Kim, Kwan-Chang;Lee, Cheul;Choi, Chang-Hue;Lee, Chang-Ha;Oh, Sam-Sae;Park, Seong-Sik;Kim, Kyung-Hwan;Kim, Woong-Han;Kim, Yong-Jin
    • Journal of Chest Surgery
    • /
    • v.41 no.2
    • /
    • pp.170-176
    • /
    • 2008
  • Background: Bioprosthetic devices for treating cardiovascular diseases and defects may provide alternatives to autologous and homograft tissue. We evaluated the mechanical and physical conditions of a porcine pericardial bioprosthesis treated with Glutaraldehyde (GA), Ethanol, or Sodium dodecylsulfate (SDS) before implantation. Material and Method: 1) Thirty square-shaped pieces of porcine pericardium were fixed in 0.625%, 1.5% or 3% GA solution. 2) The tensile strength and thickness of these and other bioprosthesis, including fresh porcine pericardium, fresh human pericardium, and commercially produced heterografts, were measured. 3) The tensile strength and thickness of the six treated groups (GA-Ethanol, Ethanol-GA, SDS only, SDS-GA, Ethanol-SDS-GA and SDS-Ethanol-GA) were measured. Result: 1) Porcine pericardium fixed in 0.625% GA the thinnest and had the lowest tensile strength, with thickness and tensile strength increasing with the concentration of GA solution. The relationship between tensile strength and thickness of porcine pericardium increased at thicknesses greater than 0.1mm (correlation-coefficient 0.514, 0<0.001). 2) There were no differences in tensile strength or thickness between commercially-produced heterografts. 3) Treatment of GA, ethanol, or SDS minimally influenced thickness and tensile strength of porcine pericardium, except for SDS alone. Conclusion: Porcine pericardial bioprosthesis greater than 0.1 mm thick provide better handling and advantageous tensile strength. GA fixation did not cause physical or mechanical damage during anticalcification or decellularization treatment, but combining SDS-ethanol pre-treatment and GA fixation provided the best tensile strength and thickness.

STUDIES OF OSSEOINTEGRATED IMPLANT-MODELS ON STRESS DISTRIBUTION (치과용 골유착성 임플랜트 고정체 형상의 응력 분산에 관한 연구)

  • Han, Chong-Hyun;Chun, Hung-Jae;Jung, Sin-Young;Heo, Seong-Joo;Choi, Yong-Chang;Chung, Chong-Pyung;Ku, Young;Ryu, In-Chul;Kim, Myung-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.4
    • /
    • pp.526-543
    • /
    • 2000
  • Finite element analyses were performed to study effects on stress distribution generated in jaw bone for various shapes of dental implants: plateau type, plateau with small radius of curvature, triangular thread screw type in accordance with ISO regulations and square thread screw filleted with small radius partially. It was found that square thread screw filleted with small radius was more effective on stress distribution than other dental implants used in analyses. Additional analyses were performed on the implant with square thread screw filleted with small radius for very-ing design parameters, such as the width of thread end, the height of the thread of the implant and load direction, to determine the optimum dimensions of the implant. The highest stress concentration occurred at the region in jaw Pone adjacent to the first thread of the implant. The maximum effective stress induced by a 15 degree oblique load of 100 N was twice as high as the maximum effective stress caused by an equal amount of vertical load. Stress distribution was more effective in the case when the width of thread end and the height of thread were p/2 and 0.46p, respectively, where p is the pitch of thread. At last, using tensile force calculated from the possible insert torque without breading bone thread, finite element analysis was performed on the implant to calculate pre-stress when the primary fixation of the implant was operated in jaw bone. The maximum effective stress was 136.8 MPa which was proven to be safe.

  • PDF

Computer-Assisted Navigation in Total Knee Arthroplasty (내비게이션 장치를 이용한 슬관절 전치환술)

  • Jeong, Hwa-Jae;Park, Yong-Beom;Lee, Han-Jun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.53 no.6
    • /
    • pp.478-489
    • /
    • 2018
  • Total knee arthroplasty has become a standard procedure for advanced knee arthritis to relieve pain and improve function. Computer-assisted navigation systems have been used in total knee arthroplasty to improve the mechanical axis of the limb as well as the alignment and position of the components. A computer-assisted navigation system has the advantage of real-time feedback during surgery, such as mediolateral balance in extension and flexion gap, alignment of the lower limb, and components. On the other hand, the computer-assisted navigation system requires an additional stab wound for tracker fixation, which can increase the likelihood of superficial wound infection and stress fractures and increase the operation time and cost of surgery. The clinical efficacy of computer-assisted navigation in total knee arthroplasty is also controversial. Compared to the conventional technique, computer navigation improves the accuracy of the postoperative mechanical axis within outliers of $3^{\circ}$ varus or $3^{\circ}$ valgus. This paper reviews the surgical technique, pitfalls, clinical and radiological outcomes, useful clinical cases, and future perspectives in computer-assisted navigation total knee arthroplasty.

An Experimental Study on the Biomechanical Effectiveness of Bone Cement-Augmented Pedicle Screw Fixation with Various Types of Fenestrations

  • Yoon, Sang Hoon;Lee, Sang Hyung;Jahng, Tae-Ahn
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.6
    • /
    • pp.779-789
    • /
    • 2022
  • Objective : To analyze the effects of the number and shape of fenestrations on the mechanical strength of pedicle screws and the effects of bone cement augmentation (BCA) on the pull-out strength (POS) of screws used in conventional BCA. Methods : For the control group, a conventional screw was defined as C1, a screw with cannulated end-holes was defined as C2, a C2 screw with six pinholes was defined as C3, and the control group type was set. Among the experimental screws, T1 was designed using symmetrically placed thru-hole type fenestrations with an elliptical shape, while T2 was designed with half-moon (HM)-shaped asymmetrical fenestrations. T3 and T4 were designed with single HM-shaped fenestrations covering three pitches and five pitches, respectively. T5 and T6 were designed with 0.6-mm and 1-mm wider fenestrations than T3. BCA was performed by injecting 3 mL of commercial bone cement in the screw, and mechanical strength and POS tests were performed according to ASTM F1717 and ASTM F543 standards. Synthetic bone (model #1522-505) made of polyurethane foam was used as a model of osteoporotic bone, and radiographic examinations were performed using computed tomography and fluoroscopy. Results : In the fatigue test, at 75% ultimate load, fractures occurred 7781 and 9189 times; at 50%, they occurred 36122 and 82067 times; and at 25%, no fractures occurred. The mean ultimate load for each screw type was 219.1±52.39 N for T1, 234.74±15.9 N for T2, 220.70±59.23 N for T3, 216.45±32.4 N for T4, 181.55±54.78 N for T5, and 216.47±29.25 N for T6. In comparison with C1, T1, T2, T3, T4, and T6 showed significantly different ultimate load values (p<0.05). However, when the values for C2 and the fenestrated screws were evaluated with an unpaired t test, the ultimate load value of C2 significantly differed only from that of T2 (p=0.025). The ultimate load value of C3 differed significantly from those of T1 and T2 (C3 vs. T1 : p=0.048; C3 vs. T2 : p<0.001). Linear correlation analysis revealed a significant correlation between the fenestration area and the volume of bone cement (Pearson's correlation coefficient r=0.288, p=0.036). The bone cement volume and ultimate load significantly correlated with each other in linear correlation analysis (r=0.403, p=0.003). Conclusion : Fenestration yielded a superior ultimate load in comparison with standard BCA using a conventional screw. In T2 screws with asymmetrical two-way fenestrations showed the maximal increase in ultimate load. The fenestrated screws can be expected to show a stable position for the formation of the cement mass.

The Dynamic and Histologic Changes of Variously Fixed Bovine Pericardiums Specimens after Mechanical Fatigue Stimuli (다양한 고정 처리법을 이용한 소 심낭의 기계적 피로 자극 후 역학적 및 조직학적 변화)

  • Chang, Hyoung-Woo;Kim, Yong-Jin;Kim, Soo-Hwan;Park, Ji-Eun;Park, Chun-Soo;Kim, Woong-Han;Kim, Kyung-Hwan
    • Journal of Chest Surgery
    • /
    • v.42 no.2
    • /
    • pp.148-156
    • /
    • 2009
  • Background: As cardiovascular operations become more complex and sophisticated, there is an increasing need for various bioprostheses for use as components of blood vessels and heart valves. We developed a fatigue stimuli test instrument to objectively evaluate the mechanical durability of a bioprosthesis, and we tested several currently known processing methods for bovine pericardium and we then compared the results. Material and Method: Fresh bovine pericardium was collected at the butcher shop with using aseptic technique, and each piece of pericardium was fixated and/or decellularized by 16 representative methods. We measured the permeability and compliance of the processed bovine pericardium samples, and measured them again after exposure to the fatigue stimuli. All the pieces of pericardium underwent microscopic examinations before and after the fatigue stimuli. Result: A mixture of glutaraldehyde and solvent treatment showed better mechanical durability than did the single glutaraldehyde treatment. High concentration glutaraldehyde treatment showed equal or no worse results than did low concentration glutaraldehyde treatment. After SDS (sodium dodecylsulfate) decellularization, the mechanical property of the bioprosthesis became much worse ($20{\sim}190$ times) and the mechanical durability to the fatigue stimuli was also very poor. Conclusion: We obtained the basic durability data after various fixation methods with using a home-made fatigue test instrument.

Comparative Study of Compliance for Venous Thromboembolism Prophylaxis (American College of Chest Physicians Guideline and American College of Orthopedic Surgeons Guideline) in High Risk Patients with a Venous Thromboembolism (정맥혈전 색전증 고위험군에서 시행한 혈전색전 예방요법(American College of Chest Physicians 지침 및 American College of Orthopedic Surgeons 지침)의 준수율 비교 연구)

  • Suh, You-Sung;Nho, Jae-Hwi;Jang, Byung-Woong;Kang, Deokwon;Won, Sung-Hun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.4
    • /
    • pp.317-326
    • /
    • 2019
  • Purpose: To compare and analyze the rate of prevention of two venous thromboembolism prophylaxis guidelines in patients with artificial joint arthroplasty and hip joint fracture. Proper prophylaxis for preventing thromboembolism in orthopedic surgery is significant because of this fetal complication. Materials and Methods: This study compared and retrospective analyzed the rate of prevention using the medical records and radiographs of patients who underwent orthopedic surgery from March 2009 to February 2011 according to the American College of Chest Physicians (ACCP) guidelines and from March 2012 to February 2014 according to the American Academy of Orthopedic Surgeons (AAOS) guidelines. Results: The guidelines for venous thromboembolism prophylaxis have been applied to patients with artificial joint replacement and hip joint fracture, the compliance rate of the ACCP guidelines was 56.0% before surgery, 67.0% after surgery with chemical prophylaxis, and 80.5% with mechanical prophylaxis. In addition, the compliance rate of the AAOS guidelines was 74.1% with chemical prophylaxis, and 88.3% with mechanical prophylaxis, which was higher than the ACCP guidelines. The compliance rates of mechanical and chemical prophylaxis before and after surgery of the ACCP guidelines, and the compliance rate of mechanical and chemical prophylaxis of the AAOS guidelines were compared and analyzed. The results revealed statistical significance (p<0.05) before and after total knee replacement arthroplasty and hip joint fracture internal fixation and total high risk orthopedic surgery. Conclusion: Raising the compliance rate of prophylaxis of venous thromboembolism in high risk orthopedic surgery is necessary and people should follow the guidelines for a unified direction depending on which situation they are in.

A Study on the Effects of the Early Use of Nasal CPAP in the Weaning of Mechanical Ventilators (인공호흡기 이탈시 비강내 CPAP 조기 사용 효과에 관한 연구)

  • Kim, Yeoung Ju;Jung, Byun Kyung;Lee, Sang Geel
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.12
    • /
    • pp.1200-1206
    • /
    • 2003
  • Purpose : This study was conducted for the use of nasal continuous positive airway pressure (CPAP), by comparing the early use of non-invasive nasal CPAP with low intermittent mandatory ventilation(low IMV) and endotracheal CPAP in weaning a mechanical ventilator from infants with moderate respiratory distress syndrome(RDS). Methods : Thirty infants in the study group, with moderate RDS from November 2001 to June 2002, were administered surfactants and treated with the mechanical ventilator, and applied the nasal CPAP in weaning. Thirty infants of the control group, from January 1999 to September 2001, were applied low IMV and endoctracheal CPAP in weaning. Results : There were no significant differences in the characteristics, the severity of clinical symptoms, the initial laboratory findings and settings of the mechanical ventilator. After weaning, the study group showed no significant changes in $PaCO_2$. However, the control group showed a slight $CO_2$ retension after one and 12 hours. Twenty eight infants(93.3%) of the study group and 24 infants(80%) of the control group were successfully extubated. The primary cause of failure was apnea. There were no significant differences in the duration of weaning and the mechanical ventilator treatment between the groups. Complications in weaning were related to the fixation of nasal CPAP and the mechanical problems caused by endotracheal tube. Conclusion : Aggressive weaning is possible for moderate RDS, in which the nasal CPAP was used without the low IMV and the endotracheal CPAP process. It had no difficulties. In conclusion, the nasal CPAP is an adequate weaning method for moderate RDS.

THE THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF STRESS DISTRIBUTION AND DISPLACEMENT IN MANDIBLE ACCORDING TO TREATMENT MODALITIES OF MANDIBULAR ANGLE FRACTURES (하악각 골절의 치료 방법에 따른 하악골의 응력 분포 및 변위에 관한 삼차원 유한요소법적 연구)

  • Ku, Je-Hoon;Kim, Il-Kyu;Chang, Jae-Won;Yang, Jung-Eun;Sasikala, Balaraman;Wang, Boon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.3
    • /
    • pp.207-217
    • /
    • 2010
  • The purpose of this study was to evaluate the effects of the stress distribution and displacement in mandible according to treatment modalities of mandibular angle fractures, using a three dimensional finite element analysis. A mechanical model of an edentulous mandible was generated from 3D scan. A 100-N axial load and four masticatory muscular supporting system were applied to this model. According to the number, location and materials of titanium and biodegradable polymer plates, the experimental groups were divided into five types. Type I had a single titanium plate in the superior border of mandibular angle, type II had two titanium plates in the superior tension border and in the inferior compression border of mandibular angle, type III had a single titanium plate in the ventral area of mandibular angle, type IV had a single biodegradable polymer plate in the superior border of mandibular angle, type V had a single biodegradable polymer plate in the ventral area of mandibular angle. The results obtained from this study were follows: 1. Stress was concentrated on the condylar neck of the fractured side except Type III. 2. The values of von-Mises stress of the screws were the highest in the just-posterior screw of the fracture line, and in the just-anterior screw of Type III. 3. The displacement of mandible in Type III was 0.04 mm, and in Type I, II, IV, and V were 0.10 mm. 4. The plates were the most stable in the ventral area of mandibular angle (Type III, V). In conclusion, the ventral area of mandibular angle is the most stable location in the fixation of mandibular angle fractures, and the just- posterior and/or the just-anterior screws of the fracture line must be longer than the other, and surgeons have to fix accurately these screws, and the biodegradable polymer plate also was suitable for the treatment of mandible angle fracture.