• Title/Summary/Keyword: mechanical fixation

Search Result 112, Processing Time 0.031 seconds

A CLINICAL STUDY ON THE ATTACHMENT-FIXATION OVERDENTURE (I) - Preliminary Periodontal Status Study - (ATTACHMENT-FIXATION OVERDENTURE에 관한 임상적 연구(I))

  • Yang, Jae-Ho
    • The Journal of the Korean dental association
    • /
    • v.22 no.11 s.186
    • /
    • pp.953-960
    • /
    • 1984
  • The author applied the attachment fixation overdenture on the patient whose residual alveolar ridge height was poor to increase mechanical denture retention, and observed the periodontal condition of the abutment roots after insertion of attachment fixation overdenture. The author obtained the conclusions as follows; 1. Attachment fixation overdenture showed better mechanical retention than conventional overdenture did, but it resulted unfavorable crown-root ratio. 2. Within one year after insertion, there were not significant changes in periodontal health, which was indicated by plaque index, gingival index, pocket depth, tooth mobility gingival hyperplasia and alveolar bone change. 3. Mild periodontal thickening was observed. 4. This study emphasized the importance of adequate follow-up care and home care instructions.

  • PDF

Surgical immobilization using Judet`d strut for flail chest with multiple rib fractures (다발성 늑골골절에 의한 동요흉에서 늑골고정판을 사용한 늑골고정술)

  • 구자홍
    • Journal of Chest Surgery
    • /
    • v.26 no.1
    • /
    • pp.64-66
    • /
    • 1993
  • We experienced 2 cases of surgical immobilization with Judet`s strut for flail chest with multiple rib fractures. The patients were undertaken explorative thoracotomy for unevacuated hematoma and chest wall fixation for paradoxically moving segments of ribs after initial trials of internal fixation, i.e. mechanical ventilation with endotracheal intubation. Immediately after operation, the patient`s general condition and respiratory status were improved remarkably. Mechanical ventilation and endotracheal intubtion were removed on postoperative second day without any events.

  • PDF

Analysis of Mechanical Fixation Made of Aluminum Alloy in an Axial Flux Permanent Magnet Machine

  • Lee, Jiyoung;Park, Byounggung;Koo, Daehyun
    • Journal of Magnetics
    • /
    • v.19 no.3
    • /
    • pp.309-313
    • /
    • 2014
  • This paper presents an eddy current loss analysis of a Mechanical Fixation (MF) made of 6061 aluminum alloy, which is used for an NS type double-rotor single-stator axial flux permanent magnet machine. The prototype MF made of aluminum alloy shows good mechanical performance, but poor electro-magnetic performance, since the machine's efficiency can decrease because of eddy current loss in the MF. In order to prevent efficiency decrease, a modification of the MF structure is also introduced. Three-dimensional finite element analysis (FEA) is used for magnetic field analysis, and eddy current losses are computed. The analysis results are compared to, and verified by the test results.

The Posterior Cruciate Ligament (PCL) Reconstruction by the Transtibial Tunnel Method using Cadaveric Achilles Tendon Grafts - Evaluation of the Initial Lengthening and the Slippage Ratio due to the Interference Screw Fixation and Double Cross-Pin Fixation - (사체 아킬레스건을 이용한 경골관통터널방식의 후방십자인대 재건술 - 간섭나사 및 이중고정핀 방식에 따른 초기연신 및 활주율 평가 -)

  • Kim, Cheol-Woong;Bae, Ji-Hoon;Oh, Dong-Joon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.4
    • /
    • pp.430-439
    • /
    • 2009
  • Posterior Cruciate Ligament (PCL) plays an important role in knee extension. Rotational instability due to injured PCL can be restored by various PCL reconstruction methods. In this study, the initial lengthening affected by fixation device and location was demonstrated, and furthermore, the slippage and the relationship between lengthening ratio and slippage ratio in the calcaneus and soft tissue fixation methods was newly suggested. Eight specimens of proximal tibia and Achilles tendon grafts were harvested from four cadavers and divided into four groups in regard to the four different types of transtibial fixation techniques. The cyclic load ranged from 50 N to 250 N applied to each graft fixed to proximal tibia in 55 degrees. The initial lengthening ratio to the total elongation has been approximately constant regardless of the fixation methods. The soft tissue fixation method with an interference screw showed about 56.4% slippage ratio to the total elongation and the same method with a double cross-pin presented about 45.4% slippage ratio. The soft tissue fixation method with an interference screw demonstrated approximately 2 mm less total elongation and about 13% more slippage than lengthening because of poor fixation compared to the same method with a double cross-pin.

Effect of DP Finishing Conditions on the Mechanical Properties and Hand of Cotton Fabrics (DP 가공조건이 면직물의 역학적 성질과 태에 미치는 영향)

  • 신윤숙
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.24 no.3
    • /
    • pp.440-447
    • /
    • 2000
  • The effects of DP finishing conditions including process technique and finishing agent on the mechanical properties and hand of cotton fabrics were investigated. 100% cotton fabrics were treated with NMA/DMDHEU and NMA/YF using wet-fixation and steam-fixation process. For comparison, conventional pad-dry-cure process was used with DMDHEU. After DP finishing, tensile and compressional resilience increased and bending hysteresis decreased, resulting in the improvement of dimensional stability of cotton fabric. WF and SF process rendered fabrics better shear properties, tensile energy, and compressional linearity and energy than PDC process. However, SF process produced fabrics with higher geometrical roughness than WF process. After DP finishing, primary hand values except Koshi increased, resulting in the increase of total hand value of cotton fabric.

  • PDF

Fixation of Compression Set of Heat-Compressed Wood by Steaming (수증기 처리에 의한 열압밀화목재의 압축 고정)

  • 이원희;한규성
    • Journal of the Korea Furniture Society
    • /
    • v.11 no.1
    • /
    • pp.85-89
    • /
    • 2000
  • This study investigated the effect of steaming on fixation of compression set and the effect of these treatments on mechanical properties of heat-compressed wood specimens. To determine the effect of steaming after compression set, wood specimens were compressed for 100min at 180f and then steamed for 20-100min at $120^{\circ}C$. Swelling tests were used to evaluate recovery of compression set. Bending, compression, and Brinell hardness tests were carried out for evaluating mechanical properties. Compressed wood steamed for 100 min at $120^{\circ}C$ showed 1.9% recovery of set, increases in bending and compressive properties, and no hardness change. We concluded that almost complete fixation of compression set in wood can be achieved by steaming compressed wood.

  • PDF

Straight-Forward versus Bicortical Fixation Penetrating Endplate in Lumbosacral Fixation-A Biomechanical Study

  • Karakasli, Ahmet;Acar, Nihat;Uzun, Bora
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.2
    • /
    • pp.180-185
    • /
    • 2018
  • Objective : Many lumbosacral fixation techniques have been described to offer a more screw-bone purchase. The forward anatomical fixation parallel to the endplate is still the most preferred method. Literature revealed little knowledge regarding the mechanical stability of lumbosacral trans-endplate fixation compared to the traditional trans-pedicular screw fixation method. The aim of this study is to assess the pull-out strength of lumbosacral screws penetrating the end plate and comparing it to the conventional trans-pedicular screw insertion method. Methods : Eight lumbar and eight sacral vertebrae, with average age 69.4 years, Left pedicles of the 5th lumbar vertebrae were used for trans-endplate screw fixation, group 1A, right pedicles were used for anatomical trans-pedicular screw fixation, group 1B. In the sacral vertebrae, the right side S1 pedicles were used for trans-endplate fixation, group 2A, left side pedicles were used for anatomical trans-pedicular screw fixation, group 2B. The biomechanical tests were performed using the axial compression testing machine. All tests were applied using 2 mm/min traction speed. Results : The average pull-out strength values of groups 1A and 1B were $403.78{\pm}11.71N$ and $306.26{\pm}17.55N$, respectively. A statistical significance was detected with p=0.012. The average pull-out strength values of groups 2A and 2B were $388.73{\pm}17.03N$ and $299.84{\pm}17.52N$, respectively. A statistical significance was detected with p=0.012. Conclusion : The trans-endplate lumbosacral fixation method is a trustable fixation method with a stronger screw-bone purchase and offer a good alternative for surgeons specially in patients with osteoporosis.

A comparison of fixation methods using three-dimensional finite element analysis following anterior segmental osteotomy

  • Yun, Kyoung In;Park, Min-Kyu;Park, Myung-Kyun;Park, Je Uk
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.38 no.6
    • /
    • pp.332-336
    • /
    • 2012
  • Objectives: This study sought to evaluate fixation methods and determine the best method for the postoperative stabilization of maxillary osteotomy. For our analysis we performed a three-dimensional finite element analysis of stress distribution on the plate, screw, and surrounding bone, as well as displacement onto the plate. Materials and Methods: We generated a model using synthetic skull scan data; an initital surface model was changed to a solid model using software. Modified anterior segmental osteotomy (using Park's method) was made using the program, and four different types of fixation methods were used. An anterior load of 100 N was applied on the palatal surface of two central incisors. Results: The Type 1 (L-shaped) fixation method gave stresses of 187.8 MPa at the plate, 45.8 MPa at the screw, and 15.4 MPa at the bone around the plate. The Type 2 (I-shaped) fixation method gave stresses of 186.6 MPa at the plate, 75.7 MPa at the screw, and 13.8 MPa at the bone around the plate. The Type 3 (inverted L-shaped) fixation method gave stresses of 28.6 MPa at the plate, 29.9 MPa at the screw, and 15.3 MPa at the bone around the plate. The Type 4 (I-shaped) fixation method gave stresses of 34.8 MPa at the plate, 36.9 MPa at the screw, and 14.9 MPa at the bone around the plate. The deflection of the plates for the four fixation methods was 0.014 mm, 0.022 mm, 0.017 mm, and 0.018 mm, respectively. Conclusion: The Type 3 (inverted L-shaped) fixation method offers more stability than the other fixation methods. We therefore recommend this method for the postoperative stabilization of maxillary osteotomy.

Application of Bioabsorbable Plates in Orthognathic Surgery

  • Kim, Young-Kyun;Shim, Cheong-Hwan;Bae, Ji-Hyun;Yun, Pil-Young
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.32 no.1
    • /
    • pp.60-64
    • /
    • 2006
  • Backgrounds: Though they are considered as reliable devices, titanium plates and screws have limitations due to some potential problems. To overcome these problems, researches on bioabsorbable materials for internal fixation have been continuing. Recently, there are many clinical trials to apply biodegradable internal fixation devices in oral and maxillofacial surgery. The purpose of this study was to evaluate the clinical results of application of bioabsorbable plates and screws in orthognathic surgery. Methods: Fifty-four patients with dentofacial deformity (17 male patients and 37 female patients) were selected in this study. The patients were treated by internal fixation using bioabsorbable plates and 2.4-mm, 2.0-mm pretapped screws (Biosorb FX, Bionix Implants, Inc., Finland). The patients were evaluated for complications during the follow-up period. Results: Five patients (9.3%) experienced complications. All complications in these cases were infection. No other complications related with physical or mechanical properties of bioabsorbable plates were found such as malunion or nonunion, fractures of plates and loosening of screws. All complications were minor and adequately managed with drainage and supportive care with antibiotics coverage. Conclusions: From the results, the use of these fixation systems in orthognathic surgery will provide a promising alternative titanium fixation in appropriate cases.