• 제목/요약/키워드: mechanical drop analysis

검색결과 463건 처리시간 0.03초

Prandtl 수에 따른 옵셋 스트립 핀에서의 열 및 유동 분석 (Thermo-Flow Analysis of Offset-Strip Fins according to Prandtl Number)

  • 주윤식;공동현;이관수
    • 설비공학논문집
    • /
    • 제21권6호
    • /
    • pp.340-346
    • /
    • 2009
  • This paper numerically investigates thermo-flow characteristics of offset strip fins to obtain a correlation between heat transfer and pressure drop. The flow was divided into three regimes, i.e. laminar, transition and turbulent. The predicted j and f values from the SST k-$\omega$ turbulence model agreed with previous correlations with the error less than 20% in transition and turbulent regimes. Heat transfer and pressure drop were predicted by varying Prandtl number from 0.5 to 40. The Prandtl number showed little effects on pressure drop but had great effect on the heat transfer characteristics. An overall correlation to predict j was suggested by incorporating the effect of Pr and a new j correlation was suggested for each Pr.

Plandtl 수에 따른 옵셋 스트립핀에서의 열 및 유동 분석 (Thermo-Flow Analysis of Offset-strip fins according to Prandtl Number)

  • 주윤식;김민수;이관수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.233-238
    • /
    • 2008
  • This paper numerically investigates thermo-flow characteristics of offset strip fins to obtain a correlation between heat transfer and pressure drop. The flow was divided into three regimes, i.e. laminar, transition and turbulent. The predicted j and f values from the SST k-$\omega$ turbulence model agreed with previous correlations with the error less than 20% in transition and turbulent regimes. Heat transfer and pressure drop were predicted by varying Prandtl number from 0.5 to 40. The Prandtl number showed little effects on pressure drop but had great effect on the heat transfer characteristics. An overall correlation to predict j was suggested by incorporating the effect of Pr and a new j correlation was suggested for each Pr.

  • PDF

충격해석을 통한 결과의 예측 (The Prediction of the Results of Drop Test Through Shock Analysis)

  • 박용석;홍성철;박철희;이우식;조항법
    • 소음진동
    • /
    • 제4권3호
    • /
    • pp.345-352
    • /
    • 1994
  • Electronic products can be subjected to many different forms of shock. These shocks are usually experienced during transporting the electronic products from a manufacturer to customers. Drop tests are performed to test the product fragility before shipment. Package cushioning materials are often used to protect electronic products from severs shock environments. In the present paper, an algorithm to predict the shock responses of the main mechanical parts is developed by use of the shock analysis in which the modal parameters extracted from vibration test are used. These results are in good agreement with the results of drop test. By use of the shock response prediction algorithm developed herein, it is possible to predict the results of drop test at various drop directions and also to select the optimal package cushioning materials.

  • PDF

평행류 열교환기 내부의 열유동 해석 (Heat and Flow Analysis Inside a Parallel-Flow Heat Exchanger)

  • 오석진;정길완;이관수
    • 대한기계학회논문집B
    • /
    • 제27권6호
    • /
    • pp.781-788
    • /
    • 2003
  • In the present study, the heat and flow characteristics of a parallel-flow heat exchanger are numerically analyzed by using three-dimensional turbulent modeling. Heat transfer rate and pressure drop are evaluated using the concept of the efficiency index by varying the locations, the shapes and angles of inlet/outlet, and the protrusion height of flat tube. It is found that negative angle of the inlet improves the heat transfer rate and pressure drop. Results show that the locations of the inlet and outlet should be toward the right side and the left side to the reference model, respectively, in order to enhance the heat transfer rate and pressure drop. Increasing the height of the lower header causes pressure drop to decrease and yields the good flow characteristics. The lower protrusion height of flat tube shows the improvement of the heat transfer rate and pressure drop. The heat transfer rate is greatly affected by the parameters of outlet side such as the location and angle of the outlet. However, the pressure drop is influenced by the parameters of inlet side such as the location and angle of inlet and the height of the header.

AMTEC의 소디움액체 순환윅에서 압력손실 및 열손실해석 (Analysis of Pressure Drop and Heat Loss in Liquid Sodium Circulation Wick of AMTEC)

  • 이기우;이욱현;이석호;이계복
    • 대한기계학회논문집B
    • /
    • 제36권9호
    • /
    • pp.953-960
    • /
    • 2012
  • AMTEC기술은 열을 직접 전기로 변환시키는 기술로서 소디움을 작동유체로 사용하고 있으며, 작동유체의 순환은 모세관윅을 사용한다. 순환계통에는 증발부윅, 순환윅 및 응축부윅으로 구성되고, 각각의 윅은 소디움의 액체 또는 증기가 순환하면서 압력손실이 발생하므로 소디움의 순환을 위해서는 증발부윅의 모세관압력이 윅내의 총압력손실보다 커야만 한다. 본 연구에서는 100 watt급의 AMTEC시제품설계을 위해 소디움의 순환계통으로 구성되는 증발부윅, 순환윅 및 응축부윅에서의 압력손실과 증발부에서 응축부로의 열손실을 순환윅의 직경과 길이에 대해 분석하여 증발부윅의 소결입자 직경과 순환윅의 설계에 활용하코저 하였으며, 분석결과에서 순환계통의 총압력손실보다 큰 모세관압력을 위해서는 증발부윅의 소결입자크기는 10 ${\mu}m$이 적합한 결과를 얻었다.

난류 발생기의 형상에 따른 수직 PCB채널에서의 열전달 및 압력손실 변화 (Heat transfer and pressure drop with the turbulence promoter in a vertical PCB Channel)

  • 박찬우;장승일;정종수;남평우
    • 대한기계학회논문집B
    • /
    • 제20권7호
    • /
    • pp.2277-2288
    • /
    • 1996
  • This study was performed to analyze the cooling effect of heated ribs which are frequently used for cooling of electronic parts, using the numerical method. To prevent the excessive pressure drop due to turbulence promoters for the enhancement of heat transfer rate especially, the effect of the angle of turbulence promoter was investigated by the numerical analysis. Heat transfer rate with turbulence promoters with rectangular cross-section increased by 13% in average, but the coefficient of pressure drop increased by 1.68 times than that without them. In the present study, triangular cross-sectional shape turbulence promoters were suggested and numerically tested. Pressure drop of turbulence promoter with the 30 degree triangular cross-sectional shape decreased by 30% from that of rectangular cross-section promoters while heat transfer rate was almost the same. While with 4 turbulence promoters, the heat transfer rate increased by 21%, the pressure drop increased 4 times. It means that the higher capacity of cooling fan should be needed. With the triangular cross-sectional shape, the size of vortex region at the rear of promoters became considerably smaller, so pressure drop became smaller. The effect of the change of cross-sectional shape was not found in the flow pattern near the ribs, so that heat transfer characteristics in the ribs were not changed.

A comparative analysis of sheeting die geometries using numerical simulations

  • Igali, Dastan;Wei, Dongming;Zhang, Dichuan;Perveen, Asma
    • Advances in Computational Design
    • /
    • 제5권2호
    • /
    • pp.111-125
    • /
    • 2020
  • The flow behavior of polymer melts within a slit die is an important consideration when designing a die geometry. The quality of the extruded polymer product can be determined through an evaluation of the flow homogeneity, wall shear rate and pressure drop across the central height of the die. However, mathematical formulations cannot fully determine the behavior of the flow due to the complex nature of fluid dynamics and the nonlinear physical properties of the polymer melts. This paper examines two slit die geometries in terms of outlet velocity uniformity, shear rate uniformity at the walls and pressure drop by using the licensed computational fluid dynamics package, Ansys POLYFLOW, based on the finite element method. The Carreau-Yasuda viscosity model was used for the rheological properties of the polypropylene. Comparative analysis of the simulation results will conclude that the modified die design performs better in all three aspects providing uniform exit velocity, uniform wall shear rates, and lower pressure drop.

Parametric study on the structural response of a high burnup spent nuclear fuel rod under drop impact considering post-irradiated fuel conditions

  • Almomani, Belal;Kim, Seyeon;Jang, Dongchan;Lee, Sanghoon
    • Nuclear Engineering and Technology
    • /
    • 제52권5호
    • /
    • pp.1079-1092
    • /
    • 2020
  • A parametric study of several parameters relevant to design safety on the spent nuclear fuel (SNF) rod response under a drop accident is presented. In the view of the complexity of interactions between the independent safety-related parameters, a factorial design of experiment is employed as an efficient method to investigate the main effects and the interactions between them. A detailed single full-length fuel rod is used with consideration of post-irradiated fuel conditions under horizontal and vertical free-drops onto an unyielding surface using finite-element analysis. Critical drop heights and critical g-loads that yield the threshold plastic strain in the cladding are numerically estimated to evaluate the fuel rod structural resistance to impact load. The combinatory effects of four uncertain parameters (pellet-cladding interfacial bonding, material properties, spacer grid stiffness, rod internal pressure) and the interactions between them on the fuel rod response are investigated. The principal finding of this research showed that the effects of above-mentioned parameters on the load-carrying capacity of fuel rod are significantly different. This study could help to prioritize the importance of data in managing and studying the structural integrity of the SNF.

프레임이 적용된 스탬프 베이스의 동특성 분석 (Analysis of dynamic characteristic applying frame on stamped base in 2.5 inch hard disk drive)

  • 임건엽;박노철;박경수;김석환
    • 정보저장시스템학회논문집
    • /
    • 제9권2호
    • /
    • pp.51-55
    • /
    • 2013
  • HDD has been easily exposed to the external shock and vibration because HDD has to apply to mobile devices. Therefore, the stiffness of base has been the important factors for the design of HDD. To improve the stiffness of base, the frame was applied to the base. First, the finite element model of the base was constructed. Then, the FE model was verified by modal analysis. Drop test was performed to confirming the shock simulation model. The dynamic characteristic of original base which is verified is compared with the base which is applied the frame through modal analysis and shock analysis.