• Title/Summary/Keyword: mechanical device

Search Result 2,854, Processing Time 0.032 seconds

Communication device to use slight body movement for ALS patients

  • Fukuda, Yoshio;Yamanaka, Yuuki;Tanaka, Motohiro;Ishimatsu, Takakazu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1963-1967
    • /
    • 2003
  • Communication device to use slight movement for serious disabled is proposed. This device is developed mainly for patients suffering from ALS or a cerebral infarction. They often have communication difficulty because of deterioration of muscular functions. Features of this device are that the device is wearable on the user’s body and that it detects the movement of eyebrow. Because of these features, it is quite easy to install the sensor on the patient’s body, not like the conventional sensors. Furthermore, an adaptive communication software is incorporated. A feature of this software is that the arrangement and size of the button and window on the display can be optimized depending on the user's physical ability. In the field test it is confirmed that the communication device developed in this study is successfully helped the people with disability for increasing their communication ability.

  • PDF

Durability of the Flexible Shape Memory Device (형상 기억 유연 소자의 내구성 평가에 관한 연구)

  • Yang, Hee-Kyung;Kim, Hae-Jin;Kim, Dae-Eun
    • Transactions of the Society of Information Storage Systems
    • /
    • v.11 no.2
    • /
    • pp.36-40
    • /
    • 2015
  • The demand for flexible devices including solar cells, memories and batteries has increased rapidly over the past decades. In most flexible devices, polymer-based materials are used to enable the mechanical deformations such as bending or folding. Shape Memory Polymers (SMPs) is a high molecular compound polymer with flexibility and shape recovery characteristics. In this work, flexible shape memory device was fabricated by simply coating the conducting material, carbon nano-tube (CNT), on a shape memory polymer. Furthermore, durability of the device under various type of mechanical deformations was assessed. It is believed that the result of this work will aid in realization of a stretchable and wearable electronic device for practical applications.

Practicability Assessment of Spherical Mechanical Check Device(SMCD) (Mechanical Check용 Spherical device의 제작 및 특성 평가)

  • Lee, Byung-Koo;Yang, Dae-Sik;Kweon, Young-Ho;Ko, Shin-Gwan;Han, Dong-Kyoon
    • Journal of radiological science and technology
    • /
    • v.30 no.2
    • /
    • pp.153-159
    • /
    • 2007
  • Digital medical image commenced with an introduction of PACS has become more popular today in the radiation diagnosis and radiation treatment and made great progress, in particular, for medical testing field, whereas it has made slow progress for radiation treatment field. In order to accommodate the current trend of digital from analog, a spherical mechanical check device(SMCD) that is the form of spherical differing from the existing form of flat or cube has been designed and tested its practicability to replace the part in mechanical check with digital image from QA operation. If the distance maintains constance between source(target) and image detector with constant distance to the center of spherical mechanical check device(SMCD), the size will be shown as a constant image at all times regardless of its direction exposed. For the test, two accurate hemispheres are made and put together which results in a sphere of the equilateral circle. It enables a variety of implementation of the existing mechanical check using digital image as follows: congruity level of radiation field and light field, size accuracy of radiation field and collimation field, gantry rotation isocenter check, collimation rotation isocenter check, room laser accuracy check, collimation rotation angle check, couch rotation angle check, and more. In addition, it has proved its practicability in checking isocenter congruity level as real time at the time of simultaneous rotation between gantry and couch that is applied to the non-coplanar field, which had been hard to apply as a device formed of existing flat or cube.

  • PDF

A Triboelectric Nanogenerator Design for the Utilization of Multi-Axial Mechanical Energies in Human Motions

  • Ryoo, Hee Jae;Lee, Chan Woo;Han, Jong Won;Kim, Wook;Choi, Dukhyun
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.5
    • /
    • pp.312-322
    • /
    • 2020
  • As the use of mobile devices increase, there is public interest in the utilization of the human motion generated mechanical energy. The human motion generated mechanical energies vary depending on the body region, type of motion, etc., and an appropriate device has to be designed to utilize them effectively. In this work, a device based on the principles of triboelectric generation and inertia was assessed in order to utilize the multi-axial mechanical energies generated by human motions. To improve the output performance we confirm the changes in the output that vary with the structural design, the reasons for such changes, and variations in performance based on the parts of the human body. In addition, the level of electrical energy generated based on motion type was measured; a maximum voltage of 30 V and a current of 2 ㎂ were generated. Finally, the proposed device was utilized in LEDs used for lighting, thus demonstrating that multi-axial mechanical energies can be harvested effectively. Based on the results, we expect that the developed device can be utilized as a sensor to detect mechanical energies, to sense changes in motion, or as a generator for auxiliary power supply for mobile devices.

Development of Vibration Absorption Device for the Transportation-Trailer System(II) - Connecting Hitch for Power Tiller-Trailer - (수송 트레일러의 충격흡수장치 개발(II) - 동력경운기 연결 히치 -)

  • Hong J. H.;Lee H. J.;Lee S. B.;Park W. Y.;Kim S. Y.
    • Journal of Biosystems Engineering
    • /
    • v.30 no.3 s.110
    • /
    • pp.147-154
    • /
    • 2005
  • The improved hitch device, which connecting the trailer to power tiller, was developed. This device, composed with spring and rubber, could reduce the vibration and shock levels during driven on off-road. The vertical vibration accelerations for the improved hitch device were measured at 6 positions, i.e. engine, hitch, seat, and three points in trailer (front, middle, and rear) for not driving but at low engine speed of 500 rpm, and compared with the existing hitch device. The results of this study could be summarized as follows; The average vibration acceleration up to 120 Hz was $0.4m/s^2$ at engine part, but it was 0.08 and $0.05m/s^2$ at trailer for existing and improved hitch device, respectively. About $38\%$ of average acceleration level could be absorbed for the improved hitch device compared with existing hitch device. The average vibration acceleration up to 40 Hz was reduced to 0.12 and $0.06m/s^2$ at trailer for existing and improved hitch device respectively, showing the reduction effect of $50\%$. The maximum acceleration occurred at up to 20 Hz of low frequency was much higher than total acceleration occurred at up to 120 Hz, which means that much loss or damage could be occurred during transporting of agricultural products on off-road. The portions of average acceleration occurred at up to 20 Hz of low frequency were $27\%\;and\;21\%$ for the existing and improved hitch device, respectively.

Study for Mechanical and Physicochemcial Properties of Silicone Gel Filled Mammary Implants (실리콘겔 인공유방의 기계적 및 물리화학적 특성에 대한 연구)

  • Baek, H.;Jang, D.H.;Song, J.M.;Lee, S.Y.;Seo, M.Y.;Park, G.J.;Maeng, E.H.
    • Journal of Biomedical Engineering Research
    • /
    • v.33 no.2
    • /
    • pp.89-97
    • /
    • 2012
  • The purpose of this study is to develop the guideline of the physicochemical and mechanical properties evaluation for silicone gel filled breast implants. First of all, the use and development status for silicone gel filled breast implants were investigated, and then, standard and criteria about performance evaluation established by the international organizations such as ASTM, FDA guidance and ISO were examined. To evaluate the mechanical properties, data research and testing for breaking strength, elongation, tensile set, joint intensity, silicone gel cohesion, weight loss from heating, static rupture resistance, impact resistance test, fatigue test, and gel bleed were performed. On the other hand, to evaluate the physicochemical properties, volatile matter, extent of cross linking, heavy metals, and extractable were analyzed. In this study, results for general function, mechanical properties and physicochemical properties were examined and reviewed for the accordance with international standard, and objective and standardized guideline was provided.

Development of Arm Fire Device for Solid Rocket (고체 추진기관 점화안전장치 개발)

  • Jang Seung-Gyo;Jung Jin-Suk;Kim In-Suk
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.169-172
    • /
    • 2005
  • The performance test result of the Arm Fire Device(Ignition Safety Device) for solid rocket which prevents accidental ignition was described. The results of the closed bomb test and the igniter test of the classical mechanical arm fire device and the advanced electro-mechanical arm fire device were presented, and according to the igniter test result it was realized that the electro-mechanical arm fire device has an advantage in aspect of the action time.

  • PDF

Study on the Stability of Force Control using a 6-axis Compliance Device with F/T Sensing (F/T측정 기능을 갖는 6축 순응장치를 이용한 힘제어 안정성 연구)

  • Gi-Seong Kim;Sung-Hun Jeong;Han-Sung Kim
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.1
    • /
    • pp.211-215
    • /
    • 2023
  • In this paper, the stability and effectiveness of the force control with a 6-axis compliance device are verified by performing comparative experiments with a commercial F/T sensor. The position/force control algorithm based on the Cartesian stiffness of a compliance device is briefly introduced and the design result of a 6-axis compliance device with F/T sensing is presented. The comparative experiments show that the force control using a compliance device is much more stable than that with rigid F/T sensor due to the enough compliance of a compliance device larger than robot positional resolution.

Design and Evaluation of Portable Forward Osmosis Desalination Device (휴대용 정삼투 담수화 장치의 설계 및 평가에 관한 연구)

  • Park, Chul-Woo;Kang, Ho;Jung, Dongho;Cha, Jaechul;Kim, Daejoong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.3
    • /
    • pp.301-305
    • /
    • 2013
  • This study aims to design a portable desalination device and discusses the feasibility of the device for overcoming a shortage of safe drinking water. A low-energy, self-supporting, and portable desalination device is designed based on forward osmosis (FO) using an ammonium bicarbonate solution. Experiments with various concentrations of ammonium bicarbonate solution and sodium chloride solution showed that the portable desalination device's performance such as volume and flow rate of desalting water and time required satisfied drinking water standards. The device performance is controlled by varying the concentration and temperature of the solution.

Postcardiotomy Mechanical Circulatory Support in Congenital Heart Diseases (소아개심술 후 시행한 순환보조장치의 임상적 고찰)

  • 권오춘;이영탁
    • Journal of Chest Surgery
    • /
    • v.33 no.5
    • /
    • pp.385-390
    • /
    • 2000
  • Background: To review the experience that used both ventricular assist device(VAD) and extracorporeal membrane oxygenation(ECMO) for children with congential heart disease requiring postcardiotomy mechanical circulatory support. Material and Method: Between March 1993 and May 1995, we applied mechanical assist device using centrifugal pump to the 16 patients who failed to be weaned from cardiopulmonary bypass(n=15) or had been in cardiogenic shock in intensive care unit(n=1). The diagnosis were all congenital heart diseases and the ages of patients ranged from 20 days to 10 years (mean age=2.5$\pm$3.5 years). Result: The methods of mechanical circulatory support were LVAD(n=13), BVAD (n=1), and ECMO(n=2). The mean assist times were 54.0$\pm$23.7 hours. Post-assist complications were in orders: bleeding, acute renal failure, ventricular failure, respiratory failure, infection, and neurologic complication. It was possible for 9 patients(56.3%) to be weaned from assist device and 5 patients(31.3%) were discharged from hospital. There was no statistical significant between hospital discharged group and undischarged group by age, body weight, cardiopulmonary bypass time, and assist time. Conclusion: The ventricular assist device is an effective modality in salvaging the patient who failed to be weaned from cardiopulmonary bypass, but multiple factors must be considered for improving the results of mechanical circulatory support ; such as patient selection, optimal time of starting the assist device, and prevention and management of the complications.

  • PDF