• 제목/요약/키워드: mechanical connection

검색결과 547건 처리시간 0.039초

Shear transfer mechanism in connections involving concrete filled steel columns under shear forces

  • De Nardin, Silvana;El Debs, Ana Lucia H.C.
    • Steel and Composite Structures
    • /
    • 제28권4호
    • /
    • pp.449-460
    • /
    • 2018
  • This paper reports the experimental results of three through bolt beam-column connections under pure shear forces using modified push-out tests. The investigated specimens include extended end-plates and six through-bolts connecting square concrete-filled steel tubular column (S-CFST) to steel beams. The main goal of this study is to investigate if and how the mechanical shear connectors, such as steel angles and stud bolts, contribute to the shear transfer mechanisms in the steel-concrete interface of the composite column. The contribution of shear studs and steel angles to improve the shear resistance of steel-concrete interface in through-bolt connections was investigated using tests. The results showed that their contribution is not significant when the beam-column connection is included in the push-out tests. The specimens failed by pure shear of the long bolts, and the ultimate load can be predicted using the shear resistance of the bolts under shear forces. The predicted values of load allowed obtaining a good agreement with the tests results.

DDM Rotordynamic Design Sensitivity Analysis of an APU Turbogenerator Having a Spline Shaft Connection

  • Lee, An-Sung;Ha, Jin-Woong
    • Journal of Mechanical Science and Technology
    • /
    • 제17권1호
    • /
    • pp.57-63
    • /
    • 2003
  • An eigenvalue design sensitivity formulation of a general nonsymmetric-matrix rotor-bearing system is devised. using the DDM (direct differential method). Then, investigations on the design sensitivities of critical speeds are carried out for an APU turbogenerator with a spline shaft connection. Results show that the dependence of the rate of change of the critical speed on the stiffness changes of bearing models of spline shaft connection points is negligible, and thereby their modeling uncertainty does not present any problem. And the passing critical speeds up to the 4th critical speed are not sensitive to the design stiffness coefficients of four main bearings. Further, the dependence of the rate of change of the critical speed on the shaft-element length changes shows quantitatively that the spline shaft has some limited influence on the 4th critical speed but no influence on the 1st to 3rd critical speeds. With no adverse effect from the spline shaft, the APU system achieves a critical speed separation margin of more than 40% at a rated speed of 60,000 rpm.

유한요소해석 기반의 전동 킥보드 연결부 형상에 따른 구조적 안전성 분석 (Structural Safety Analysis of Electric Kickboard According to Shape of Connection Parts Using Finite Element Analysis)

  • 김민규;김정진
    • 한국기계가공학회지
    • /
    • 제20권12호
    • /
    • pp.65-70
    • /
    • 2021
  • Electric kickboards are inviting attention as next-generation transportation systems with their number of users increasing rapidly every year. However, the number of related accidents similarly increases with the increase in the number of users. The purpose of this study is to analyze the structural safety of electric kickboards according to the shape of the connection parts. For this purpose, four different shapes of the connection parts, i.e., cube, cylinder, toroid, and divided cube were selected. Subsequently, the safety was analyzed based on the finite element (FE) analysis under the front collision scenario. The results showed that the shape of the divided cube induced the lowest von Mises stress and the highest safety factor amongst the four models. Moreover, only the shape showed a safety factor higher than 1. However, the shape of the cylinder exhibited the lowest structural vulnerability. These results demonstrate the importance of the shape of the connection part in maintaining the overall safety of an electric kickboard.

Analysis of Mechanical Properties in Steel Frame with Ductile Connections

  • Han, Minglan;Wang, Shuai;Wang, Yan
    • 국제강구조저널
    • /
    • 제18권4호
    • /
    • pp.1464-1469
    • /
    • 2018
  • Steel frames with ductile connections have good seismic performance under strong earthquake, they are now popular for high seismic design. In order to simplify the process of numerical analysis of the steel frames with ductile connections, simplified connection models are introduced, two types of springs are placed in the simplified connection model, which can simulate deformation of the panel zone and members. 6-story-3-bay steel frames with ductile connections are simplified and carried out modal analysis, fundamental periods of the frames predicted by finite-element analysis for simplified steel frame models were compared to the results for actual frame models. 2-story steel frame with reduced beam section connections is simplified and carried out pseudo-static analysis, hysteretic curves and skeleton curves of the frame obtained by finite-element analysis for simplified steel frame model are compared to test results. The comparison show that the difference between them is small, it is reliable and effective to predict mechanical properties of the steel frame with ductile connection by finite-element analysis of simplified steel frame model.

변단면 전조 가공 철근이음 연결방법의 성능 평가 (Mechanical Performance Evaluation of Rolling Thread Steel Rebar Connection with Taper type Coupler)

  • 정진환;김인태;김태진;이명진;안진희
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제19권2호
    • /
    • pp.40-51
    • /
    • 2015
  • 콘크리트 구조물에서는 인장응력에 대한 저항과 콘크리트내의 하중전달을 위한 철근이음이 고려되어야 한다. 현재 사용되고 있는 철근의 이음방법으로는 전통적으로 사용되는 겹침이음과 함께 채움금속이음을 갖는 슬리브이음과 전조 평행나사 이음과 같은 기계적 철근연결방법 등이 사용되고 있다. 본 연구는 기존에 사용되고 있는 기계적 철근 이음의 시공성과 구조적 성능을 개선하기 위하여 전조 변단면 철근이음을 제안하고 이를 적용한 철근의 구조성능과 파괴거동을 평가하기 위하여 철근연결 종류 및 체결 특성을 고려한 인장강도 실험과 휨하중 실험을 실시하였다. 이를 통하여 제안된 전조 변단면 이음을 적용한 철근의 인장강도 및 휨성능을 비교 평가하였다. 본 연구결과 전조변단면 이음을 적용한 철근이 이음이 없는 철근과 비교하여 동일한 구조성능을 가지는 것으로 나타나 철근콘크리트 구조물의 철근 이음을 위하여 사용할 수 있을 것이다.

Anchor bracket 체결 볼트에 대한 절단 강도 해석 (Breaking Strength Analysis for Bolt Connection of Anchor Bracket)

  • 이봉주;양헌석;오형식
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.55-60
    • /
    • 2011
  • For the bolster type bogie, bolster anchor body connections are proviede to transmit the longitudinal loads for traction or braking between the carbody and the truck. The bolster anchor body connection is generally composed of anchor rod bracket, anchor rod and its fastening devices. The bolster anchor body connection shall be basically capable of withstanding a longitudinal load resulting from excessive braking case or impact. Additionally the north America standard requires that the anchor rod bracket shall be frangible, I.e. the anchor rod bracket shall fail and fall away under load before the carbody structure is damaged since to protect the cabody structure in the event of unexpected accident. This paper describes the shear connection design using the optimized mechanical fasteners in the bolster anchor body connection to satisfy these Northe America requirements.

  • PDF

FRP 모듈형 박스 부재의 연결 시스템에 관한 실험적 연구 (An Experimental Study on Connection System of FRP Modular Box Member)

  • 곽계환;장화섭;양동운;김호선
    • 한국농공학회논문집
    • /
    • 제51권4호
    • /
    • pp.29-36
    • /
    • 2009
  • This is a basic experimental study to apply FRP modular box member to a variety of construction structures exposed to flexural strength, such as a slab and a girder. Applying FRP modular box member to a real structure requires a large section. FRP box member was made into modular systems. Tests were conducted under various conditions in order to analyze jointing performance of the developed FRP modular box member as a large section. For the methods of jointing FRP modular box member, synthetic resins connection, mechanical connection, and a combination of both were used to test both length and breadth connection. As a result of the test, using urethane + two bolts + sheets was the most efficient method of connecting FRP modular box member. It is expected that the proposed joint system in this study will contribute to the increase of failure load and synthesis behavior of FRP modular box member.

휴먼 에러 방지용 배선 안내 시스템 개발 (A Human Error-Free Wiring Guide System)

  • 이현찬;김주한;김진성;정연욱
    • 한국CDE학회논문집
    • /
    • 제22권2호
    • /
    • pp.181-189
    • /
    • 2017
  • In this paper, we develop a human error-free wire connection guide system. The only related work is Japanese patent by Hitachi. The patent is guiding the wire connection using PC server. And no implementation details have been reported publicly. We propose a new method based on smart mobile devices. The proposed methods are registered as two Korean patents. We implement a prototype wire connection guide system to verify the patents. Through human experiments, we verify the system can reduce the human error more than 90% and speed up the connection process more than twice faster than working without the system. To be used in the industrial fields, the prototype system needs more product packaging works.

Analytical study of slant end-plate connection subjected to elevated temperatures

  • Zahmatkesh, F.;Osman, M.H.;Talebi, E.;Kueh, A.B.H.
    • Steel and Composite Structures
    • /
    • 제17권1호
    • /
    • pp.47-67
    • /
    • 2014
  • Due to thermal expansion, the structural behaviour of beams in steel structures subjected to temperature increase will be affected. This may result in the failure of the structural members or connection due to extra internal force in the beam induced by the thermal increase. A method to release some of the thermally generated internal force in the members is to allow for some movements at the end supports of the member. This can be achieved by making the plane of the end-plate of the connection slanted instead of vertical as in conventional design. The present paper discusses the mechanical behaviour of beams with bolted slant end-plate connection under symmetrical gravity loads, subjected to temperature increase. Analyses have been carried out to investigate the reduction in internal force with various angles of slanting, friction factor at the surface of the connection, and allowable temperature increase in the beam. The main conclusion is that higher thermal increase is tolerable when slanting connection is used, which means the risk of failure of structures can be reduced.

분전반 내 차단기의 접속불량에 의한 이상발열에 관한 연구 (A Study on the Abnormal Heating of Circuit Breaker in Panel Board by Poor Connection)

  • 김향곤;김동우;최효상;최용성;최충석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 춘계학술대회 논문집 센서 박막재료연구회 및 광주 전남지부
    • /
    • pp.10-14
    • /
    • 2008
  • In this paper, abnormal heating of circuit breaker in panel board by poor connection was studied. Firstly, calculation method of contact resistance shown in IEC 60943 was examined. Secondly, concerning abnormal heating of circuit breaker in panel board, field measurements were performed. Field measurements showed that locally abnormal heating by poor connection could be detected, therefore, in that case, immediate action was needed. Finally, experiments regarding abnormal heating between terminal of circuit breaker and electric wire were conducted. The results showed that abnormal heating above $180^{\circ}C$ was measured. Also, in the results of analysis of electrical waveforms according to load current, voltage drop occurred around poor connection, and the oxide was generated according to mechanical vibration. In order to prevent electrical disaster caused by poor connection, adequate torque should be applied to electrical connection, and periodic check-ups are needed.

  • PDF