• Title/Summary/Keyword: measuring volume

Search Result 791, Processing Time 0.03 seconds

Tomographic reconstruction of Asymmetric Spray by Direct Sampling Method (직접샘플링에 의한 비대칭 분무의 토모그래피 재구성)

  • Lee, C.H.;Won, J.C.
    • Journal of ILASS-Korea
    • /
    • v.7 no.4
    • /
    • pp.9-15
    • /
    • 2002
  • Convolution Fourier transformation tomographically reconstructs the spatially resolved spray injection rate from direct measuring cells. Asymmetric sprays generated from a twin-hole air shroud injector are tested with 12 equiangular projections of measurements. For each projection angle, line of sight integrated injection rate was measured at 35 positions with equal spacing measuring cells of 3 mm in width, 100 mm in length, 55 mm in depth and 0.5 mm thickness of separating wall. Interpolated data between the projection angles effectively increase the number of projections, which significantly enhances the signal-to-noise level in the reconstructed data. This modified convolution Fourier transformation scheme predicts well the structure of asymmetric sprays. Comparative study has been made between sprays with and without air shrouding. Tomograhpic reconstruction of injection rate from direct measuring cells obtained can be used to estimate the accuracy of volume fraction of spray from the LDPA tomographic reconstruction.

  • PDF

Improvement of Signal Transmission Method of Ship's Engine Performance Analyzer(SEPA) using PLM (전력선 모뎀을 이용한 선박엔진 성능분석기의 신호전달방식의 개선)

  • Kim, Kun-Woo;Yang, Hyun-Suk;Lim, Hyun-Jung;Choi, Jun-Gil;Lee, Sung-Geun;Kim, Yoon-Sik
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.53-54
    • /
    • 2005
  • This paper describes that send some signal from encoder attached to crankshaft of marine-engine to measuring instrument using power line modem(PLM) and display cylinder pressure, rpm and etc. on LCD. Conventional method that sends signal along the long signal line has some inconvenience from too long signal line length caused by huge volume of ship's engine. Power line modem can have short signal line from outlets to measuring instrument. Because it use exist power line for send signals, so it have low installation cost and could have good merits in job sites. Through this experiment, pressure in cylinder, engine rpm and etc. signals through PLM are well recognized at measuring instrument.

  • PDF

Effect of Nano Filler on the Electrical Properties of Epoxy Composite (에폭시 복합재료의 전기적 특성에 미치는 나노 충진제의 영향)

  • Kim, Joung-Sik;Choi, Hyun-Min;Park, Hee-Doo;Ryu, Boo-Hyung;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.46-46
    • /
    • 2010
  • In this paper, we studied the volume resistivity and the electrical conductivity properties of nano composites to investigate the electrical properties of epoxy composites added nano MgO. The specimens were produced by classifying to 1.0, 3.0, 5.0, 10[wt%] and virgin specimen according to the addition amount of MgO. We measured the volume resistivity of nano filler using the High Resistance Meter(4329A) at the measuring temperature changed to 25, 50, 80, 100, and [$120^{\circ}C$]. As the result, it is confirmed that the volume resistivity was the highest stability and volume resistivity value is $2.6{\times}10^{17}\;[\Omega{\cdot}cm]$ at 3.0[wt%]. And it is confirmed that the electrical conductivity property is sharply increased at low electric filed region and the conductivity current density is rapidly increased at high electric filed region.

  • PDF

A study on the method of measurement of the standing-tree volume -Particularly concerning the method of measurement of the timber volume (입목재적(立木材積) 측정법(測定法)에 관(關)한 연구(硏究) -용재수목(用材樹木)의 재적측정법(材積測定法)을 중심으로)

  • Lee, Kwang Nam
    • Journal of Korean Society of Forest Science
    • /
    • v.3 no.1
    • /
    • pp.28-31
    • /
    • 1963
  • Recognizing shortcomings and unreasonable points of the usual methods of measurement of the standing-tree volume, author contrived measurement formula of standing-tree volume which is based on stem-curve equation, $y^2=2px$, resulted from the analysises and experiments on stem-curve by differentiation & integration. The results of this study are as follows ; (1) The following is the formula. $V=1/2g_{1.2}$(h+1.2) V=volume of tree $g_{1.2}$ = sectional area at breast heigh h = height of tree (2) So plain is the form of this formula that this formula is more convenient than usual formulas in measuring. (3) The percentage error of this formula is negative and it is remarkably superior to usual formulas except Pressler's formula, in other words, the higher the tree that is measured is, the more inaccurate become pressler's formula, and the percentage error of the breast-height form factor method is direct proportion to the grossness of the tree that is measured, but the higher the tree that is measured, the lower become percentage error of this formula in geometrical progression.

  • PDF

Pressure-volume-temperature gauging method experiment using liquid nitrogen under microgravity condition of parabolic flight

  • Seo, Mansu;Park, Hana;Yoo, DonGyu;Jung, Youngsuk;Jeong, Sangkwon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.2
    • /
    • pp.64-69
    • /
    • 2014
  • Measuring an exact amount of remaining cryogenic liquid propellant under microgravity condition is one of the important issues of rocket vehicle. A Pressure-Volume-Temperature (PVT) gauging method is attractive due to its minimal additional hardware and simple gauging process. In this paper, PVT gauging method using liquid nitrogen is investigated under microgravity condition with parabolic flight. A 9.2 litre metal cryogenic liquid storage tank containing approximately 30% of liquid nitrogen is pressurized by ambient temperature helium gas. During microgravity condition, the inside of the liquid tank becomes near-isothermal condition within 1 K difference indicated by 6 silicon diode sensors vertically distributed in the middle of the liquid tank. Helium injection with higher mass flow rate after 10 seconds of the waiting time results in successful measurements of helium partial pressure in the tank. Average liquid volume measurement error is within 11% of the whole liquid tank volume and standard deviation of errors is 11.9. As a result, the applicability of PVT gauging method to liquid propellant stored in space is proven with good measurement accuracy.

A Study on the Electrical Properties of Transformer Oils for Large Power (대용량 변압기유의 전기적특성에 관한 연구)

  • 이용우;김왕곤;홍진웅
    • Journal of the Korean Society of Safety
    • /
    • v.11 no.3
    • /
    • pp.81-88
    • /
    • 1996
  • In order to investigate the electrical properties of transformer oils for large power, the characteristics of AC and Impulse breakdown in gap length of 1.0~2.5mm and that of volume resistivity were researched in temperature range of 20~$100^{\circ}C$. An geometrical capacitance of electrode with coaxial cylindrical shape for measuring the volume resistivity was 16pF, and highmegohm meter with model no. VMG-1000 was used, and also the applied voltage were DC 100, 250 and 500V. In the dependance of breakdown characteristics due to electrode gap length, it was confirmed that breakdown voltage was nearly uniform by volume effect according to the increase of gap. In the characteristics for AC breakdown, the dielectric strength was increased to $90^{\circ}C$ but decreased over $90^{\circ}C$, and also in case of impulse breakdown, it was increased to 7$0^{\circ}C$ and at dated $70^{\circ}C$ over in temperature range. The calculated mobility of oils in the characteristics for impulse breakdown were about $10^{-5}$~$10^{-4}cm^2/V{\cdot}S$, and the value of volume resistivity was almost invariable in low temperature range, regardless of voltage by the stable thermal properties, and it indicated a peak at $50^{\circ}C$ and had a sudden change to decrease over that temperature, and also the value of volume resistivity in 250V/mm at $80^{\circ}C$ is suitable for the International electrical standards, it was confirmed.

  • PDF

Fashion Brand Sales Forecasting Analysis Using ARDL Time Series Model -Focusing on Brand and Advertising Endorser's Web Search Volume, Information Amount, and Brand Promotion- (ARDL 시계열 모형을 활용한 패션 브랜드의 매출 예측 분석 -패션 브랜드와 광고모델의 웹 검색량, 정보량, 가격할인 프로모션을 중심으로-)

  • Seo, Jooyeon;Kim, Hyojung;Park, Minjung
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.46 no.5
    • /
    • pp.868-889
    • /
    • 2022
  • Fashion companies are using a big data approach as a key strategic analysis to predict and forecast sales. This study investigated the effectiveness of the past sales, web search volume, information amount, brand promotion, and the advertising endorser on the sales forecasting model. The study conducted the autoregressive distributed lag (ARDL) time series model using the internal and external social big data of a national fashion brand. Results indicated that the brand's past sales, search volume, promotion, and amount of advertising endorser information amount significantly affected the sales forecast, whereas the brand's advertising endorser search volume and information amount did not significantly influence the sales forecast. Moreover, the brand's promotion had the highest correlation with sales forecasting. This study adds to information-searching behavior theory by measuring consumers' brand involvement. Last, this study provides digital marketers with implications for developing profitable marketing strategies on the basis of consumers' interest in the brand and advertising endorser.

An Experiment on Volume Data Compression and Visualization using Wavelet Transform (웨이블릿 변환을 이용한 볼륨데이타의 압축 및 가시화 실험)

  • 최임석;권오봉;송주환
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.9 no.6
    • /
    • pp.646-661
    • /
    • 2003
  • It is not easy that we visualize the large volume data stored in the every client computers of the web environment. One solution is as follows. First we compress volume data, second store that in the database server, third transfer that to client computer, fourth visualize that with direct-volume-rendering in the client computer. In this case, we usually use wavelet transform for compressing large data. This paper reports the experiments for acquiring the wavelet bases and the compression ratios fit for the above processing paradigm. In this experiments, we compress the volume data Engine, CThead, Bentum into 50%, 10%, 5%, 1%, 0.1%, 0.03% of the total data respectively using Harr, Daubechies4, Daubechies12 and Daubechies20 wavelets, then visualize that with direct-volume-rendering, afterwards evaluate the images with eyes and image comparison metrics. When compression ratio being low the performance of Harr wavelet is better than the performance of the other wavelets, when compression ratio being high the performance of Daubechies4 and Daubechies12 is better than the performance of the other wavelets. When measuring with eyes the good compression ratio is about 1% of all the data, when measuring with image comparison metrics, the good compression ratio is about 5-10% of all the data.

Micro-particles in a Nanoliter Droplet Dispensed by a Pneumatic Dispensing System and Its Measurement (공압 디스펜싱 시스템을 이용한 나노리터 액적에 포함된 미세 입자의 분주 및 측정)

  • Lee, Sang-Min;Kim, Joon-Won
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.8
    • /
    • pp.913-919
    • /
    • 2012
  • This paper presents results for dispensing and measuring micro-particles using a pneumatic dispensing system. Particle-suspended liquid droplets were dispensed and analyzed quantitatively at various particle concentrations and applied pressures. By using a developed experimental setup, the number of particles and the particle volume ratio in sequentially dispensed droplets were measured. Hydrophilic and hydrophobic surfaces were tested to find a suitable surface for counting the number of particle. It was confirmed that the dispensed particles concentrated into the center of the droplet on the smooth CD surface after evaporation of liquid. As the applied positive pressure increased, the number of particles per droplet increased consistently and the volume fraction of particles remained constant.