• 제목/요약/키워드: measuring volume

검색결과 793건 처리시간 0.029초

디젤 인젝터의 분사율 특성에 관한 연구 (A Study on Injection Rate Characteristics of a Diesel Injector)

  • 정재우;김남호;임창현;김덕진
    • 한국분무공학회지
    • /
    • 제20권4호
    • /
    • pp.217-222
    • /
    • 2015
  • In this study, Injection rate tests of a Diesel common-rail injector have been performed with injection volume measurement type injection rate test system EMI21 for construction of injector model can be used in an engine calibration mean valued model. The measuring principle of the test system is based on measurement of dispalcement of a movable measurement piston by the volume of fluid released by the injector. From these injection rate test results, the characteristics on shape of instantaneous injection rate and injection fuel amount have been investigated and injection fuel amount calculation equation based on test results has been newly constructed. This equation is very simple and calculation error is less than 5% with test results for wide range injection pressure (200~1800 bar) and injection duration ($200{\sim}1800{\mu}s$) conditions. So, it is anticipated that newly constructed simple injection fuel amount model in this study can be efficiently used on engine calibration and control model.

홍삼 분말 첨가 식빵의 이화학적 및 관능적 특성 (The Physicochemical and Sensory Characteristics of Bread Added with Red Ginseng Powder)

  • 김나영;김성환
    • 동아시아식생활학회지
    • /
    • 제15권2호
    • /
    • pp.200-206
    • /
    • 2005
  • This study was conducted to investigate the quality characteristics of the bread with red ginseng powder(RG). Four different powder concentration levels of 0, 3, 6, and $9\%$ were added to flour to make the bread. The appearance, pH, water holding capacity, specific volume, color, texture, and sensory properties were analyzed. pH of bread with RG had no difference according to the content of the red ginseng powder. The specific volume of the bread containing $0,\;3,\;6\%$ were bigger than that of the bread with $RG-9\%$. The water holding capacity of the bread with $RG-9\%$ was the highest. As the amounts of RG increased, L-values of the bread crumb were decreased and a- and b-values were increased. As a result of texture measuring by texture analyzer, hardness and gumminess were not affected by the addition of RG. Also, springiness, cohesiveness, and chewiness were not significantly different among the control, $RG-3\%\;and\;RG-9\%$. In sensory evaluation, color, flavor, taste and overall acceptability in the bread with $RG-9\%$ were significantly lower than the control and the other groups. On the other hand, the best result for sensory characteristics showed when red ginseng powder at $3\%$ level was added to the bread.

  • PDF

불꽃원자 흡수 분광법의 Micro Sampling Technique 에 의한 미량 중금속의 분석에 관한 연구 (A Study on the Determination of Some Heavy Metals using Micro Sampling Technique in Flame Atomic Absorption Spectrophotometry)

  • 이원
    • 대한화학회지
    • /
    • 제29권3호
    • /
    • pp.220-225
    • /
    • 1985
  • 불꽃 원자 흡수 분광법의 Micro Sampling Technique을 이용하여 염의 농도가 높고, 양이 제한된 시료중에 미량으로 함유된 Cu, Zn 및 Fe의 분석을 시도하였다. 최적기간 및 분석조건을 조사한 결과 측정시간 0.3초, 시료부피 100${\mu}l$, 시료의 흡입속도 7.5ml/min, 연료와 산화기체의 혼합비 2.0 및 버어너 높이는 Cu일때 6.0mm, Zn 및 Fe는 8.0mm이었다. 이 방법을 일반적인 불꽃 방법과 비교하여 보면 시료의 전처리 과정이 필요없이 간단하고, 비교적 정밀성과 정확성이 있으며, 특히 100${\mu}l$정도로 양이 제한된 시료와 약 20% 정도로 염의 농도가 높은 시료의 경우도 버어너 틈새가 막히지 않고 안정한 불꽃에서 분석이 가능하였다.

  • PDF

풍력발전용 대형 복합재 회전날개의 구조시험 및 평가에 관한 연구 (Test and evaluation of a large scale composite rotor blade for wind turbine)

  • 공창덕;정종철;장병섭
    • 한국추진공학회지
    • /
    • 제5권1호
    • /
    • pp.76-81
    • /
    • 2001
  • A structural test of the wind turbine rotor blade is to evaluate the uncertainty of design due to selection of material, design concepts, production processes and so on, and their possible impacts on the structural integrity. In the full-scale static strength test, the measuring parameters are strain and displacements vs. loads, weight and the center of gravity. In order to simulate the aerodynamics load, the three-point loading method is applied. There is slight difference between the measured results and the predicted results for the reference fiber volume fraction of 60% . However, the agreement between the measured results and the predicted results with the actual fiber volume fraction of 52.5% is good. Even though a slightly non-linearity from 80% loading to 100% loading exists, a linear static solution is sufficient for the design purpose due to te small amount of non-linearity. Comparison between measured and predicted strain results at the maximum thickness positions of the blade profile for 0.236R(5.56m), 0.493R(11.59m) and 0.574R(13.43m), under 20%, 40%, 60%, 80% and 100% loadings for the upper part of the blade. The predicted values are in good agreement with the measured values.

  • PDF

광용적맥파(PPG)를 이용한 호흡수 측정에 있어서 동잡음을 이용한 정확도 향상 (Accuracy improvement of respiration rate based on photo-plethysmography by enhancing motion artifact)

  • 허영정;윤길원
    • 센서학회지
    • /
    • 제17권6호
    • /
    • pp.447-453
    • /
    • 2008
  • Respiration rate is one of the important vital signs. Photo-plethysmography (PPG) measurement especially on a finger has been widely used in pulse oximetry and also used in estimating respiration rate. It is well known that PPG contains respiration-induced intensity variation (RIIV) signal. However, the accuracy of finger PPG method has been controversial. We introduced a new technique of enhancing motion artifact by respiration. This was achieved simply by measuring PPG on the thorax. We examined the accuracy of these two PPG methods by comparing with two existing methods based on thoracic volume and nostril temperature changes. PPG sensing on finger tip, which is the most common site of measurement, produced 6.1 % error. On the other hand, our method of PPG sensing on the thorax achieved 0.4 % error which was a significant improvement. Finger PPG is sensitive to motion artifact and it is difficult to recover fully small respiratory signal buried in waveform dominated by absorption due to blood volume changes. Thorax PPG is poor to represent blood volumes changes since it contains substantial motion artifact due to respiration. Ironically, this inferior quality ensures higher accuracy in terms of respiration measurement. Extreme low-cost and small-sized LED/silicon detector and non-constrained reflection measurement provide a great candidate for respiration estimation in ubiquitous or personal health monitoring.

지르칼로이-4 튜브 및 지지부의 접촉조건과 미끄럼 상태의 천이 (Contact Condition of Zircaloy-4 Tube and Support and Transition of Slip Regime)

  • 김형규;강흥석;윤경호;송기남
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2001년도 제33회 춘계학술대회 개최
    • /
    • pp.81-88
    • /
    • 2001
  • To study the influence of the shape of contacting bodies (especially the end profile) on slip regime, wear test is conducted in the case of the contact between tube and support. Two different end profiles of the support are used such as truncated wedge and rounded punch. During the test, 10, 30 and 50 N are applied as normal force and slip displacement varies between 10-200 $\mu\textrm{m}$. The tube and the support specimens are made of Zircaloy-4 and a specially designed wear tester is used. Tests are carried out in air at room temperature. Wear on the tube is examined by measuring microscope. Partial and gross slip regimes are classified from the observed wear shape. Surface roughness tester is also used to measure the wear depth and contour, from which wear volume is evaluated. The transition from partial to gross slip is also investigated by investigating the considerable increase of wear volume. From the result, the boundary between the partial and the gross slip is newly determined in the conventional fretting map for the present specific contact configuration. Since the transition is related with the amount of energy dissipation from the contact surface so is wear, it is regarded that wear can be restrained by designing a proper shape of support.

  • PDF

다중 측정 좌표계를 이용한 로봇 캘리브레이션 방법 연구 (Study on Robot Calibration Using Multi-measurement Coordinate System)

  • 임생기;김정태;범진환;최재성
    • 한국정밀공학회지
    • /
    • 제16권3호통권96호
    • /
    • pp.164-173
    • /
    • 1999
  • Robot calibration needs accurate measurements of robot end-effector position at a number of different robot configurations. One of the efficient ways of the measurement is "Touching on Jig" method suggested in [7], which utilizes a touch sensor and a fixture consisting of various sizes of blocks. By moving the end-effector to touch the surface of a block whose position relative to the other is known, the end-effector position relative to the fixture coordinate system can be obtained at the instant of touching. However, the global size of fixture is too small to cover the various configurations of the robot. Because of the manufacturing difficulties, the fixture cannot be manufactured large enough for well distributed position measurement. It results in the improvement of robot accuracy only in the limited space near to the fixture rather than over the whole space of the robot working volume. The paper proposes a method to resolve the above problem by measuring the end-effector positions with respect to several different coordinate system using the same measurement devices. It is found that the proposed method leads the improvements of robot position accuracy over the large space of working volume. The experimental studies are performed to show the validity of the method and their results are discussed.

  • PDF

Spontaneously Regressed Rathke's Cleft Cyst

  • Lee, Chaejin;Park, Seong-Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • 제62권6호
    • /
    • pp.723-726
    • /
    • 2019
  • We report two rare cases of spontaneously regressed Rathke's cleft cyst (RCC). A 52-year-old woman presented with headache. A pituitary hormone study was normal. Brain magnetic resonance imaging (MRI) showed a $0.45-cm^3$ cystic sellar lesion. The cyst was hyperintense on T1-weighed imaging and hypointense on T2-weighted imaging without rim enhancement, comparable to a RCC. Six months later, brain MRI showed no change in the cyst size. Without any medical treatments, brain MRI 1 year later revealed a spontaneous decrease in cyst volume to $0.05cm^3$. A 34-year-old woman presented with headache and galactorrhea lasting 1 week. At the time of the visit, the patient's headache had disappeared. Her initial serum prolactin level was 81.1 ng/mL, and after 1 week without the cold medicine, the serum prolactin level normalized to 11.28 ng/mL. Brain MRI showed a RCC measuring $0.71cm^3$. Without further treatments, brain computed tomography 6 months later showed a spontaneous decrease in cyst volume to $0.07cm^3$. Another 6 months later, brain MRI revealed that the cyst had remained the same size. Neither patient experienced neurological symptoms, such as headache or visual disturbance, during the period of cyst reduction. The RCCs in both patients underwent spontaneous regression without any medical treatment during a period of 6 months to 1 year. Although spontaneous regression of a RCC is rare, it is still possible and a sufficient follow-up period should be considered.

Generation of sub-micron (nano) bubbles and characterization of their fundamental properties

  • Kim, Sangbeom;Kim, Hyoungjun;Han, Mooyoung;Kim, Tschungil
    • Environmental Engineering Research
    • /
    • 제24권3호
    • /
    • pp.382-388
    • /
    • 2019
  • Although nanobubbles attract significant attention, their characteristics and applications have not been thoroughly defined. There are diverse opinions about the definition of nanobubbles and controversy regarding methods that verify their characteristics. This study defines nanobubbles as having a size less than $1{\mu}m$. The generation of these sub-micron (nano) bubbles may be verified by induced coalescence or light scattering. The size of a sub-micron (nano) bubbles may be measured by optical, and confocal laser scanning microscopy. Also, the size may be estimated by the relationship of bubble size with the dissolved oxygen concentration. However, further research is required to accurately define the average bubble size. The zeta potential of sub-micron (nano) bubbles decreases as pH increases, and this trend is consistent for micron bubbles. When the bubble size is reduced to about 700-900 nm, they become stationary in water and lose buoyancy. This characteristic means that measuring the concentration of sub-micron (nano) bubbles by volume may be possible by irradiating them with ultrasonic waves, causing them to merge into micron bubbles. As mass transfer is a function of surface area and rising velocity, this strongly indicates that the application of sub-micron (nano) bubbles may significantly increase mass transfer rates in advanced oxidation and aeration processes.

LoRa를 이용한 노지 작물 관리 시스템 (Smart Outdoor Cultivation System using LoRa)

  • 염성관;한세영;이희권;신광성
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2021년도 춘계학술대회
    • /
    • pp.265-266
    • /
    • 2021
  • 본 논문은 사물인터넷을 이용한 노지 농작물 재배 시스템 구축 사례를 설명하고 노지 작물 재배 시스템에서의 환경 변수를 정의하였다. 다양한 센서을 통해서 토양의 온도, 함수율, 전기전도도, 산성도를 측정하여 LoRa 통신 모듈을 이용하여 서버로 정보를 전달하고, 서버는 이 데이터를 바탕으로 시비량 및 관수량을 제어한다. 노지 농작물 재배에 적합한 통신 방식인 LoRa 기술을 이용하여 넓은 노지를 관리하고 생산량 및 판매실적까지 관리하는 시스템을 개발하였다.

  • PDF