• Title/Summary/Keyword: measuring volume

Search Result 793, Processing Time 0.028 seconds

Degree of enophthalmos according to the extent of orbital wall fracture and volume of herniated orbital tissue (안와벽 골절 면적과 이탈된 안와내 조직의 부피에 따른 안구함몰 정도)

  • Jang, Hak-Sun;Leem, Dae-Ho;Baek, Jin-A;Shin, Hyo-Keun;Ko, Seung-O
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.37 no.3
    • /
    • pp.205-213
    • /
    • 2011
  • Introduction: The enlargement and deformation of the orbit give rise to a visible enophthalmos. As a consequence, a disturbance of eye motility together with double images is likely to occur. This study examined the degree of enophthalmos according to the extent of orbital wall fracture and volume of herniated orbital tissue in blowout fractures of the medial and inferior orbital wall. Materials and Methods: This study was performed on patients diagnosed with medial and inferior orbital wall fractures at the Department of Oral and maxillofacial surgery, Chonbuk National University Hospital from 2007 to 2009. The patients' age, gender, etiology of fracture and degree of enophthalmos were investigated. The changes in the degree of enophthalomos, diplopia and ocular motility restriction after operation were examined. Results: The degree of enophthalomos increased with increasing extent of orbital wall fracture and volume of herniated orbital tissue. Conclusion: Whether to perform the operation is decided after measuring the extent of the orbital wall fracture and volume of herniated orbital tissue using computed tomography (CT), time for the decision of operation can be shortened. This can cause a decrease in the complications of orbital wall fractures.

Evaluate the usefulness of Coincidence Summing Correction Factors for Cylinder and Extended Source Penelope Simulation (실린더 및 확장 소스 PENELOPE 시뮬레이션에 대한 동시합성보정 계수 유용성 평가)

  • Jang, Eun-Sung;Chang, Bo-Seok
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.821-831
    • /
    • 2021
  • In order to calibrate energy and efficiency using the PENELOPE Code, a PENELOPE simulation was performed using a volume source. Here, we want to verify peak efficiency and usefulness by performing simultaneous measurement and correction. calculate the coincident sum correction for all volumes, first subdivide the volumes of the cylinder and the four Marinelli beakers into three heights again. Therefore, the simultaneous measurement correction coefficient in three areas and the simultaneous measurement correction coefficient for the entire volume source are calculated as output. At low energies, the j value for each source volume (50-300 ml) is small and increases significantly in the high energy range. Simulation results showed good agreement within 2.5% for all source volumes except for 50 ml and 300 ml, which were up to 4%. This means that the correction for the simultaneous measurement effect during measurement is effective. In addition. Based on this, it can be confirmed that there is an advantage to improve the detection efficiency when measuring various sources and environmental samples.

Evaluation of Damaged Stand Volume in Burned Area of Mt. Weol-A using Remotely Sensed Data (위성자료를 이용한 산화지의 입목 손실량 평가)

  • Ma, Ho-Seop;Chung, Young-Gwan;Jung, Su-Young;Choi, Dong-Wook
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.2 no.2
    • /
    • pp.79-86
    • /
    • 1999
  • This study was carried out to estimate the area of damaged forest and the volume of stand tree in burned area, Mt. Weol-A in eastern Chinju, Korea using digital maps derived from supervised classification of Landsat thematic mapper(TM) imagery as reference data. Criterion laser estimator and WinDENDRO$^{tm}$(v. 6.3b) system as a computer-aided tree ring measuring system were used to measure a volume and age of sampled tree. The sample site had been chosen in unburned areas having the same terrain condition and forest type of burned areas. The tree age, diameter at breast height, tree height and volume of the sample tree selected from sample site in unburned area were 27years, 20.9cm, 9.7m and $0.1396m^3$ respectively. Total stand volume of sample site was estimated $2.9316m^3$/0.04ha, Damaged stand volume evaluated to about $16,007m^3$ in the burned area of 218.4ha.

  • PDF

Feature Recognition for Digitizing Path Generation in Reverse Engineering (역공학에서 측정경로생성을 위한 특징형상 인식)

  • Kim Seung Hyun;Kim Jae Hyun;Park Jung Whan;Ko Tae Jo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.12
    • /
    • pp.100-108
    • /
    • 2004
  • In reverse engineering, data acquisition methodology can generally be categorized into contacting and non-contacting types. Recently, researches on hybrid or sensor fusion of the two types have been increasing. In addition, efficient construction of a geometric model from the measurement data is required, where considerable amount of user interaction to classify and localize regions of interest is inevitable. Our research focuses on the classification of each bounded region into a pre-defined feature shape fer a hybrid measuring scheme, where the overall procedures are described as fellows. Firstly, the physical model is digitized by a non-contacting laser scanner which rapidly provides cloud-of-points data. Secondly, the overall digitized data are approximated to a z-map model. Each bounding curve of a region of interest (featured area) can be 1.aced out based on our previous research. Then each confined area is systematically classified into one of the pre-defined feature types such as floor, wall, strip or volume, followed by a more accurate measuring step via a contacting probe. Assigned to each feature is a specific digitizing path topology which may reflect its own geometric character. The research can play an important role in minimizing user interaction at the stage of digitizing path planning.

A Numerical Study on Natural Convection Between Skin and Fabrics (Phoenics를 이용한 옷감의 종류 및 두께의 변화에 따른 열전달 특성의 수치 해석적 연구)

  • 홍지명
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.19 no.1
    • /
    • pp.142-148
    • /
    • 1995
  • In this study, FVM (Finite Volume Method) which is one of the 2-dimensional numerical approach has been conducted to anticipate the temperature distribution between skin and clothes by the change of air temperature and fabric characteristics including fabric thickness. Several experimental works have been done to understand the thermal insulation effect (If fabrics on a human body by measuring the averaged temperature in the air layer between skin and clothes or by measuring the thermal resistance of fabrics. However, the formal method is inconvenient to measure the temperature distribution in the air layer to evaluate the insulation rate of the clothes on the skin because the real size of the clearance between skin and the clothes is too small to place the temperature sensor, and in the Tatter method the relationship between human body and the fabrics are ignored. However, the numerical method will be very effective and economical way to evaluate the insulation efficiency of clothes when the computational result is in the reliable range. As the result of this study, the temperature change in the sir layer between skin and clothes was linear to the fabric thickness and this result coincides with many previous experimental results. Moreover, it is possible to predict the optimum fabric thickness for the best thermal insulation in the air layer between skin and clothes.

  • PDF

Optimum Electrode Selection for Measuring Abdominal Pressure using Bio-Impedance Method (생체 임피던스 방법을 이용하여 복압을 측정하기 위한 최적 전극위치 선정)

  • Kim, Keo-Sik;Lee, Sang-Ok;Seo, Jeong-Hwan;Kim, Kyeong-Seop;Song, Chul-Gyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.7
    • /
    • pp.1339-1342
    • /
    • 2007
  • In this study, we determined the optimum electrode pair for measuring the abdominal pressure using bio-impedance method and compared with conventional methods. Because impedance changes differ from a weight, a height, contractile force, volume of muscle and blood other or whatever of individuals, it was quantified using values of impedance change, correlation coefficient and SNR. Our results showed the optimum electrode pair (1, 9) which could detect impedance changes due to an increase of the intensity of the abdominal pressure. The correlation coefficient and quadratic function between the RMS values of EMG and the impedance changes were 0.87 and $y=0.0014x^2+0.0620x+0.6958$, respectively. It demonstrated that the abdominal pressure could be measured noninvasively and simply using bio-impedance method. We propose that this optimum electrode configuration would be useful for future studies involving the convenient measurement of abdominal pressure by ambulatory urodynamics monitoring study.

Study on design and measurement of aspheric (비구면의 설계와 측정)

  • Park, Dong Hwa
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.2
    • /
    • pp.133-138
    • /
    • 2005
  • As Aspheric lenses have producted to development for disadvantage of spherical lenses, the purpose of use on aspheric lenses is in improvement of the imaging quality and decrement of the number of lenses used, they are used for lessen the mass and volume in optical science. The skills to produce optical data and the aspheric are seen as high technology today. The optical science which is composed of aspheric provides broadening view of things and high efficiency. In addition, it provides many advantages such as providing image and reducing the weight. Now, I study with techniques of processing and measuring aspheric to satisfy the necessity of increasing in aspheric data. Furthermore. I emphasize that the techniques of producing, measuring, and evaluating in the aspheric lenses have constantly developing today.

  • PDF

New uroflowmetry technique measuring hydraulic pressure for prostate diagnostics (전립선 진단을 위한 수압 측정 방식의 새로운 요 유량 계측기법)

  • Kim, Kyung-Ah;Choi, Sung-Soo;Cha, Eun-Jong
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.179-186
    • /
    • 2007
  • Uroflowmetry is non-invasive and easily performed to diagnose benign prostate hypertrophy (BPH) frequent in aged men. Weight change during urination is usually measured to estimate the urinary flow rate by a load cell, but sensitive to any impacts against the bottom of the container, leading to unnecessary noise generation. Moreover, load cells are relatively expensive raising the production cost. The present study proposed a new technique, measuring hydraulic pressure on the bottom of the urine container to evaluate the urinary flow rate. Low cost pressure transducer enabled almost perfectly linear relationship between the urine volume and the hydraulic pressure. During both the simulated and human urination experiment, variance of the pressure signal was more than 50 % smaller than the weight signal acquired by a load cell, which demonstrated that the impact noise was decreased to a great degree by pressure compared to weight measurement.

Effects of carbon content and Titanium Addition on Damping Capacity in Fe-17wt%Mn Alloy (Fe-17wt%Mn 합금의 진동감쇠능에 미치는 탄소와 티타늄 첨가의 영향)

  • Baik, S.H.;Kim, J.C.;Jee, K.K.;Shin, M.C.;Choi, C.S.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.9 no.1
    • /
    • pp.53-61
    • /
    • 1996
  • Effects of carbon and Ti on damping capacity are investigated in an Fe-17%Mn alloy. The suppressive force of carbon against ${\gamma}{\rightarrow}{\varepsilon}$ transformation increases linearly with an increase in its content, lowering Ms temperature and volume fraction of ${\varepsilon}$ martensite. Carbon deteriorates damping capacity by reducing the interfacial area of damping sources and mobility of the boundaries contributing to anelastic deformation. The reduction in damping capacity is accelerated when carbon-containing alloy is aged at higher temperatures above room temperature. The effect of Ti on damping capacity is found to be benificial in carbon-containing alloy, which is attributed to the depletion of carbon solute due to the formation of TiC.

  • PDF

Void Fraction Measurement by the Improved Multi-Channel Impedance Void Meter (개량된 다채널 임피던스형 측정기에 의한 기포율의 측정)

  • Song, Cheol-Hwa;Jeong, Mun-Gi
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.1
    • /
    • pp.384-398
    • /
    • 1996
  • An improved multi-channel Impedance Void Meter (IVM) is developed to measure an area-averaged void fraction. It consists of a main sensor, a reference sensor and a signal processor. The sensor was designed to be flush-mounted to the inner wall of the test section to avoid the flow disturbances. Guard electrodes are used to obtain evenly distributed electrical field in a measuring volume. A reference sensor is also installed to eliminate the drift in void signal caused by the changes in electrical properties of working fluid. The signal processor with three channels is specially designed so as to minimize the inherent error due to the phase difference between channels. As an example of applications, the mean and fluctuating components of void fraction are measured for bubbly and slug flow regime, and it is shown that IVM has good dynamic resolution which is required to investigate the structural developments of bubbly flow and the propagation of void waves in a flow channel.