Analysis and the measurement of the variation of electric field in air and oil using optical measuring system (광계측 시스템을 이용한 유.기중 코로나 방전의 전계변화 측정 및 비교분석)

  • Ma, Ji-Hoon;Ryu, Cheol-Hwi;Kang, Won-Jong;Chang, Yong-Moo;Koo, Ja_Yoon
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1668-1670
    • /
    • 2002
  • Since more than two decades, the conventional PD detecting systems have been employed in order to detect the partial discharges occurring inside the HV power apparatus for their diagnosis by use of different type of detection such as acoustic and UHF detection method. Regardless of their wide on-site application, a certain number of technical inconveniences have been disclosed as follows : multistage amplification. large volume, susceptible to external noise and high price. In this respect, the optical measurement techniques are widely proposed in these days in this concerned field ascribed to the following advantages : immune to external EMI noise and broad band response of the Pockels cell covering from DC to GHz. However, the reliability of several proposed techniques enabling to measure the electric field inside the large high power apparatus has not yet been well approved In this work, an optical measuring system, based on the Pockels effect, has been developed for measuring the field variation due to the corona discharges occurring in air and in oil. This system consists of He-Ne laser, single mode optical fiber, multi mode optical fiber, polarizing film, Y-cut LiNbO3 cell, photo detector, digital oscilloscope and personal computer with GPIB. For this purpose, optical probe has been specially designed and realized and put into the needle-plane electrode. Afterward, same measurement is carried out in oil. We demonstrate the characteristic of the optical measuring system and the measurement results.

  • PDF

PDA based Bluetooth Wireless Radiation Counter (PDA기반의 블루투스 무선통신 방사선 측정 장치)

  • Im, Sang-Heui;Park, Dae-Sung;Jin, Gye-Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.2 no.1
    • /
    • pp.5-10
    • /
    • 2008
  • This study developed a PDA based wireless communication radiation measuring instrument using Bluetooth. The proposed system is composed of Student Radiation Monitor of Vernier using GM (Geiger Mueller) counter tube as a radiation measuring sensor, LabPro of Vernier as a module for data collection, Promi SD 101 of Initium, which can make Bluetooth communication up to 30 m, for wireless data transmission, and HP 5550 embedded with Pocket PC 2003 as OS for data storage and display. Because GM counter tube is used as a radiation measuring sensor, the system cannot measure radiation energy but measures count volume and count rate. When the result of natural radiation measuring by the PDA based system was compared with that by a PC based system, it was found that the proposed system transmits and receives data without distortion.

  • PDF

Evaluation on Protrusion of the Imaginary Prostate Volume Using Three-Dimensional Volume Rendering (3차원 볼륨 렌더링을 이용한 가상 돌출형 전립선 부피 평가)

  • Seoung, Youl-Hun;Joo, Yong-Hyun;Rhim, Jae-Dong;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.208-215
    • /
    • 2009
  • This study is to compare the accuracy of evaluation regarding the volume of the prostate, which three-dimensional volume rendering was produced the shape of protrusion, by measuring two kinds of craniocaudal length from the top of the protrusion and from the exclusion of the protrusion as the starting points. For the imaginary protrusion prostate models, total of 10 models were roughly made by using devils-tongue jelly and changing each of the 10 ml of capacity from 10 ml to 100 ml. For the protrusion prostate models aimed at estimating the real volume, through 64 cannel computed tomography (CT) and 3.0 tesla magnetic resonance image (MRI) were conducted by planimetry technique from three-dimensional volume rendering. And then we performed to evaluate on significance of these volumes by wilcoxon signed rank test. Also the obtained volumes data by ellipsoid volume formula were measured the volume of protrusion prostate models two times with each method using the two kinds of craniocaudal length from top of the protrusion and from exclusion of the protrusion as the starting points. Finally, the significance of differences using wilcoxon signed rank test was evaluated between the real volume by planimetry technique and the measured volume by ellipsoid volume formula from three-dimensional volume rendering. The average of the protrusion length on the models was $0.90{\pm}0.18\;mm$ in CT and was $0.75{\pm}0.11\;mm$ in MRI. There were not statistically significant difference between MRI and CT from the volume of protrusion prostate models (p=0.414). In MRI (p=0.139) and CT (p=0.057), there were not statistically significant difference between the real volume by planimetry technique and the measured volume by ellipsoid volume from exclusion of the protrusion as the starting points. While, there were statistically significant difference between the real volume by planimetry technique and the measured volume by ellipsoid volume from top of the protrusion as the starting points in MRI (p=0.005) and CT (p=0.005). For the accurate measurement of the protrusion prostate models, the craniocaudal length of the prostate should be measured from the exclusion of the protrusion as the starting points.

  • PDF

A Quantitative Method for Human Face Volume Using 3D Optical Measurement (3D 측정 기기를 이용한 얼굴의 부피 정량법 연구)

  • Park, Shin-Young;Nam,, Gae-Won;Kim, Seung-Hun;Lee, Hea-Kang;Ahn, Sung-Yeon;Moon, Seong-Joon;Kim, Han-Kon
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.34 no.4
    • /
    • pp.333-338
    • /
    • 2008
  • The evaluation for the visage volume was performed with human and dummy face using PRIMOS $body^{(R)}$. Three researchers measured the dummy face attached different volume of clay (6.6 mL, 13.2 mL, and 19.8 mL). It is identified that the high correlation between measured values and real volume ($R^2=0.99$). The percent (%) of relative standard deviation (RSD) of the data was shown below 10%. In Gage R&R analysis, the percent of contribution, the percent of study variation and distinct categories values were 0.78%, 8.85%, and 15% respectively. Therefore this method was regarded as the good standard condition in aspect of reproducibility and repetitiveness of data. The face volume variation was measured by PRIMOS $body^{(R)}$ on the face in participated 10 healthy Korean women volunteers. Subjects used the product once a day for two weeks as night sleeping pack. After application of the test products, the 3D image data of face were taken 1 and 2 weeks later. We found the face volume was significantly decreased after using products. In conclusion, this novel non-invasive technique was useful in measuring and visualizing alterations in face volume as a consequence of certain treatments. This system will provide a rapid and precise analysis of 3D topographical information for face.

The Effect of Sponge Padding on Edema Reduction (스펀지 패딩을 이용한 붕대법이 부종감소에 미치는 영향)

  • Kim, Sung-Joong;Yang, Hoi-Song;Yoon, Jung-Gyu
    • Physical Therapy Korea
    • /
    • v.10 no.3
    • /
    • pp.53-61
    • /
    • 2003
  • The purpose of this study was to determine the effects On the lymphedema patients of sponge padding and the correlation between the rate of edema reduction and downward shifting of bandages. Fifty secondary lymphedema patients with no infection, active cancer, limitation of movement, pain or drugs were randomly assigned to two groups: a sponge padding group, and a cotton padding group. Complex decongestive therapy was applied for 2 weeks. In each group the volume of the ankle, mid-calf, knee, and mid-thigh and downward shifting of bandages at the thigh was measured with measuring tape. The reduction of volume and downward shifting of bandages were analyzed by the unrelated t-test and the Pearson Correlation Test. The results were as follows: 1. In comparison between the sponge padding group and the cotton padding group, there was no significant difference in volume except in the thigh area. The edema volume was reduced significantly to $37.77{\pm}31.15%$ at the thigh with sponge padding after treatment (p<.05). 2. Bandage shifted 10.12 cm with cotton padding, but only shifted 2.85 cm when sponge padding was used. Sponge padding had an excellent effect in preventing the shifting of bandages. There was a significant difference in the amount of shifting that occurred with each type of padding (p<.05). 3. There was also a strong correlation between the reduction of edema and the shifting of bandage. These results suggest that short-stretch bandaging with sponge padding is more effective than bandaging with cotton padding. Further study on skin irritation and the comfort of sponge padding is needed to use padding materials safely and effectively.

  • PDF

Experimental Study on the Soot Formation Behavior of Octane Single Fuel Droplet Under the Constant Volume Combustion Conditions (정적 연소 조건에서 Octane 단일 연료 액적의 매연 생성 거동에 관한 연구)

  • Lim, Young Chan;Suh, Hyun Kyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.6
    • /
    • pp.389-395
    • /
    • 2017
  • This study was performed to provide the information of the soot formation behavior of octane single fuel droplet under the identical combustion conditions. To achieve this, this experimental study provide the results of the soot formation characteristics of octane droplet in accordance with different initial droplet diameter($d_0$), at the same time, experiment was conducted under the same combustion conditions which are 1.0atm of ambient pressure($P_{amb}$), 21% of oxygen concentration($O_2$) and 79% of nitrogen concentration($N_2$). Visualization of octane droplet combustion was performed by visualization system with high speed camera. The results of maximum soot volume fraction($f_{vmax}$) was almost the same under the equivalent ambient conditions regardless of initial droplet diameter. Furthermore, maximum soot volume fraction was showed the higher value in the measuring direction between $135^{\circ}$ and $315^{\circ}$ since the soot-tail is generated during two opposing igniters movement process.

Selection of Implants in Unilateral Prosthetic Breast Reconstruction and Contralateral Augmentation

  • Kim, Soo Jung;Song, Seung Yong;Lew, Dae Hyun;Lee, Dong Won
    • Archives of Plastic Surgery
    • /
    • v.44 no.5
    • /
    • pp.413-419
    • /
    • 2017
  • Background In breast reconstruction using implants after unilateral mastectomy, it is challenging to create a natural, ptotic contour, and asymmetry is a potential drawback. To achieve breast symmetry and an ideal shape for both breasts, we performed contralateral augmentation in patients undergoing breast reconstruction with implants. Methods Patients underwent unilateral mastectomy and 2-stage reconstruction. During the second stage of the procedure, contralateral augmentation mammoplasty was performed. Preoperatively, we obtained the patients' demographic information, and we then assessed breast volume, the volume and dimensions of the inserted implants, and complications. Breast symmetry was observed by the surgeon and was assessed by measuring the disparity between the final volume of each breast. Results Contralateral augmentation was performed in 52 cases. When compared to patients who did not undergo a contralateral balancing procedure, patients who received contralateral augmentation were younger, thinner, and had smaller breasts. During implant selection for contralateral augmentation, we chose implants that were approximately 1 cm shorter in width, 1 level lower in height, and 1 or 2 levels lower in projection than the implants used for reconstruction. The postoperative breast contours were symmetric and the final volume discrepancy between each breast, which was measured by 3-dimensional scanning, was acceptable. Conclusions We demonstrate that contralateral augmentation can be recommended for patients who perceive their breasts to be small and not beautiful in order to achieve an ideal and beautiful shape for both breasts. Furthermore, this study offers guidelines for selecting the implant that will lead to the optimal aesthetic outcome.

Comparison of Maximum Phonation Time Associated with the Changes in Vocal Intensity in Patients with Unilateral Vocal Fold Palsy and Sulcus Vocalis (성대마비와 성대구증의 강도 변화에 따른 최대발성지속시간 비교)

  • Choi, Se-Jin;Choi, Hong-Shik;Kim, Jae-Ock;Choi, Yae-Lin
    • Phonetics and Speech Sciences
    • /
    • v.4 no.1
    • /
    • pp.125-131
    • /
    • 2012
  • The patients with incomplete glottic closure have an important feature decreasing the maximum phonation time (MPT) because airflow rate or air leakage is greater than people without voice disorders. Also they can appear a problem in the intensity regulation. This study analyzed MPT difference based on the comfortable intensity and louder intensity and the correlation between MPT and respiration volume of unilateral vocal fold palsy (UVFP) and sulcus vocalis (SV) group. The twenty with UVFP, the 21 with SV, the 21 normal subjects measured MPT in /a/ vowel prolongation task with comfortable intensity and louder intensity and compared analysis by measuring FVC, $FEV_1$, $FEV_1/FVC$ to analyze the correlation between MPT and respiration volume. First, a comparison of MPT according to the intensity between groups is that MPT of the normal group was statistically significant long compared to the patient group in comfortable intensity, but MPT between groups was not statistically significant difference in the louder intensity. Second, an analysis of the correlation between MPT and respiration volume is that this was statistically significant correlation between MPT in comfortable intensity and MPT in louder intensity. But this did not show statistically significant correlation between intensity and respiration volume. This study can be supported the preceding study results deduced that shorting MPT of the patient group compared to the normal group was originated in the problem of laryngeal valving mechanism at the level of vocal folds rather than a problem of respiratory function. Also at the phonation by varying the intensity, the result can deduce that in the case of patient group, the length of MPT had been improved by increasing the glottal closure ratio in the louder intensity. These results can support the theoretical basis that should be applied to the clinicians by varying the intensity at the voice evaluation and voice therapy for the patients with the glottis incompetence.

Carburization Characteristics of MERT Type KHR-45A Steel in Carbon Rich Environment (Carbon Rich 분위기에서의 KHR45강의 침탄특성 평가 연구)

  • Lim, Jae Kyun;Yang, Gimo;Ihm, Young Eon
    • Korean Journal of Materials Research
    • /
    • v.23 no.5
    • /
    • pp.293-298
    • /
    • 2013
  • In this study, an HP-mod. type(KHR-45A), which is used as a heater tube material in the pyrolysis process, was evaluated for its carburizing properties. It was confirmed from the microstructural observation of the tubes that the volume fraction of carbide increased and that the coarsening of Cr-carbide generated as a degree of carburization increased. The depth of the hardened layer, which is similar to the thickness of the carburized region of each specimen, due to carburization is confirmed by measurement of the micro-Vickers hardness of the cross section tube, which thickness is similar to that of the carburized region of each specimen. Two types of chromium carbides were identified from the EBSD (electron back-scattered diffraction) image and the EDS (energy-dispersive spectroscopy) analysis: Cr-rich $M_{23}C_6$ in the outer region and Cr-rich $M_7C_3$ in the inner region of tubes. The EDS analysis revealed a correlation between the ferromagnetic behavior of the tubes and the chromium depletion in the matrix. The chromium depletion in the austenite matrix is the main cause of the magnetization of the carburized tube. The method used currently for the measurement of the carburization of the tubes is confirmed; carburizing evaluation is useful for magnetic flux density measurement. The volume fraction of the carbide increased as the measuring point moved into the carburized side; this was determined from the calculation of the volume fraction in the cross-section image of the tubes. These results are similar to the trends of carburization measurement when those trends were evaluated by measurement of the magnetic flux density.

An Experimental Study on Engineering Characteristics of Wet Dredged Soil and Dry Dredged Soil after Chemical Treatment (습윤준설토와 노건조준설토의 약품처리 후 공학적 특성에 관한 실험적 연구)

  • Chang, Yongchai;Park, Kiyoun;Park, Jongcheol;Lee, Ingyu
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.3
    • /
    • pp.71-76
    • /
    • 2012
  • Since sediment in a stable state is disturbed during the process from sediment in a natural state to dredged soil, the turbidity of water is not good. When the dredged soil settles again, the volume change in the sediment occurs. Coagulant and flocculant are added for turbidity mitigation of the water and faster settling process of suspended solid, and the amount of the substances affects the characteristics of the dredged soil. This study is to investigate the characteristics of the dredged soil depending on the amount of three chemical products added to the wet dredged soil and the dry dredged soil through measuring the suspended solids (SS), volume change and sedimentation velocity. The experimental measurements show that the SS decreased, the volume change rate increased, and the sedimentation velocity increased, as the chemical amount increased. In addition, it was found that the dry dredged soil reacted even with little quantity of the chemicals because derelict and microorganism are removed due to the drying process at $100{\pm}5^{\circ}C$.