• Title/Summary/Keyword: measuring volume

Search Result 793, Processing Time 0.027 seconds

Comparison of the Performance of the VAV Dampers for the Circular Duct (원형 덕트용 VAV 댐퍼의 성능 비교)

  • Kwon, Young-Pil
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.9
    • /
    • pp.699-703
    • /
    • 2012
  • The performance of the typical VAV dampers; blade type, venturi type and blade-orifice type, for the circular duct, is obtained by measuring the volume flow rate as a function of the opening degree. The performance features are discussed by comparing the volume flow rate of each damper. It is shown that the blade-orifice type damper, recently developed, is excellent in its linearity of the performance and that it is worse than the blade type but much better than the venturi type in its flow resistance.

The Rehydration Properties of Amorphous Alumina Powder in Low Water/Alumina Ratio (낮은물/알루미나 비에서 비정질 알루미나 분말의 수화특성)

  • 박병기;서정권;이정민;서동수
    • Journal of the Korean Ceramic Society
    • /
    • v.35 no.10
    • /
    • pp.1085-1093
    • /
    • 1998
  • Amorphous alumina powder prepared by the fast calcination of aluminum trihydroxide(Al(OH)3 gibbsite) for 0.5 second at 580$^{\circ}C$ was investigated rehydration propeties. Phase composition crystal size and mor-phology surface area pore volume and pore size distribution of pesudo-boehmite and bayerite crystals changed with temperature time water/alumina ratio and particle size when amorphous alumina rehydrated with water. Phase compositions were examined with XRD and DTA and crystal sized morphologies were investigaed with SEM and TEM. Also rehydration properties of amorphous alumina were in-vestigated by measuring the surface area pore volume and pore size distribution.

  • PDF

Flame Propagation Characteristics of Propane-Air Premixed Mixtures (프로판-공기 예혼합기의 화염전파 과정에 관한 연구)

  • Bae, Choong-Sik
    • Journal of the Korean Society of Combustion
    • /
    • v.1 no.2
    • /
    • pp.21-29
    • /
    • 1996
  • Flame propagation characteristics of propane-air mixtures were experimentally investigated in constant-volume combustion chambers. Flame propagation process was observed as a function of mixture strength, initial mixture temperature and initial mixture pressure in quiescent mixtures. A cylindrical combustion chamber and a spherical combustion chamber contain a pair of parallel windows through which optical access into the chamber can be provided. Laser two beam deflection method was adopted to measure the local flame propagation, which gave information on the flame size and flame propagation speed. Pressure development was also measured by a piezoelectric pressure transducer to characterize combustion in quiescent mixtures. Burning velocity was calculated from flame propagation and pressure measurements. The effect of flow on flame propagation was also investigated under flowing mixture conditions. Laser two beam method was found to be feasible in measuring flame propagation of quiescent mixtures. Flame was observed to propagate faster with higher initial mixture temperature and lower initial pressure. Combustion duration was shortened in the highly turbulent flowing mixtures.

  • PDF

Earthwork Volume Calculation of Anchorage Underground Capacity Using Laser Scanner (레이저스캐너를 이용한 앵커리지 지하공동의 토공량 산정)

  • Choi, Seok-Keun;Kim, Dong-Yeun
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.18 no.3
    • /
    • pp.21-27
    • /
    • 2010
  • When the capacity of underground caverns' structures is measured, a general surveying is difficult to decide an accurate section of irregular shape and a photographic surveying has problems on picture acquisition due to underground dusts, noise and lighting conditions, etc. The laser scanner system is being much used for 3-dimensional modeling such as topography, planimetric features and structures, etc. without a target by measuring arriving time of a laser pulse reflected after scanning the laser pulse and calculating space coordinates of the reflection position. Accordingly, the present research carried out section and earthwork volume measurement of a tunnel by using a laser scanner in underground anchorage excavation work that a bridge construction is being executed.

Modeling on Daily Traffic Volume of Local State Road Using Circular Mixture Distributions (혼합원형분포를 이용한 지방국도의 시간교통량 추정모형)

  • Na, Jong-Hwa;Jang, Young-Mi
    • The Korean Journal of Applied Statistics
    • /
    • v.24 no.3
    • /
    • pp.547-557
    • /
    • 2011
  • In this paper we developed a statistical model for traffic volume data which collected from a spot of specific local state road. One peculiar property of daily traffic data is that it has bimodal shape which have two peaks on times of both going to office and coming back to home. So, various mixture models of circular distribution are suggested for bimodal traffic data and EM algorithms are applied to estimate the parameters of the suggested models. To compare the accuracy of the suggested models, classical regressions with dummy variables are also considered. The suggested models for traffic volumn data can be effectively used to estimate missing values due to measuring instrument disorder.

Relationship between Climate Factors and Relative Growth of Pinus rigida and Castanea crenata in the Cheongju Area of Chungbuk (충북 청주지역 리기다소나무와 밤나무의 상대 생장률과 기후인자와의 관계)

  • Kim, Kee Dae
    • Journal of Environmental Science International
    • /
    • v.26 no.5
    • /
    • pp.585-590
    • /
    • 2017
  • The Diameter at Breast Height (DBH) provides information about the volume growth of a tree. In this study, we estimated the relative growth rates of Castanea crenata and Pinus rigida as 4.07% and 3.73%, respectively. Although the difference was low, we demonstrated that the growth rate of C. crenata is slightly faster than that of P. rigida. After calculating the relative growth rate for each section, we found that the relative growth of C. crenata decreased with time. However, the relative growth rate of P. rigida showed an overall increase. The gap widths of both species showed an increasing trend. However, the gradient of the two species was different. The gradient of C. crenata was approximately 12.0, but that of P. rigida was approximately 4.7. This means that the volume growth of C. crenata was faster than that of P. rigida during 4 years. However, this was relatively a short period for measuring the volume growth pattern, and we believe that additional useful information can be obtained by conducting long-term ecological monitoring. Results of canonical correspondence analysis showed that among the climate variables, temperature was significantly related to the gap widths for both species.

Development of the MVS (Muscle Volume Sensor) for Human-Machine Interface (인간-기계 인터페이스를 위한 근 부피 센서 개발)

  • Lim, Dong Hwan;Lee, Hee Don;Kim, Wan Soo;Han, Jung Soo;Han, Chang Soo;An, Jae Yong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.8
    • /
    • pp.870-877
    • /
    • 2013
  • There has been much recent research interest in developing numerous kinds of human-machine interface. This field currently requires more accurate and reliable sensing systems to detect the intended human motion. Most conventional human-machine interface use electromyography (EMG) sensors to detect the intended motion. However, EMG sensors have a number of disadvantages and, as a consequence, the human-machine interface is difficult to use. This study describes a muscle volume sensor (MVS) that has been developed to measure variation in the outline of a muscle, for use as a human-machine interface. We developed an algorithm to calibrate the system, and the feasibility of using MVS for detecting muscular activity was demonstrated experimentally. We evaluated the performance of the MVS via isotonic contraction using the KIN-COM$^{(R)}$ equipment at torques of 5, 10, and 15 Nm.

On the Approach for the Volume and the Surface Area of Solid Figures in the Middle School (중학수학에서의 입체도형의 부피와 겉넓이의 접근방법에 대한 고찰)

  • Hong, Gap-Ju;Choi, Young-Gi;An, Suk-Young;Kim, Kun-Uk
    • Journal of Educational Research in Mathematics
    • /
    • v.18 no.1
    • /
    • pp.81-101
    • /
    • 2008
  • This study points out that the way of teaching varies according to the kinds of figures in explaining the volume and the surface area of solid figures in the seventh grade curriculum. Especially, the study discusses the limitation of the explanation depending on the experimental method using physical objects. Considering the study of Archimedes' research about measuring sphere, we investigate its educational implications and, based on this result, suggest the complementary approach and the considerations for applying to current school mathematics curriculum.

  • PDF

A Development Of The Portable Spirometry System Of Pressure Method Using Static Pressure In Pitot Tube (개구관에서의 정체압을 이용한 차동 압력 방식의 휴대형 호흡측정 시스템 개발)

  • 이종수;신창민;김영길
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.6
    • /
    • pp.479-486
    • /
    • 2001
  • Spirometer is a medical equipment which diagnoses respiratory function by measuring 9as volume across Patient's lunes through airway. Because a little overdose of anesthesia medicine can take away Patient's life in the ventilator for a surgical operation. an exact measurement of respiring volume is very important. This Paper Presented an exact flow volume calculation method from factors having an influence on measurement and introduced a spirometry system for an anesthesia ventilato. This system, using differential Pressure sensor measured flow by mutual relation with Pressure. temperature. gas density and linearization from the 2nd order characteristics of differential pressure with flow.

  • PDF

Exploring Relationships between Urban Tree Plantings and Microclimate Amelioration (도시 수목식재와 미기후 개선의 상관성 구명)

  • Jo, Hyun-Kil;Ahn, Tae-Won
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.34 no.5 s.118
    • /
    • pp.70-75
    • /
    • 2006
  • The purpose of this study is to explore the effects of difference in urban tree plantings on microclimate amelioration, and to suggest essential information for quantifying urban energy budgets and energy savings. This study was focused on measuring and analyzing air temperature and relative humidity in summer. Daytime air temperatures at places with 8%, 24%, 44%, 79%, and 100% cover of woody plants were, respectively, $0.6^{\circ}C,\;1.3^{\circ}C,\;2.4^{\circ}C,\;3.5^{\circ}C,\;and\;4.8^{\circ}C$ cooler, compared to a place with 0% cover. A 10% increase of woody plant cover was estimated to reduce the temperature by approximately $0.55^{\circ}C$. The temperature reduction effects were relatively greater between places with lower cover of woody plants than between those with higher cover. Woody plant cover and crown volume were the appropriate indicators which quantified the effects of tree plantings on air temperatures, based on the correlation analysis. Regression equations to estimate temperature change ($Y:^{\circ}C$) using woody plant cover ($X_1:%$) or crown volume ($X_2:m^3$) as independent variables are as follows: $$1nY=3.3233-0.0018X_1\;(r^2=0.99,\;p<0.0001)\;Y=27.5297-0.0019X_2\;(r^2=0.96,\;p=0.0007)$$