• Title/Summary/Keyword: measuring volume

Search Result 793, Processing Time 0.024 seconds

Electrical properties of insulating oils for automobile ignition coil (자동차 점화코일용 절연유의 전기적 특성)

  • 신종열;홍진웅
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.5
    • /
    • pp.172-177
    • /
    • 1999
  • In this paper, the physical and electrical properties of the synthetic fluids No. 2 class Ⅶ used the insulating oils for automobile ignition coil are studied. Also, benzotriazole(BTA) as the streaming electrification suppressant additive is added to the oil, and the change of physical and electrical properties due to different BTA concentration is investigated. To investigate the electrical characteristics, the breakdown strength of each specimen by an experiment for AC breakdown and the changes of conductivity by measuring volume resistivity are analyzed. It is considered that the effective content of BTA as charge suppressant additive is about 10[ppm] from the results of AC breakdown and volume resistivity test.

  • PDF

Fabrication of PTFE/Al Composite Materials by Hot Press Process (가압소결에 의한 PTFE/AI 복합재료 제조)

  • 이길근;김우열
    • Journal of Powder Materials
    • /
    • v.9 no.2
    • /
    • pp.103-109
    • /
    • 2002
  • To investigate the fabrication possibility of a polymer particle dispersed metal matrix composite, polytetrafluorothylene (PTFE) particles were incorporated into the Al by the powder metallurgy process. The characteristics of a PTFE/Al composite were evaluated by measuring the density and hardness, and analysis of XRD, FT-Raman and microstructure. And wear properties of these composites were evaluated under the dry wear condition. It was possible to obtain the PTFE particles stably dispersed Al matrix composites by the hot press process at the sintering temperature of $500^{\circ}C$. The wear coefficient of a PTFE/Al compoite decreased with increasing of the volume fraction of PTFE. The wear weight of a PTFE/Al composite increased with increasing of the volume fractionof PTFE in the range of 0~10 vol.%PTFE, and showed maximum value at 10 vol.%PTFE, and then decreased at 20vol.%PTFE.

Atomization Characteristics for Various Injection Nozzle Type and Property Changes (분사노즐 형상에 따른 유화연료의 분무 미립화 및 물성)

  • Kim, Yong-Guk;Ryu, Jeong-In
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.4
    • /
    • pp.62-67
    • /
    • 2010
  • The objective of this experimental study is to verify atomization characteristics of emulsified fuel. The emulsified fuel made of adding the ultrasonic energy is analyzed with atomization characteristics and chemicophysics. As water contents within emulsified fuel and needle angle increase, SMD, viscosity and surface tension were analyzed. By measuring the distribution percentage of hydrogen volume by $^1H$-NMR spectrum, the proportion of aromatics and paraffins is analyzed and compared each other. The results of study is as follows. First, as water contents within emulsified fuel and needle angle of nozzle increases, SMD increases. Second, for the distribution percentage of hydrogen volume, the distribution percentage of aromatics is about 10% and the rest portion is paraffins.

Effect of Heat Treatment Temperature on Amount of Stress-Induced ${\varepsilon}$ Martensite in an Fe-Mn Baesd Alloy (Fe-Mn계 합금에서 응력유기 ${\varepsilon}$ 마르텐사이트의 양에 미치는 열처리 온도의 영향)

  • Jee, K.K.;Han, J.H.;Jang, W.Y.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.17 no.6
    • /
    • pp.342-345
    • /
    • 2004
  • In this work, a new method of measuring volume fraction of deformation-induced ${\varepsilon}$ martensite is proposed using endothermic heat on reverse transformation. As grain size increases, the amount of ${\varepsilon}$ martensite forming on cooling increases. However, with a decrease in grain size, more ${\varepsilon}$ is induced by deformation, improving shape memory effect.

Estimating the Optimal Ratio of Standard Pallet Use for Logistics Standardization

  • Hong, Sung-Wook;Lee, Soon-Cheul
    • Journal of Korea Port Economic Association
    • /
    • v.22 no.1
    • /
    • pp.1-15
    • /
    • 2006
  • This paper analyzes how levels of logistics standardization are related to logistics costs. The study surveyed ratios of standard pallet use in order to measure levels of firms' standardization in logistics management. Research focused on how firms' logistics costs were related to their levels of logistics standardization and ratios of standard pallet use. After measuring use of standard pallets and logistics costs, optimal levels of logistics standardization were estimated based on survey data. Logistics costs and standardization were more related to labor than to freight volume or export. Results indicated that firms could reduce logistics costs by raising levels of logistics standardization; optimal levels of standard pallet use out of Korean firms' total manufacturing cargo volume were estimated at 44.26% for multi-standard pallets and 57.99% for a single standard pallet (a unit load system). The study demonstrated that adopting a single standard pallet results in better cost saving logistics systems than use of multi-standard pallet types. These results may explain why firms pursue standardization in logistics systems.

  • PDF

The Introduction of the Trim & List Sensor and Confirm of the Sensor Location (Trim & List Sensor의 소개와 설치위치 확정)

  • Song, Young-Seung;Park, Kyeng-Ryong;Nam, Sung-Il
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2008.09a
    • /
    • pp.33-37
    • /
    • 2008
  • The evidence of the Cargo tank volume is very important between Buyer and Seller for agreement each other for LNG Ship. CTS(Custody Transfer System) Radar type level gauging sensor to be measured for cargo volume. The data of Trim & List sensor to be compensated for measuring data which is original data of the CTS sensor. The latest days, the Buyer would have posed a problem both the location and the accuracy of trim/list sensor specially neared final stage of the ship's delivery. So, we would like to report the introducing to the trim/list sensor and the confirmation of actual location for the trim/list sensor.

  • PDF

Measurement Data Comparison of Fast SAR Measurement System by Probe Arrays with Robot Scanning SAR Measurement System

  • Kim, Jun Hee;Gimm, Yoon-Myoung
    • Journal of electromagnetic engineering and science
    • /
    • v.14 no.4
    • /
    • pp.336-341
    • /
    • 2014
  • Dosimetry of radiating electromagnetic wave from mobile devices to human body has been evaluated by measuring Specific Absorption Rate (SAR). Usual SAR measurement system scans the volume by robot arm to evaluate RF power absorption to human body from wireless devices. It is possible to fast estimate the volume SAR by software deleting robot moving time with the 2D surface SAR data acquired by arrayed probes. This paper shows the principle of fast SAR measurement and the measured data comparison between the fast SAR system and the robot scanning system. Data of the fast SAR is well corresponding with data of robot scanning SAR within ${\pm}3$ dB, and its dynamic range covers from 10 mW/kg to 30 W/kg with 4.8 mm probe diameter.

Cosmic Web traced by ELGs and LRGs from the Multidark Simulation

  • Kim, Doyle;Rossi, Graziano
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.1
    • /
    • pp.72.1-72.1
    • /
    • 2016
  • Current and planned large-volume surveys such as the Sloan Digital Sky Survey extended Baryon Oscillation Spectroscopic Survey (SDSS IV-eBOSS) or the Dark Energy Spectroscopic Instrument (DESI) will use Luminous Red Galaxies (LRGs) and Emission Line Galaxies (ELGs) to map the cosmic web up to z~1.7, and will allow one to accurately constrain cosmological models and obtain crucial information on the nature of dark energy and the expansion history of the Universe in novel epochs - particularly by measuring the Baryon Acoustic Oscillation (BAO) feature with improved accuracy. To this end, we present here a study of the spatial distribution and clustering of a sample of LRGs and ELGs obtained from a sub-volume of the MultiDark simulation complemented by different semi-analytic prescriptions, and investigate how these two different populations trace the cosmic web at different redshift intervals - along with their synergy. This is the first step towards the interpretation of upcoming ELG and LRG data.

  • PDF

A Study on Improvement of the Accuracy of SV Measurement obtained by Hand to Hand Impedance. (양손 임피던스법에 의한 SV 측정의 정확도 향상을 위한 연구)

  • Yoon, Chan-Sol;Yeom, Ho-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.8
    • /
    • pp.1251-1255
    • /
    • 2015
  • The purpose of this study is to measurement the cardiac output using hand to hand impedance method to provide convenience to user when measuring SV(stroke volume) with the use of ICG(Impedance Cardiography). We suggest the optimized modified formula, which can be applied when using impedance with the use of hand to hand Impedance. To verify this formula, a SV from transthoracic approach and hand to hand approach are compared for the 36 subjects, respectively. The acquired data was analyzed by using LabVIEW 8.6, analysis was implemented by SPSS 12.0. Fine difference was shown by individual. We showed that as a result of analyzing the ICG measurement value on thoracic and hand to hand, the correlation with SV was r=0.716, thereby having indicated the results of regression model in relatively high correlation.

A Photochromic Dye Activation Method for Measuring the Thickness of Liquid Films

  • Kim, Jeong-Bae;Kim, Moo-Hwan
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.6
    • /
    • pp.966-970
    • /
    • 2005
  • To measure the thickness of liquid films from 10 to 60 ${\mu}m$, we used photochromic dye activation. And we used silicone oil with 10 centi-Stokes and commercial photochromic dyes. To make films with exact and known thicknesses, we used two glass wafers. A film formed between two wafers after placing a drop of liquid of known volume on one wafer and covering the other. The film thickness could be estimated from the diameter of wafer and the dropped liquid volume. To quantitatively evaluate the result, captured the images using digital camera then analyzed the images using the image tool. The gray scale intensity using the captured images of activated dye with these thicknesses showed the repeatability below ${\pm}$ 1.0% when measured with a silicone oil solution containing 0.1% SO and SO-ANTH dyes. And we showed that photochromic dye activation method could be used to measure our liquid film thickness ranges.