• 제목/요약/키워드: measuring vessel

검색결과 156건 처리시간 0.026초

어획능력(Fishing Capacity)의 측정과 감축수준 결정에 관한 연구 -기선권현망어업을 중심으로- (A Study on the Measurement of Fishing Capacity and the Determination of Its Reduction Levels)

  • 이정삼;김도훈
    • Ocean and Polar Research
    • /
    • 제28권4호
    • /
    • pp.439-449
    • /
    • 2006
  • This study was aimed at measuring the fishing capacity of Powered Anchovy Drag Net Fisheries (PADNF) in Korea using Peak-to-Peak(PTP) and Data Envelopment Analysis(DEA) methods recommended by FAO. In the analysis, both fishing capacities of total PADNF and individual PADNF vessels were measured with time series data and cross sectional data, respectively. In addition, the results of the DEA measurement were analyzed in order to determine reduction levels of fishing capacity. In case of total PADNF, the results by rn and DEA methods showed a similar rate of capacity utilization (79%), indicating the capacity was not utilized enough. In addition, the sensitivity analysis suggested that the number of vessels should be reduced by 20%, and the gross tonnage and the horse power should be reduced by 20% and 21%, respectively if the current catch is to stay at the 2004 level. The DEA results on individual PADNF vessels indicated the capacity utilization was 75% on average, showing some differences in capacity utilization among vessels (31%-100%). The results of the study would be useful for measuring production efficiency in PADNF. They would also provide good policy information for efficient use of resources and capacity reduction levels, which are useful far vessel buyback programs of coastal and offshore fisheries.

단층촬영영상을 이용한 T.O.D Calibration의 정확성과 유용성에 관한 비교연구 (Comparative Study on Accuracy and Usefulness of Calibration Using CT T.O.D)

  • 서정범;김동현;이정범
    • 대한디지털의료영상학회논문지
    • /
    • 제13권1호
    • /
    • pp.39-48
    • /
    • 2011
  • Uses a Tomographic scan image and Table Object Distance(TOD) price after measuring, uses accuracy and usability of blood vessel diameter(Vessel Diameter) measurement under comparison evaluating boil TOD Calibration. The patient who enforces Prosecuting Attorney abdomen Tomographic scan in the object the superior mesentery artery uses PACS View from abdomen fault image and from blood vessel diameter and the table measures the height until of the blood vessel. Uses Angio Catheter from Angiography(5 Fr.) and enforces is measured from PACS View the height until of the table which and the blood vessel at TOD Calibration price and the size of the superior mesentery artery inputs measures an superior mesentery artery building skill. Catheter Calibration input Agnio Catheter where uses in Angiography the size of the superior mesentery artery at Catheter Calibration price and they measure. Produced an accuracy from monitoring data and comparison evaluated. The statistical program used SPSS. TOD Calibration accuracy was 96.53%, standard deviation is 0.03829. Catheter Calibration accuracy of 92.91%, standard deviation is 0.05085. Represents a statistically significant difference(p = 0). According to age and gender was not statistically significant(p > 0.05). TOD Calibration correlation coefficient R-squared of 88.8%, Catheter Calibration of the R-squared is 75.5%. High accuracy of both methods. Through this study, CT images using the measured distance between the table and the Object, TOD Calibration accuracy higher than two Catheter Calibration was measured. TOD and Catheter Calibration represents a statistically significant difference(p = 0).

  • PDF

오징어 채낚기 어선의 추진기 개선을 통한 성능향상 (Improving of propulsion performance of 24 ton class squid jigging vessel)

  • 정성재;안희춘;김인옥;차봉진;구명성;이경훈
    • 수산해양기술연구
    • /
    • 제52권4호
    • /
    • pp.347-355
    • /
    • 2016
  • In this study, a new designed propeller was applied on 24 ton class squid jigging vessel to reduce of fuel consumption. The selected squid jigging boat was under construction at the shipyard to determine the resistance of the hull through the model experiment. The propeller design was carried out by using the experimental data and ITTC procedures. Sea trials were performed by measuring the speed and the horsepower required by the condition of five power levels of engine load, namely 70%, 80%, 90%, MCR and maximum engine power. The speed and delivered horse power were compared between the conventional propeller and the new design propeller. Delivered horse power by installing the new propeller takes 90% engine load at start-up conducted by decreased 9.06%. The measuring speed is increased up to the 0.6 knots in the low-speed range to high range. This study showed that only the design and installation of a new propeller can improve the propulsion efficiency of the boats; furthermore, reduce fuel costs can be achieved at the same time by improving the increased cruising speed.

바이스펙트럼해석을 이용한 혈관의 비선형 맥동전파특성 계측에 대한 모의실험 (A Sham Experiment for the Measurement of Nonlinear Pulse Propagation Characteristics of Blood Vessel Using Bispectral Analysis)

  • 장경영;김경조
    • 대한의용생체공학회:의공학회지
    • /
    • 제16권4호
    • /
    • pp.525-532
    • /
    • 1995
  • 이 연구는 다음 두가지 사실에 기초를 두고 있다. 첫째, 혈관의 맥동은 전통적으로 동양의 한방에서 오랫동안 인체진단을 위해 사용되어져 왔다는 것이고, 둘째는 신체조직에서 파동의 비선형전파특성이 의용진단에 유용한 정보를 준다는 것이다. 따라서, 혈관의 벽을 전파하는 맥동파의 비선형전파특성은 의용진단을 위하여 효과적으로 이용될 수 있다는 것을 예측할 수 있다. 본 논문에서는, 혈관을 따른 두 지점에서 변위파형을 초음파 도플러 신호에 대한 직교검파에 의해 구하고, 여기에 바이스펙트럼해석과 볼테라모델전개를 적용하여 두지점 사이의 비선형 전달함수를 추정하며, 이것이 의용진단에 적용가능한지 모의샘플에 대하여 고찰하는 것을 목적으로 한다.

  • PDF

두개의 엔코드 초음파 센서를 이용한 측정면의 두께 측정 및 위치 측정 (Measurement of Thickness and Position of the Surface using the Two Encoder Ultrasonic Sensors)

  • 강명철;장유신;김형국;배종일;이만형
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2002년도 춘계학술대회 논문집
    • /
    • pp.510-514
    • /
    • 2002
  • The 3-dimensional measuring machine by using an ultrasonic sensor is used one of the NDE(Non Destructive Examination). It is applied to the inspection of pipelines, boreholes, pressure vessel and tank, and so on. In particular when a harsh environment prohibits the use of moving mechanical parts. The 3-dimensional measuring machine by using an ultrasonic sensor, which measure 1-dimensional information and 2-dimensional information simultaneously from a target of inspection, and then reembody 3-dimensional information. So we can find the situation in progress and predict remaining life and corrosion without destructive examination. It's a point of excellence that the 3-dimensional measuring machine is portable.

  • PDF

A Technique for Measuring Ship's Draught by ultrasonic Pulse Signal

  • Lee, Eun-Bang;Lee, Sang-Jib
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 1995년도 VTS and IBS 95 The Korean Institute of Navigation 1995년도
    • /
    • pp.184-192
    • /
    • 1995
  • Although ship's draught information onboard is substantial for both the safety of navigation and the estimation of loaded cargoes its accuracy depends in traditional surveying method on the skillfulness of observers and the condition of the sea surface round the vessel. To obtain more accurate information accessibly measuring instruments with sophisticated sensors such as mechanical electronic and ultrasonic transducers have been developed. however they have still limitation in accuracy and in making up a system due to the complexity of processing signal. In this paper we propose a he technique for analyzing ultrasonic pulse signal in order to improve the measurement accuracy and simplify a remote sensing system of draught by ultrasonic waves. This technique is useful for measuring draught being considered the influence of sea surface fluctuation and for transferring its data briefly to required equipment in integrated bridge system.

  • PDF

비파괴 검사 응용을 위한 기구부의 3차원 기구학적 해석 (3-Dimensional and Kinematic Analysis of a System for NDE(Nondestructive Examination))

  • 김형국;안희태;이동활;박재훼;이만형
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 D
    • /
    • pp.2199-2201
    • /
    • 2001
  • The 3-dimensional measuring machine by using an ultrasonic sensor is used one of the NDE(Nondestructive Examination). It is applied to the inspection of pipelines, boreholes, pressure vessel and tank, and so on. In particular when a harsh environment prohibits the use of moving mechanical parts. The 3-dimensional measuring machine by using an ultrasonic sensor, which measure 1-dimensional information and 2-dimensional information simultaneously from a target of inspection, and then reembody 3-dimensional information. So we can find the situation in progress and predict remaining life and corrosion without destructive examination. It's a point of excellence that the 3-dimensional measuring machine is portable.

  • PDF

Transcranial Doppler를 이용(利用)한 태음인 중풍환자의 혈류속도(血流速度)와 혈관(血管) 반응성(反應性)에 대한 임상적(臨床的) 고찰(考察) (Clinical study of blood flow and vascular reaction in Taeumin CVA patients using Transcranial Doppler)

  • 임종필;배나영;한경수;안택원
    • 혜화의학회지
    • /
    • 제15권2호
    • /
    • pp.263-272
    • /
    • 2006
  • Purpose Brain vessles have autoregulation function, so even when perfusion pressure drops, cerebral blood flow remain stable by vasodilation. Latest research on this reserve of cerebral vessels is being done using TCD, which measures the reserve of the vessels. We did a research comparing cerebral vessel and peripheral vessel reserve between Taeumin, who are more likely to suffer CVA, and the normal. We observed blood flow of Internal carotid artery siphon and radial indicis artery of the two group with TCD. Method We picked 20 people out of patients diagnosed as cerebral infarction at Cheon-An Oriental hospital of Daejeon University. They were diagnosed as Taeumin with QSCCII questionnaire and constitutional differentiation. Using TCD, we measured highest blood flow rate, mean blood flow and asymmetric counting blood flow of Internal carotid artery siphon and radial indicis artery at rest. And then we measured again after stimulating cerebral vessels, by triggering hypercapnia by self apnea and peripheral vessels by palm heating. Result At rest, mean blood flow rate of Internal carotid artery siphon showed significant decrease compared to control group. Blood flow rate of Internal carotid artery siphon after hypercapnia showed significant decline in highest blood flow rate and mean blood flow compared to control group. Cerebral vessel reaction after the hypercapnia induction showed great change in experiment group than the control group. Peripheral vessel reaction after palm heating showed significant decline in experiment group compared to control group. Conclusion In conclusion, measuring the alteration of blood flow used in diagnosing cerebral infarction, is more sensitive when vessel stimulation is done. Non-invasive TCD is effective especially in case of Taeumin who are more likely to suffer vascular disorder than others.

  • PDF

Determination of the Boundary between Juvenile-Mature Wood of Diospyros kaki and Their Wood Anatomical Variations

  • Eka KARTIKAWATI;BIENITTA;Fanany Wuri PRASTIWI;Widyanto Dwi NUGROHO
    • Journal of the Korean Wood Science and Technology
    • /
    • 제52권2호
    • /
    • pp.191-203
    • /
    • 2024
  • Persimmon wood (Diospyros kaki) is a seasonal fruit-producing plant with a beautiful dark pattern in its wood that is suitable for high-quality furniture, sculptures and musical instruments. The utilization of persimmon wood can be improved by determining its anatomical characteristics, such as juvenile and mature wood. This study aimed to determine the boundaries between juvenile and mature wood and observe the anatomical properties of juvenile and mature wood and their variations in the axial direction. Three 30-year-old persimmon (D. kaki) trees grown in Karo, North Sumatra, Indonesia, were used in this study. The boundary between juvenile and mature wood was determined by measuring the fiber length and vessel element length from near the pith to near the bark. Anatomical observations were conducted in the juvenile and mature wood areas. The results showed that the average boundaries between juvenile and mature wood were 44.11 mm from the pith and were not significantly different in the axial direction of the trees. Furthermore, the wood anatomy categories of juvenile and mature wood differed significantly in terms of fiber diameter, fiber proportion, vessel proportion, and axial parenchyma proportion. In the axial direction, vessel diameter, ray parenchyma frequency, and ray parenchyma proportion at the base, middle, and top of the tree were significantly different.

비자성체 용기 가열을 위한 Induction Cooker 공진 네트워크 설계 및 검증 (Resonant Network Design and Verification of Induction Cooker for Heating Nonmagnetic Vessel)

  • 장은수;박상민;주동명;이병국
    • 전력전자학회논문지
    • /
    • 제22권6호
    • /
    • pp.504-509
    • /
    • 2017
  • This paper proposes a procedure for designing a resonant network for induction cookers that enables the induction heating of magnetic and non-magnetic vessels. In order to design such network, the range of operating frequency must be determined according to the material of the vessels by measuring several parameters, such as equivalent resistance and inductance, which are reflected in the working coil of the vessels. Through this process, the capacitance of the resonant capacitor is determined. The PSIM simulation and experiment results verify the feasibility of the proposed design and the heating performance of the designed resonant network.