• Title/Summary/Keyword: measuring vessel

Search Result 158, Processing Time 0.026 seconds

The Study on the Survey Technique and a Development of Measuring Method about a Wooden Pattern of the Small Vessel (소형선박 완성목형의 검사기법 및 측정방법 개발에 관한 연구)

  • +Jeong, Yong-Geun;Kang, Dae-Sun;Ku, Hyoun-Mo;Lee, Ki-Dong
    • Journal of Korea Ship Safrty Technology Authority
    • /
    • s.23
    • /
    • pp.65-77
    • /
    • 2007
  • This study is about the survey technique and the development of measuring method about a wooden pattern of the small vessel made by CNC Machine. we will propose a survey method about processing grade, objectivity of survey, an external shape and a surface defect survey method, Furthermore, CMM(Coordinate Measuring Machine) and OMM(On Machine Measurement).

  • PDF

Development of the Selection Technique of Entrapment Materials for the Viability Improvement of Entrapped Bifidobacteria (포집된 Bifidobacteria의 생존력 증대를 위한 세포포집재료의 선별기술 개발)

  • 이기용;우창재;배기성;허태련
    • KSBB Journal
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 2000
  • The diffusion effect of simulated gastric juices into the various alginate vessel containing each biopolymer such as 0.3% soluble starch, whey, corn starch, agar, locust bean gum, guar gum, gum arabic, pectin, gelatin and 0.15% xanthan gum was tested by measuring the change of pH in the vessel. The degree of viability of bifidobacteria entrapped in each bead containing biopolymers was corresponded with the degree of diffusion inhibition of hydrogen into the each vessel. Therefore, The determination of diffusion inhibition of simulated gastric juices into the various vessel by measuring the change of pH in the vessel may be effectively used as the simple method to select the optimal entrapment lattice for the improvement of bifidobacteria viability. Bifidobacteria entrapped in alginate bead containing 0.15% xanthan gum whose lattice showed the lowest hydrogen diffusion were more significantly tolerant against bile salts and hydrogen peroxide than untrapped bifidobacteria. It was also observed that the viability of bifidobacteria entrapped in bead was nto nearly changed in milk adjusted pH 4.5 with organic adids at $4^{\circ}C$ for 10 days. Therefore, use of alginate containing 0.15% xanthan gum as a cell matrix for entrapping bifidobacteria was expected to improve the viability of bididobacteria in fermented milk products and develop the high value-added products.

  • PDF

The Research about Checking Method of Governor Vessel's Acupoints at Lumbar Regions : (compared with X-ray measuring) (요부(腰部) 독맥경(督脈經)의 혈위(穴位) 결정방법(決定方法)에 관한 연구(硏究)(X-선상(線像)을 중심(中心)으로))

  • Choe, Ick-Seon
    • Journal of Acupuncture Research
    • /
    • v.17 no.4
    • /
    • pp.1-4
    • /
    • 2000
  • For checking the exact acupuncture points of Governor Vessel(GV) at lumbar regions, five kinds of method were used to 100 patients who have treated in outpatient in our hospital. They were attached distinguishable stainless steel by the methods. And those were compared with X-ray measuring. As a results, the best method to check Yoyang-gwan(GV3, Ya~oyanggua~n) was the way of using both iliac crests at lateral lying position.

  • PDF

The Development of Underwater Robotic System and Its application to Visual Inspection of Nuclear Reactor Internals (수중로봇 시스템의 개발과 원자로 압력용기 육안검사에의 적용)

  • 조병학;변승현;신창훈;양장범
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1327-1330
    • /
    • 2004
  • An underwater robotic system has been developed and applied to visual inspection of reactor vessel internals. The Korea Electric Power Robot for Visual Test (KeproVt) consists of an underwater robot, a vision processor-based measuring unit, a master control station and a servo control station. The robot guided by the control station with the measuring unit can be controlled to have any motion at any position in the reactor vessel with $\pm$1 cm positioning and $\pm$2 degrees heading accuracies with enough precision to inspect reactor internals. A simple and fast installation process is emphasized in the developed system. The developed robotic system was successfully deployed at the Younggwang Nuclear Unit 1 for the visual inspection of reactor internals.

  • PDF

A Study on Statistical Analysis of Local Ice Loads Measured during the Arctic Voyage of the IBRV ARAON

  • Kwon, Yong-Hyeon;Choi, Kyungsik;Lee, Tak-Kee
    • Journal of Advanced Research in Ocean Engineering
    • /
    • v.1 no.3
    • /
    • pp.186-197
    • /
    • 2015
  • In summer 2010, field measurements of local ice loads were carried out in the Arctic Ocean using the Korean first icebreaking research vessel, ARAON. In some previous studies by the authors, several investigations for the data measured at 2010 including the relationship between the measuring points and ice loads, the possibility for observation of higher ice load and the relationship between the ship speed and ice loads were reported. During 10 days in August 2013, new field measurements were performed in similar waters of the Arctic Ocean using the same vessel, ARAON. The aim of this study is to investigate the statistical properties of 2013 measurements and compare results by two periods.

A Study on the Fuzzy Controller for an Unmanned Surface Vessel Designed for Sea Probes

  • Park, Soo-Hong;Kim, Jong-Kwon;Lee, Won-Boo;Jang, Cheol-Soon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.586-589
    • /
    • 2005
  • Recently, the applications of unmanned system are steadily increasing. Unmanned automatic system is suitable for routine mission such as reconnaissance, environment monitoring, resource conservation and investigation. Especially, for the ocean environmental probe mission, many ocean engineers had scoped with the routine and even risky works. The unmanned surface vessel designed for sea probes can replace the periodic and routine missions such as water sampling, temperature and salinity measuring, etc. In this paper, an unmanned surface vessel was designed for ocean environmental probe missions. A classical and an adaptive fuzzy control system were designed and tested for the unmanned surface vessel. The design methodologies and performance of the surface vessel and fuzzy control algorithm were illustrated and verified with this unmanned vessel system designed for sea probes.

  • PDF

A Study on the Behavior of Liquid Free Surface in a Shaking Vessel (진동교반조에서의 액자유표면의 거동에 관한 연구)

  • Lee, Young-Sei;Kim, Moon-Gab
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.3 no.3
    • /
    • pp.209-217
    • /
    • 2000
  • An attempt has been made to examine the highest liquid surface by means of measuring the movement of liquid free surface wave in the agitated vessel wall. Also, Relationship has been investigated between transition frequency, $N_z$ for behavior of liquid free surface and transition frequency for behavior of mass transfer coefficient in the agitated vessel wall. A surface wave is occured within agitated vessel, the highest height of wetted vessel wall, $h_w$ is coincided with the highest liquid surface, h. However the lowest height of wetted vessel, $h^*{_w}$ is not descended to lowest liquid free surface, $h^*$. The proposed model has been tested sucessfully for the behavior of liquid free surface.

  • PDF

Horary System of the Early Chosen and the King Sejong′s Striking Clepsydra : (1) Water-Clocks (조선초기의 시제와 세종의 자격루:(1) 물시계)

  • 남문현;한득영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.697-701
    • /
    • 1996
  • King Sejong's Striking water-clock which brought in use on the first of July in 1434 was mainly composed of timekeeping and time announcing parts signalling twelve double-hours, and five night-watches and night-watch-divisions automatically by means of ball-operating jackworks. The clock was arranged with dual timekeeping system, the one for a full day(twelve double-hours) and the other for five night-watches achieving twelve double-hours and one-hundred interval horary systems. The vessels were arrayed in inflow-type water-clock, a large reservoir on the highest story, a constant-level tank for supplying water to the measuring vessel evenly in the middle, and the lowest tank to receive water from the above constant-level tank. An indicator-rod on the float was raised upwards depending on the water-level increase to show timing scales and also to release small bronze balls from the ball-rack mechanisms implanted on the measuring vessel to signal timing intervals.

  • PDF

Selection of Measuring Sensors for Reactor Vessel Internals Comprehensive Vibration Assessment Program in Advanced Power Reactor 1400 (APR1400 원자로 내부구조물 종합진동평가 측정센서 선정)

  • Ko, Do-Young;Lee, Jae-Gon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.433-438
    • /
    • 2010
  • Reactor vessel internals comprehensive vibration assessment program(RVI CVAP) is one of the necessary tests to ensure the safety of nuclear power plants. RVI CVAP of U.S. Nuclear Regulatory Commission Regulatory Guide 1.20(U.S. NRC R.G. 1.20) consists of the analysis, measurement, and inspection. One of the core technologies of the measurement program for RVI CVAP is to select suitable sensors. We analyzed RVI design data of Palo Verde nuclear generating station(U.S.) and Yonggwang nuclear generating station(Korea) and investigated measuring sensors used in both of them; moreover, we investigated sensors used for measurement of RVI CVAP for the last 20 years throughout the world. Based on these results, we selected the most suitable sensors for RVI CVAP in Advanced Power Reactor 1400(APR1400).

  • PDF

A Study on Accuracy Improvement in Measuring Liquid Level inside Pressurized Vessels (압력 용기 수위 측정 오차 개선에 관한 연구)

  • Kim, Ho-Yol;Byun, Seung-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.10
    • /
    • pp.1889-1893
    • /
    • 2010
  • Differential pressure type level measuring systems have been using widely for industrial applications like drum level measurements in power plants. Because of difficulties in specific gravity compensation for vapor and liquid inside the vessel and the sensing lines, this type of measuring systems reveal significant measuring error. In this paper, the major reason causing errors on the differential pressure type level measurement is analyzed and a method of more accurate calculation for specific gravity compensation is introduced.