• Title/Summary/Keyword: measuring tape

검색결과 100건 처리시간 0.024초

키네시오 테이핑요법이 월경전후기 불편감에 미치는 효과 (A Study on the Effects of the Kinesio Tape Method on Perimenstrual Discomforts)

  • 박경민;이성희;도은수
    • 지역사회간호학회지
    • /
    • 제14권3호
    • /
    • pp.415-423
    • /
    • 2003
  • Purpose: This study aims to examine whether the kinesio tape method can relax perimenstrual symptoms and decrease the menstrual pain of those who complain of perimenstrual discomforts. Method: This study has been designed to use the nonequivalent control group in the pre and post-test. The data have been collected from unmarried females complaining of perimenstrual discomfort and living in D city from the 2nd of February through the 10th of April, 2002. An experimental group of 32 people and a control group of 35 people were chosen, and they were first investigated for symptoms before and after menstruation when the menstrual pain was the severest and for the VAS measurement of menstrual pain. For the experimental group, the kinesio tape method was conducted two times a week for three weeks (six times in all), and the control group remained intact. The investigations after the experimental treatment were carried out in the same way as before. The measuring instruments were the peri menstrual measuring instruments of symptoms of 42 items and the menstrual pain was measured by VAS Result: The primary hypothesis: The experimental group who used the kinesio tape method would experience less perimenstrual discomfort than the control group who did not use it. The first sub-hypothesis: The first sub-hypothesis that suggests 'The experimental group who used the kinesio tape method would experience more relaxation of perimenstrual symptom than the control group who did not use it' was supported. The second sub-hypothesis: The second sub-hypothesis that suggests that 'The experimental group who used the kinesio tape method would get lower scores of menstrual pain of VAS than the control group who did not use it' was supported. Conclusion: These results of the study show that the kinesio tape method is effective in relaxing perimenstrual symptoms and lessening menstrual pain.

  • PDF

줄자를 이용한 하지부피 측정시 부위별 검사자간, 검사자내 신뢰도 측정 (Intertester and Intratester Reliability of Tape Measurement on Lower Extremities)

  • 김성중;양회송;이충휘
    • 한국전문물리치료학회지
    • /
    • 제7권1호
    • /
    • pp.38-45
    • /
    • 2000
  • Tape measurement for evaluating edema is frequently used by clinicians. The primary purpose of this study is to determine the intertester and intratester reliability of tape measurement carried out by two physical therapists on lower extremities. The intertester and intratester reliability of six anatomical landmarks measurements were determined in six healthy subjects. The measurements were taken in five sessions by each tester. The intraclass correlation coefficients (2,1) were between .87 and .99 for intertester reliability. Intratester reliability was .93 and .99 for A tester and .82 and .99 for B tester. The average range of variation was .13 to .54 in six landmarks. The reliability of six volume measurements was very high. These results support the use tape measurement as a reliable tool for measuring limb girth.

  • PDF

A Tape Feeder Inspection System for Measuring Feeding Accuracy

  • Cho, Tai-Hoon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.98.4-98
    • /
    • 2001
  • A tape feeder of a SMD(Surface Mount Device) mounter is a device that sequentially feeds electronic components on a tape reel to the pick-up system of the mounter. As components are getting much smaller, feeding accuracy of a feeder becomes one of the most important factors for successful component pick-up. Therefore, it is critical to keep the feeding accuracy to a specified level in the assembly and production of tape feeders. This paper describes a tape feeder inspection system that was developed to automatically measure and inspect feeding accuracy using machine vision. It consists of a feeder base, an image acquisition system, and a personal computer. The image acquisition system is composed of CCD cameras with lens ...

  • PDF

테이프 피더의 부품공급 정밀도 측정을 위한 검사 시스템 (An Inspection System for Measuring Feeding Accuracy of Tape Feeders)

  • 조태훈;이성준
    • 제어로봇시스템학회논문지
    • /
    • 제8권7호
    • /
    • pp.573-577
    • /
    • 2002
  • A tape feeder of a SMD(Surface Mount Device) mounter is a device that sequentially feeds electronic components on a tape reel to the pick-up system of the mounter. As components are getting much smaller, feeding accuracy of a feeder becomes one of the most important factors for successful component pick-up. Therefore, it is critical to keep the feeding accuracy to a specified level in the assembly and production of tape feeders. This paper describes a tape feeder inspection system that was developed to automatically measure and inspect feeding accuracy using machine vision. It consists of a feeder base, an image acquisition system, and a personal computer. The image acquisition system is composed of CCD cameras with lens, LED illumination systems, and a frame grabber inside the PC. This system loads up to six feeders at a time and inspects them automatically and sequentially. The inspection software was implemented using Visual C++on Windows NT with easily usable GUI. Using this system, we can automatically measure and inspect the quality of all feeders in production process by analyzing the measurement results statistically.

자장방향이 적층 Bi-2223도체의 자화손실에 미치는 영향 (Effect of Field Orientation on Magnetization Loss in a Stacked Bi-2223 Conductor)

  • 류경우;김현준
    • 한국전기전자재료학회논문지
    • /
    • 제16권1호
    • /
    • pp.77-82
    • /
    • 2003
  • The ac loss is an important issue in the design of high-Tc superconducting power devices such as transformers and cables. In these devices many Bi-2223 tapes are closely stacked together and exposed to alternating magnetic fields that can have different orientations with respect to a tape. In such arrangement the magnetization loss is influenced by the screening current induced in adjacent tapes and thus different from that in a single tape. This stacking effect was experimentally investigated by measuring the magnetization loss in a stack, which consists of a number of tapes. First the magnetization loss in the single tape was measured in order to confirm the reliability of the loss data measured in the stack. The results for the single tape coincide well will the loss characteristics described in other previous works. For the stack In parallel and longitudinal magnetic fields the measured loss is Independent of both the number of tapes and stacking type. The longitudinal magnetization loss Is well explained rather by the slab model for decoupled filaments. For the tall stack in perpendicular field the measured loss at low fields is greatly decreased, compared to the loss of the single tape. However the loss at high fields is unaffected. These loss behaviors in the tall stack are well described by the slab model for full coupling.

VCR 주행장치의 2축 플랜지 반력 측정장치 개발 (Two-Axis Force Rransducer for Measuring Flange Reaction Forces in the Tape Transport of VCR)

  • 주진원;김승환;김갑순;이경원
    • 대한기계학회논문집A
    • /
    • 제20권7호
    • /
    • pp.2213-2222
    • /
    • 1996
  • This paper presents the design process and evaluaation results of a two-axis force transducer for measuring flange reaction forces. A double-cantilever beam structure is used as a sensing element, and its optimal configuration is determined based on the derived strain equations to maximize the sensitivity and minimize the regid body displacements. To reduce the coupling errors between two-axis forces, strain distributions by finite elemetns analysis are utilized and the Wheaststone bridge cricuits composed of strain gages are built such that the output voltage should be zero, although strains of four strain gages are not zero. Calibration test shows that the two-azxis force transducer developed in this paper is useful in measuring flange reaction forces within the coupling error of 5.53%.

전류분포가 3본-도체의 임계전류/교류손실 특성에 미치는 영향 (Influence of Current Distributions on Critical Current and AC Loss Characteristics in a 3-conductor)

  • 류경우;최병주
    • 한국전기전자재료학회논문지
    • /
    • 제16권5호
    • /
    • pp.418-423
    • /
    • 2003
  • AC loss is an important issue in the design of high-T$\sub$c/ superconducting power cables which consist of a number of Bi-2223 tapes wound on a former. In the cables, the tapes have different critical currents intrinsically. And they are electrically connected to each other and current leads. These make loss measurements considerably complex, especially for short samples of laboratory size. So special cautions are required in the positioning of voltage leads for measuring the true loss voltage. In this work we have prepared a conductor composed of three Bi-2223 tapes with different critical currents. The critical current and AC loss characteristics in the conductor have experimentally investigated. The results show that for uniform current distributions the conductor's critical current is proportional to the critical current of the Bi-2223 tape to which a voltage lead is attached. However it depends on the current non-uniformity parameter in the conductor rather than the tape's critical currents for nonuniform current distributions. The loss tests indicate that the AC loss is dependent on arrangements of voltage leads but not on their contact positions. The measured losses in the conductor also agree well with the sum of the transport losses measured in each Bi-2223 tape.

맥진 깊이 판단을 위한 실시간 압력 측정기 (Real-Time Pressure-Measuring System for Evaluating the Depth of Pulse)

  • 조정호;김대복;김기왕
    • 동의생리병리학회지
    • /
    • 제27권3호
    • /
    • pp.313-317
    • /
    • 2013
  • In order to standardize the pressure/depth against radial artery, the externally-applied-pressure measuring system was fabricated and evaluated. Based on the resistance-variable characteristic of the very thin($10{\mu}m$) film conductive tape along the pressure of a tip of a examiner's hand, this system was designed. The change of the pressure was processed through voltage regulator and Matlab S/W, then showed on computer monitor. The signal output through voltage regulator, and Matlab S/W was evaluated on various conditions. The evaluation was executed on these cases; an examiner slowly increases and decreases the pressure, rapidly increases and decreases the pressure, sequentially increases and decreases the pressure, sustains the pressure, micro-changes the pressure. As a pulse examiner varies the pressure on the radial artery of the examinee, the system's real-time output consistently varies according to the pressure. From the results, it is concluded that this system consistently shows the pressure of the tip of a examiner's hand in real time without interrupting the evaluation of the radial artery pulse. Therefore this system is expected to standardize the value of the pressure/depth externally applied by an examiner.

스캐닝 홀 프로브 측정 시스템의 데이터 측정 위치 표시 기술 (position marking technique for data measured in a scanning hall probe system)

  • 유재은;이재영;정예현;이상무;염도준
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제9권3호
    • /
    • pp.13-15
    • /
    • 2007
  • We employed home-made position marking module in the scanning Hall probe system. The module is composed of two coils of which gap, a, between wires in a coil is $500{\mu}m$. We appiled 10-35mA of current with 15Hz in the coils and recorded ac corresponding magnetic field signal with respect to measuring time while we measured DC field profiles produced due to superconducting film in a perpendicular magnetic field. We calibrate the position, x, of coils using the measuring time and location of the coils in the holder. The error range was about ${\pm}0.1mm$. We test the module as we applied current of 100A and filed of 1kG in the superconducting tape. It was confirmed that there was no interference between superconducting tape and marking coils.