• 제목/요약/키워드: measurement technique

검색결과 4,390건 처리시간 0.036초

초기 재령 콘크리트의 모니터링을 위한 개선된 레일리파 속도 측정 기법 (Improved Rayleigh Wave Velocity Measurement Technique for Early-age Concrete Monitoring)

  • 신성우;윤정방;;송원준
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2006년도 정기 학술대회 논문집
    • /
    • pp.97-103
    • /
    • 2006
  • A modified one-sided measurement technique is proposed for Rayleigh wave (R-wave) velocity measurement in concrete. The scattering from heterogeneity may affect the waveforms of R-waves in concrete, which may make the R-waves dispersive. Conventional one-sided techniques do not consider the scattering dispersion of R-waves in concrete. In this study, the maximum energy arrival concept is adopted to determine the wave velocity by employing its continuous wavelet transform. Experimental study was performed to show the effectiveness of the proposed method. The present method is applied to monitor the strength development of early-age concrete. A series of experiments were performed on early-age concrete specimens with various curing conditions. Results reveal that the proposed method can be effectively used to measure the R-wave velocity in concrete structures and to monitor the strength development of early-age concrete.

  • PDF

비구면 렌즈의 형상 측정을 위한 접촉식 프로브 기술 개발 (Contact Probing Technique for Profile Measurement of Aspheric Lenses)

  • 유승봉;장인철;김승우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 춘계학술대회 논문집
    • /
    • pp.603-606
    • /
    • 2000
  • This dissertation is concerned with ultra-precision profile measurement of aspheric surfaces using contact probing technique. A contact probe has been designed as a sensing device to obtain measuring resolutions in nanometer regime utilizing a leaf spring mechanism and a capacitive-type sensor. The contact probe is attached on the z-axis during measurement while aspheric objects are supported on an precision xy-stage whose lateral motions are monitored by a set of two orthogonal plane mirror type laser interferometers. Experimental results show that the contact probing technique developed in this investigation is capable of providing a repeatability of 50 nanometers with a $\pm$3$\sigma$ uncertainty of 300 nanometers. Thermal disturbance is found the most significant factor that should be precisely controlled for accurate measurement.

  • PDF

세포외 분비시 막 캐패시턴스를 측정하기 위한 위상감지법(phase detector technique)의 이론적 분석. (Theoretical Analysis of Phase Detector Technique for the Measurement of Cell Membrane Capacitance During Exocytosis)

  • Cha, Eun-Jong;Goo, Yong-Sook;Lee, Tae-Soo
    • 한국의학물리학회지:의학물리
    • /
    • 제3권2호
    • /
    • pp.43-57
    • /
    • 1992
  • 위상감지법(phase detector technique)은 세포의 막 캐패시턴스(membrane capacitance)를 실시간적으로 측정할 수 있는 유일한 방법이나 측정이 행해지는 동안 세포의 상태가 끊임없이 변화하기 때문에 피할 수 없는 측정오차가 존재한다. 본 연구는 이 오차의 근원을 분석하여 위상감지법의 실용한계를 규정하고자 하였다. 이론적 분석에 기초하여 다음과 같은 사실을 밝힐 수 있었다. 1) access conductance와 membrane conductance의 변화에 기인하는 측정오차를 줄이기 위해서는 초기 위상치를 올바로 선택하여야 한다. 2) 이 때 세포를 여기시키기 위해 인가하는 전압의 주파수를 알맞게 선택하여야 한다. 3) 그러나 초기 위상치가 정해진 이후의 위상 변화는 막 캐패시턴스의 측정에 큰 영향을 미치지 않는다. 4) 초기 위상을 적절히 선택하였다 하더라도 세포외 분비시 막 캐패시턴스가 크게 증가하는 경우에는 비례상수에 오차가 발생한다. 이 때 발생하는 오차는 측정기간 동안 비례상수를 되풀이하여(iteration) 보정함으로써 방지할 수 있다. 이상의 결과는 향후 위상감지법을 사용할 때 유용한 설용한계를 제공하리라 생각된다.

  • PDF

Development of Camera-Based Measurement System for Crane Spreader Position using Foggy-degraded Image Restoration Technique

  • Kim, Young-Bok
    • 한국항해항만학회지
    • /
    • 제35권4호
    • /
    • pp.317-321
    • /
    • 2011
  • In this paper, a foggy-degraded image restoration technique with a physics-based degradation model is proposed for the measurement system. When the degradation model is used for the image restoration, its parameters and a distance from the spreader to the camera have to be previously known. In the proposed image restoration technique, the parameters are estimated from variances and averages of intensities on two foggy-degraded landmark images taken at different distances. Foggy-degraded images can be restored with the estimated parameters and the distance measured by the measurement system. On the basis of the experimental results, the performance of the proposed foggy-degraded image restoration technique was verified.

PIV 기법과 Digital Mask 기법을 적용한 버블유동 측정 (The Measurement of Bubble Driven Flow Using PIV and Digital Mask Technique)

  • 김상문;김현동;김경천
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2700-2703
    • /
    • 2008
  • An experiment on bubble-driven flow was performed in order to understand fundamental knowledge of flow structure around a rising bubble in a stagnant fluid. The measurement technique consists of a combination of the three most often used PIV techniques in multiphase flows: PIV with fluorescent tracer particles, the digital phase separation with a masking technique and a shadowgraphy. The key point of the measurement is that the background intensity of a PIV recording can be shifted to a higher level than a bubble region using a shadowgraphy in order to distinguish from fluorescent particles and a bubble as well. Flow fields were measured without an inaccurate analysis around a fluid-bubble interface by using only one camera simply.

  • PDF

A Study on the Difference Method of Magnetic Resonance Signal Measurement when Using Multi-channel Coil and Parallel Imaging

  • Choi, Kwan-Woo;Lee, Ho-Beom;Son, Soon-Yong;Jeong, Mi-Ae
    • Journal of Magnetics
    • /
    • 제22권2호
    • /
    • pp.220-226
    • /
    • 2017
  • SNR (signal to ratio) is a criterion for providing objective information for evaluating the performance of a magnetic resonance imaging device, and is an important measurement standard for evaluating the quality of MR (Magnetic Resonance) image. The purpose of our study is to evaluate the correct SNR measurement for multi-channel coil and parallel imaging. As a result of research, we found that both T1 and T2 weighted images show the narrowest confidence interval of the method recommended by NEMA (The National Electrical manufacturers Association) 1 having a single measurement method, whereas the ACR (American College of Radiology) measurement method using a multi-channel coil and a parallel imaging technique shows the widest confidence interval. There is a significance in that we quantitatively verified the inaccurate problems of a signal to noise ratio using a ACR measurement method when using a multi-channel coil and a parallel imaging technique of which method does not satisfy the preconditions that researchers could overlook.

바이패스 스위치와 저항센서를 이용한 저손실 전류 측정방법 (Low Power-loss Current Measurement Technique Using Resistive Sensor and Bypass Switch)

  • 이화석;다니엘;박종후
    • 전력전자학회논문지
    • /
    • 제17권5호
    • /
    • pp.416-422
    • /
    • 2012
  • This paper proposes a low power-loss current measurement using a resistor and bypass switch. Conventional current sensing method using a resistor has a disadvantage of power loss which degrades the efficiency of the entire systems. On the other hand, proposed measurement technique operating with bypass-switch connected in parallel with sensing resistor can reduce power loss significantly the current sensor. The propose measurement works for discrete-time sampling of current sensing. Even while the analog-digital conversion does not occur at the controller, the sensing voltage across the sensor still causes ohmic conduction loss without information delivery. Hence, the bypass switch bypasses the sensing current with a small amount of power loss. In this paper, a 90[W] prototype hardware has been implemented for photovoltaic MPPT experimental verification of the proposed low power-loss current measurement technique. From the results, it can be seen that PV power observation is successfully done with the proposed method.

Exploration of temperature effect on videogrammetric technique for displacement monitoring

  • Zhou, Hua-Fei;Lu, Lin-Jun;Li, Zhao-Yi;Ni, Yi-Qing
    • Smart Structures and Systems
    • /
    • 제25권2호
    • /
    • pp.135-153
    • /
    • 2020
  • There has been a sustained interest towards the non-contact structural displacement measurement by means of videogrammetric technique. On the way forward, one of the major concerns is the spurious image drift induced by temperature variation. This study therefore carries out an investigation into the temperature effect of videogrammetric technique, focusing on the exploration of the mechanism behind the temperature effect and the elimination of the temperature-caused measurement error. 2D videogrammetric measurement tests under monotonic or cyclic temperature variation are first performed. Features of measurement error and the casual relationship between temperature variation and measurement error are then studied. The variation of the temperature of digital camera is identified as the main cause of measurement error. An excellent linear relationship between them is revealed. After that, camera parameters are extracted from the mapping between world coordinates and pixels coordinates of the calibration targets. The coordinates of principle point and focal lengths show variations well correlated with temperature variation. The measurement error is thought to be an outcome mainly attributed to the variation of the coordinates of principle point. An approach for eliminating temperature-caused measurement error is finally proposed. Correlation models between camera parameters and temperature are formulated. Thereby, camera parameters under different temperature conditions can be predicted and the camera projective matrix can be updated accordingly. By reconstructing the world coordinates with the updated camera projective matrix, the temperature-caused measurement error is eliminated. A satisfactory performance has been achieved by the proposed approach in eliminating the temperature-caused measurement error.

Enhancement of Tracking Performance of Laser Tracking System for Measuring Position Accuracy of Robots

  • Hwang, Sung-Ho;Choi, Gyeong-Rak;Lee, Ho-Gil;Shon, Woong-Hee;Kim, Jin-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.61.5-61
    • /
    • 2001
  • The laser tracking system(LTS) presents the most promising technique for dynamic position measurement of industrial robots. This system combine the advantage of high accuracy with a contactless measurement technique. It is the measurement system of position in three dimensions using distance data obtained by laser interferometer and real time angle by tracking mirror assembly. After measuring the tracking error of the beam projected on the center of retroreflector in robot end effector, this system tracks the end effector continuously by adjusting tracking mirror angle to minimize this error ...

  • PDF

A Technique and software of analysis and control for measurement process

  • Zhao, Fengyu;Xu, Jichao;Bergman, Bo
    • International Journal of Quality Innovation
    • /
    • 제1권1호
    • /
    • pp.97-105
    • /
    • 2000
  • In this paper, a two-section method for measuring is introduced and the variation sources of measurement process are analysed. Measuring is a special process in general process. Various variation source must be firstly decomposed so that the statistical distribution law of measuring process can be established, and then implement monitoring control of the measuring process. A special method to obtain the measuring variation is discussed, and a monitoring control technique for measuring process is studied based statistical distribution. Towards the end, we briefly introduce software design for the analysis and control of a measurement process.

  • PDF