• Title/Summary/Keyword: measurement systems

Search Result 4,930, Processing Time 0.036 seconds

The Implementation of Embedded Web Server System for a Remote Control and Measurement (원격 제어 및 계측을 위한 임베디드 웹 서버 시스템 구현)

  • Lee, Myung-Eui
    • Journal of Advanced Navigation Technology
    • /
    • v.16 no.5
    • /
    • pp.839-845
    • /
    • 2012
  • This paper deals with the design and development of the remote control and measurement systems by Embedded Web Server. The remote control and measurement systems are implemented by Cortex M-3 ARM micro-controller. The user application software for the control and measurement system user, and the firmware software of device drivers for peripherals such as a digital input/output device, AD/DAC(Analog to Digital/Digital to Analog Converter), LCD, and temperature/humidity sensor are developed in Eclipse environment using Codesourcery C, Java script, and HTML. The experimental result of the proposed control and measurement systems implemented in this paper is evaluated via real-time experiments, which works well as designed.

Real-Time Monitoring and Analysis of Power Systems with Synchronized Phasor Measurements

  • Kim, Hong-Rae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.9
    • /
    • pp.101-108
    • /
    • 2007
  • State estimators are used to monitor the operating states of power systems in modern EMS. It iteratively calculates the voltage profile of the currently operating power system with voltage, current, and power measurements gathered from the entire system. All the measurements are usually assumed to be obtained simultaneously. It is practically impossible, however, to maintain the synchronism of the measurement data. Recently, phasor measurements synchronized via satellite are used for the operation of these power systems. This paper describes the modified state estimator used to support the processing of synchronized phasor measurements. Synchronized phasor measurements are found to provide synchronism of measurement data and improve the accuracy/redundancy of the measurement data for state estimation. The details of the developed state estimation program and some numerical results of operation are presented.

Relative Measurement of Differential Electrode Impedance for Contact Monitoring in a Biopotential Amplifier

  • Yoo, Sun-K.
    • International Journal of Control, Automation, and Systems
    • /
    • v.5 no.5
    • /
    • pp.601-605
    • /
    • 2007
  • In this paper, we propose a simple and relative electrode contact monitoring method. By exploiting the power line interference, which is regarded as one of the worst noise sources for bio-potential measurement, the relative difference in electrode impedance can be measured without a current or voltage source. Substantial benefits, including no extra circuit components, no degradation of the body potential driving circuit, and no electrical safety problem, can be achieved using this method. Furthermore, this method can be applied to multi-channel isolated bio-potential measurement systems and home health care devices under a steady measuring environment.

An Exploratory Study on Developing SCM Performance Measurements in Small and Medium Enterprises (중소기업 SCM 성과측정지표 개발에 관한 탐색적 연구)

  • Kim, Jin-Soo;Kim, Dae-Jin
    • The Journal of Information Systems
    • /
    • v.13 no.2
    • /
    • pp.195-226
    • /
    • 2004
  • SCM becomes the key information systems in small and medium enterprises followed by ERP. One of the critical success factors for successful implementation of SCM is to develop a performance measurement framework. Previous study, however, shows that there are not appropriate performance measurements for small and medium enterprises. The purpose of this study is to develop a SCM performance measurement for small and medium enterprises. Based on the analysis of previous studies, a performance framework and measurement are developed. A case study has been conducted to validate a framework. The results show that a framework is valid, but needs to be improved. Using a framework, more successful implementation of SCM would be expected.

  • PDF

A Statistical Program for Measurement Process Capability Analysis based on KS Q ISO 22514-7 Using R (R을 이용한 KS Q ISO 22514-7 측정 프로세스 능력 분석용 프로그램)

  • Lee, Seung-Hoon;Lim, Keun
    • Journal of Korean Society for Quality Management
    • /
    • v.47 no.4
    • /
    • pp.713-723
    • /
    • 2019
  • Purpose: The purpose of this study is to develop a statistical program for capability analysis of measuring system and measurement process based upon KS Q ISO 22514-7. Methods: R is a powerful open source functional programming language that provides high level graphics and interfaces to other languages. Therefore, in this study, we will develop the statistical program using R language. Results: The R program developed in this study consists of the following five modules. ① Measuring system capability analysis with Type 1 study data: MSCA_Type1.R ② Measuring system capability analysis with Linearity study(Type 4 study) data: MSCA_Type4.R ③ Measurement process capability analysis with Type 1 study & Gage R&R study data: MPCA_T1GRR.R ④ Measurement process capability analysis with Type 4 study & Gage R&R study data: MPCA_T4GRR.R ⑤ Attribute measurement processes capability analysis : AttributeMP.R Conclusion: KS Q ISO 22514-7 evaluates measuring systems and measurement processes on the basis of the measurement uncertainty that was determined according to the GUM(KS Q ISO/IEC Guide 98-3). KS Q ISO 22514-7 offers precise procedures, however, computations are more intensive. The R program of this study will help to evaluate the measurement process.

A Study on the Measurement of Delivery Flow Ripple Generated by Hydraulic Axial Piston Pumps (유압용 액셜 피스톤 펌프의 유량맥동 계측에 관한 연구)

  • 이상기
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.8 no.2
    • /
    • pp.35-43
    • /
    • 1999
  • The paper describes an approach for measuring delivery flow ripple generated by oil hydraulic axial piston pumps. In order to reduce pressure ripple which cause to undesirable noise. vibration and fatigue in hydraulic systems it is indispensible measure a delivery flow ripple from pumps. Since the flow ripple measurement of flow pumps is independent of the dynamic characteristics of the connected hydraulic circuit the measurement of flow ripple is most suitable for pump fluid-borne noise rating. The measurement of flow ripple with high frequencies from axial piston pumps is made by applying the remote instantaneous flow rate measurement method which is based on the dynamic characteristics between pressure and flow rate in hydraulic pipeline. The measured flow ripple waveforms are influenced by the configuration of V-shaped triangular relief groove in the valve plate. It can be seen that the appropriate relief groove in valve plate reduces the pressure and flow ripple amplitude and frequency spectrum for high harmonics.

  • PDF

Development of Automatic Measurement and Inspection System for ALC Block Using Camera (카메라를 이용한 ALC 블록의 치수계측 및 불량검사 자동화 시스템 개발)

  • 허경무;김성훈
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.6
    • /
    • pp.448-455
    • /
    • 2003
  • A system design technique of automatic thickness measurement and defect inspection system, which measures the thickness of the ALC(Autoclaved Lightweight Concrete) block and inspects the defect on a realtime basis is proposed. The image processing system was established with a CCD camera, an image grabber, and a personal computer without using assembled measurement equipment. The image obtained by this system was analyzed by a devised algorithm, specially designed for the enhanced measurement accuracy. For the realization of the proposed algorithm, the preprocessing method that can be applied to overcome uneven lighting environment, an enhanced edge decision method using 8 edge-pairs with irregular and rough surface, the unit length decision method in uneven condition with rocking objects, and the curvature calibration method of camera using a constructed grid are developed. The experimental results, show that the required measurement accuracy specification is sufficiently satisfied using our proposed method.

The Development of Automatic Measurement Algorithm of Concentricity and Roundness using Image Processing Technique (이미지 프로세싱을 이용한 가공 물체의 동심도와 진원도 자동 측정 알고리즘 개발)

  • 허경무;문형욱
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.3
    • /
    • pp.227-235
    • /
    • 2003
  • We propose an algorithm for the automatic measurement of concentricity and roundness using image processing technique. The proposed measuring method consists of the preprocessing process and the measuring process. In the measuring process, two types of concentricity measurement algorithm and one type of roundness measurement algorithm are proposed. We could measure the concentricity and roundness using input image from CCD camera, without using special measurement equipment. From the experimental results, we could find that the required measurement accuracy specification is sufficiently satisfied using our proposed method.

Measurement of thermal contact resistance at Cu-Cu interface

  • Kim, Myung Su;Choi, Yeon Suk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.2
    • /
    • pp.48-51
    • /
    • 2013
  • The thermal contact resistance (TCR) is one of the important components in the cryogenic systems. Especially, cryogenic measurement devices using a cryocooler can be affected by TCR because the systems have to consist of several metal components in contact with each other for heat transferring to the specimen without cryogen. Therefore, accurate measurement and understanding of TCR is necessary for the design of cryogenic measurement device using a cryocooler. The TCR occurs at the interface between metals and it can be affected by variable factors, such as roughness of metal surface, contact area and contact pressure. In this study, we designed TCR measurement system at various temperatures using a cryocooler as a heat sink and used steady state method to measure the TCR between metals. The copper is selected as a specimen in the experiment because it is widely used as a heat transfer medium in the cryogenic measurement devices. The TCR between Cu and Cu is measured for various temperatures and contact pressures. The effect of the interfacial materials on the TCR is also investigated.

Measurement of error estimation for velocity-aided SDINS using separate-bias Kalman filter (바이어스 분리 칼만필터를 이용한 속도보정 SDINS의 측정오차 추정)

  • Jeon, Chang-Bae;Lyou, Joon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.4 no.1
    • /
    • pp.56-61
    • /
    • 1998
  • The velocity measurement error in the velocity-aided SDINS on the maneuvering vehicle is unavoidable and degrades the performance of the SDINS. The characteristics of the velocity measurement error can be modeled as a random bias. This paper proposes a new method for estimating the velocity measurement error in the SDINS. The generalized likelihood ratio test is used for detecting the error and a modified separate-bias Kalman filter in the feedback configuration is suggested for estimating the magnitude of the velocity measurement error.

  • PDF