• Title/Summary/Keyword: measurement systems

Search Result 4,952, Processing Time 0.035 seconds

Bad Data Detection Method in Power System State Estimation (전력계통 상태주정에서의 불량정보 검출기법)

  • 최상봉;문영현
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.2
    • /
    • pp.144-153
    • /
    • 1991
  • This paper presents an algorithm to improve accuracy and reliability in the state estimation of contaminated bad data. The conventional algorithms for detection of bad data have the problems of excessive memory requirements and long computation time. In order to overcome these problems, a measurement compensation approach is proposed to reduce computation time, and the partitioned measurement error model has the advantage of remarkable reduction in computation time and memory requirements in estimated error computation. The proposed algorithm has been tested for IEEE sample systems, which shows its applicability to on-line power systems.

Development of robot work measurement by the unit motion model (단위 동작 모형에 따른 로봇 작업시간 측정법의 개발)

  • 권규식
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.367-370
    • /
    • 1996
  • This study deals with the motion modeling by the unit motion of robots and the work measurement through classification of robot motions and standardization. The proposed approach is to scrutinize the Predetermined Time Standards(PTS) methods for measurement of manual tasks performed by people and the basic motions for accomplishing that tasks. And then, it constructs the unit motion models as subsets composed with the basic motions. It apply together with movements distance as a time variable, too. These results are used for the work measurements of robots by the unit motion models.

  • PDF

Development of automatic measurement system for dynamic respose time of pneumatic solenoid valve (공압밸브의 동적응답 특성측정 자동화 시스템 개발)

  • 강보식;김형의
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.974-978
    • /
    • 1991
  • Electro-pneumatic valve is an electro-mechanical device which converts electric signal into pneumatic flow mu or pressure. A measurement of dynamic response time is very important to evaluate valve performance. Dynamic response time of electro-pneumatic valve has a variation accordance with valve types, operating way and test standard. In this study, automatic measurement system of dynamic response time is composed based on test condition of dynamic response time test standard(CETOP, JIS). Also, in this study test pressure variation characteristics accordance with variation of solenoid excitation power, and we developed dynamic response measurement system enable to compare of and analyze these two characteristics.

  • PDF

A study on the detection threshold for multitarget tracking (다중표적 추적을 위한 표적 탐지 임계값에 대한 연구)

  • 이양원;이봉기;김광태;김경기
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10a
    • /
    • pp.834-838
    • /
    • 1992
  • Tracking performance depends on the quantity of the measurement data. In the Kalman-Bucy filter and other trackers, this dependence is well understood in terms of the measurement noise covariance matrix, which specifies the uncertainty in the value of measurement inputs. In this paper, we derived approximated error covariance matrix to evaluate the dependence of target detection probability and false alarm probability in the presence of uncertainty of measurement origin.

  • PDF

Development of Management System for Measurement and Characteristic analysis, Evaluation of Environmental Noise (인터넷 통신이용 실시간 환경소음 측정 및 특성분석, 평가ㆍ관리 시스템 개발)

  • 유동준;이상권
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.515-520
    • /
    • 2003
  • In these days, the civil appeal and dispute about environmental noise grows larger every year. But there are not suitable systems for measurement and management of environmental noise. This paper proposes environmental noise measurement, characteristic analysis and evaluation, management system using Internet. We can measure and manage the environmental noise also, analyze characteristics of noise by the environmental noise management system using Internet.

  • PDF

The Automated Measurement of Tool Wear using Computer Vision (컴퓨터 비젼에 의한 공구마모의 자동계측)

  • Song, Jun-Yeop;Lee, Jae-Jong;Park, Hwa-Yeong
    • 한국기계연구소 소보
    • /
    • s.19
    • /
    • pp.69-79
    • /
    • 1989
  • Cutting tool life monitoring is a critical element needed for designing unmanned machining systems. This paper describes a tool wear measurement system using computer vision which repeatedly measures flank and crater wear of a single point cutting tool. This direct tool wear measurement method is based on an interactive procedure utilizing a image processor and multi-vision sensors. A measurement software calcultes 7 parameters to characterize flank and crater wear. Performance test revealed that the computer vision technique provides precise, absolute tool-wear quantification and reduces human maesurement errors.

  • PDF

A Study on the Work Measurement Errors of the Continuous and the Divisions Observation (연속관측과 분할관측의 작업측정 오차에 관한 연구)

  • 김복만
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.6 no.9
    • /
    • pp.35-38
    • /
    • 1983
  • In this paper major subject is to investigate the measurement errors affecting on the determination of observation numbers, which are required for work measurement, to set up the standard work time. The main consider is, however, with clarification of the differences between measurement errors in case of cycle operation being observed based on the continuous and the work elements observation.

  • PDF

Measurement and Scale Effects of Digitized Virtual Human Head

  • Takakazu, Ishimatsu;Chan, Tony
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.89.1-89
    • /
    • 2001
  • Measurement of complex surfaces without touching is desirable in several fields. This arises mainly for measurement of complex surfaces including those surfaces that deform during touch. Our research presented in this paper describes the use of a 3D digitizer for scanning 3D objects. The use of such a device, in addition to proper calibration, requires proper scaling in all three dimensions. We propose measurement techniques to measure various aspects of the surface circumference, area and volume. We also present experiments from using a 3D Minolta digitizer for measuring 3D human heads.

  • PDF

Luminance Correction Algorithm Based on Measuring Angle for the Portable Luminance Measurement System (휴대용 휘도측정시스템의 측정각도기반 휘도보정알고리즘)

  • Sun, Eun-Hey;Kim, Dongyeon;Kim, Yong-Tae
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.26 no.4
    • /
    • pp.321-326
    • /
    • 2016
  • In this paper, we propose a luminance correction algorithm based on measuring position for potable luminance measurement system. Measurement position and angle have an affect on the luminance value. We improve the position-based luminance measurement system using luminance correction algorithm based on the measuring angle. We analyze change of luminance value according to the measurement distance and angle from camera and light source. The certified point-luminance meter is used to evaluate a scene luminance measuring method using the image information of camera. Also, we derive an expression equation for evaluating luminance value from determined position. The performances of the proposed system are verified by using comparative experiments with the point-luminance meter using experimental signboard.

Development of Drying Systems for Accurate Measurement of Particulate Matter by means of Optical Particle Measuring Instruments (광산란 계측기의 미세먼지 측정 정확도 향상을 위한 수분제거 전처리 기술 개발)

  • Kang, Doo Soo;Oh, Jung Eun;Lee, Sang Yul;Shin, Hee Joon;Bong, Ha Kyung;Choi, Joohyun;Kim, Dae Seong
    • Particle and aerosol research
    • /
    • v.14 no.4
    • /
    • pp.191-203
    • /
    • 2018
  • IIn this study, we have developed drying systems for reducing the error by humidity on measuring particulate matter (PM) in the ambient air with optical particle measuring instruments. Two types of drying systems were designed: drying systems using heating and dilution methods. In addition, 3 types of drying systems using a heating method were designed: Type A (1 hole), B (3 holes) and C (7 holes). After making them, the laboratory and field tests were carried out to evaluate the developed drying systems. As a result, it was shown that the PM concentrations obtained by PM monitoring devices with drying systems agree well with that of the reference devices. Therefore, it could be concluded that the drying systems can be applied to PM monitoring devices for real-time monitoring of the ambient aerosols.