• 제목/요약/키워드: measurement system

검색결과 14,640건 처리시간 0.044초

실시간 계통제어를 위한 동기위상측정장치 개발 (The development of synchronized phasor measurement device for real time power system control)

  • 전진홍;김학만;전영환;국경수;김지원;오태규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.85-87
    • /
    • 2000
  • In real-time power system control, it is essential to measure the power system variables which are voltage. current, real and reactive power, power factor, system frequency and etc. this variables can be estimated or calculated by the synchronized phasor informations of voltage and current. Therefore, the synchronized phasor measurement of voltage and current is very important to real-time power system control. So, we develop SPMD(Synchronized Phasor Measurement Device) for synchronized phasor measurement of voltage and current. In this paper, we present the design and implementation of SPMD for real-time phasor measurement and prove its performance by the test results.

  • PDF

나노인프로세스 표면형상계측을 위한 SFM시스템의 개발 (Development of SFM System for Nano In-Process Profile Measurement)

  • 권현규;최성대;홍성욱
    • 한국기계가공학회지
    • /
    • 제3권2호
    • /
    • pp.53-59
    • /
    • 2004
  • In this paper, we propose a new multi-purpose Scanning Force Microscope (SFM) system. The system can be used for nano/micro-scratching, in-process profile measurement, and observation of potential surface defects which occur during the scratching in air or liquid. Experimental results of nano/micro-scratching show that the smallest scratching depth can be controlled to be 10nm, which corresponds to the stability of the SFM system. Profile measurements of nano/micro-scratching surfaces have also been performed by the method of on-machine measurement and in-process measurement. Two measurement results were in good agreement with each other. The maximum difference was approximately 10 nm, which was mainly caused by the sampling repeatability error that influences the measurement accuracy Also, micro-defects on the micro-scratching surface were successfully detected by the SFM system. It was confirmed that the number of micro-defects increases when the surface is subjected to a cyclic bending load. The maximum depth was less than 100nm.

  • PDF

Bluetooth 모듈을 이용한 KWP2000 차량 ECU신호의 원격 계측 (Remote Measurement of the Automobile′s ECU Signals with KWP2000 using Bluetooth Module)

  • 최광훈;권대규;이성철
    • 한국정밀공학회지
    • /
    • 제21권10호
    • /
    • pp.86-93
    • /
    • 2004
  • This paper presents the remote measurement of the ECU signals adopted with KWP 2000 protocol using the wireless communication technique of bluetooth. The bluetooth technology will be the most promising network paradigm which can open the new area in the information technology. Especially, bluetooth module is able to link all the electrical products and personal computers to cellular phone or PDA. This research has a try to design a wireless measurement model of ECU signal based on the car telemery system using bluetooth device. In order to measure the ECU signals, we designed the interface circuits which is able to communicate between the ECU system and the terminal circuits according to the ISO, SAE regulation of communication protocol standard. A microprocessor S3c341 OX is used for the system control and communication of ECU signals. The embedded system software is programmed to measure the ECU signals using the ARM compiler and ANCI C based on Micro/OS-II kernel to communicate between two bluetooth modules using bluetooth stack. The remote measurement of ECU signals using the bluetooth was designed and implemented to evaluate the performance of wireless network to the transmit measurement data. The possibility for the remote measurement of the self diagnosis signals of ECU adopted with KWP2000 protocol verified through the developed systems and algorithms in embedded system.

위성체 얼라인먼트 측정 시스템에 관한 연구 (A Study on A Spacecraft Alignment Measurement System)

  • 박홍철;손영선;최종연;윤용식
    • 한국항공우주학회지
    • /
    • 제32권7호
    • /
    • pp.98-104
    • /
    • 2004
  • 위성체 얼라인먼트 측정은 측정 정밀도가 ${\pm}0.5^{\circ}$ 이하로 매우 정밀한 것이다. 일반적으로 이러한 측정은 3대 이상의 데오드라이트를 사용하여 측정되고 있다. 그러나 위성체의 위치 안정성 등에 의해 측정 정밀도 오차가 발생될 수 있다. 이에 따라, 데오드라이트, 회전 테이블 및 전자식 수평계 등을 조합하여 새로운 얼라인먼트 측정 시스템을 개발하게 되었다. 본 논문에서 이러한 측정 시스템의 개념과 측정 방법을 기술하였고, 기존의 측정 방법보다 더 좋은 정밀도를 얻을 수 있음을 알 수 있다.

DESIGN OF A VIBRATION AND STRESS MEASUREMENT SYSTEM FOR AN ADVANCED POWER REACTOR 1400 REACTOR VESSEL INTERNALS COMPREHENSIVE VIBRATION ASSESSMENT PROGRAM

  • Ko, Do-Young;Kim, Kyu-Hyung
    • Nuclear Engineering and Technology
    • /
    • 제45권2호
    • /
    • pp.249-256
    • /
    • 2013
  • In accordance with the US Nuclear Regulatory Commission (US NRC), Regulatory Guide 1.20, the reactor vessel internals comprehensive vibration assessment program (RVI CVAP) has been developed for an Advanced Power Reactor 1400 (APR1400). The purpose of the RVI CVAP is to verify the structural integrity of the reactor internals to flow-induced loads prior to commercial operation. The APR1400 RVI CVAP consists of four programs (analysis, measurement, inspection, and assessment). Thoughtful preparation is essential to the measurement program, because data acquisition must be performed only once. The optimized design of a vibration and stress measurement system for the RVI CVAP is essential to verify the integrity of the APR1400 RVI. We successfully designed a vibration and stress measurement system for the APR1400 RVI CVAP based on the design materials, the hydraulic and structural analysis results, and performance tests of transducers in an extreme environment. The measurement system designed in this paper will be utilized for the APR1400 RVI CVAP as part of the first construction project in Korea.

저선량과 고선량 측정구간 변환이 가능한 모바일 방사선 측정시스템 개발 및 평가 (Development and Evaluation of a Mobile Environmental Radiation Measurement System That Can Switch between Low and High Dose Measurement Sections)

  • 이홍연;한상준;김보길;이건주;김석현;김정훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권1호
    • /
    • pp.49-55
    • /
    • 2022
  • This study is to develop a mobile type environmental radiation measurement system for emergency response or environmental radiation monitoring of local governments near nuclear facilities. A mobile radiation measurement system can monitor radiation by field beyond the spatial constraints of a fixed environmental radiation monitor. If installed in local government infrastructure such as public transportation, environmental radiation can be monitored without additional manpower and measurement work. In addition, it is designed to enable monitoring and measurement of radiation from low to high doses as well as the environment in preparation for radioactive disasters such as nuclear power plant accidents. It is expected that this system will be utilized not only in normal times but also in the event of a radiation accident to improve the disaster prevention capabilities of local governments.

변압기철손 측정시스템의 측정 불확도 (Review of the measurement uncertainty of Tr no-load loss measuring system)

  • 강택수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.139-141
    • /
    • 2005
  • For the reliable evaluation of the distribution and power transformer no-load loss measurement, measurement uncertainty of the transformer measuring system, consisted of current transformer, potential transformer and power metering equipment is required. In this paper, we describe the uncertainty of transformer measuring system based on ANSI/IEEE C57.12.90.

  • PDF

화력발전소 주배관 3차원 변위측정시스템 개발 (Development of 3-D. Displacement Measurement System for Critical Pipe of Fossil Power Plant)

  • 송기욱;현중섭;하정수;조선영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1198-1205
    • /
    • 2003
  • Most domestic fossil power plant have exceeded 100,000 hours of operation with the severe operating condition. Among the critical components of fossil power plant, high temperature steam pipe system have had a many problems and damage from unstable displacement behavior because of frequent start up and shut down. In order to prevent the serious damage and failure of the critical pipe system in fossil power plant, 3-dimensional displacement measurement system were developed for the on-line monitoring system. 3-D Measurement system was developed with using the LVDT type sensor and rotary encoder type sensor, this system was installed and operated on the real power plant successfully. In the future time, network system of on-line diagnosis for critical pipe will be designed.

  • PDF

공영방송 성과측정관행의 진단 틀 (Diagnostic Framework for Performance Measurement Practices of Public Broadcasting)

  • 민재형
    • 경영과학
    • /
    • 제26권1호
    • /
    • pp.137-159
    • /
    • 2009
  • An organizational performance measurement practice is a function of performance measurement system and performance management system they are currently employing, and its quality is determined by evaluating the followings in a comprehensive manner: first, if they are measuring right things; second, if they are measuring in a right way; third, if they are actively facilitating a process of data collection, structuring, analysis, interpretation, and dissemination; and fourth, if they are using performance measurement results for the primary purposes of performance measurement. This study proposes a diagnostic framework for evaluating the performance measurement practices of public broadcasting which include the qualities of performance measurement and performance management, and develop a structured questionnaire for that purpose. The framework proposed in this study does not serve only as a useful tool for public broadcasting to revise their respective performance measures and performance measurement systems, but it also make their respective performance measurement practices a strategic management tool as well as an operational management one.

근전계 RCS 측정 오차 요인 및 불확도 분석 (An Analysis of Error Components and Uncertainties in Near-field RCS Measurement)

  • 서민경;태현성;김정규;박호민
    • 한국군사과학기술학회지
    • /
    • 제23권4호
    • /
    • pp.346-354
    • /
    • 2020
  • Nowadays, it is required to apply low observable technology to weapon systems in operation or under development. Radar Cross Section(RCS) is a measure of the scattered power in an given direction when a target is illuminated by an incident wave and used as a parameter to estimate the low observable performance of weapon system. RCS of a target can be calculated by various numerical methods. However, measurement is also needed to estimate RCS of a complex target because it is difficult to estimate theoretically. To acquire reliable measurement results, an analysis of measurement uncertainty is essential. In this paper, error components and uncertainties of near-field RCS measurement system which was constructed in ASTEC(Aerospace System Test & Evaluation Center) were analyzed based on the IEEE recommended practice for radar cross-section test procedures(IEEE Std. 1502-2007) which describes the uncertainty of RCS measurement and unique error components of this near-field measurement system were also identified.