• Title/Summary/Keyword: measurement site

Search Result 1,437, Processing Time 0.036 seconds

Associations Among Different Types of Quantitative Pain Measures in TMD Patients (측두하악장애환자에서 다양한 종류의 정량적 통각검사들의 연관성에 관한 연구)

  • Park, Ji-Woon;Kim, Yong-Woo;Chung, Jin-Woo
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.4
    • /
    • pp.413-419
    • /
    • 2007
  • The aims of this study were to investigate the relationships among several types of thermal pain thresholds, and pressure pain thresholds. This study was designed to examine whether there were associations among different types of pain thresholds, and among different recording sites for each pain threshold measurement. Pain sensitivity thresholds including cold pain threshold (CPT), heat pain threshold (HPT), heat pain tolerance threshold (PTT), and pressure pain threshold (PPT) of 56 subjects with symptoms of temporomandibular disorders were measured on temporal muscle, masseter muscle, TMJ, and tibial areas. Thermal pain thresholds including CPT, HPT, and PTT did not show any gender differences. However, women showed significantly lower PPTs than men on all recording sites. Three thermal pain thresholds including CPT, HPT, and PTT showed weak to high correlations on all the recording sites (r= 0.324 to 0.754, p<0.05). PPTs did not show any significant correlations between each thermal pain threshold. The pain threshold of each recording site showed weak to high correlations in all pain threshold measures (r= 0.284 to 0.878, p<0.05). Our study demonstrated that thermal pain thresholds, and pain tolerance thresholds were significantly correlated, but did not show any correlation between thermal pain thresholds and pressure pain thresholds. There were relatively high correlations among the pain thresholds of different recording sites.

Improvement of Rating Curve Fitting Considering Variance Function with Pseudo-likelihood Estimation (의사우도추정법에 의한 분산함수를 고려한 수위-유량 관계 곡선 산정법 개선)

  • Lee, Woo-Seok;Kim, Sang-Ug;Chung, Eun-Sung;Lee, Kil-Seong
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.8
    • /
    • pp.807-823
    • /
    • 2008
  • This paper presents a technique for estimating discharge rating curve parameters. In typical practical applications, the original non-linear rating curve is transformed into a simple linear regression model by log-transforming the measurement without examining the effect of log transformation. The model of pseudo-likelihood estimation is developed in this study to deal with heteroscedasticity of residuals in the original non-linear model. The parameters of rating curves and variance functions of errors are simultaneously estimated by the pseudo-likelihood estimation(P-LE) method. Simulated annealing, a global optimization technique, is adapted to minimize the log likelihood of the weighted residuals. The P-LE model was then applied to a hypothetical site where stage-discharge data were generated by incorporating various errors. Results of the P-LE model show reduced error values and narrower confidence intervals than those of the common log-transform linear least squares(LT-LR) model. Also, the limit of water levels for segmentation of discharge rating curve is estimated in the process of P-LE using the Heaviside function. Finally, model performance of the conventional log-transformed linear regression and the developed model, P-LE are computed and compared. After statistical simulation, the developed method is then applied to the real data sets from 5 gauge stations in the Geum River basin. It can be suggested that this developed strategy is applied to real sites to successfully determine weights taking into account error distributions from the observed discharge data.

Application of Total Station for Structure and Terrain Displacement Monitoring (구조물 및 지형변위 모니터링을 위한 토털스테이션의 활용)

  • Park, Joon-Kyu;Um, Dae-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.4
    • /
    • pp.582-587
    • /
    • 2020
  • Recently, disasters caused by extreme weather and the damage caused by them are increasing worldwide. The interest in disasters, such as earthquakes, typhoons, and ground subsidence, is increasing in Korea. Korea has enacted a special law based on disaster management, and has built monitoring systems for individual facility units by building precision sensors and related systems to measure the displacement status of long bridges and high-rise composite buildings. On the other hand, the application of a real-time monitoring system is insufficient for slopes, open-pit mines, small and medium structures due to weather, measurement methods, cost, and constant monitoring difficulties. In this study, the displacement monitoring method using the total station was studied and the applicability was suggested through the experiment. Through the research, the concept and operation flow of a monitoring system that can measure the displacement of the terrain or the structure using the total station was presented. The monitoring system allows the user to select the location and operation method of the equipment so that the equipment can be installed according to the site situation, and set the number of observations, the period, and the observation range of the object. Using the experiment on the monitoring system, the station was monitored with precision within 5mm, and it was suggested that the displacement of the object can be monitored using the total station. Further research will be needed to assess the applicability of monitoring to real slopes and structures.

Implementation of the ECG Monitoring System for Home Health Care Using Wiener Filtering Method (Wiener Filtering 기법을 적용한 홈헬스케어용 심전도 신호 모니터링 시스템 구현)

  • Jeong, Do-Un;Kim, Se-Jin
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.9 no.2
    • /
    • pp.104-111
    • /
    • 2008
  • The ECG is biomedical electrical signal occurring on the surface of the body due to the contraction and relaxation of the heart. This signal represents an extremely important measure for health monitoring, as it provides vital information about a patient's cardiac condition and general health. ECG signals are contaminated with high frequency noise such as power line interference, muscle artifact and low frequency nose such as motion artifact. But it is difficult to filter nose from ECG signal, and errors resulting from filtering can distort a ECG signal. The present study implemented a small-size and low-power ECG measurement system that can remove motion artifact for convenient health monitoring during daily life. The implemented ECG monitoring system consists of ECG amplifier, a low power microprocessor, bluetooth module and monitoring program. Amplifier was designed and implemented using low power instrumentation amplifier, and microprocessor was interfaced to the ECG amplifier to collect the data, process, store and feed to a transmitter. And bluetooth module used to wirelessly transmit and receive the vital sign data from the microprocessor to an PC at the receiving site. In order to evaluate the performance of the implemented system, we assessed motion artifact rejection performance in each situation with artificially set condition using adaptive filter.

  • PDF

Relationship Between Above-and Below-Ground Biomass for Norway Spruce (Picea abies) : Estimating Root System Biomass from Breast Height Diameter (독일가문비나무(Picea abies [L.] Karst)의 지상부(地上部)와 지하부(地下部) 생체량(生體量)에 관(關)한 연구(硏究) : 흉고직경(胸高直徑)에 의한 뿌리생체량(生體量) 추정(推定))

  • Lee, Do-Hyung
    • Journal of Korean Society of Forest Science
    • /
    • v.90 no.3
    • /
    • pp.338-345
    • /
    • 2001
  • This study was conducted to elucidate the relationship between the root structure and the crown structure of Norway spruce(Picea abies [L.] Karst), and thereafter to obtain the regression equation for the estimation of relative root and needle biomass using the tree height and diameter at breast height(DBH) without measurement of root and needle biomass. The study site was Barbis stands of Harz region located in central part of Germany. Five dominant and three co-dominant trees of 30 to 40 year-old Norway spruce were selected and tree height, diameter at breast height, clear bole length, weight of total needle and branch, cross section and sapwood area at breast height for biomass of above ground part and also the length of root, the number of root, the weight of root, the cross section area of root etc. by dividing the horizontal and vertical roots for below ground part of tree were measured. The significantly correlation was shown between the biomass of most of variables of above ground parts and those of below ground parts. For the diameter of breast height to the weight of total root, regression equation was Y = 3.56X - 45.94 and decision coefficient was 0.96 showing highly correlation. The weight of total branches and needles, and the tree height etc. of above ground parts showed highly positive relationship with below ground biomass. The results obtained from this study can be used to the estimating of biomass of below ground using variables of above ground such as DBH in the 30 to 40 year-old Norway spruce stands.

  • PDF

Relationship between Total Body Fat and S/V Ratio and Body Cooling for Two Hours at $15^{\circ}C$ (한냉에 노출된 인체의 냉각과 총지방량 및 S/V 비율 사이의 관계)

  • Chung, Kwan-Ogg;Nam, Kee-Yong
    • The Korean Journal of Physiology
    • /
    • v.3 no.1
    • /
    • pp.19-28
    • /
    • 1969
  • Skin temperatures on 10 sites and rectal temperature at every 10 minutes, oxygen consumption at every 20 minutes were measured on 18 male subjects (ages between 14 and 47 years) after exposure to cold air at $15^{\circ}C$ for two hours in a climatic room. Total body fat measured by means of a skinfold method and ratio of body surface area (S) to body volume (V), S/V, were utilized as basis of observations. Surface area was calculated after DuBois equation and body volume was calculated by our original formula. In influencing on the heat loss from the body core to the cold environment, % fat showed inverse relations, whereas, S/V ratio showed direct relations. Thus these two factors acted antagonistically on the body heat loss. Local skin temperatures showed negative correlations with skinfold thickness on the same site, nemaly, on chest, r=-.567; on back, r=-.507; and on upper arm, r=-.353. The other 7 skin sites showed low correlations with % fat. Minimum mean weighted skin temperature (MWST) showed a negative correlation (r=-.443) with % fat, and showed no correlation with S/V ratio. Oxygen consumption in the cold air at $15^{\circ}C$ increased from the first measurement at 20 minutes after exposure and maintained the same increasing trend up to 120 minutes. ${\Delta}T_R$ was greater in tile lean subjects who showed a greater % change in oxygen consumption. The antagonistic actions of % fat and S/V ratio on the heat loss were manifested by observations as follows: minimum rectal temperature was higher In fat subjects (r=.600) and lower in subjects with a greater S/V ratio (=-.582), ${\Delta}T_R$ was smaller in fat subjects (r=-.738) and greater in subjects with a greater S/V ratio (r=.618). Temperature difference between body core and skin surface (minimum rectal temperature minus minimum MWST) showed a positive correlation with % fat (r=.600) and a negative correlation with S/V ratio (r=-.881). Decrease in the mean body temperature and heat debt, respectively, showed negative correlations with % fat and positive correlations with S/V ratio.

  • PDF

Physiological Analysis of Walking - Physical Exercise for the Promotion of National Health - (걷기의 생리학적 분석 - 체력 증진을 위한 운동 -)

  • Nam, Kee-Yong;Chang, Shin-Yo;Shin, Dong-Hoon;Sung, Nak-Eung;Earm, Yung-E
    • The Korean Journal of Physiology
    • /
    • v.4 no.1
    • /
    • pp.1-11
    • /
    • 1970
  • Studies on the analysis of walking were performed on 33 male subjects. A prescription of physical exercise (walking at a speed of greater than 6 km/hr for more than one hour daily) for the promotion of individual health is presented on the basis of walking analysis. Presumptions were made that adequate physical exercise does promote health and is beneficial for the healthy life and increases the life span. These presumptions were derived from the numerous experimental literatures. The literatures support indirectly the presumptions. The following results were obtained and prescription of physical exercise is presented. 1. Oxygen uptake in a walking on a treadmill at a speed of 4 km/hr was only 3 times of the resting oxygen uptake. This kind of moderate exercise did not stimulate the cardiopulmonary system adequately. Heart rate at a 4 km/hr walking was 101 beats/min in boys of less than 20 years old and 83 beats/min in adults. Oxygen uptake at a 6 km/hr walking exceeded 4 times of the resting oxygen uptake. It was interpreted that walking at 6 km/hr stimulated the cardiopulmonary system for the promotion of health. Heart rate at this speed was greater than 110 beats/min in boys and greater than 100 beats/min in adults. 2. Heart rates in a walking of 10 km/hr were 172 beats/min in boys, and 143 beats/min in adults, respectively. Maximal heart rates were 185 beats/min in boys, 180 in office clerks, and 168 beats/min in construction site laboreres. 3. The correlation between heart rate and oxygen uptake was high, namely, r>0.95. Subsequently heart rate could be used as a measure of degree of intensity of physical exercise instead of the cumbersome oxygen uptake measurement. 4. The prescription of physical exercise for the promotion of health is: Daily walking for more than one hour at a speed of greater than 6 km/hr. Bodily functions in this daily walking are in boys (body weight, 50 kg): heart rates of 110 beats/min; breathing frequency, 28/min; oxygen uptake, greater than 4 times of the resting uptake; pulmonary ventilation, 351/min; stride, 124 strides/min; cumulative number of strides for one hour, 7,440 strides, and energy expenditure of more than 300 kcal. In adults (body weight, 60 kg) the bodily functions are: heart rates of 100 beats/min, breathing frequency, 28/min; oxygen uptake, greater than 4 times of the resting uptake; Pulmonary ventilation, 301/min; stride, 127 strides/min; cumulative number of strides for one hour, 7,670 strides, and energy expenditure of more than 300 kcal.

  • PDF

Archaeomagnetic Study on Archaeological Sites in Jeju Region (제주지역 유적에 대한 고고지자기학적 연구)

  • Sung, Hyong Mi
    • Journal of Conservation Science
    • /
    • v.33 no.3
    • /
    • pp.181-188
    • /
    • 2017
  • A total of 16 precious archaeomagnetic dating data were obtained from various historic sites including fired soils from eight archaeological sites on Jeju Island. We researched the measurement results of 12 pieces of data from before the Common Era (BCE), and four pieces of data from after the Common Era. First, the BCE data could be divided into three groups (A, B, and C) based on the difference in the archaeomagnetic data. By comparing the data accumulated in other parts of Korea and referring to the archaeological years, the order of the groups was as follows: A group (Bronze Age~Early Iron Age) ${\rightarrow}$ B group (Early Iron Age when the circular rim eomtodae pottery was excavated) ${\rightarrow}$ C group (Early Iron Age when triangulated rim jeomtodae pottery was excavated), with A group being the earliest data group and C group being the latest data group. In addition, the data after the Common Era could be used to determine the archaeomagnetic dating of the archaeological sites. Through the archaeomagnetic dating of Jeju's archaeological sites for the BCE period, the relative order of the relics was determined, and for the period after the Common Era, the absolute age of the historic sites was obtained. They are expected to be used diversely in the chronological study of Jeju.

A Study for Deducing the Problems and Improvements of Health Safety and Welfare Policy for Korean Firefighters by Delphi (델파이 기법을 통한 소방공무원 보건안전정책의 문제점 및 개선방안 도출)

  • Park, Chanseok
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.1
    • /
    • pp.34-43
    • /
    • 2020
  • Purpose: In this study, we will try to find out problems and improvements of the policies in order to verify whether the plans contribute to the health and welfare of the firefighters properly. Method: By the Delphi analysis by experts. Result: There are problems such as absence of Firefighters' hospital, insufficient mental health education program in fire department, lack of on-site risk assessment system, problem on ineffectiveness of mental and physical health care business, lack of substantiality on mental and physical stability program, absence of mental health education, ensuring the confidentiality for users of mental health programs, lack of support for parent firefighters, lack of firefighters' retirement design and insufficient treatment for female firefighters. Conclusion: There are Improvements such as establishing Firefighters' hospital, improving mental health education and training CISD leaders in the fire department, preparing disaster risk assessment system, effectiveness measurement for visiting psychological counseling projects, improving the program through customer satisfaction surveys, establishment of mental health education system, ensuring confidentiality by improving personnel systems, encourage childcare leave and introduce childcare facilities at fire stations, revitalizing retirement Firefighters and policy development for female firefighters.

Analysis of Solar Irradiance Measurement From a Multi-Filter Radiometer At Kwangju, South Korea.

  • Ogunjobi, K.O.;Kim, Y.J.;He, Z.;Ryu, S.Y.
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2001.11a
    • /
    • pp.335-335
    • /
    • 2001
  • Direct-normal, total horizontal and diffuse horizontal irradiance data obtained from a multi-filter rotating shadowband radiometer over seven different wavelength bands (416nm, 151nm, 616nm, 675nm, 870nm and 940nm and the entire spectrum) has been analyzed at Kwangju, South Korea from June 1998 December 2000. The maximum hourly global radiation flux ranged from 0.44 MJ/$m^2$ to 2.68 MJ/$m^2$ at around 11:00-12:00 Hr local time while the maximum hourly diffuse radiation flux ranged from about 0.96 MJ/$m^2$ to 1.37 MJ/$m^2$. The maximum hourly direct irradiance ranged from 1.42 MJ/$m^2$ to 2.92 MJ/$m^2$ from June1998-2000. During the period under consideration, the average monthly global radiation recorded were 13.09 MJ/$m^2$/day, 10.58MJ/$m^2$/day and 9.78MJ/$m^2$/day for years 1998, 1999 and 2000 respectively, while the diffuse irradiance were 6.54 MJ/$m^2$/day, 5.33 MJ/$m^2$/day and 5.14 MJ/$m^2$/day for f998, 1999 and 2000 respectively. The direct irradiance values at the site were 11.63 MJ/$m^2$/day, 8.24MJ/$m^2$/day and 7.75 MJ/$m^2$/day for 1998, f999 and 2000 respectively. It was observed that each of the years has its own unique meteorological parameters that affect the quality and quantity of radiation received for each month. The annual average daily fractions of the diffuse to the global radiation (KD) were 0.51, 0.61 and 0.59 for years 1998, 1999 and 2000 respectively. Analysis indicated that the average daily KD ranged from 0.13 to a maximum value of 0.99 in May for irradiance measured at the broadband channel while the maximum and minimum KD value of 0.91 and 0.23 was recorded at wavelength band 870nm and 940nm in January and September respectively. The lowest average daily clearness index (Kt) value recorded was 0.03 in May (Spring) and the annual average daily clearness indexes are 0.45, 0.34 and 0.35 for years 1998, f999 and 2000 respectively. The frequency of clear days annually at Kwangju is 67.95%, 29.57% and 40.72% for years 1998, 1999 and 2000 respectively.

  • PDF