• Title/Summary/Keyword: measurement set

Search Result 1,831, Processing Time 0.028 seconds

System Development for Automatic Tool Wear Measurement (자종공무마모계측시스템개발)

  • Kim, Y.I.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.11 no.6
    • /
    • pp.185-199
    • /
    • 1994
  • This study has been performed to present a new automatic tool wear measurement by digital image processing. The purpose of this paper is to develop an automatic tool wear measuring system based on the image processing which can be applied to the quasi-real time measurement of the characteristics of insert tip in turning. Tool wear monitoring is one of the key-problems, for the development of control systems of modern unmanned factory which are not completely solved now. In oredr words at present complete qualitative and quantitative information on tool wear morphology is required, at least on the following aspects : flank wear, its dimensions and distribution on the maximum and mean values on VB pqrqmeter in the various zones of the wearland. crater wear, its main dimensions and values of KT parameters. This research has been performed to this technique made possible by designing a proper lighting system to the worn tool with following features : The flank wear is measured by observing the active cutting part from a proper direction and by lighting the wearland by a diffuser optic system. The crater wear is visualized by lighting the tool by a He-Ne gas laser system developed in this study. By means of this system it is research to evaluate classical parameters of tool wear and to have complete information about tool wear morphology.

  • PDF

Standards for Ground Settlement Management when Reinforcing Ground in the Abandoned Mine (폐광지역 지반공사시 지반침하 관리를 위한 기준)

  • Yang, In Jae;Lee, Seung Ah;Baik, Dong Ho
    • Tunnel and Underground Space
    • /
    • v.27 no.5
    • /
    • pp.295-302
    • /
    • 2017
  • In this study, a new quantitative instrumentation and measurement standards applicable to the field of mining has been proposed to improve the problems of the current measurement practices that apply the measuring standards of the civil engineering field (road, railway, etc.). With the data coordination of the mine reclamation corporation, we collected data on ground subsidence in the abandoned mine area, and studied various techniques for establishing a new management reference value based on the manual measurement data measured in the field. As a result, new instrumentation and measurement standards is set up and proposed by using statistics like the average value, the third quartile, the 95% confidence, and the maximum value.

An automated measurement system for the microwave surface resistance of high-T$_c$ superconductor films

  • Lee, J.H.;Lim, J.;Lee, Jung-Hun;Lee, Sang-Young
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.173-178
    • /
    • 2000
  • A prototype for a highly sensitive, automated measurement system for the microwave surface resistance of high-T$_c$ superconductor films was set up, and tested by measuring the microwave surface resistances of high-T$_c$ YBa$_2$Cu$_3$O$_{7-{\delta}}$(YBCO) films at the frequency of about 19.6 GHz and the temperature of 30 K ${\sim}$ 90 K. An open-ended TE$_{011}$ mode sapphire-loaded cylindrical cavity resonator was used as the measurement probe, where YBCO films were used as the endplates of the cylindrical cavity. The characteristics of the measurement system include functions to display the unloaded ${\varrho}$ and the resonant frequency of the TE$_{011}$ mode resonator as well as the microwave surface resistance of the YBCO films, all simultaneously as a function of temperature. Applicability of the measurement system for investigating the homogeneity in the microwave properties of large high-T$_c$ superconductor films is discussed.

  • PDF

An Automated Measurement System for the Microwave Surface Resistance of High-$T_c$ Superconductor Films

  • Lee, J.H.;Lim, J.;Lee, Jung-Hun;Lee, Sang-Young
    • Progress in Superconductivity
    • /
    • v.2 no.1
    • /
    • pp.27-32
    • /
    • 2000
  • A prototype for a highly sensitive, automated measurement system for the microwave surface resistance of high-$T_c$ superconductor films was set up, and tested by measuring the microwave surface resistances of high-$T_c$ $YBa_2Cu_3O_{7-\delta}$ (YBCO) films at the frequency of about 19.6 GHz and the temperature of 30 K $\sim$ 90 K. An open-ended $TE_{011}$ mode sapphire-loaded cylindrical cavity resonator was used as the measurement probe, where YBCO films were used as the endplates of the cylindrical cavity. The characteristics of the measurement system include functions to display the unloaded Q and the resonant frequency of the $TE_{011}$ mode resonator as well as the microwave surface resistance of the YBCO films, all simultaneously as a function of temperature. Applicability of the measurement system for investigating the homogeneity in the microwave properties of large high-$T_c$ superconductor films is discussed.

  • PDF

Development of a Real-time 3D Intraoral Scanner Based on Fringe-Projection Technique (프린지 투영법을 이용한 실시간 3D 구강 내 스캐너의 개발)

  • Ullah, Furqan;Lee, Gunn-Soo;Park, Kang
    • Korean Journal of Computational Design and Engineering
    • /
    • v.17 no.3
    • /
    • pp.156-163
    • /
    • 2012
  • Real-time three-dimensional shape measurement is becoming increasingly important in various fields, including medical sciences, high-technology industry, and microscale measurements. However, there are not so many 3D profile tools specially designed for specifically narrow space, for example, to scan the tooth shape of a human jaw. In this paper, a real-time 3D intraoral scanner is proposed for the measurement of tooth profile in the mouth cavity. The proposed system comprises a laser diode beam, a micro charge-coupled device, a graticule, a piezoelectric transducer, a set of optical lenses, and a polhemus device sensor. The phase-shifting technique is used along with an accurate calibration method for the measurement of the tooth profile. Experimental and theoretical inspection of the phase-to-coordinate relation is presented. In addition, a nonlinear system model is developed for collimating illumination that gives the more accurate mathematical representation of the system, thus improves the shape measurement accuracy. Experiment results are presented to verify the feasibility and performance of the developed system. The experimental results indicate that overall measurement error accuracy can be controlled within 0.4 mm with a variability of ${\pm}0.01$.

Optimal Placement of the Phasor Measurement Units in Power System (전력계통의 페이저 측정기 최적배치)

  • Kim, Jae-Hun;Jo, Gi-Seon;Kim, Hoi-Chul;Shin, Jung-Rin
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.7
    • /
    • pp.313-322
    • /
    • 2000
  • This paper presents optimal placement of minimal set of Phasor Measurement Units (PMU's) and observability analysis of the network with PMU's. In order to find a observable system, a symbolic method which directly assigns an appropriate symbol for measurement or pseudo-measurement to every entry of node-branch incidence matrix is proposed. It is much simpler and easier to analyze the observability of the network with PMU's than the conventional ones. For the optimal PMU placement problem, two approaches which are based on a modified Simulated-Annealing (SA) method and a Direct Combination method are proposed. Some case studies with IEEE sample system are made to show the performance of the proposed methods are almost alike and more effective than the conventional simulated-annealing method. It is also shown that the Direct Combination method is more effective than the modified simulated-annealing one in the sense of computation burden. The results of this study showed also that the accuracy of power system estimation and system observability can be improved the proposed PMU placements.

  • PDF

Design and Fabrication of an Ultra-low Partial Discharge Measurement System (극미소 부분방전 측정시스템의 설계 및 제작)

  • Seo, Hwang-Dong;Song, Jae-Yong;Moon, Seung-Bo;Kil, Gyung-Suk;Kwon, Jang-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.2
    • /
    • pp.208-211
    • /
    • 2005
  • This paper presents an ultra-low partial discharge(PD) measurement system that has been accepted as a non-destructive method to estimate electrical insulation of low-voltage electric devices. The PD measurement system is composed of a coupling network, a low noise amplifier, and associated electronics. A shielding box is used to make a better condition against electromagnetic interference. A low cut-off frequency of the coupling network was 1MHz(-3 dB). Calibration tests on laboratory set-up have shown that the PD measurement system has a stable sensitivity of 11.4mV/pC. In an application experiment on a low-voltage induction motor(5HP), we could detect 0.77pC level of partial discharge pulse at the applied voltage of AC 664 V$_{peak}$.

  • PDF

Frequency-Based Image Analysis of Random Patterns: an Alternative Way to Classical Stereocorrelation

  • Molimard, J.;Boyer, G.;Zahouani, H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.3
    • /
    • pp.181-193
    • /
    • 2010
  • The paper presents an alternative way to classical stereocorrelation. First, 2D image processing of random patterns is described. Sub-pixel displacements are determined using phase analysis. Then distortion evaluation is presented. The distortion is identified without any assumption on the lens model because of the use of a grid technique approach. Last, shape measurement and shape variation is caught by fringe projection. Analysis is based on two pin-hole assumptions for the video-projector and the camera. Then, fringe projection is coupled to in-plane displacement to give rise to 3D measurement set-up. Metrological characterization shows a resolution comparable to classical (stereo) correlation technique ($1/100^{th}$ pixel). Spatial resolution seems to be an advantage of the method, because of the use of temporal phase stepping (shape measurement, 1 pixel) and windowed Fourier transform (in plane displacements measurement, 9 pixels). Two examples are given. First one is the study of skin properties; second one is a study on leather fabric. In both cases, results are convincing, and have been exploited to give mechanical interpretation.

Performance of Continuous-wave Coherent Doppler Lidar for Wind Measurement

  • Jiang, Shan;Sun, Dongsong;Han, Yuli;Han, Fei;Zhou, Anran;Zheng, Jun
    • Current Optics and Photonics
    • /
    • v.3 no.5
    • /
    • pp.466-472
    • /
    • 2019
  • A system for continuous-wave coherent Doppler lidar (CW lidar), made up of all-fiber structures and a coaxial transmission telescope, was set up for wind measurement in Hefei (31.84 N, 117.27 E), Anhui province of China. The lidar uses a fiber laser as a light source at a wavelength of $1.55{\mu}m$, and focuses the laser beam on a location 80 m away from the telescope. Using the CW lidar, radial wind measurement was carried out. Subsequently, the spectra of the atmospheric backscattered signal were analyzed. We tested the noise and obtained the lower limit of wind velocity as 0.721 m/s, through the Rayleigh criterion. According to the number of Doppler peaks in the radial wind spectrum, a classification retrieval algorithm (CRA) combining a Gaussian fitting algorithm and a spectral centroid algorithm is designed to estimate wind velocity. Compared to calibrated pulsed coherent wind lidar, the correlation coefficient for the wind velocity is 0.979, with a standard deviation of 0.103 m/s. The results show that CW lidar offers satisfactory performance and the potential for application in wind measurement.

Study on Fabrication of a Large Concave Mirror Surface Using a Swing-Arm Type Profilometer (스윙암 방식의 형상 측정기를 이용한 대형 반사경의 정밀가공에 관한 연구)

  • Lee, Ki-Am;Kim, Ock-Hyun;Lee, Eung-Suk
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.7 no.3
    • /
    • pp.41-46
    • /
    • 2008
  • Generally optical components are fabricated by grinding, lapping and polishing processes. Those processes take long time to obtain optical high surface quality. In the case of large optical components, the on-machine measurement is strongly recommended because the workpiece is fragile and difficult to set up for fabricating and measuring. This paper is concerned about a swing-arm mechanism which can be used for on-machine measurement of a surface profile with a sensing probe end-effect, and also for grinding or lapping the surface with a corresponding tool. The measuring accuracy and uncertainty using a swing arm type profilometer have been studied. The experimental results show that this method is useful specially in lapping process with the accuracy of $5{\mu}m$. Those inspection data are provided for correcting the residual figuring error in next processes.

  • PDF