• Title/Summary/Keyword: measurement quality

Search Result 4,456, Processing Time 0.026 seconds

A Study on the Effect of Gage R&R for 6 Sigma Quality (6시그마 품질을 위한 Gage R&R의 영향에 관한 연구)

  • 이승훈;이정환
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.23 no.55
    • /
    • pp.13-24
    • /
    • 2000
  • 6 sigma movement is the most prominent quality improvement methodology in practice. Measurement plays an important role in helping any organization improve quality. Therefore, the measurement systems analysis is the first step for the quality improvement of manufacturing process in 6 sigma movement. In this study, we investigate the effect of Gage Repeatability and Reproducibility(Gage R&R) in view of defect rate and process capability indices, and provide guidelines for acceptance of gage repeatability and reproducibility(%R&R) for six sigma quality.

  • PDF

A Survey Study on the Demand and Supply of Measurement Labor in Korean Industry (한국산업(韓國産業)의 측정기술인력(測定技術人力) 수급실태(需給實態) 조사연구(調査硏究))

  • Lee, Dong-Su;Kim, Dong-Jin;An, Jong-Chan
    • Journal of Korean Society for Quality Management
    • /
    • v.21 no.1
    • /
    • pp.11-21
    • /
    • 1993
  • In this paper, we survey the current status of measurement labor in Korean Industry. At the same time we try to predit the demand and supply of measurement labor to suggest policy measures for equilibrium in measurement labor market. We use a general production function for the prediction which include a set of general homethetic production function.

  • PDF

A Data Quality Measuring Tool (데이타 품질 측정 도구)

  • 양자영;최병주
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.9 no.3
    • /
    • pp.278-288
    • /
    • 2003
  • Quality of the software is affected by quality of data required for operating the actual software. Especially, it is important that assure the quality of data in a knowledge-engineering system that extracts the meaningful knowledge from stored data. In this paper, we developed DAQUM tool that can measure quality of data. This paper shows: 1) main contents for implement of DAQUM tool; 2) detection of dirty data via DAQUM tool through case study and measurement of data quality which is quantifiable from end-user's point of view. DAQUM tool will greatly contribute to improving quality of software product that processes mainly the data through control and measurement of data quality.

Cost-effective Investigation on Contaminated Land and Assessment of Measurement Uncertainty (오염토양의 효율적 조사기법과 측정불확도의 평가방법)

  • 이종천
    • Economic and Environmental Geology
    • /
    • v.37 no.1
    • /
    • pp.49-59
    • /
    • 2004
  • The concectration and distribution of contaminants obtained from a contaminated land investigation or an environmental geochemistry survey constitutes the basis of a decision-making process on environmental policies or of scientific researches. As the quality of data determines the reliability of the result, the investigation plan should be adjusted according to the purpose of the investigation. In general, the effort to improve the data quality had been focused mainly on the QA/QC procedures in laboratories. The rapid progress of analytical instrument has also contributed toward improving the analytical precision to a sacrificable degree. Nevertheless, in many cases, it is not the analytical precision that needs improvement for the better precision of overall measurement process: it is rather during the sampling process in the field that is responsible for the poor precision. To assess the data quality on a measured value, ISO recommends to provide information on "measurement uncertainty" along with the measured value. The measurement uncertainty in an environmental measurement context can be explained as the statistical number that expresses the degree of the uncertainty stemming from the sampling and analytical procedures. There is a cost involved in order to improve the precision of sampling and analytical methods so as to decrease the degree of measurement uncertainty. The economical point of compromise in an investigation planning can be achieved when the allowable degree of uncertainty has been set before-hand. The investigation can then be planned accordingly not to exceed the uncertainty limit. Furthermore, if the measurement uncertainty estimated from the preliminary investigation can be separated into sampling and analytical uncertainties, it can be used as a criterion where the resources for the investigation should be allotted cost-effectively to reinforce the weakest link of the whole investigation process. This paper aims to present a method of estimating the level of measurement uncertainty of a measured contamination concentration at a site used as an example and to show how the estimated uncertainty can be applied to serve the particular purpose of an investigation.

Influence of Heart Rate and Innovative Motion-Correction Algorithm on Coronary Artery Image Quality and Measurement Accuracy Using 256-Detector Row Computed Tomography Scanner: Phantom Study

  • Jeong Bin Park;Yeon Joo Jeong;Geewon Lee;Nam Kyung Lee;Jin You Kim;Ji Won Lee
    • Korean Journal of Radiology
    • /
    • v.20 no.1
    • /
    • pp.94-101
    • /
    • 2019
  • Objective: To investigate the efficacy of motion-correction algorithm (MCA) in improving coronary artery image quality and measurement accuracy using an anthropomorphic dynamic heart phantom and 256-detector row computed tomography (CT) scanner. Materials and Methods: An anthropomorphic dynamic heart phantom was scanned under a static condition and under heart rate (HR) simulation of 50-120 beats per minute (bpm), and the obtained images were reconstructed using conventional algorithm (CA) and MCA. We compared the subjective image quality of coronary arteries using a four-point scale (1, excellent; 2, good; 3, fair; 4, poor) and measurement accuracy using measurement errors of the minimal luminal diameter (MLD) and minimal luminal area (MLA). Results: Compared with CA, MCA significantly improved the subjective image quality at HRs of 110 bpm (1.3 ± 0.3 vs. 1.9 ± 0.8, p = 0.003) and 120 bpm (1.7 ± 0.7 vs. 2.3 ± 0.6, p = 0.006). The measurement error of MLD significantly decreased on using MCA at 110 bpm (11.7 ± 5.9% vs. 18.4 ± 9.4%, p = 0.013) and 120 bpm (10.0 ± 7.3% vs. 25.0 ± 16.5%, p = 0.013). The measurement error of the MLA was also reduced using MCA at 110 bpm (19.2 ± 28.1% vs. 26.4 ± 21.6%, p = 0.028) and 120 bpm (17.9 ± 17.7% vs. 34.8 ± 19.6%, p = 0.018). Conclusion: Motion-correction algorithm can improve the coronary artery image quality and measurement accuracy at a high HR using an anthropomorphic dynamic heart phantom and 256-detector row CT scanner.

The Effects of Imprecise Measurement on the Economic Asymmetric $\bar{X}$ and S Control Charts

  • Yang, Su-Fen
    • International Journal of Quality Innovation
    • /
    • v.3 no.2
    • /
    • pp.46-56
    • /
    • 2002
  • The presence of imprecise measurement may seriously affect the efficiency of process control and production cost. A cost model is derived to determine the design parameters of the economic asymmetric $\bar{X}$ and S control charts including measurement errors. The effects of imprecise measurement on the performance of the economic asymmetric $\bar{X}$ and S control charts and production cost are examined for the case where the process mean and process standard deviation may change. Application of the proposed control charts is demonstrated through an example. Numerical examples illustrate the effects of imprecise measurement on the design parameters of the proposed control charts. It shows that the imprecision measurement may seriously affrct the ability of the proposed control charts to detect process disturbances quickly, change the sampling frequency, and increase the production cost compared to the control charts excluding measurement errors.

Some Relationships between Measurement Capability Indices of Type 1 Study, Gage R&R Study, and ISO 22514-7 (Type 1 Study, Gage R&R Study와 ISO 22514-7의 측정능력지수 간 연관성 분석)

  • Lee, Seung-Hoon;Lim, Keun
    • Journal of Korean Society for Quality Management
    • /
    • v.44 no.1
    • /
    • pp.77-94
    • /
    • 2016
  • Purpose: This paper reviews Type 1 Gage study, Gage R&R study, and procedure of ISO 22514-7 for assessing a measurement system, and discusses some relationships between the measurement capability indices. Methods: The gage capability index $C_g$ of Type 1 Gage study, precision-to-tolerance ratio PTR of Gage R&R study, and measurement performance ratio $Q_{MS}$ and $Q_{MP}$ of ISO 22514-7 are considered in this paper. Results: This paper derives the relationships between $C_g$ and $Q_{MS}$, PTR and $Q_{MP}$, and $Q_{MS}$ and $Q_{MP}$, respectively, and discusses the acceptance conditions for each procedures. Conclusion: The measurement capability analysis is the first step for the quality improvement of the manufacturing processes. Therefore the result of this study provides a helpful guidelines for assessing the measurement system, enabling proper evaluation of manufacturing processes.

Modeling and Measurement of Thermal Errors for Machining Center using On-Machine Measurement System (기상계측 시스템을 이용한 머시닝센터의 열변형 오차 모델링 및 오차측정)

  • 이재종;양민양
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.1
    • /
    • pp.120-128
    • /
    • 2000
  • One of the major limitations of productivity and quality in metal cutting is the machining accuracy of machine tools. The machining accuracy is affected by geometric errors, thermally-induced errors, and the deterioration of the machine tools. Geometric and thermal errors of machine tools should be measured and compensated to manufacture high quality products. In metal cutting, the machining accuracy is more affected by thermal errors than by geometric errors. This paper models of the thermal errors for error analysis and develops on-the-machine measurement system by which the volumetric error are measured and compensated. The thermal error is modeled by means of angularity errors of a column and thermal drift error of the spindle unit which are measured by the touch probe unit with a star type styluses and a designed spherical ball artifact (SBA). Experiments, performed with the developed measurement system, show that the system provides a high measuring accuracy, with repeatability of $\pm$2${\mu}{\textrm}{m}$ in X, Y and Z directions. It is believed that the developed measurement system can be also applied to the machine tools with CNC controller. In addition, machining accuracy and product quality can be improved by using the developed measurement system when the spherical ball artifact is mounted on the modular fixture.

  • PDF

Quality grading measure for online Digital Contents Vitalization (온라인 디지털 콘텐츠 활성화를 위한 품질 평가 척도)

  • Kim, Jonghyuk
    • Journal of Digital Contents Society
    • /
    • v.15 no.2
    • /
    • pp.309-317
    • /
    • 2014
  • This study developed contents quality grading measurement for helping contents developers, sales persons, consumers. After survey of 28 professionals and 89 contents related employees, this quality grading measurement was established. Also this quality grading measurement contains requirement of contents developers, sales persons, consumers by supporting detailed techical, contents, qualitative metadata.

Study of Power Quality Measurement U57 Windturbine (U57 풍력발전기 전력품질 실증연구)

  • Lee, Byung-Chul;Park, Hee-Chul;Hwang, Jin-Su;Ryu, Ji-June
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.310-314
    • /
    • 2008
  • The exploitation of the wind energy resource is a rapidly growing area world-wide. The number of installed units is continuously increasing, and it is important to respect and to deal with the impact of wind turbine. This paper addresses the power quality characteristics of U57 Wind Turbine. 750kW gearless type wind turbine for low wind speed, named U57, is developed by UNISON. The power quality measurement system consists of measuring WTG output current, line-to line voltage and wind speed signal. With using measured data, power quality measurement is evaluated about maximum power, reactive power, voltage fluctuation, harmonics according to IEC 61400-21.

  • PDF