• Title/Summary/Keyword: measurement point

Search Result 3,257, Processing Time 0.03 seconds

Improvement of Operating Stabilities in Organic Field-Effect Transistors by Surface Modification on Polymeric Parylene Dielectrics (Parylene 고분자 유전체 표면제어를 통한 OFET의 소자 안정성 향상 연구)

  • Seo, Jungyoon;Oh, Seungteak;Choi, Giheon;Lee, Hwasung
    • Journal of Adhesion and Interface
    • /
    • v.22 no.3
    • /
    • pp.91-97
    • /
    • 2021
  • By introducing an organic interlayer on the Parylene C dielectric surface, the electrical device performances and the operating stabilities of organic field-effect transistors (OFETs) were improved. To achieve this goal, hexamethyldisilazane (HMDS) and octadecyltrichlorosilane (ODTS), as the organic interlayer materials, were used to control the surface energy of the Parylene C dielectrics. For the bare case used with the pristine Parylene C dielectrics, the field-effect mobility (μFET) and threshold voltage (Vth) of dinaphtho[2,3-b:2',3'-f ]thieno[3,2-b]- thiophene (DNTT) FET devices were measured at 0.12 cm2V-1s-1 and - 5.23 V, respectively. On the other hand, the OFET devices with HMDS- and ODTS-modified cases showed the improved μFET values of 0.32 and 0.34 cm2V-1s-1, respectively. More important point is that the μFET and Vth of the DNTT FET device with the ODTS-modified Parylene C dielectric presented the smallest changes during a repeated measurement of 1000 times, implying that it has the most stable operating stability. The results could be meaned that the organic interlayer, especially ODTS, effectively covers the Parylene C dielectric surface with alkyl chains and reduces the charge trapping at the interface region between active layer and dielectric, thereby improving the electrical operating stability.

A vision-based system for long-distance remote monitoring of dynamic displacement: experimental verification on a supertall structure

  • Ni, Yi-Qing;Wang, You-Wu;Liao, Wei-Yang;Chen, Wei-Huan
    • Smart Structures and Systems
    • /
    • v.24 no.6
    • /
    • pp.769-781
    • /
    • 2019
  • Dynamic displacement response of civil structures is an important index for in-construction and in-service structural condition assessment. However, accurately measuring the displacement of large-scale civil structures such as high-rise buildings still remains as a challenging task. In order to cope with this problem, a vision-based system with the use of industrial digital camera and image processing has been developed for long-distance, remote, and real-time monitoring of dynamic displacement of supertall structures. Instead of acquiring image signals, the proposed system traces only the coordinates of the target points, therefore enabling real-time monitoring and display of displacement responses in a relatively high sampling rate. This study addresses the in-situ experimental verification of the developed vision-based system on the Canton Tower of 600 m high. To facilitate the verification, a GPS system is used to calibrate/verify the structural displacement responses measured by the vision-based system. Meanwhile, an accelerometer deployed in the vicinity of the target point also provides frequency-domain information for comparison. Special attention has been given on understanding the influence of the surrounding light on the monitoring results. For this purpose, the experimental tests are conducted in daytime and nighttime through placing the vision-based system outside the tower (in a brilliant environment) and inside the tower (in a dark environment), respectively. The results indicate that the displacement response time histories monitored by the vision-based system not only match well with those acquired by the GPS receiver, but also have higher fidelity and are less noise-corrupted. In addition, the low-order modal frequencies of the building identified with use of the data obtained from the vision-based system are all in good agreement with those obtained from the accelerometer, the GPS receiver and an elaborate finite element model. Especially, the vision-based system placed at the bottom of the enclosed elevator shaft offers better monitoring data compared with the system placed outside the tower. Based on a wavelet filtering technique, the displacement response time histories obtained by the vision-based system are easily decomposed into two parts: a quasi-static ingredient primarily resulting from temperature variation and a dynamic component mainly caused by fluctuating wind load.

Analysis of Minimum Detectable Activity Concentration of Water Samples and Evaluation of Effective Dose (물 시료의 최소검출가능 농도 분석과 유효선량 평가)

  • Jang, Eun-sung;Kim, Yang-su;Lee, Sun-young;Kim, Jung-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.857-862
    • /
    • 2020
  • In March 2011, a tsunami off Japan caused radioactive material that had seeped into the sea from the Fukushima nuclear accident to flow to the Pacific Ocean, causing pollution to sea life. For a comparative evaluation with the area surrounding the site of a nuclear power plant by the release of radioactive materials, an area 20 to 30 km away from the emergency protection plan area was selected as a comparative point considering weather conditions, population distribution, etc. In addition, the government intends to analyze the minimum detection radiation received by residents around the nuclear power plant and evaluate the effective dose. Analysis of tritium radiation from water samples showed that most of the samples were not detected and that 0.0014 % to 0.777 % of the annual legal standard of 1 mSv for the general public had little effect on the human body. Therefore, the measurement and analysis of water samples around the nuclear power plant site is expected to help relieve anxiety, such as exposure to the general public and neighboring residents due to radiation release.

Impacts of Relative Advantage of Fast Food Restaurant's O2O Service and Consumer Involvement on Consumer Engagement, and Store Loyalty: Focused on MZ Generationsin Untact Consumption Era

  • LEE, Young-Eun;LEE, Yong-Ki
    • The Korean Journal of Franchise Management
    • /
    • v.11 no.2
    • /
    • pp.41-51
    • /
    • 2020
  • Purpose: Fast food franchise companies are trying a variety of innovative services to increase their competitiveness in response to changes in population composition in the fast food market and rapid changes in consumption trends due to technological development. From this point of view, franchise companies that have focused on offline store operations are providing O2O (offline to online) service as a core service for customer convenience. This new attempt is a strategy to increase loyalty by applying an interaction method based on understanding the characteristics of new generation consumers. However, existing studies are focused on the relationship between O2O service and acceptance, so very little is known about how O2O service affects customer loyalty. Therefore, this study examines the impacts of customer involvement and relative advantages of fast food O2O service on customer brand engagement (cognitive and affective engagement) and store loyalty for MZ(Millennials - Z) generations. Research design, data, and methodology: In order to achieve the purposes of this research, several hypotheses were developed. The data were collected from 247 questionnaires in their 16-30s and were analyzed using SPSS 22.0 and SmartPLS 3.0 program. Measurement model analysis was carried out to assess convergent and discriminant validity. Also, common method bias was tested using the values of VIF (variance inflation factor). The hypotheses was tested using structural equation modeling. Result: First, involvement has a positive effect on cognitive and affective engagement. Second, relative advantages have has a positive effect on cognitive and affective engagement. Third, cognitive influences affective engagement. Finally, both cognitive and affective engagement affect store loyalty, but affective engagement has a stronger effect on store loyalty than cognitive engagement. Conclusions: In the process of consumer-brand interaction, it was confirmed that store loyalty was influenced by cognitive and affective engagement sequentially. However, the results show that affective engagement has a relatively stronger on store loyalty than cognitive engagement. Therefore, it is necessary to establish an O2O service strategy to maintain long-term loyal customers by inducing cognitive participation with high-involved consumer, as well as affective interaction, in order to obtain new customers and increase customer loyalty.

Paper Title of Validation of the Professional Identity for Occupational Therapist (국내 작업치료사의 전문직 정체성에 대한 타당성 연구)

  • Mun, Young-Ju;Jang, Jong-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.240-247
    • /
    • 2021
  • The purpose of this study was to identify the professional identity levels and characteristics of occupational therapists through Rasch analysis and to use this as the basis for further assessment and research on the same subject. An online survey was conducted, and the response of 88 people working as occupational therapists between May and June 2020 was analyzed. The collected data included the frequency, analyzed by SPSS 22.0 and technical statistics, Winsteps 3.8.0 target and item suitability, item difficulty, level scale, and separation reliability. According to the analysis, 17 (16.3%) of the subjects and 5 (20%) out of 25 items were unsuitable. Item difficulty was the highest in the category "I systematically read professional publications on occupational therapy", and the lowest level of difficulty in "I make my own decisions about what to do." The three-point scale was suitable for the equilibrium scale, and the separation reliability was between .86 and .95. Thus, identity levels and characteristics of occupational therapists, the suitability of items and subjects, and difficulty levels can be identified through Rasch analysis. In the future, research should be conducted on various sample groups, to develop identity measurement tools specifically for occupational therapists, and to present items appropriate to the characteristics of their work.

A Study on Lateral Displacement of Caisson Constructed on Improved Ground (개량 지반에 설치된 케이슨의 측방변위에 대한 연구)

  • Kim, Myunghak;Lee, Sangwook;Yoon, Minseung;Han, Byungwon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.4
    • /
    • pp.33-41
    • /
    • 2011
  • In case of building up port facilities on soft ground, unsymmetrical surcharge of embankment, which make the excess pore water pressure to increase, causes to occur lateral displacement due to plasticity of soil. A study on lateral displacement and settlement of the caisson, which is installed on improved ground, was accomplished. The field measurement data and calculated values obtained from FEM program of Plaxis were compared and analyzed. For numerical analysis, the properties of soils, constructions stage and time were considered. Lateral displacement was measured at the point of inclinometers installed in front of caisson. Settlement was measured at the center of extra embankment behind of caisson. Comparison of measured and calculated for lateral displacement showed that the calculated value was greater than the measured, and increasing trend was different. The calculated value showed step increasing as step extra embankment applied, whereas the measured gradually was increased. For settlement of embankment, the amount of both measured and calculated were similar, but the trend was different like that of lateral movement.

A Study on Ground Heave Characteristics of Soft Ground with DCM (DCM으로 개량된 연약점토지반의 지반융기에 관한 고찰)

  • You, Seung-Kyong;Hong, Gigwon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.19 no.4
    • /
    • pp.75-84
    • /
    • 2020
  • This paper described the analysis result on heaving of soft ground with DCM column type, based on the results of laboratory model tests on the soft ground with DCM column. The heave characteristics of the soft ground were evaluated according to the application of DCM column in soft ground. The results showed that the heaving of soft ground without DCM column occurred rapidly when the lateral deformation of soft ground increased significantly under the 4th load step condition. In addition, the heaving of soft ground in final load step caused tensile failure of the ground surface. The maximum heaving of the soft ground with the DCM column occurred in the final load step, and the heaving quantity decreased in the order of pile, wall, and grid type. Especially, the soft ground with DCM of grid type effectively resisted ground heaving, even if it was extremely failure in the bottom ground of embankment. The results of the maximum heaving according to the measurement point showed that the heaving of the soft ground with DCM of grid type was 3.1% and 1.6% compared to that of the pile and wall type at the location of LVDT-1, and the heaving of the LVDT-2 position was 1.0% and 2.1%, respectively.

Evaluation of Ventilation Performance of a Residential Unit for Different Sampling Points through Actual Field Tests (실증실험을 통한 측정 위치에 따른 주거공간 환기성능 평가)

  • Kwag, Byung Chang;Lee, Soo Man;Kim, Gil Tae;Kim, Jong Yeob
    • Land and Housing Review
    • /
    • v.13 no.3
    • /
    • pp.93-106
    • /
    • 2022
  • Ventilation plays an important role in controlling indoor air quality. Due to the recent spread of infectious diseases such as COVID-19 and with people spending more time indoors, there's been increased attention on the importance of ventilation performance. In many countries, ventilation is regulated by airflow rates and the number of air changes per hour (ACH). However, airflow rates and ACH alone do not provide an accurate account of actual indoor pollutant removal and ventilation uniformity in a space. This study looked into the ventilation performance of an actual residential unit using several sampling points instead of basing it off of airflow and air change rates. Literature review was used to derive relevant influencing factors and the tracer gas dilution method was used for the field test. The study measured air velocity, age of air, and ventilation efficiency at several locations and compared them to the average value at the center of the test space to determine the differences in ventilation performance at the selected measurement points. The study showed that different sampling locations resulted in different ventilation values. Findings of this study will be used to develop an experimental procedure for evaluating indoor ventilation performance of actual residential spaces.

Dose Distribution Study for Quantitative Evaluation when using Radioisotope (99mTc, 18F) Sources (방사성 동위원소 (99mTc, 18F) 선원 사용 시 인체 내부피폭의 정량적 평가를 위한 선량분포 연구)

  • Ji, Young-Sik;Lee, Dong-Yeon;Yang, Hyun-Gyung
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.5
    • /
    • pp.603-609
    • /
    • 2022
  • The dose distribution in the human body was evaluated and analyzed through dosimetry data using water phantom, ionization chamber and simulated by Monte Carlo simulation for 99mTc and 18F sources, which are frequently used in the nuclear medicine in this study. As a result of this study, it was found that the dose decreased exponentially as the distance from the radioisotope increased, and it particularly showed a tendency to decrease sharply when the radioisotope was separated by 5 cm. It means that a large amount of dose is delivered to an organ located within 4 cm of source's movement path when a source uptake in the human body. Numerically, it was formed in the rage of 0.16 to 2.16 pC/min for 99mTc and 0.49 to 9.29 pC/min for 18F. In addition, the energy transfer coefficient calculated using the result was found to be similar to the measured value and the simulation value in the range of 0.240 to 0.260. Especially, when the measured data and the simulation value were compared, there was a difference is within 2%, so the reliability of the data was secured. In this study, the distribution of radiation generated from a source was calculated to quantitatively evaluate the internal dose by radioisotopes. It presented reliable results through comparative analysis of the measurement value and simulation value. Above all, it has a great significance to the point that it was presented by directly measuring the distribution of radiation in the human body.

A Study on the Distribution and Reduction Method of Indoor Radon Concentration in Daejeon Metropolitan City (대전광역시 주택 실내 라돈 농도 분포와 저감 공법 적용 연구)

  • Jang, Yong-Chul;Yang, Jae Hwan;Kim, Hongkyoung;Lee, Gain;Song, Hakyun;Kim, Byeonghwan;Kwon, Youngsun
    • Journal of Environmental Impact Assessment
    • /
    • v.31 no.5
    • /
    • pp.286-295
    • /
    • 2022
  • In this study, the concentration distribution of indoor radon in Daejeon Metropolitan City was investigated and the reduction efficiency was evaluated by applying the radon reduction methods. Based on the results of the National Institute of Environmental Research, indoor radon measurements were conducted on 24 selected houses, and the average value of District A was 261 Bq/m3, far exceeding the standard, and even in the same house, indoor radon concentration was affected by measurement point and time. In the case of eight houses that applied the soil venting method to reduce radon, the indoorradon level was significantly lowerthan the standard value, and the average reduction efficiency was also around 55%, indicating a good reduction effect. In addition, the average reduction efficiency was around 90% in the two houses that carried out the shielding method, showing the very excellent effect of the indoorradon reduction. Even if the same reduction method is applied when reducing radon, the reduction efficiency may vary depending on various factors such as the structure of the building, the frequency of ventilation, and the season, so it is necessary to accurately evaluate the effectiveness of the reduction method in the future. Based on this, it is necessary to establish indoor radon management measures in Daejeon Metropolitan City to reduce human harm caused by radon exposure.