• 제목/요약/키워드: measurement method

검색결과 15,873건 처리시간 0.038초

Reliability and Validity of Angle of Trunk Rotation Measurement Using Smartphone and 3D Printing Technology in Scoliosis

  • Geum-Dong Shin;Seong-gil Kim;Kyoung Kim
    • The Journal of Korean Physical Therapy
    • /
    • 제34권6호
    • /
    • pp.283-291
    • /
    • 2022
  • Purpose: The purpose of this study was to compare and analyze the method of measuring the angle of the trunk rotation using a smartphone with 3D smartphone holder compared to a scoliometer, which is a measuring tool used as a method for diagnosing scoliosis in scoliosis patients. Methods: Angle of trunk rotation was measured in 21 subjects diagnosed with scoliosis. scoliometer measurement method, a smartphone measurement method with a 3D smartphone holder, a smartphone blind measurement method with a 3D smartphone holder, a smartphone measurement method without a smartphone holder, a smartphone blind measurement method without a smartphone holder, and a total of five measurement methods were repeated three times for comparison and analysis. Results: The smartphone measurement method with a 3D smartphone holder has excellent intra-rater reliability of angle of trunk rotation (Rater A; ICC3, 2≥0.993, Rater B; ICC3, 2≥0.992). The smartphone blind measurement method with a 3D smartphone holder has excellent inter-rater reliability of angle of trunk rotation (ICC2, 2≥0.968). The scoliometer measurement method had the highest validity (r=0.976) with the smartphone measurement method with a 3D smartphone holder, and the blind measurement method without a smartphone holder had the lowest validity (r=0.886). Conclusion: These findings, the angle of trunk rotation measured by the smartphone measurement method with a 3D smartphone holder in scoliosis patients showed high reliability and validity compared to the scoliometer measurement method.

3차원적 접근 방식을 통한 머리 부위 사진 측정법의 개발 (Development of the Photogrammetric Method of Head Through 3-Dimensional Approach)

  • 김웅;남윤자;김민효
    • 대한인간공학회지
    • /
    • 제24권4호
    • /
    • pp.7-13
    • /
    • 2005
  • We developed an accurate and reliable photogrammetric method available instead of the direct measurement method and the three-dimensional scanning method. Our research was restricted to a head on the body. Approaching three-dimensionally, we calibrated a distorted image of a photograph and got linear equations of camera beams. Then we assigned z values of landmarks in the head and obtained three-dimensional coordinates for each landmark putting those z values in linear equations of camera beams and finally could calculate measurement results from those three-dimensional coordinates. When we compared results obtained by a program, 'Venus Face Measurement(VFM)' that we had developed applying our method with results obtained by the direct measurement method, VFM showed very accurate and reliable results. In conclusion the photogrammetric method developed in this study was testified to an outstanding measurement method as a substitute for the direct measurement method and the three-dimensional scanning method.

Research on a Method for the Optical Measurement of the Rifling Angle of Artillery Based on Angle Error Correction

  • Zhang, Ye;Zheng, Yang
    • Current Optics and Photonics
    • /
    • 제4권6호
    • /
    • pp.500-508
    • /
    • 2020
  • The rifling angle of artillery is an important parameter, and its determination plays a key role in the stability, hit rate, accuracy and service life of artillery. In this study, we propose an optical measurement method for the rifling angle based on angle error correction. The method is based on the principle of geometrical optics imaging, where the rifling on the inner wall of the artillery barrel is imaged on a CCD camera target surface by an optical system. When the measurement system moves in the barrel, the rifling image rotates accordingly. According to the relationship between the rotation angle of the rifling image and the travel distance of the measurement system, different types of rifling equations are established. Solving equations of the rifling angle are deduced according to the definition of the rifling angle. Furthermore, we added an angle error correction function to the method that is based on the theory of dynamic optics. This function can measure and correct the angle error caused by the posture change of the measurement system. Thus, the rifling angle measurement accuracy is effectively improved. Finally, we simulated and analyzed the influence of parameter changes of the measurement system on rifling angle measurement accuracy. The simulation results show that the rifling angle measurement method has high measurement accuracy, and the method can be applied to different types of rifling angle measurements. The method provides the theoretical basis for the development of a high-precision rifling measurement system in the future.

The Volume Measurement of Air Flowing through a Cross-section with PLC Using Trapezoidal Rule Method

  • Calik, Huseyin
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권4호
    • /
    • pp.872-878
    • /
    • 2013
  • In industrial control systems, flow measurement is a very important issue. It is frequently needed to calculate how much total fluid or gas flows through a cross-section. Flow volume measurement tools use simple sampling or rectangle methods. Actually, flow volume measurement process is an integration process. For this reason, measurement systems using instantaneous sampling technique cause considerably high errors. In order to make more accurate flow measurement, numerical integration methods should be used. Literally, for numerical integration method, Rectangular, Trapezoidal, Simpson, Romberg and Gaussian Quadrature methods are suggested. Among these methods, trapezoidal rule method is quite easy to calculate and is notably more accurate and contains no restrictive conditions. Therefore, it is especially convenient for the portable flow volume measurement systems. In this study, the volume measurement of air which is flowing through a cross-section is achieved by using PLC ladder diagram. The measurements are done using two different approaches. Trapezoidal rule method is proposed to measure the flow sensor signal to minimize measurement errors due to the classical sampling method as a different approach. It is concluded that the trapezoidal rule method is more effective than the classical sampling.

유량계 교정장치의 측정불확도에 관한 연구 (A Study on the Measurement Uncertainty of Flowmeter Calibrator)

  • 임기원
    • 대한기계학회논문집B
    • /
    • 제25권4호
    • /
    • pp.561-571
    • /
    • 2001
  • The standard uncertainty of flowrate measurement is obtained by combining that of independent variables. Gravimetric and volumetric method were applied to determine the flowrate and the standard uncertainties of flowrate measurement by both methods were evaluated in accordance with the procedure recommended by International Organization for Standardization. The combined standard uncertainties of determining the flowrate were estimated from the sensitivity coefficient and the standard uncertainty of independent variables. For practical application, the methods for evaluating and expressing uncertainty in flow measurement were discussed. It was found that the uncertainties of the weighing and time measurement in gravimetric method, the volume and time measurement in volumetric method have dominant influence on that of flowrate measurement. With the quantitative analysis of the sensitivity coefficient, the contribution of the each variable uncertainty to the combined standard uncertainty of flowrate measurement is shown clearly.

자동차용 강판의 소성변형비 측정 방법 연구 (A Study on the Measurement Methods of Plastic Strain Ratio in Automotive sheet steel)

  • 김인수;김인수
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 1996년도 추계학술대회논문집
    • /
    • pp.85-92
    • /
    • 1996
  • The Measurement method of the plastic strain ratio is various in Automotive sheet steel. In this paper, the measurement of the plastic strain are used two different methods, ASTM E 517 method and the automatic strain measurement tensile specimen during the tensile test, and compared the plastic strain ratios from the two methods. The experimental results showed that the measured plastic strain ratios from the automatic strain measurement method are coincide with that from the ASTM E 517 standard measurement in various specimens. Therefore, automatic strain measurement method by two extensometers shows good accuracy. Also, the strain dependance of plastic strain ratios could be recorded by the computer continuously and anisotropy of the strength coefficient, K, and strain hardening exponent, n ,could be compared with each direction automatically through the use of automatic strain measurement system.

  • PDF

무전극 램프의 광특성 측정방식에 대한 고찰 (The Study of Measurement Method for an electrodeless lamp)

  • 이세현;조미령;신상욱;황명근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.68-71
    • /
    • 2003
  • In this paper, We have investigated the luminous flux, luminous efficacy, spectral energy distribution, colour rendering index, correlated colour temperature of electrodeless QL lamp system as a center method of measurement and side method of measurement. A result of measurement is that center method of measurement and side method of measurement is almost similar. Therefore, Sample that didn't measured because of big size and heavy weight can be measured by center method of measurement.

  • PDF

반전법을 이용한 축 직각도 측정방법 (Measurement of Axis Squireness by using Reversal Method)

  • 이창우;송준엽;하태호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.436-439
    • /
    • 2005
  • In general a square master and a dial gauge are used to measure the axis squareness on the spot. This method is a comparison measurement and its accuracy depends on the square accuracy wholly. Therefore the accuracy of a square master is very important and it is impossible that the accuracy of a square measurement is superior to the accuracy of a square master. In this paper, the new method of square measurement is proposed for measuring square without a square master and easily. This method is an absolute measurement by using a reversal method and can be used to measurement the accuracy of a square master.

  • PDF

A fast high-resolution vibration measurement method based on vision technology for structures

  • Son, Ki-Sung;Jeon, Hyeong-Seop;Chae, Gyung-Sun;Park, Jae-Seok;Kim, Se-Oh
    • Nuclear Engineering and Technology
    • /
    • 제53권1호
    • /
    • pp.294-303
    • /
    • 2021
  • Various types of sensors are used at industrial sites to measure vibration. With the increase in the diversity of vibration measurement methods, vibration monitoring methods using camera equipment have recently been introduced. However, owing to the physical limitations of the hardware, the measurement resolution is lower than that of conventional sensors, and real-time processing is difficult because of extensive image processing. As a result, most such methods in practice only monitor status trends. To address these disadvantages, a high-resolution vibration measurement method using image analysis of the edge region of the structure has been reported. While this method exhibits higher resolution than the existing vibration measurement technique using a camera, it requires significant amount of computation. In this study, a method is proposed for rapidly processing considerable amount of image data acquired from vision equipment, and measuring the vibration of structures with high resolution. The method is then verified through experiments. It was shown that the proposed method can fast measure vibrations of structures remotely.

피복구성학적 인체계측방법에 관한 연구 - 평면사진계측방법을 중심으로 - (A Study on the Plan Photogrammetry for Clothing Design)

  • 박찬미;서미아
    • 복식문화연구
    • /
    • 제5권1호
    • /
    • pp.151-164
    • /
    • 1997
  • This study pursues the problems of plan photogrammetry which is widely used in somatotyping at present, and find out a method which can improve accuracy of measurement on the basis of principles and mechanisms of photography-the basic foundation of the photographic analysis methods. As a result, this study proposes a new method which is based on the reference point method and perspective coordinate system. And the test measurement was operated to compare the measurement accuracy of the proposed method and the method based on reference grid screen method and perpendicular coordinate system which is commonly used at present. The result of this test measurement showed that the proposed method has higher accuracy. Two reasons can be pointed out for the improvement of measuring accuracy. The first reason is that the proposed perspective coordinate system reduces the perspective distortion of photography. And second reason is that measuring points can be closely placed to the scale and coordinate reference plan of measurement by the proposed reference point method which make possible to place measuring object (or person) at the center of scale and coordinate reference plan by utilizing reference points of measurement in the three dimensional space not on screen.

  • PDF