• Title/Summary/Keyword: measurement extraction

Search Result 578, Processing Time 0.035 seconds

Relationship among Chemical Properties of Soils with Different Texture Taken from Plastic Film House of Chungbuk Area (충북지역 시설재배지 토성별 토양화학성의 상호관계)

  • Kim, Jai-Joung;Kang, Seong-Soo;Kim, Ki-In;Hong, Soon-Dal
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.39 no.3
    • /
    • pp.144-150
    • /
    • 2006
  • Chemical characteristics and their interrelationships of 156 soils included by 74 sandy loam and 82 loam soils collected from plastic film house in Chungbuk area were investigated from 1998 to 2001. Seventeen chemical properties including pH, organic matter (OM), electrical conductivity (EC), inorganic nitrogen, available phosphorus, exchangeable cations, CEC, etc., were analyzed by correlation, standardized partial regression coefficient, and principal factor analysis. Standardized partial regression coefficients of chemical properties were estimated to determine the degree of contribution of EC and OM contents in soils. Principal factor analysis was applied to classify the studied chemical properties into different groups having similar chemical properties. The pH of experimental soils ranged from 4.24 to 7.14 and 4.95 to 7.35 for loam and sandy loam soils, respectively. The EC of soils varied from 0.93 to $15.65dS\;m^{-1}$ for loam and $0.91{\sim}22.30dS\;m^{-1}$ for sandy loam soils, respectively with significant differences among them. The EC measured by 1:5 $H_2O$ dilution method and saturation method were significantly related with 8.163 and 8.599 as the slopes of regression equation for loam and sandy loam soils, respectively. These slopes more than 8.0 in this regression equation was higher than the slope of 5.0 that is estimated from dilution coefficient suggesting that EC measured by 1:5 dilution method might be erratic. The standardized partial regression coefficient of different chemical properties for the estimation of EC was in the order of $NO_3{^-}$ > $Cl^-$ > OM > exchangeable Mg for loam soils and $NO_3{^-}$ > exchangeable Mg > $Cl^-$ for sandy loam soils. Contribution order of the chemical properties based on standardized partial regression coefficient differed 1:5 dilution method and saturation method, indicating that different chemical compounds might be present in the extract solutions of these two methods. Consequently the measurement of EC by saturation method was thought be still better for estimation of chemical property because accuracy of EC measurement by 1:5 dilution method can't be improved by any specific coefficient for adjustment of EC. Regardless of differences in soil textures and extraction methods, correlation coefficients between EC and the other chemical properties were routinely in the order of $NO_3{^-}$ > $Cl^-$ > degree of base saturation > exchangeable Mg > exchangeable Ca > $SO{_4}^{2-}$. The principal factor analysis revealed four factor groups of the chemical properties studied. The groups for sandy loam were as follows; ; 1. salt components, 2. soil reaction components, 3. fixed and adsorption components, 4. CEC components. The groupings of loam soils were similar to sandy loam except that exchangeable Na substituted the CEC of sandy loam.

Cellular Analysis and Measurement of Mucin in Sputum of Chronic Airway Disease (만성기도질환의 객담세포분석과 mucin의 측정)

  • Kim, Ki-Up;Kim, Yang-Ki;Shin, Chan-Young;Kim, Do-Jin;Uh, Soo-Taek;Kim, Yong-Hoon;Ko, Kwang-Ho;Park, Choon-Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.1
    • /
    • pp.82-92
    • /
    • 2000
  • Background : In chronic airway disease, mucus secretion is increased, but extraction of mucin, which is the main component of mucus secretion, is a very complicated and limited in clinical use. Recently, monoclonal antibody for mucin was developed for possible clinical use. In this study, cellular analysis and quantification of respiratory mucin in sputum of patients with chronic airway diseases were performed. Method : Sputum was collected from patients with asthma(n=33), bronchiectasis(n=8) or chronic bronchitis (n=13) by spontaneous expectoration or by hypertonic saline induction. Collected sputums was treated by 0.1% dithiotreitol to dissociate the disulfide bond of the mucus and filtered through a nylon gauze. Total cell count, viability and differential count were measured. For detection of mucin, collected samples were treated with sodium dodecyl sulfate polyacrylamide gel electrophoresis and then with monoclonal antibody(HMO2), as the primary antibody, and PAS stain. The amount of mucin was measured with ELISA by HMO2. Correlation with clinical information, cellular analysis, and amount of measured mucin were analyzed. Results : Total cell counts of sputum were significantly increased in patients with bronchiectasis but viability remained the same. Eosinophils were significantly increased in patients with asthma, neutrophils in bronchiectasis chronic bronchitis, respectively (p<0.05). The results of Western blotting and PAS staining confirmed the presence of glycoproteins and matched? with mucin. The amounts of mucin measured by ELISA were not significantly different among the disease groups. Significant correlation was identified between the amount of mucin and viability(r=-0.482, p<0.05). Conclusion : Inflammatory cells in the sputum of those with chronic airway disease were different for each disease type. Measurement of mucin by ELISA via monoclonal antibodies may be a simple method for the evaluation of chronic airway disease.

  • PDF

Single Laboratory Validation and Uncertainty Estimation of a HPLC Analysis Method for Deoxynivalenol in Noodles (면류에서 HPLC를 이용한 데옥시니발레놀 분석법의 검증과 불확도 산정)

  • Ee, Ok-Hyun;Chang, Hyun-Joo;Kang, Young-Woon;Kim, Mee-Hye;Chun, Hyang-Sook
    • Journal of Food Hygiene and Safety
    • /
    • v.26 no.2
    • /
    • pp.142-149
    • /
    • 2011
  • An isocratic high performance liquid chromatography (HPLC) method for routine analysis of deoxynivalenol in noodles was validated and estimated the measurement uncertainty. Noodles (dried noodle and ramyeon) were analyzed by HPLC-ultraviolet detection using immunoaffinity column for clean-up. The limits of detection (LOD) and quantification (LOQ) were 7.5 ${\mu}g$/kg and 18.8 ${\mu}g$/kg, respectively. The calibration curve showed a good linearity, with correlation coefficients $r^2$ of 0.9999 in the concentration range from 20 to 500 ${\mu}g$/kg. Recoveries and Repeatabilities expressed as coefficients of variation (CV) spiked with 200 and 500 ${\mu}g$/kg were $82{\pm}2.7%$ and $87{\pm}1.3%$% in dried noodle, and $97{\pm}1.6%$ and $91{\pm}12.0%$ in ramyeon, respectively. The uncertainty sources in measurement process were identified as sample weight, final volume, and sample concentration in extraction volume as well as components such as standard stock solution, working standard solution, 5 standard solutions, calibration curve, matrix, and instrument. Deoxynivalenol concentration and expanded uncertainty in two matrixes spiked with 200 ${\mu}g$/kg and 500 ${\mu}g$/kg were estimated to be $163.8{\pm}52.1$ and $435.2{\pm}91.6\;{\mu}g$/kg for dried noodle, and $194.3{\pm}33.0$ and $453.2{\pm}91.1\;{\mu}g$/kg for ramyeon using a coverage factor of two which gives a level of statistical confidence with approximately 95%. The most influential component among uncertainty sources was the recovery of matrix, followed by calibration curve.

Design and Implementation of Medical Information System using QR Code (QR 코드를 이용한 의료정보 시스템 설계 및 구현)

  • Lee, Sung-Gwon;Jeong, Chang-Won;Joo, Su-Chong
    • Journal of Internet Computing and Services
    • /
    • v.16 no.2
    • /
    • pp.109-115
    • /
    • 2015
  • The new medical device technologies for bio-signal information and medical information which developed in various forms have been increasing. Information gathering techniques and the increasing of the bio-signal information device are being used as the main information of the medical service in everyday life. Hence, there is increasing in utilization of the various bio-signals, but it has a problem that does not account for security reasons. Furthermore, the medical image information and bio-signal of the patient in medical field is generated by the individual device, that make the situation cannot be managed and integrated. In order to solve that problem, in this paper we integrated the QR code signal associated with the medial image information including the finding of the doctor and the bio-signal information. bio-signal. System implementation environment for medical imaging devices and bio-signal acquisition was configured through bio-signal measurement, smart device and PC. For the ROI extraction of bio-signal and the receiving of image information that transfer from the medical equipment or bio-signal measurement, .NET Framework was used to operate the QR server module on Window Server 2008 operating system. The main function of the QR server module is to parse the DICOM file generated from the medical imaging device and extract the identified ROI information to store and manage in the database. Additionally, EMR, patient health information such as OCS, extracted ROI information needed for basic information and emergency situation is managed by QR code. QR code and ROI management and the bio-signal information file also store and manage depending on the size of receiving the bio-singnal information case with a PID (patient identification) to be used by the bio-signal device. If the receiving of information is not less than the maximum size to be converted into a QR code, the QR code and the URL information can access the bio-signal information through the server. Likewise, .Net Framework is installed to provide the information in the form of the QR code, so the client can check and find the relevant information through PC and android-based smart device. Finally, the existing medical imaging information, bio-signal information and the health information of the patient are integrated over the result of executing the application service in order to provide a medical information service which is suitable in medical field.

A Cephalometric study on tooth movement pattern of maxillary 6 anteriors with double keyhole loops (Double keyhole loop에 의한 상악 6전치의 후방견인시 치아이동양상에 관한 측모두부방사선계측학적 연구)

  • Kim, Hyun-Kyung;Park, Young-Guk
    • The korean journal of orthodontics
    • /
    • v.32 no.1 s.90
    • /
    • pp.9-18
    • /
    • 2002
  • The present study hypothesized that the double keyhole looped archwire plays a positive role for the sake of translatory movement and/or controlled tipping of upper 6 anteriors, and secures anchorage control as well. The purposes of the study were to evaluate the changes in lateral cephalograms during orthodontic treatment with DKHLs and to compare the skeletal & dental changes before- & after-treatment. The materials of this study were lateral cephalograms of 20 adult patients with upper dentoalveolar protrusion both in class I and in class II Division1 malocclusion. Lateral cephalograms were taken before and after orthodontic treatment with upper 1st bicuspid extraction and DKHLs. The results were obtained as follows : 1. There were no statistically significant differences in skeletal measurement except SNB and PTFH between before- & after-treatment. The major changes were in dentoalveolar region. 2. After treatment, there were statistically significant decrease in dental measurement except interincisal angle. 3. Both upper & lower lip protrusion was decreased. 4. There were statistically differences in upper anterior crown horizontal & root vertical dimension(7.08 ${\pm}$ 2.14 mm, 2.38 ${\pm}$ 1.15 mm, p<0.01). 5. There were statistically differences in upper posterior dental(both crown & root) horizontal dimension(2.48 ${\pm}$ 0.99 mm, 2.05 ${\pm}$ 0.91 mm, p<0.01).

Body Composition Factor Comparisons of the Intracellular Fluid(ICW), Extracellular Fluid(ECW) and Cell Membrane at Acupuncture Points and Non-Acupuncture Points by Inducing Multiple Ionic Changes (생체이온 변화 유발 후 경혈과 비경혈에서의 생체 구조 성분 분석 및 비교를 통한 경혈 특이성 고찰)

  • Kim, Soo-Byeong;Chung, Kyung-Yul;Jeon, Mi-Seon;Shin, Tae-Min;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.31 no.2
    • /
    • pp.66-78
    • /
    • 2014
  • Objectives : The specificity of acupuncture point has been a highly controversial subject. Existing researches said that ion-distribution differences are observed on the acupuncture point. This study was conducted under the assumption that multiple ionic changes induced by muscle fatigue would be different between the acupuncture point with non-acupuncture point. Methods : To induce the identical fatigue, twenty subjects performed the knee extension/flexion exercise using the Biodex System 3. ST32 and ST33 as well as adjacent non-acupuncture points were selected. We measured blood lactate and analyzed the median frequency(MF) and peak torque. To obtain the information on the extracellular fluid(ECW), intracellular fluid(ICW) and cell membrane indirectly, we used the multi-frequency bioelectrical impedance analysis(MF-BIA) method. Results : MF, peak torque and blood lactate level of all measurement sites were gradually returned to normal. Re resistance of ST32 had a stronger response, but a non-acupuncture point adjacent to ST33 had a larger response up to 20 minutes post exercise. Ri resistances were similar for both acupoints and non-acupoints. The $C_m$ capacitance of ST32 had a stronger response after inducing fatigue, but ST33 had a smaller response than a non-acupuncture point adjacent to it. Conclusions : In comparison with before and after inducing fatigue, the specificity of acupuncture points was not clearly observed. Hence, we concluded that the body composition factors extraction method had the limitation as a method of finding the specificity of acupuncture points by inducing fatigue.

Establishment of Biotin Analysis by LC-MS/MS Method in Infant Milk Formulas (LC-MS/MS를 이용한 조제유류 중 비오틴 함량 분석법 연구)

  • Shin, Yong Woon;Lee, Hwa Jung;Ham, Hyeon Suk;Shin, Sung Cheol;Kang, Yoon Jung;Hwang, Kyung Mi;Kwon, Yong Kwan;Seo, Il Won;Oh, Jae Myoung;Koo, Yong Eui
    • Journal of Food Hygiene and Safety
    • /
    • v.31 no.5
    • /
    • pp.327-334
    • /
    • 2016
  • This study was conducted to establish the standard method for the contents of biotin in milk formulas. To optimize the method, we compared several conditions for liquid extraction, purification and instrumental measurement using spiked samples and certified reference material (NIST SRM 1849a) as test materials. LC-MS/MS method for biotin was established using $C_{18}$ column and binary gradient 0.1% formic acid/acetonitrile, 0.1% formic acid/water mobile phase is applied for biotin. Product-ion traces at m/z 245.1 ${\rightarrow}$ 227.1, 166.1 are used for quantitative analysis of biotin. The linearity was over $R^2=0.999$ in range of $5{\sim}60{\mu}g/L$. For purification, chloroform was used as a solvent for eliminating lipids in milk formula. The linearity was over 0.999 in range of 5~60 ng/mL. The detection limit and quantification limit were 0.10, 0.31 ng/mL. The accuracy and precision of LC-MS/MS method using CRM were 103%, 2.5% respectively. Optimized methods were applied in sample analysis to verify the reliability. All the tested milk formulas were acceptable contents of biotin compared with component specification and standards for nutrition labeling. The standard operating procedures were prepared for biotin to provide experimental information and to strengthen the management of nutrient in milk formula.

A Study on the Consumer's Service Quality Perception Based on the Types of Life-style (소비자의 라이프스타일에 따른 서비스품질 지각 차이에 관한 연구)

  • Park, Yoon-Seo;Lee, Seung-In;Choi, In
    • Journal of Global Scholars of Marketing Science
    • /
    • v.19 no.2
    • /
    • pp.53-67
    • /
    • 2009
  • For the last decades, service quality has been studied as one of the most important tools for a service company to compete with the other companies. Based on these past researches, it has been agreed that the service quality is a basic and powerful tool to create the competitive advantage. Due to similar reason, many service marketing practitioners have been also focused on the service quality to retain the existing consumers and collect the new consumers. However, service quality is subjectively perceived by individual consumers. Consumer evaluation of service quality can be different from each other. Especially consumers with one life-style may evaluate the service quality differently from the consumers with the other life-styles. Therefore we need to know whether there are differences in service quality perception on the categories of life-style. Life-style refers to a distinctive mode of living in its aggregate and broadest sense. It embodies the patterns that were developed and emerged from the dynamics of living in a society. Since the concept of life-style and its relationship to marketing was introduced in 1963 by William Lazer, methods of measuring the life-style and their application have been developed. Life-style has been usually used to segment the marketplace because it offers marketers a unique and important view of the market. When Life-style is combined with clustering methods, life-style segmentation can generate identifiable whole persons rather than isolated fragment. Life-style segmentation begins with people instead of products and classifies them into different life-style types, each characterized by a unique style of living based on a wide range of activities, interests, and opinions(Plummer, 1974). In this study we applies the life-style segmentation based on the AIO(Activities, Interests, and Opinions) to the consumers of the large discount stores. In Korea, the large discount store market has entered into maturity stage so that the market differentiation strategy is becoming a more critical issue to the marketing practitioners. One of the most important tools to differentiate from the competitors in large discount store market is continuously to provide service of better quality than competitors. This study tries to find answers about the following questions: 1) How can we categorize the consumer life-styles in the large discount store? 2) What are the characteristics of the categorized groups? 3) Are there any differences in service quality perception among the consumers with different life-styles 4) Are there any differences in consumer behavior among them in the large discount store? For the purpose, we collected survey data from consumers and analyzed the data with the SPSS package where we had $X^2$-test, factor analysis, ANOVA, MANOVA, and cluster analysis. The survey was made during one month in the April of 2008. Among the collected 306 copies of questionnaires, 281 copies were chosen as the effective samples for empirical analysis except 25 copies with wrong responses. To identify the life-style patterns, we used the measures employed by Kim and Kwon(1999), where 44 items on a seven-point scale were used to measure factors of the life-style patterns. The Principal Component Method was used for factor extraction, and the VARIMAX orthogonal factor rotation was employed. The 7 items showing low factor loading were eliminated. The results of the factor analysis suggested that nine factors of the life-style patterns were identified as follows: 1) the equality-of-sexes and pursuit-of-independence tendency 2) self-management tendency 3) sociable tendency 4) self-display tendency 5) degree of a dilettante life 6) pursuit-of-information tendency 7) bargain hunter tendency 8) TV preference tendency 9) pursuit-of-leisure tendency. Next, after the K-means cluster analysis was performed with nine factors of the life-style patterns, the life-styles of the respondents were classified into four groups which are named as the 'progressive practicality-oriented group', 'positive success-oriented group', 'sociable ostentation-oriented group', 'stable conservation-oriented group'. The analysis results for usage behavior between the market segments showed statistically significant differences in the frequency of usage, duration time in the store, consumer satisfaction, and loyalty. Also, we tried to investigate whether the large discount store consumers differently perceive the quality of service based upon the types of life-style. To measure the service quality of large discount store, we adapted several measurement models measuring the service quality such as SERVPERF, BCP, R-SERVPERF, R-BCP. MANOVA and One-Way ANOVA were performed to confirm the difference in service quality perception based on the market segments. The results have also shown significant differences between life-style types in service quality perception. These findings show that the large discount store marketers should consider consumer life-style as one of the most important market segments for marketing and understand the difference in service quality perception between life-style types. Our findings give important implications to marketers of large discount stores as well as life-style researchers. First, this study showed there were significant differences in consumer's service quality perception and usage behavior between the types of life-style. It provides evidence that the life-style approach can be a important basis in segmenting the large discount store market and will make consumers perceive the service quality high. Second, most previous researches on service quality have been in aggregate level. However, our results imply that the future research on service quality have to focus on segment level.

  • PDF

Analysis of Patients with Mandibular Nerve Damage after Root Canal Therapy (근관치료 후 발생한 하악신경 손상 환자에 대한 분석)

  • Lee, Ji-Soo;Song, Ji-Hee;Kim, Young-Gun;Kim, Seong-Taek
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.3
    • /
    • pp.327-336
    • /
    • 2011
  • Reported causes of mandibular nerve injury in relation to neuropathic pain in dentistry include extraction, dental implant surgery, oral and maxillofacial surgery, periodontal treatment, and root-canal therapy. This study analyzed the characteristics of pharmacologic management of neuropathy after root-canal therapy. 32 patients who complain of abnormal sensation or pain after root-canal therapy and were referred to Department of Oral Medicine and the Temporomandibular Joint and Orofacial Pain Clinic at the Dental Hospital of Yonsei University, Seoul, Korea from 2004 to 2011 enrolled in this analysis and improvement of symptom was evaluated after pharmacologic management. Thirty-two patients who had hypoesthesia or dysesthesia at the initial visit were analyzed(9 men, 23 women; mean age: 44 years). The causes of neuropathy were local anesthesia(46.9%), chemical trauma from the sealant in root-canal(25%), endodontic surgery(15.6%), and unknown causes(12.5%). Medications such as steroids, anticonvulsants, antidepressants, and analgesics were took for improvement of symptoms and titrated for a variety of period from 1 week to 11 months. It was found that neuropathy of the inferior alveolar nerve and the lingual nerve was in 25 and 7 patients. The improvement of neurosensory disturbance and no improvement after pharmacotherapy was in 21(66%) and 11(34%) patients respectively. The hypoesthesia and dysesthesia was improved 67% and 65% respectively. These results suggest that symptomatic improvement by pharmacologic management can be possible in patients with neuropathy after root-canal therapy. But improvement of symptoms was influenced by the causes and degree of nerve injury, the periods of pharmacotherapy, and the choice of treatment methods. So, further investigation is needed by quantitative measurement of more variables in more individuals.

Establishment of Choline Analysis in Infant Formulas and Follow-up Formulas by Ion Chromatograph (이온크로마토그래프를 이용한 조제유류 및 영아용·성장기용 조제식 중 콜린 함량 분석법 연구)

  • Hwang, Kyung Mi;Ham, Hyeon Suk;Lee, Hwa Jung;Kang, Yoon Jung;Yoon, Hae Seong;Hong, Jin Hwan;Lee, Hyoun Young;Kim, Cheon Hoe;Oh, Keum Soon
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.5
    • /
    • pp.411-417
    • /
    • 2017
  • This study was conducted to establish the analysis method for the contents of choline in infant formulas and follow-up formulas by ion chromatograph (IC). To optimize the method, we compared several conditions for extraction, purification and instrumental measurement using spiked samples and certified reference material (CRM; NIST SRM 1849a) as test materials. IC method for choline was established using Ion Pac CG column and 18 mM $H_2SO_4$ mobile phase. The parameters of validation were specificity, linearity, LOD, LOQ, recovery, accuracy, precision and repeatability. The specificity was confirmed by the retention time and the linearity, $R_2$ was over 0.999 in range of 0.5~10 mg/L. The detection limit and quantification limit were 0.14, 0.43 mg/L. The accuracy and precision of this method using CRM were 95%, 2.1% respectively. Optimized methods were applied in sample analysis to verify the reliability. All the tested products were acceptable contents of choline compared with component specification for nutrition labeling. The standard operating procedures were prepared for choline to provide experimental information and to strengthen the management of nutrient in infant formula and follow-up formula.