• Title/Summary/Keyword: measurement and record system

Search Result 78, Processing Time 0.027 seconds

Development of the Performance Measurement Model of Electronic Medical Record System - Focused on Balanced Score Card - (균형성과표를 활용한 전자의무기록시스템의 성과측정 모형개발)

  • Lee, Kyung Hee;Kim, Young Hoon;Boo, Yoo Kyung
    • Korea Journal of Hospital Management
    • /
    • v.21 no.4
    • /
    • pp.1-12
    • /
    • 2016
  • The purpose of this study are suggest to performance measurement model of Electronic Medical Record(EMR) and Key Performance Index(KPI). For data collection, 665 questionnaires were distributed to medical record administrators and insurance reviewers at 31 hospitals, and 580 questionnaires were collected(collection rate: 87.2%). Regarding methodology, Critical Success Factor(CSF) and index of the information system were derived based on previous studies, and these were set as performance measurement factors of EMR system. The performance measurement factors were constructed by perspective using BSC, and analysis on causal relationship between factors was conducted. A model of causal relationship was established, and performance measurement model of EMR system was proposed through model validation. Analysis on causal relationship between performance management factors revealed that utility cognition of the learning & growth perspective factor had causal relationship with job efficiency(${\beta}=0.20$) and decision support(${\beta}=0.66$) of the internal process perspective factors, and security had causal relationship with system satisfaction(${\beta}=0.31$) of the customer perspective factor. System quality had causal relationship with job efficiency(${\beta}=0.66$) and decision support(${\beta}=0.76$) of the internal process perspective factors, all of which were statistically significant(P<0.01). Job efficiency of the internal process perspective had causal relationship with system satisfaction(${\beta}=0.43$), and decision support had causal relationship with decision support satisfaction(${\beta}=0.91$) and job satisfaction (${\beta}=0.74$), all of which were statistically significant(P<0.01). System satisfaction of the customer perspective had causal relationship with job satisfaction(${\beta}=0.12$), job satisfaction had causal relationship with cost reduction(${\beta}=0.53$) of the financial perspective, and decision support satisfaction had causal relationship with productivity improvement(${\beta}=0.40$)of the financial perspective(P<0.01). Also, cost reduction of the financial perspective had causal relationship with productivity improvement(${\beta}=0.37$), all which were statistically significant(P<0.05). Suitability index verification of the performance measurement model whose causal relationship was found to be statistically significant revealed that $X^2/df=2.875$, RMR=0.036, GFI=0.831, AGFI=0.810, CFI=0.887, NFI=0.838, IFI=0.888, RMSEA=0.057, PNFI=0.781, and PCFI=0.827, all of which were in suitable levels. In conclusion, the performance measurement indices of EMR system include utility cognition, security, and system quality of the learning & growth perspective, decision support and job efficiency of the internal process perspective, system satisfaction, decision support satisfaction, and job satisfaction of the customer perspective, and productivity improvement and cost reduction of the financial perspective. In this study, it is expected that the performance measurement indices and model of EMR system which are suggested by the author, will be a measurement tool available for system performance measurement of EMR system in medical institutions.

The Development of Low Cost Power Components Measurement and Record System for Monitoring Electrical Equipment Operation Status (전력설비 동작 상태 감시를 위한 저가형 전력 성분 측정 및 기록 시스템의 개발)

  • Jeon, Jeong-Chay;Oh, Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.7
    • /
    • pp.4855-4862
    • /
    • 2015
  • This paper proposes low price power component measurement and record system for preventing electrical safety accident and supporting accident cause analysis by periodically monitoring and recording the operation status of electrical equipments. The proposed system was designed by mainly using parts to measure accurate power component but reduce cost. Especially, low cost and high effectiveness system implementation was possible by using MAXIM 78M6631 to calculate power components in the definition of IEEE Standard 1459-2010 related power quality. The measurement performance of the developed system is tested by using standard devices such as YOKOGAWA power analyzer WT1600. The test results showed that accuracy of the developed system is less than 0.5 % and the developed system is tested in a real area to verify the operation reliability and remote monitoring performance of the system over 6 months.

Development of Measurement System for the Underwater Explosion Shock Test of Naval Ships (함정의 수중폭발 충격시험을 위한 계측장비 시스템 개발)

  • 박일권;조대승;김종철
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.40 no.4
    • /
    • pp.66-74
    • /
    • 2003
  • In non-contact underwater explosion shock test of a real naval ship, measurement of shock loadings and responses should require onboard system to be able to safely trigger an explosive and to simultaneously and successfully measure scores of shock signals in the deteriorated environment. For this purpose, we have developed a shock-hardened measurement system resistible to 170g peak acceleration having 4 msec duration by resiliently mounting general purpose measurement instruments in racks. The system can simultaneously measure and record 200 signals to evaluate shock leadings and responses of the test ship by triggering an explosive and measurement instruments at the same time. We prove the performance of the developed system by introducing the signal acquisition results from of a real ship underwater shock test, firstly performed in Korea.

Automatic Guidance System for Tractor based upon Position-measurement Systems (위치(位置) 측정장치(測定裝置)를 이용한 트랙터의 자동(自動) 주행장치(走行裝置))

  • Choi, C.H.
    • Journal of Biosystems Engineering
    • /
    • v.15 no.2
    • /
    • pp.79-87
    • /
    • 1990
  • An automatic guidance system based upon two position-measurement systems was designed to record where the tractor traveled and to guide the tractor along the predetermined path. An algorithm, using the kinematic behavior of tractor movement, was developed to determine the steering angle to reduce lateral position error. The algorithm was based upon constant travel speed, constant steering rate, and zero slip angles of the tractor wheels. The algorithm was evaluated through use of computer simulation and verified in field experiments. Results showed that the distance interval between position measurements was an important factor in guidance system performance. The position-measurement error of the guidance system must be less than 5 cm to be acceptably precise for field operations. An algorithm based upon a variable steering rate might improve the stability of the guidance system. More accurate measurement of tractor position and yaw angle, and faster error processing are required to improve the field performance of the guidance system.

  • PDF

A Study on Pobeckchuck in the Middle period of Chosun Dynasty(Second) - Focusing on the History of Chosun Dynasty (조선시대(朝鮮時代) 중기(中期)의 포백척(布帛尺)에 관한 연구(硏究) - 조선왕조실록(朝鮮王朝實錄)을 중심으로 -)

  • Lee, Eun-Kyung
    • Korean Journal of Human Ecology
    • /
    • v.16 no.3
    • /
    • pp.623-630
    • /
    • 2007
  • The remarkable fact regarding the History of Chosun Dynasty(from Jungjong- Youngjo) is that any slightest evidence can't be found that Pobeckchuck was used to measure clothes or various Pobecks. There remains the document that in the 22nd years of Myeonjong, Japan required that Pobeckchuck be used, but it couldn't be allowed because of the reason it was made in the former king. This fact raises the high possibility that Pobeckchuck could be the most trustworthy standardized ruler at that time, and in other point of view, it can be presumed that the measurement in the period of King Sejong continued to have been used until this time. It can be seen that the length of one Chuck of Pobeckchuck at this time must have been equivalent to 46. 73cm of Pobeckchuck of Samchuck in the period of Sejong. In the History of Sunjo Period, many records on Pobeckchuck can be found, which fact seemed to have rectified the measurement system which was disordered by military revolt, though the reason is not clear. Also a record can be found that in the period of Sunjo, Chinese envoy required the Sunjo Regime to use Pobeckchuck for the measurement of copper pillar, which record supports the fact that Pobeckchuck is the standardized ruler. Another record that in the 26th period of Youngjo, Pobeckchuck of Samchuck was corrected according to the Kyeongkukdaejeon shows that the length of Pobeckchuck was 46.80cm at that time. Also, the record which rectified many rulers with the comparison of Hwangjong-chuck, Ju-chuck, Joryeki-chuck, Yongjo-chuck, etc. with one another reveals that the rulers used in the period of Sejong continued to have been used unchanged until in the period of Youngjo.

Development of Vehicle Clutch Discs Cushion Variation Measurement Device Using a Variable Load Electric Press (하중 가변형 전동 프레스를 이용한 차량용 클러치 디스크 쿠션 변위량 측정 장치 개발)

  • Park, Seung-Gyu;Choi, Hae-Woon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.6
    • /
    • pp.64-69
    • /
    • 2016
  • Vehicle clutch measurement for disc cushion variation was developed for the production of high quality Dual clutch transmissions. The developed device is composed of load cells for load measurement and LVDT for measuring the distance variation measurement in cushion variation. The servo motor-driven electric press for flexible loads that was developed was controlled by a PC-based HMI system, LabVIEW, and the device was able to continuously record real time measurement data with the accuracies of ${\pm}0.1\;kgf$ load and ${\pm}5{\mu}m$ cushion amount, which is far above the requirements of commercial vehicle standards.

Image and NFC based Real Time Reagent Measurement and Registration System (영상 및 NFC 기반 실시간 시약 계량 등록 시스템)

  • Lee, Keunwoo;cheong, Sangho;Jung, Hoekyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.6
    • /
    • pp.652-658
    • /
    • 2019
  • When IoT is applied to various research experiment fields such as physics, pharmacy, biology and medicine, it can increase the safety and convenience of researchers by intelligently monitoring and controlling research equipment and environment with various sensors and devices. For accurate and convenient record management and the research history and the basis but also for the reverse tracking, real-time reagent measurement and registration should be provided as a research support automation services. Currently, existing methods of reagent management are operated by computerized method, but reagent registration and management are not automated. And also record is managed manually, there are many hassles and problems such as a record error and too much time required for quantification and registration for many reagents. In this paper, we study a real time reagent measuring and registration method based on IoT to resolve the problems aforementioned, by the information of the reagent acquired by image recognition and NFC method.

Visibility Measurement in an Atmospheric Environment Simulation Chamber

  • Tai, Hongda;Zhuang, Zibo;Jiang, Lihui;Sun, Dongsong
    • Current Optics and Photonics
    • /
    • v.1 no.3
    • /
    • pp.186-195
    • /
    • 2017
  • Obtaining accurate visibility measurements is a common atmospheric optical problem, and of vital significance to civil aviation. To effectively evaluate and improve the accuracy of visibility measurements, an outdoor atmospheric simulation chamber with dimensions of $1.8{\times}1.6{\times}55.7m^3$ was constructed. The simulation chamber could provide a relatively homogeneous haze environment, in which the visibility varied from 10 km to 0.2 km over 5 hours. A baseline-changing visibility measurement system was constructed in the chamber. A mobile platform (receiver) was moved from 5 m to 45 m, stopping every 5 m, to measure and record the transmittance. The total least-squares method was used to fit the extinction coefficient. During the experiment conducted in the chamber, the unit weight variance was as low as $1.33{\times}10^{-4}$ under high-visibility conditions, and the coefficient of determination ($R^2$) was as high as 0.99 under low-visibility conditions, indicating high stability and accuracy of the system used to measure the extinction coefficients and strong consistency between repeated measurements. A Grimm portable aerosol spectrometer (PAS) was used to record the aerosol distribution, and then Mie theory was used to calculate the extinction coefficients. The theoretical results were found to be consistent with the measurements and exhibited a positive correlation, although they were higher than the measured values.

Measurement of weak magnetic signals using high-$T_c$ SQUID magnetometers in magnetically disturbed environment (High-$T_c$ SQUID 자력계를 이용한 자기잡음 환경에서의 미세자기신호 측정 및 분석)

  • 김인선;유권규;박용기
    • Progress in Superconductivity
    • /
    • v.4 no.2
    • /
    • pp.121-126
    • /
    • 2003
  • The single layer direct-coupled YBCO SQUID magnetometers have been fabricated and characterized for the purpose of the measurement of weak magnetic signals in unshielded environment. Two types of magnetometers have been designed and fabricated using 10 mm$\times$ 10 mm substrates. We could operate the conventional 3-mm-wide solid pickup loop magnetometers more stably than the 12-parallel-line pickup loop magnetometers in laboratory environment. We developed a first-order electronic gradiometer system using the SQUID sensors with axial displacement of 80 mm without any mechanical alignment of magnetometers. The system with a software filter using calculation of discrete Fourier transform could record clearly weak pulse signal of 100 pT in a magnetically disturbed environment.

  • PDF

Introduction of Management System Case Study on Standardization of Quality Record Management to Improve Quality Performance Rate of SMEs (경영시스템 도입 중소기업의 품질이행율 향상을 위한 품질기록 관리운영의 표준화 사례연구)

  • Cho, Chul-Hee;Park, Byeong Hwa;Park, Jini
    • Journal of Korean Society for Quality Management
    • /
    • v.47 no.4
    • /
    • pp.911-926
    • /
    • 2019
  • Purpose: In an infinite market competition, companies are adopting management systems to gain a competitive advantage. The expectancy effect of the management system is management performance improvement and accurate measurements. These can be made through quality records with integrity and maintainability. This paper examines the operation of records management standards, which are records, storage and management standards for quality records to understand the needs of records management standards and empathize with their needs. Methods: This paper examines PEC's (Pields Engineering Co., Ltd.) specific processes and standards for integrating individual management systems and establishing records management standards. We also look at the specific features of the Search Tool and Document Storage Management Standards that support records management standards. Results: The integration process of PEC's individual management system consists of five steps. A PDCA-based process was established to erode the confusion and inefficiencies caused by overlap between individual management systems. Also, by accurately grasping corporate competence, PEC established a record management standard suitable for the characteristics of the company. PEC's records management standards are used as a useful standard for organizing quality records, and have an impact on management performance improvement. Conclusion: PEC's records management standards enable the verification of quality performance rates and performance measures. Companies can implement appropriate quality improvement strategies based on the numbers identified by introducing records management standards. Companies can succeed in improving management performance when operating quality management that combines performance measurement techniques and records management standards.