• 제목/요약/키워드: measurement accuracy

검색결과 3,999건 처리시간 0.034초

열변형 오차를 고려한 기상측정 오차 보정에 관한 연구 (A study on the OMM error compensation considering the thermally induced errors)

  • 박규백;송길홍;조명우;권혁동;서태일
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.399-404
    • /
    • 2002
  • Improvement of measuring accuracy is an essential part of quality control manufacturing process. The OMM is less than the CMM in measure accuracy but the OMM system is more efficient, easier to use than other measurement system. About 40~70% of the machine tool errors are induced by the thermal errors. Therefore, a key requirement for improving the measuring accuracy is to reduce the geometric and thermal errors. Thermal errors are measured by a ball bar system and predicted by the thermal error modeling. Furthermore, using the pre-defined thermal error map approach compensates the geometric accuracy of the OMM. Appropriate experiments are performed using ball-bar system, temperature measuring devices and touch-type probe. Compensated results are compared with those obtained using CMM to verify the proposed methods.

  • PDF

고정밀 스핀들의 회전정밀도 측정 오차 분리법에 관한 연구 (A study on the Error Separation Method in Rotation Accuracy Measurement of High Precision Spindle Unit)

  • 김상화;김병하;진용규
    • 한국기계가공학회지
    • /
    • 제13권1호
    • /
    • pp.78-84
    • /
    • 2014
  • The rotation of a spindle unit must be accurate for high-quality machining and to improve the quality of the machine tools.Therefore, the proper measurement of the rotation accuracy and ensuring a proper analysis are very important. Separate processes are necessary because spindle errors and roundness errors associated with the test balls can both factor into the measured rotation error values. We used three methods to discern test ball errors and analyzed which could be deemed as the most proper technique in a test of the rotation accuracy of the main spindle of a machine tool.

전달 행렬을 이용한 강체 운동 측정의 정확도 개선 (Improving Accuracy of Measurement of Rigid Body Motion by Using Transfer Matrix)

  • 고강호;국형석
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.253-259
    • /
    • 2002
  • The rigid body characteristics (value of mass, Position of center of mass, moments and products of inertia) of mechanical systems can be identified from FRF data or vibration spectra of rigid body motion. Therefore the accuracy of rigid body characteristics is connected directly with the accuracy of measured data for rigid body motions. In this paper, a method of improving accuracy of measurement of rigid body motion is presented. Applying rigid body theory, ail translational and rotational displacements at a tentative point on the rigid body are calculated using the measured translational displacements for several points and transfer matrix. Then the estimated displacements for the identical points are calculated using the 6 displacements of the tentative Point and transfer matrix. By using correlation coefficient between measured and estimated displacements, we can detect the existence of errors that are contained in a certain measured displacement. Consequently, the improved rigid body motion with respect to a tentative point can be obtained by eliminating the contaminated data.

  • PDF

우량계 개발과 측정 오차 (Development of Rain Gauge and Observation Error)

  • 김대원;이부용
    • 한국환경과학회지
    • /
    • 제11권10호
    • /
    • pp.1055-1060
    • /
    • 2002
  • A new method of automatic recording raingauge is developed to measure rainfall 1200mm full scale with high accuracy and resolution. The principle of new instrument is to detect a weight change of a buoyant weight according to a change in water level of raingauge measured by the use of a strain gauge load cell. This method has the advantage of increasing measurement accuracy, since no moving equipment is used. Laboratory test of the instrument was recorded 0.4% error of 190mm rainfall amount. The validity of new instrument was examined by comparing its measured values with values recorded by automatic weather station on June 24 to 25 2001 at Daegu Meteorological Station, when there is 148.3mm rainfall amount. In spite of much rainfall there is only 0.77mm difference of total rainfall amount. This instrument was accomplished high accuracy and resolution at field test in much rainy day.

2차원 프로브에 의한 NC공작기계의 운동정밀도 측정 -제 1보 원호보간운동 정밀도 측정- (Measurement of motion accuracy by two-dimensional probe on NC machine tools -1st report, Measurement of the circular motion accuracy-)

  • 전언찬;소산전중덕;제정신
    • 한국정밀공학회지
    • /
    • 제13권3호
    • /
    • pp.56-62
    • /
    • 1996
  • This paper presented a new measuring system to improve circular motion accuracy by using two-dimensonal probe and master ring for NC machine tools. This measuring system reduced the circular motion error conspicuously by eliminating the influence of the acceleration/deceleration range and compensating the friction force whose influences were significant while measuring the motion. Experimental results show that this system had enough accuracy to measure a circular motion for NC machine tools, compared with the circular test method and the r .theta. method.

  • PDF

Antenna Measurement on Cylindrical Surface in Fresnel Region Using Direct Far-Field Measurement System

  • Oh, Soon-Soo;Kim, Joung-Myoun;Yun, Jae-Hoon
    • ETRI Journal
    • /
    • 제29권2호
    • /
    • pp.135-142
    • /
    • 2007
  • The small anechoic chambers built by many small-/medium-sized companies and universities present difficulties in testing electrically large antennas because the chamber size cannot satisfy the far-field criterion of large antennas. In this paper, a method for Fresnel-region measurement on a cylindrical surface with variation of the measurement height is proposed and verified by both calculations and experiments. We implement the proposed method using a direct far-field measurement system by adding a few supporting structures. The results show good accuracy.

  • PDF

간호대학생의 청력수준과 혈압측정의 정확도 (Nursing Students' Hearing Levels and Blood Pressure Measurement Accuracy)

  • 김희영;정영해;김윤희
    • 기본간호학회지
    • /
    • 제23권3호
    • /
    • pp.275-282
    • /
    • 2016
  • Purpose: This study was done to examine the relationship between nursing students' hearing levels and accuracy of blood pressure (BP) measurements. Methods: Participants were 107 students who had finished their fundamental nursing practice and clinical practicum and who used earphones. Data were collected from October 13 to November 30, 2014 and from April 30 to May 19, 2015. Students' hearing thresholds were examined using an audiometer. Students were assigned to take two BP measurements on BP measurement training simulators, but only the second measurement was used for analysis. Results: All nursing students' hearing levels were within normal range, and there was no significant difference found among the settings for diastolic blood pressure. However, there were significant differences between low systolic blood pressure (SBP) (below 120mmHg) and high SBP (over 140mmHg) (z=9.02, p=.011). Measurement error in SBP showed a positive correlation with hearing threshold in the right ear at frequencies of 1000Hz and 500Hz. Conclusion: Findings indicate that BP measurement error is correlated with hearing threshold at some frequencies. To reduce measurement error, nursing students should be provided with health education about hearing and to improve training for students, further studies need to examine other factors influencing BP measurement error.

위성체 얼라인먼트 측정 시스템에 관한 연구 (A Study on A Spacecraft Alignment Measurement System)

  • 박홍철;손영선;최종연;윤용식
    • 한국항공우주학회지
    • /
    • 제32권7호
    • /
    • pp.98-104
    • /
    • 2004
  • 위성체 얼라인먼트 측정은 측정 정밀도가 ${\pm}0.5^{\circ}$ 이하로 매우 정밀한 것이다. 일반적으로 이러한 측정은 3대 이상의 데오드라이트를 사용하여 측정되고 있다. 그러나 위성체의 위치 안정성 등에 의해 측정 정밀도 오차가 발생될 수 있다. 이에 따라, 데오드라이트, 회전 테이블 및 전자식 수평계 등을 조합하여 새로운 얼라인먼트 측정 시스템을 개발하게 되었다. 본 논문에서 이러한 측정 시스템의 개념과 측정 방법을 기술하였고, 기존의 측정 방법보다 더 좋은 정밀도를 얻을 수 있음을 알 수 있다.

Performance Analysis of Ranging Techniques for the KPLO Mission

  • Park, Sungjoon;Moon, Sangman
    • Journal of Astronomy and Space Sciences
    • /
    • 제35권1호
    • /
    • pp.39-46
    • /
    • 2018
  • In this study, the performance of ranging techniques for the Korea Pathfinder Lunar Orbiter (KPLO) space communication system is investigated. KPLO is the first lunar mission of Korea, and pseudo-noise (PN) ranging will be used to support the mission along with sequential ranging. We compared the performance of both ranging techniques using the criteria of accuracy, acquisition probability, and measurement time. First, we investigated the end-to-end accuracy error of a ranging technique incorporating all sources of errors such as from ground stations and the spacecraft communication system. This study demonstrates that increasing the clock frequency of the ranging system is not required when the dominant factor of accuracy error is independent of the thermal noise of the ranging technique being used in the system. Based on the understanding of ranging accuracy, the measurement time of PN and sequential ranging are further investigated and compared, while both techniques satisfied the accuracy and acquisition requirements. We demonstrated that PN ranging performed better than sequential ranging in the signal-to-noise ratio (SNR) regime where KPLO will be operating, and we found that the T2B (weighted-voting balanced Tausworthe, voting v = 2) code is the best choice among the PN codes available for the KPLO mission.

A Miniaturized Catadioptric Laser-Irradiation-Precision Test System

  • Liu, Huan;Sun, Hao;Wang, Chunyan
    • Current Optics and Photonics
    • /
    • 제5권2호
    • /
    • pp.164-172
    • /
    • 2021
  • In this paper a catadioptric laser-irradiation-precision test system is designed, to achieve a high-precision laser-irradiation-accuracy test. In this system, we adopt the method of imaging the entire target surface at a certain distance to realize the measurement of laser-irradiation precision. The method possesses the advantages of convenient operation, high sensitivity, and good stability. To meet the test accuracy requirement of 100 mm/km (0.01%), the coma, field curvature, and distortion over the entire field of view should be eliminated from the optical system's design. Taking into account the whole length of the tube and the influence of stray light on the structure type, a catadioptric system with a hood added near the primary imaging surface is designed. After optimization using the ZEMAX software, the modulation transfer function (MTF) of the designed optical system is 0.6 at 30 lp/mm, the full-field-of-view distortion is better than 0.18%, and the energy concentration in the 10-㎛-radius surrounding circle reaches about 90%. The illumination-accuracy test results show that the measurement accuracy of the radiation hit rate is better than 50 mm when the test distance is 1 km, which is better than the requirement of 100 mm/km for the laser-irradiation-accuracy test.