• Title/Summary/Keyword: measured displacement

Search Result 1,719, Processing Time 0.032 seconds

A Study On the Development of Multi-Purpose Measurement System for the Evaluation of Ship Dynamic Motion (선체 운동 평가를 위한 다기능 계측시스템 개발에 관한 연구)

  • kim Chol-seong;Jung Chang-hyun;Lee Yun-sok;Kong Gil-young;Lee Chung-ro;Cho Ik-soon
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2005.10a
    • /
    • pp.69-74
    • /
    • 2005
  • In order to evaluate the safety of navigation at sea and the safety of mooring on berthing, it is necessary that the wave and wind induced ship dynamic motion should be measured in real time domain for the validity of theoretical evaluation method sum as sea-keeping performance and safety of mooring. In this paper, the basic design of sensors is discussed and some system configurations were shown. The developed system mainly consists of 4 kind of sensors sum as three dimensional accelerator, two dimensional tilt sensor, two displacement sensors and azimuth sensor. Using this measuring system(MMS), it can be obtained the 6 degrees of freedom of ship dynamic motions at sea and on berthing sum as rolling, pitching, yawing, swaying, heaving, surging under the certain external forces.

  • PDF

Effects of Norepinephrine and Neuropeptide Y on the Contractility of Small Mesenteric Artery from 2K1C and DOCA-Salt Hypertensive Rats

  • Nam, Sang-Chae;Kang, Seong-Su;Kim, Won-Jae;Lee, Jong-Un
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.4 no.1
    • /
    • pp.55-61
    • /
    • 2000
  • The present study was conducted to investigate the possible role of the sympathetic nervous system in two-kidney, one clip (2K1C) and deoxycorticosterone acetate (DOCA)-salt hypertension. 2K1C and DOCA- salt hypertension were made in Sprague-Dawley rats. Four weeks after induction of hypertension, systolic blood pressure measured in conscious state was significantly higher in 2K1C $(216{\pm}18\;mmHg)$ and DOCA-salt $(205{\pm}29\;mmHg)$ groups than that in control $(128{\pm}4\;mmHg).$ The third branches (<300 ${\mu}m$ in outer diameter) of the mesenteric artery were isolated and cut into ring segments of $2{\sim}3$ mm in length. Each ring segment was mounted in tissue bath and connected to a force displacement transducer for measurement of isometric tension. The arterial rings were contracted by application of norepinephrine (NE) in a dose-dependent manner. The amplitude of the NE-induced contraction of the vessels was significantly larger in hypertension than in control. The NE-induced contraction was significantly enhanced by neuropeptide Y (NPY) in hypertension. Reciprocally, NPY-elicited vasocontraction was increased by NE in hypertension. These results suggest that the sympathetic nervous system contributes to the development of 2K1C and DOCA-salt hypertension.

  • PDF

The Effect of the Resistance of Wedge Frame on the Clamping Force of the Rail Clamp (쐐기프레임의 저항력이 레일클램프의 압착력에 미치는 영향)

  • Han Dong-Seop;Shim Jae-Joon;Lee Kwon-Hee;Han Geun-Jo
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2006.06b
    • /
    • pp.355-360
    • /
    • 2006
  • The damping force of a jaw pad is determined by the displacements of main part when two lockers are locked, after the damping angle of a locker was set up in the wedge type rail damp for a container crane. In this time, of the resistance of wedge frame generates due to several factors, the damping angle of a locker to display the initial clamping force will be changed because of the reduction of displacement of extension bar. This resistance is determined by the eccentric distance between the roller and the wedge, and by the gap between the wedge frame and outer frame. In this study we measured the tensile force of both extension bar through the performance test of the prototype rail damp in order to evaluate the effect of the resistance of wedge frame on the damping force of the wedge type rail clamp.

  • PDF

Bending Mode Multilayer Actuator Using Low Temperature Sintering Piezoelectric Ceramics (저온소결 세라믹을 이용한 밴더형 적층 액츄에이터의 제작)

  • Lee, Ju-Young;Kim, Sang-Jong;Kang, Chong-Yun;Kim, Hyun-Jai;Lee, Sang-Yoel;Yoon, Seok-Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.68-69
    • /
    • 2005
  • Low temperature ($\leq900^{\circ}C$) sintering piezoelectric ceramics $0.01Pb(Mg_{1/2}W_{1/2})O_3$-0.41Pb$(Ni_{1/3}Nb_{2/3})O_3-0.35PbTiO_3-0.23PbZrO_3+0.1wt%Y_2O_3+xwt%ZnO$ $(0{\leq}x{\leq}2.5)$ have been developed and investigated. The electromechanical coupling coefficient ($k_p$), piezoelectric constant ($d_{33}$), and mechanical quality factor ($Q_m$) have been measured to characterize the piezoelectric materials system. When 2.0 wt% ZnO is added, the properties of the system, $d_{33}$ = 559 pC/N, $k_p$ = 55.0 % and $Q_m$ = 73.4 are obtained which are very suitable for piezoelectric actuators. A bending mode multilayer actuator has been also developed using the materials which size is $27(L)\times9(W)\times1.07(t)mm^3$. The actuators are fabricated by multilayer ceramic (MLC) process and consist of24 layers and each layer thickness is $35{\mu}m$. At this time, the displacement of actuator was $100{\mu}m$ at 28V.

  • PDF

Assessment of Thermal Stress in Temporary Bridge (가교량의 온도응력 평가)

  • Park, Young Hoon;Lee, Seung Yong;Byun, Yun Joo;Chang, Dong Il
    • Journal of Korean Society of Steel Construction
    • /
    • v.10 no.1 s.34
    • /
    • pp.1-10
    • /
    • 1998
  • The temporary steel bridges which are constructed for detour and constructional expediency are consisted of H-beams(as superstructure) and H-piles(as substructure). Because these members are fastened by high-tension bolts, there are no expansion joints in these bridges. So, these kinds of bridges have no system which can relieve the excessive thermal stress. In this investigation, monitoring system was set up at temporary steel bridge and stress and temperature changes of H-beam are monitored. From these measured data, it is analyzed that the relationship between ambient and main-girder temperature change, between temperature and stress change. With these analyses, it is resulted that the thermal stress take main part of stress variation in this bridge and the restrain of thermal longitudinal displacement of H-pile. In addition, because the connection part of H-beam to H-beam is weak in the continuous spans, the sub-modelling is well apt to reflect the effect of thermal stress.

  • PDF

Rhizoma Coptidis INHIBITS HISTAMINE-INDUCED CONTRACTILE RESPONSES OF AIRWAY SMOOTH MUSCLE (기관지(氣管支) 평골절(平滑筋)에 미치는 황연(黃連)의 효과(效果))

  • O, Kwang-Soo;Han, Jong-Hyun
    • The Journal of Internal Korean Medicine
    • /
    • v.18 no.2
    • /
    • pp.83-93
    • /
    • 1997
  • Rhizoma Coptidis, a traditional herb medicine, has been used in Korea and China for many centuries as a treatment for many disease. The purpose of the present study was to determine the effect of Rhizoma Coptidis on histamine-induced tracheal smooth muscle contraction in guinea pigs and rats. Guinea pigs(500g, male) and rats(250g, male) were killed by $CO_2$ exposure and a segment (8-10mm) of the thoracic trachea from each guinea pig was cut into equal segments and mounted 'in pairs' in a tissue bath. Contractile force was measured with force displacement transducers under 0.5g loading tension. The dose of histamine which evoked 50% of maximal response ($ED_{50}$) was obtained from cumulative dose response curves for histamine ($10^{-7}-10^{-3}M$). Contractions evoked by histamine($ED_{50}$) were inhibited significantly by Rhizoma Coptidis. The mean percent inhibition was 33.2% after 1.5mg/ml Rhizoma Coptidis, and 69.5% after 5.0mg/ml Rhizoma Coptidis in guinea pigs, and the mean percent inhibition was 25.3% after 1.5mg/ml Rhizoma Coptidis, and 65.8% after 5.0mg/ml Rhizoma Coptidis in rats. Indomethacin ($10^{-7}M$) slightly but significantly attenuated the inhibitory effects of Rhizoma Coptidis. But propranolol and methylene blue ($10^{-7}M$) did not significantly alter the inhibitory effect of Rhizoma Coptidis. These results indicate that Rhizoma Coptidis can relax histamine-induced contraction of guinea pig and rat tracheal smooth muscle, and that this inhibition involves, in part, cyclooxygenese inhibitor.

  • PDF

Safety Evaluation of LB20304, a New Quinolone Antibiotic

  • Kim, Seong-Il;Kim, Hee-Jin;Kwak, Jin-Hwan;Kim, In-Chull;Lee, Chang-Ho
    • Biomolecules & Therapeutics
    • /
    • v.3 no.4
    • /
    • pp.322-326
    • /
    • 1995
  • General pharmacology of LB20304, a quinolone antibiotic, were examined in terms of general behaviour, cardiovascular, and central nervous system. LB20304 at oral dose of 2,000 mg/kg did not induce significant behavioural changes in mice. In contrast with ciprofloxacin, LB20304 at dose of 20 mg/kg, iv. did not show any observable effects on the blood pressure in rats. Displacement of [$^3$H]muscimol binding to the rat brain synaptic membranes was measured. LB20304 was shown to be about five times less potent than ciprofloxacin in specific GABA receptor binding. Drug interaction between LB20304 and 4-biphenyl acetic acid, an active metabolite of fenbufen, was assessed in mice by measuring convulsion and/or subsequent death. A single oral pretreatment with 4-BPA at 400 mg/kg increased the incidence of convulsion and death after oral administration of ciprofloxacin at the doses of 25, 50, and 100 from zero of five to three of five, two of five, and four of five, respectively, whereas LB20304 alone or combination with 4-BPA caused neither convulsions nor death at the doses of 12.5, 25, 50, and 100 mg/kg, respectively. Quinolones-induced epileptogenic activities were assessed by a direct intracerebral injection of test articles. The CD$_{50}$ values (nmole) are as follows; 169.47, 35.36, 105.29, and 88.67 for LB20304, ciprofloxacin, of loxacin, and lomefloxacin, respectively. From these data, LB 20304 at therapeutic doses seems to be much more safe than any other quinolones tested.d.

  • PDF

Evaluation of Micro Crack Using Nonlinear Acoustic Effect (초음파의 비선형 특성을 이용한 미세균열 평가)

  • Lee, Tae-Hun;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.4
    • /
    • pp.352-357
    • /
    • 2008
  • The detection of micro cracks in materials at the early stage of fracture is important in many structural safety assurance problems. The nonlinear ultrasonic technique (NUT) has been considered as a positive method for this, since it is more sensitive to micro crack than conventional linear ultrasonic methods. The basic principle is that the waveform is distorted by nonlinear stress-displacement relationship on the crack interface when the ultrasonic wave transmits through, and resultantly higher order harmonics are generated. This phenomenon is called the contact acoustic nonlinearity (CAN). The purpose of this paper is to prove the applicability of CAN experimentally by detection of micro fatigue crack artificailly initiated in Aluminum specimen. For this, we prepared fatigue specimens of Al6061 material with V-notch to initiate the crack, and the amplitude of second order harmonic was measured by scanning along the crack direction. From the results, we could see that the harmonic amplitude had good correlation with COD and it can be used to detect the crack depth in more accurately than the common 6 dB drop echo method.

Study of the Plating Methods in the Experimental Model of Mandibular Subcondyle Fracture (하악골 과두하부 골절 실험모델에서 견고정을 위한 플레이트 고정방법 연구)

  • Lee, Won;Kang, Dong Hee
    • Archives of Craniofacial Surgery
    • /
    • v.12 no.1
    • /
    • pp.12-16
    • /
    • 2011
  • Purpose: This study examined the biomechanical stability of four different plating techniques in the experimental model of mandibular subcondyle fracture. Methods: Twenty standardized bovine tibia bone samples ($7{\times}1.5{\times}1.0cm$) were used for this study. Each of the four sets of tibia bone was cut to mimic a perpendicular subcondyle fracture in the center area. The osteotomized tibia bone was fixed using one of four different fixation groups (A,B,C,D). The fixation systems included single 2.0 mm 4 hole mini adaption plate (A), single 2.0 mm 4 hole dynamic compression miniplate (B), double fixation with 2.0 mm 4 hole mini adaption plate (C), double fixation with a 2.0 mm 4 hole mini adaption plate and 2.0 mm 4 hole dynamic compression miniplate (D). A bending force was applied to the experimental model using a pressure machine (858 table top system, $MTS^{(R)}$) until failure occurred. The load for permanent deformation, maximum load of failure were measured in the load displacement curve with the chart recorder. Results: Double fixation with a 2.0 mm 4 hole mini adaption plate and a 2.0 mm 4 hole dynamic compression miniplate (D) applied to the anterior and posterior regions of the subcondyle experimental model showed the highest load to failure. Conclusion: From this study, double fixation with an adaption plate and dynamic compression miniplate fixation technique produced the greatest biomechanical stability. This technique may be considered a useful means of fixation to reduce the postoperative internal maxillary fixation period and achieve early mobility of the jaw.

Estimation of fracture toughness of cast steel container from Charpy impact test data

  • Bellahcenea, Tassadit;Aberkane, Meziane
    • Steel and Composite Structures
    • /
    • v.25 no.6
    • /
    • pp.639-648
    • /
    • 2017
  • Fracture energy values KV have been measured on cast steel, used in the container manufacture, by instrumented Charpy impact testing. This material has a large ductility on the upper transition region at $+20^{\circ}C$ and a ductile tearing with an expended plasticity before a brittle fracture on the lower transition region at $-20^{\circ}C$. To assess the fracture toughness of this material we use, the $K_{IC}$-KV correlations to measure the critical stress intensity factor $K_{IC}$ on the lower transition region and the dynamic force - displacement curves to measure the critical fracture toughness $J{\rho}_C$, the essential work of fracture ${\Gamma}_e$ on the upper transition region. It is found, using the $K_{IC}$-KV correlations, that the critical stress intensity factor $K_{IC}$ remains significant, on the lower transition region, which indicating that our testing material preserves his ductility at low temperature and it is apt to be used as a container's material. It is, also, found that the $J_{\rho}-{\rho}$ energetic criterion, used on the upper transition region, gives a good evaluation of the fracture toughness closest to those found in the literature. Finally, we show, by using the ${\Gamma}_e-K_{IC}$ relation, on the lower transition region, that the essential work of fracture is not suitable for the toughness measurement because the strong scatter of the experimental data. To complete this study by a numerical approach we used the ANSYS code to determine the critical fracture toughness $J_{ANSYS}$ on the upper transition region.