• 제목/요약/키워드: measured displacement

검색결과 1,719건 처리시간 0.029초

결함 상세를 포함하는 철근콘크리트 전단벽의 수치 모델에 관한 실험적 평가 (Experimental Assessment of Numerical Models for Reinforced Concrete Shear Walls with Deficient Details)

  • 전성하;박지훈
    • 한국지진공학회논문집
    • /
    • 제20권4호
    • /
    • pp.211-222
    • /
    • 2016
  • Reinforced concrete shear walls with deficient reinforcement details are tested under cyclic loading. The deficiency of reinforcement details includes insufficient splice length in U-stirrups at the ends of horizontal reinforcement and boundary column dowel bars found in existing low- to mid-rise Korean buildings designed non-seismically. Three test specimens have rectangular, babel and flanged sections, respectively. Flexure- and shear-controlled models for reinforced concrete shear walls specified in ASCE/SEI 41-13 are compared with the flexural and shear components of force-displacement relation extracted separately from the top displacement of the specimen based on the displacement data measured at diverse locations. Modification of the shear wall models in ASCE/SEI 41-13 is proposed in order to account for the effect of bar slip, cracking loads in flexure and shear. The proposed modification shows better approximation of the test results compared to the original models.

TA-ESPI에 의한 외팔보의 탄성계수 측정 (Evaluation of Young's Modulus of a Cantilever Beam by TA-ESPI)

  • 이항서;김경석;강기수;정현철;양승필
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1115-1119
    • /
    • 2005
  • The paper proposes the elastic modulus evaluation technique of a cantilever beam by vibration analysis based on time-average electronic speckle pattern interferometry (TA-ESPI) with non-contact and nondestructive and Euler-Bernoulli equation. General approaches for the measurement of elastic modulus of thin film are Nano indentation test, Bulge test and Micro-tensile test and so on. They each have strength and weakness in the preparation of test specimen and the analysis of experimental result. ESPI has been developed as a common measurement method for vibration mode visualization and surface displacement. Whole-field vibration mode shape (surface displacement distribution) at a resonance frequency can be visualized by ESPI. And the maximum surface displacement distribution from ESPI is a clue to find the resonance frequency at each vibration mode shape. And the elastic modules of test material can be easily estimated from the measured resonance frequency and Euler-Bernoulli equation. The TA-ESPI vibration analysis technique is able to give the elastic modulus of materials through the simple processing of preparation and analysis.

  • PDF

사면 변형 측정을 위한 3차원 레이저 스캐너의 적용 (Application of 3-D Laser Scanner for the Measurement of Slope Displacement)

  • 오석훈;서백수
    • 한국지구과학회지
    • /
    • 제31권6호
    • /
    • pp.555-562
    • /
    • 2010
  • 응력을 받고 있는 사면의 변형 여부를 분석하기 위해 3차원 레이저 스캐너를 이용하여 일정 기간의 차이를 두고 정밀 측량을 수행하였다. 3차원 레이저 스캐너는 비접촉식으로 레이저 빔의 주행시간을 이용하여 대상점의 3차원 좌표를 결정할 수 있는 장비로써, 사면이나 대형 구조물의 변위를 분석하는데 매우 유용한 장비이다. 스캐닝은 약 7개월의 시간차이를 두고 이루어졌으며, 측정간의 비교를 위해 사면의 외부에 기준점을 유지하여 사용하였다. 변형 여부를 판단하기 위해, 평면각 변화, 곡면도 변화, 격자 틀의 각도 변화, 공통 병합점의 편차 등을 분석하였다. 분석 결과, 사면의 변형이 특히 많이 발생한 지점을 결정할 수 있었고 이를 보수·보강 방안의 마련에 활용할 수 있었다.

광삼각법을 이용한 레이저 변위 센서의 특성 연구 (Characteristics of the Laser Displacement Sensor Using Optical Triangulation Method)

  • 박종성;정규원
    • 한국정밀공학회지
    • /
    • 제16권7호
    • /
    • pp.40-50
    • /
    • 1999
  • Recently, a laser displacement sensor is widely used for the manufacturing automation. The sensor is generally composed of a diode laser and a light receiving device. The diode laser emits a laser beam and the receiving device detects the light reflected from the measured object. The object position is obtained based upon triangulation method. As a light receiving device, a PSD is usually utilized since its structure is very simple and rugged and has a high accuracy. Although the theoretical relationship for this sensor had been developed, the characteristics of the sensor have not been much experimentally studied. In this paper, several experimental results will presented. The measurement accuracy is affected by the surface conditions such as the reflectance characteristics, the angle of the object's surface and the laser intensity. In addition, it is found that the PSD and the signal processing circuit have nonlinearities and showed that those nonlinearities can be reduced by controlling the emitting laser intensity.

  • PDF

임계값 설정에 따른 선형 단순화 알고리듬의 반응 특성 연구 (Performance Assessments of Three Line Simplification Algorithms with Tolerance Changes)

  • 이재은;박우진;유기윤
    • 한국측량학회지
    • /
    • 제30권4호
    • /
    • pp.363-368
    • /
    • 2012
  • 선형 단순화 알고리듬의 결과물은 단순화 알고리듬의 선택, 임계값의 선택, 대상 객체의 선택 등에 의해 달라진다. 본 연구에서는 Sleeve-fitting, Visvalingam-Whyatt, Bend-simplify 알고리듬의 임계값을 5단계로 조절하여 건물, 하천, 도로 객체에 적용하고, 단순화 결과물에 대해 거리오차, 면적오차, 각오차를 측정하였다. 그리고 오차값들의 추세선을 통해 정성적인 분석을 실시하였다. 실험 결과 선형 단순화 알고리듬에서 임계값의 조절에 따른 오차값의 변화를 알 수 있었고, 선형 단순화 알고리듬들의 임계값의 변화에 따른 특징을 파악할 수 있었다.

억지말뚝 흙막이공법에 설치된 복합버팀의 보강효과에 관한 실험적 연구 (An Experimental Study on the Reinforcement Effect of Installed composite stiffener on Earth Retaining Walls using Stabilizing Piles)

  • 김태효;임종철;박이근;권정근
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.1224-1239
    • /
    • 2008
  • The earth retaining walls using stabilizing piles can be applied to shallow excavation works without any stiffener. But, It demends a variety of installed composite stiffener on the earth retaining walls when it is installed as deep excavation works. Because, it causes an excessive displacement of walls. This research tried to overcome the problems created by the above issues and intended to apply the composite stiffener. The model test, focused on the effect of installed composite stiffener, measured the bending stress with stabilizing piles and walls, the settlement of earth surface, the displacement of walls for a step excavation and an increase in strip load. With the test results and soil deformation analysis, the reinforcement effect(relating to control displacement and earth presure) was analyzed in a qualitative and quantitative manner. It is expected to overcome a deep excavation works.

  • PDF

벌크 아몰퍼스 금속의 충격파괴 거동 평가를 위한 미소 샬피 시험편을 사용한 계장화 충격 시험법 (Instrumented Impact Test using Subsize Charpy Specimen for Evaluating Impact Fracture Behavior in Bulk Amorphous Metals)

  • 신형섭;고동균;정영진;오상엽;김문생
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.101-106
    • /
    • 2003
  • In order to investigate the mechanical behavior of newly developed materials, the evaluation of mechanical properties using small-size specimen is essential. For those purposes, an instrumented impact testing apparatus, which provides the load-displacement curve under impact loading without oscillations, was devised. To develop the test procedure with the setup, the impact behaviors of various kinds of structural materials such as S45C, SCM4, Ti alloys (Ti-6V-4Al) and Zr-based bulk amorphous metal, were investigated through the instrumented Charpy V-notch impact tests. The calibrations of the dynamic load and displacement that was calculated based on the Newton' second law were carried out through the quasi-static load test and the comparison of a directly measured value using a laser displacement meter. Satisfactory results could be obtained. The crack initiation and propagation processes during impact fracture could be well divided on the curve, depending on the intrinsic characteristic of specimen tested; ductile or brittle. The absorbed impact energy in Zr-basd BAM was largely used for crack initiation not for crack propagation process. The fracture surfaces under impact loading showed different feature when compared with the static cases.

  • PDF

초음속 디퓨져에서 충격파의 진동 (1) -수직충격파의 순간변위 측정- (Shock-Wave Oscillation in a Supersonic Diffuser -Displacement Measurement of Mormal Shock-Wave-)

  • 김희동;엄용균;권순범
    • 대한기계학회논문집
    • /
    • 제18권4호
    • /
    • pp.933-945
    • /
    • 1994
  • A shock-wave in a supersonic flow can be theoretically determined by a given pressure ratio at upstream and downstream flowfields, and then the obtained shock-wave is stable in its position. Under the practical situation in which the shock-wave interacts with the boundary layer along a solid wall, it cannot, however, be stable even for the given pressure ratio being independent of time and oscillates around a time-mean position. In the present study, oscillations of a weak normal shock-wave in a supersonic diffuser were measured by a Line Image Sensor(LIS), and they were compared with the data of the wall pressure fluctuations at the foot of the shock-wave interacting with the wall boundary layer. LIS was incorporated into a conventional schlieren optical system and its signal, instantaneous displacement of the interacting shock-wave, was analyzed by a statistical method. The results show that the displacement of an oscillating shock-wave increase with the upstream Mach number and the dominant frequency components of the oscillating shock-wave are below 200 Hz. Measurements indicated that shock-wave oscillations may not entirely be caused by the boundary layer separation. The statistical properties of oscillations appeared, however, to be significantly affected by shock-induced separation of turbulent boundary layer.

일반 구조용강 열간압연 박판에 대한 CTOD와 CTOA 곡선 결정 (Determination of CTOD & CTOA Curve for Structural Steel Hot-Rolled Thin Plates)

  • 이계승;이억섭
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.729-732
    • /
    • 2003
  • The K-R design curve is an engineering method of linear-elastic fracture analysis under plane-stress loading conditions. By the way, linear-elastic fracture mechanics (LEFM) is valid only as long as nonlinear material deformation is confined to a small region surrounding the crack tip. Like general steels, it is virtually impossible to characterize the fracture behavior with LEFM, in many materials. Critical values of J contour integral or crack tip opening displacement (CTOD) give nearly size independent measures of fracture toughness, even for relatively large amounts of crack tip plasticity. Furthermore, the crack tip opening displacement is the only parameter that can be directly measured in the fracture test. On the other. the crack tip opening angle (CTOA) test is similar to CTOD experimentally. Moreover, the test is easier to measure the fracture toughness than other method. The shape of the CTOA curve depends on material fracture behavior and, on the opening configuration of the cracked structure. CTOA parameter describes crack tip conditions in elastic-plastic materials, and it can be used as a fracture criterion effectively. In this paper, CTOA test is performed for steel JS-SS400 hot-rolled thin plates under plane-stress loading conditions. Special experimental apparatuses are used to prevent specimens from buckling and to measure crack tip opening angle for thin compact tension (CT) specimens.

  • PDF

PDMS를 이용한 마이크로 구동기의 제작 및 평가 (Detection of Tool Failure by Wavelet Transform)

  • 이동원;박종성
    • 한국기계가공학회지
    • /
    • 제7권2호
    • /
    • pp.72-77
    • /
    • 2008
  • In this study, we propose and develop PDMS-based modular actuators. The microactuator which looks like a small insect uses thermal expansion power of the PDMS (polydimethylsiloxane; $sylgar^{(R)}$ 184 silicone elastomer). The PDMS-based microactuator provides a large displacement due to a high thermal expansion coefficient (approximately 310ppm). The microacruator with 1mm length $350{\mu}m$ width is optimized by using a numerical analysis. The shape of the PDMS actuatoris variously designed. They are placed at several positions to find the optimal position that provides a high transformation ratio. The PDMS-based microactuators are fabricated using a conventional micromaching technique. The fabricated microactuator is heated using a hot-plate. The actuator displacement is measured as a function of temperature from $27^{\circ}C$ to $300^{\circ}C$. The experimental results are compared to the simulation result. When heating temperature up to $300^{\circ}C$ is applied to the PDMS actuator, each V-groove-shaped joint is actuated $30{\mu}$ mat $300^{\circ}C$. Anotherdesign of the microactuator has a maximum displacement of about 656mm.

  • PDF