• Title/Summary/Keyword: mean temperature

Search Result 3,941, Processing Time 0.032 seconds

Changes in Air Temperature and Its Relation to Ambulance Transports Due to Heat Stroke in All 47 Prefectures of Japan

  • Murakami, Shoko;Miyatake, Nobuyuki;Sakano, Noriko
    • Journal of Preventive Medicine and Public Health
    • /
    • v.45 no.5
    • /
    • pp.309-315
    • /
    • 2012
  • Objectives: Changes in air temperature and its relation to ambulance transports due to heat stroke in all 47 prefectures, in Japan were evaluated. Methods: Data on air temperature were obtained from the Japanese Meteorological Agency. Data on ambulance transports due to heat stroke was directly obtained from the Fire and Disaster Management Agency, Japan. We also used the number of deaths due to heat stroke from the Ministry of Health, Labour and Welfare, Japan, and population data from the Ministry of Internal Affairs and Communications. Chronological changes in parameters of air temperature were analyzed. In addition, the relation between air temperature and ambulance transports due to heat stroke in August 2010 was also evaluated by using an ecological study. Results: Positive and significant changes in the parameters of air temperature that is, the mean air temperature, mean of the highest air temperature, and mean of the lowest air temperature were noted in all 47 prefectures. In addition, changes in air temperature were accelerated when adjusted for observation years. Ambulance transports due to heat stroke was significantly correlated with air temperature in the ecological study. The highest air temperature was significantly linked to ambulance transports due to heat stroke, especially in elderly subjects. Conclusions: Global warming was demonstrated in all 47 prefectures in Japan. In addition, the higher air temperature was closely associated with higher ambulance transports due to heat stroke in Japan.

Selection of Main Air Temperature Factors on Annual Variation of Growth and Fruit Characteristics of Persimmon (감나무 생육 및 과실 특성의 연차 변이에 대한 주요 기온 요인 추출)

  • Jeon, Kyung-Soo;Kim, Ho-Cheol;Han, Jeom-Hwa;Kim, Tae-Choon
    • Journal of Bio-Environment Control
    • /
    • v.19 no.3
    • /
    • pp.165-170
    • /
    • 2010
  • This experiment was conducted to select the affected main factors on growth and fruit characteristics of 'Fuyu' persimmon (Diospyros kaki Thunb.) in 25 factors of air temperature factors in Naju. Mean air temperature, cumulative temperature and days for March and April of 25 factors were the highest annual variation. Number of the first and second principal components extracted from 25 air temperature factors were 14 and 3 factors related with mean temperature for annul and April, and cumulative contribution of these was 52.2%. Also the affected years by the first principal components were 1990, 1980 and 1986. Annual standard deviation on leafing, flowering and maturing date were 4.0~6.7 days range, and flowering date and days from leafing to flowering had the highest coefficient of variation. Annual variation of days from flowering to maturing date was affected by greatly mean air temperature and days of cumulative temperature in October, days from March 1 to leafing date was affected by cumulative temperature for growing period, days from leafing to flowering date was affected by mean air temperature in April. Annual variation of fruit weight was affected by mean air temperature for March and October.

Effect of Injection Temperature Condition on Root Mean Square and Peak-to-Valley of F-theta Lens (사출온도조건이 에프세타 렌즈의 표면조도와 표면형상에 미치는 영향에 관한 연구)

  • Park, Yong-Woo;Moon, Seong-Min;Lyu, Sung-Ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.6
    • /
    • pp.114-120
    • /
    • 2021
  • This study is focused on the root mean square and peak-to-valley based on the injection conditions of the f-theta lens, one of the main components of laser printers and laser scanning systems. The f-theta lens of an aspherical plastic lens requires ultra-preaction. Injection molding is typically used for the mass production of aspherical plastic lenses. In the injection-molding method, the resin in the lens shape is filled with the resin after melting the plastic pellets at a constant temperature and then cooled. It is necessary to maintain a uniform injection molding system to produce high-quality lenses. These injection-molding systems are influenced by different factors, such as pressure, speed, temperature, mold, and cooling. It is possible to obtain a lens that exhibits the optical characteristics required to achieve harmony. We investigated the root mean square and peak-to-valley caused by variations in temperature, a critical parameter in the melting and cooling of plastic resins generated inside and outside the injection mold.

The Relationship between Clothing Microclimate and Physiological Responses at $15^{\circ}C$ Environment ($15^{\circ}C$ 환경에서 의복기후와 인체생리반응과의 관련성)

  • Park, Joon-Hee;Choi, Jeong-Wha
    • Journal of the Korean Home Economics Association
    • /
    • v.46 no.4
    • /
    • pp.97-105
    • /
    • 2008
  • The objective of this study is to investigate the relationship between clothing microclimate and physiological responses, including subjective sensations, when, in a $15^{\circ}C$ environment, a range of temperatures inside clothing is broadly produced from using various combinations of upper and lower garments. Six male subjects participated in the investigation and the results were as follows. For all types of inside garments, the temperature of the clothing was lower than the skin temperature for the whole body in each case. The mean temperature for inside clothing ($\bar{T}_{cl}$) significantly showed the highest correlation with mean weighted skin temperature (r = 0.816) and was less positively correlated with the temperature of the inside clothing at the chest (r = 0.326) (p < .01). Values for both the energy expenditure and the heart rate were less positively correlated with the clothing microclimate (p < .01). The change of body heat content showed a negative correlation with the surface temperature of the innermost clothing (r = -0.519) and there was a difference between the innermost surface temperature and the outermost surface temperature of the clothing at the chest (r = -0.577). As td increased, the increase of body heat content declined (p < .01). There was a negative correlation between body fat and some of the temperatures inside the clothing (p < .01) and body fat had no significant correlation with the humidity inside the clothing. Subjective sensations were more highly correlated with $\bar{T}_{cl}$ than with the temperature of the inside clothing at the chest and had not significantly correlation with the humidity of the inside clothing. In conclusion, through these results, it can be seen that the temperature inside the clothing was related to various physiological responses and subjective sensations, and that the mean temperature of the inside clothing ($\bar{T}_{cl}$) showed a higher relationship with the temperature of the inside clothing at the abdomen than that at the chest.

A Study on Wearing Sensation in Accordance with difference in Materials of Aerobic Wear (에어로빅복의 소재 차이에 따른 착용감에 관한 연구)

  • 이미경;류숙희
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.22 no.1
    • /
    • pp.116-126
    • /
    • 1998
  • This study was conducted to examine the effect of difference in materials of aerobic wear on both human body's physiological reactions and subjective wearing sensation by comparing and analysing not only cotton sparidex A, B and C but nylon spandex D, E and F used as actually wearing materials. The rectal temperature of type A and I remained at high degree, the type C was higher from after high-speed running but dropped sharply when taking a break finally. Both skin temperature and mean skin temperature dropped sharply due to sweat occurred during physical exercise, and then rose slowly when taking a break. Type A -D and B-I showed that the mean skin temperature remained at high degree when wearing a cotton spandex. Type C's temperature within its aerobic wear was lower than type F while its relative humidity was higher than type F. Wearing sensation showed a change similar to wearing, particularly, which was remarkable in type B-E. Also, it was shown that humidity sensation, tactile sensation and comfort sensation were good when wearing the cotton spandex.

  • PDF

Implications of Temperature and Humidity on Pupation Patterns in the Silkworm, Bombyx mori L.

  • Lakshminarayana, P.;Naik, S.Sankar;Reddy, N.Sivarami
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.5 no.1
    • /
    • pp.67-71
    • /
    • 2002
  • The implications of temperature (25,30 and 35$^{\circ}C$) and relative humidity (60, 70 and 80%) on the pupation patterns were studied in the silkworm, Bombyx mori L. Larvae of two pure silkworm breeds, Pure Mysore (PM) and NB4D2 and their hybrid, PM ${\times}4 NB4D2 were reared under experimental conditions under natural day photoperiodic (LD 12: 12) condition. The three developmental marker events viz., larval ripening, pharate pupal formation and pupal formation occurred at or around the beginning of the photo-phase. The computed of mean vector (equation omitted), based on the circular statistics, also confirmed the above. However, the length of mean vector, r and the mean vector angular variance, s varied according to temperature and humidity conditions imposed; the variations being non-significant. Extreme temperature and humidity conditions, however, resulted in reduction in pupation rate (%) for PM and PM ${\times}4 NB4D2. On the other hand, in NB4D2 pupation percentage reduced below the economic level. The temperature and humidity together seems to exert synergic impact on the pupation rate at least in the silkworm Bombyx mori, L.

The Relationships between Weather Factors and Photosystem II Activity in Three Cool-season Turfgrasses in Summer (한지형 잔디 3종의 하절기 광계II 활성과 기상요인과의 상관성)

  • Koh, Seok Chan
    • Journal of Environmental Science International
    • /
    • v.31 no.4
    • /
    • pp.311-318
    • /
    • 2022
  • In this study, we analyzed the relationships between weather factors and photosystem II activity (Fv/Fm), as a measure of photochemical efficiency, in three cool-season turfgrasses commonly planted on golf courses in Jeju, South Korea: perennial ryegrass (Lolium perenne L.), Kentucky bluegrass (Poa pratensis L.), and creeping bentgrass (Agrostis palustris Huds.). In all three turfgrasses, Fv/Fm was higher during late summer than during early summer. However, in late summer, Fv/Fm was significantly lower in perennial ryegrass than in the other two species. In early summer, Fv/Fm in perennial ryegrass and Kentucky bluegrass was positively correlated with mean low temperature and extreme minimum temperature, whereas, in late summer, this parameter in Kentucky bluegrass and creeping bentgrass was positively correlated with relative humidity, and in creeping bentgrass was negatively correlated with mean high temperature, mean low temperature, and extreme maximum temperature. These results indicate that raising low temperatures is favorable for perennial ryegrass and Kentucky bluegrass in early summer, whereas, in late summer, the lowering of high temperatures proves to be beneficial for creeping bentgrass, and raising relative humidity is conducive to the growth of Kentucky bluegrass and creeping bentgrass. These findings will contribute to improving the selection and management of turfgrasses on golf courses and sports fields.

Periodic Variations Of Water Temperature In The Seas Around Korea(II). Annual And Long Term Variations Of Surface Water Temperature In The Regions Of Mishima And Okinoshima (한국 근해 수온의 주기적 변화(II). 삼도와 중지도 해역 표면수온의 년주변화 및 장주기 변화)

  • Hahn, Sangbok
    • 한국해양학회지
    • /
    • v.5 no.2
    • /
    • pp.41-51
    • /
    • 1970
  • Periodic characters of water temperature in the regions of the Mishima and the Okinoshima were derived through the analysis of the five days interval data during 1914 to 1970 mainly. In terms of ten days mean temperatures, annual variation function of the Mishima region, Korea Strait, is F($\theta_d$)=17.45-5.34 cos $\theta_d$-3.77 sin $\theta_d$+0.62 sin $2\theta_d$ -0.52 sin $3\theta_d$, where $\theta_d$=$\frac{\pi}{18}$(d-2), d is the order of ten days period 1 to 36. And in the region of Okinoshima, Tsushima Strait, we find F($\theta_d$)=18.88-5.39 cos $\theta_d$-3.60 sin $\theta_d$+0.52 sin $2\theta_d$. The annual mean temperature is 17.4$^{\circ}C$ in the Mishima region, 18.9$^{\circ}C$ in the Okinoshima region, and the amplitudes of annual variation functions are 7$^{\circ}C$ in both regions with minimum temperature in the middle ten days of February, maximum in the middle ten days of August. The long term variations of surface water temperature with 12 5 years period were observed in the annual mean temperature, monthly mean temperatures and the fixed day temperatures of every year. In addition to these, relatively short term variations were also found significant periods of 3 years, 4 years and 2 years, respectively.

  • PDF

COMPARATIVE EXPERIMENTAL STUDY ON MEASUREMENT OF ORAL TEMPERATURE WITH DIFFERENT KINDS OF CLINICAL THERMOMETERS -comparison of Oral Temperature and Oral Placement Time among Fahrenheit Glass Thermometer, Electric Thermometer, Yu II centigrade Glass Thermometer, and Kuk II centigrade Glass Thermometer- (각종 체온계의 구강체온측정에 관한 실험적 비교연구 -외제화씨 체온계, 전자체온계 및 국산 섭씨체온계에 의한 측정온도와 측정시간의 비교-)

  • 윤정숙
    • Journal of Korean Academy of Nursing
    • /
    • v.4 no.2
    • /
    • pp.93-106
    • /
    • 1974
  • The purposes of this study are to identify the necessity of utilization of electric thermometer, to determine the difference of clinical thermometers to reach maximum or optimum temperature, and to determine the length of time necessary for temperature taking, with Fahrenheit thermometer, electric thermometer, Yu Ⅱ centigrade thermometer, and Kuk ll centigrade thermometer. The first and second comparative Experiments were' conducted from August 25 through September 30, 1973. In the first experiment, Fahrenheit thermometer, which had been accurately teated two times, and electric thermometer have been utilized. These two kinds of thermometers were inserted simultaneously under the central area of the tongue and the mouth kept closed while thermometers were in place. All temperature readings were done at one minute interval until leaching-maximum temperature. These procedures were repeated one hundred times and the data were-analyzed statistically by means of the t-test. In the second experiment, Fahrenheit thermometer, which had been accurately tested two. times, Yu Ⅱ centigrade thermometer, and Kuk Ⅱ centigrade thermometer have been utilized. These three kinds of thermometers were inserted simultaneously under the central area of the. tongue and the mouth kept closed while thermometer were in place. All temperature readings were done at one minute interval until reaching maximum temperature. These procedures were. repeated one hundred times and the data were analyzed statistically by means of the F-ratio Under the eight hypotheses designed for this study, the findings obtained are as follows: 1. There were no significant differences in the maximum temperature between Fahrenheit thermometer and electric thermometer. The mean maximum temperature for Fahrenheit thermometers was 37.06℃ and for electric thermometer was 37.09℃. 2. The placement time to reach maximum temperature taken by Fahrenheit thermometer was significantly shorter than that by electric thermometer. The mean placement time for Fahrenheit thermometers was 4.04 minutes, for electric thermometer was 5.52 minutes. In the case of Fahrenheit thermometers, 45 to 77 percent after 3 to 5 minutes, over 90 Percent after 7 minutes, and 100 percent after 10 minutes, had reached optimum temperature. When the electric thermometer was used, 23 to 54 percent after 3 to 5 minutes, over 90 percent after 9 minutes, and 100 percent after 12 minutes, had reached optimum temperature. 5. There ware no significant differences in the maximum temperature among Fahrenheit thermometer, Yu Ⅱ centigrade thermometer, and Kuk Ⅱ centigrade thermometer. The mean maximum temperature for Fahrenheit thermometers was 36.67℃, for Yu Ⅱ centigrade thermometer, was 33.73℃, and for Kuk Ⅱ centigrade thermometers was 37.76℃. 6. There were no significant differences in placement time to reach maximum temperature among Fahrenheit thermometer, Yu Ⅱ centigrade Thermometer, and Kuk Ⅱ centigrade thermometer. The mean placement time (or Fahrenheit thermometers was 7.77 minutes, for Yu Ⅱ centigrade thermometers was 7.25 minutes, and Kuk Ⅱ centigrade thermometers was 7.25 minutes. In the case of Fahrenheit thermometers, 8 to 24 percent after 3 to 5 minutes, over 90 percent after 11 minutes, and 100 percent after 13 minutes, had reached maximum temperature. When the Yu Ⅱ centigrade thermometer was used, 10 to 27 percent after 3 to 5 minutes, over 90 percent after 11 minutes, an8 103 percent after 13 minutes, had reached maximum temperature. When the Kuk Ⅱ centigrade thermometer was used, 11 to 27 Percent after 3 to 5 minutes, over 90 percent after 11 minutes, and 100 percent after 12 minutes, had reached maximum temperature. 7. There were no significant differences in the optimum temperature(the maximum temperature minus 0.1℃) among fahrenheit thermometer, Yu Ⅱcentigrade thermometer, and Kuk Ⅱ centigrade thermometer. The mean optimum temperature for Fahrenheit thermometers was 36.60℃, for Yu Ⅱ centigrade thermometers was 36.69℃, and Kuk Ⅱ centigrade thermometers was 36.69℃. 8. There were no significant differences in placement time to reach optimum temperature among Fahrenheit thermometer, Yu Ⅱ centigrade thermometer, and Kuk Ⅱ centigrade thermometer The mean placement time for Fahrenheit thermometers was 5.70 minutes, for Yu Ⅱ centigrade thermometers was 5.54 minutes, and for Kuk Ⅱ centigrade thermometers was 5.28 minutes. In the case of Fahrenheit thermometers, 21 to 49 percent after 3 to 5 minutes, over 90 percent after 9 minutes, and 100 percent after 12 minutes, had reached optimum temperature. When the Yu Ⅱ centigrade thermometer was used, 23 to 51 percent after 3 to 5 minutes over 90 percent after 10 minutes, and 100 percent after 12 minutes, had reached optimum temperature. When the Kuk Ⅱ centigrade Thermometer was used, 23 to 57 Percent after 3 to 5 minutes, over 90 percent after 9 minutes, and 100 Precent after 11 minutes, had reached optimum temperature.

  • PDF

Flap Monitoring by Infra-red Thermometer (적외선 고막 체온계를 이용한 피판감시)

  • Kirk, Insoo;Hong, Joon-Pio
    • Archives of Reconstructive Microsurgery
    • /
    • v.13 no.1
    • /
    • pp.82-85
    • /
    • 2004
  • Flap monitoring is important for flap salvage. Although there are many methods to observe the flap, practical methods mostly used are subjective methods. Recording flap surface temperature is one of the objective methods of flap monitoring. We used an infra-red thermometer to simplify monitoring of the flap temperature. 60 groin flaps of SD rats are used in the experiment. Artificial arterial or venous insufficiency was made and the surface temperature was checked and compared with body temperature. In the results, the temperature of the arterial clamped flaps was lower than that of body and the mean difference was $0.3^{\circ}C$ after 20 minutes of clamping. In the vein-clamped flaps, the mean decrease was $0.4^{\circ}C$ after 30 minutes of clamping. The all difference of the temperature between the flaps and body was statistically significant. Our results suggest that flap monitoring by infra-red thermometer is simple, useful and helpful to evaluate the flap status.

  • PDF