Leak Detection Technique of Pressure Vessel Using Acoustic Emission Signal (음향방출 신호를 이용한 압력용기의 누설 검사기법 개발)

  • 이성재;정연식;강명창;김정석
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.4
    • /
    • pp.95-99
    • /
    • 2004
  • In this study, the leak detection technique of pressure vessel by using acoustic emission(AE) signal is suggested experimentally. The leak of pressure vessel is located at the welding line due to welding defects. we measured the AE signal using Rl5I sensor, and examined the AE parameters in leak condition. It is investigated that the mean value of AE signal is dependent on leak source location. So the absolute mean value of AE signal is adopted as dominant AE parameter. We proposed leak detection algorithm using AE signal mean value for monitoring the leak source location.

Bayesian Inferences for Software Reliability Models Based on Beta-Mixture Mean Value Functions

  • Nam, Seung-Min;Kim, Ki-Woong;Cho, Sin-Sup;Yeo, In-Kwon
    • The Korean Journal of Applied Statistics
    • /
    • v.21 no.5
    • /
    • pp.835-843
    • /
    • 2008
  • In this paper, we investigate a Bayesian inference for software reliability models based on mean value functions which take the form of the mixture of beta distribution functions. The posterior simulation via the Markov chain Monte Carlo approach is used to produce estimates of posterior properties. Its applicability is illustrated with two real data sets. We compute the predictive distribution and the marginal likelihood of various models to compare the performance of them. The model comparison results show that the model based on the beta-mixture performs better than other models.

A Study on the Water Quality of Domestic Mineral Water (Saeng Su) (국내 보존음료수(생수)의 성분에 관한 연구)

  • 류의형;이중근;김성조
    • Journal of Environmental Health Sciences
    • /
    • v.16 no.2
    • /
    • pp.41-45
    • /
    • 1990
  • This study was performed to analyze for the mineral water (Saeng Su) from 12 pure beverage Co. products, which was obtained during March to May in 1988. The results were as follows: 1. The analytical results of contaminant materials in all the samples were suitable for drinking water standard. The mean value of NH$_{3}$-N, NO$_{3}$-N, Cl-and KMnO$_{4}$ consumption were ND, 49mg/l, 1.08mg/l and 8.14mg/l, respectively. 2. Total bacterial counts were 3/cc in average and Coliforms was negative in all samples. 3. The analytical results of Heavy metals were not detected or detected in a small amount, and the contents were different from each company. The CN, Hg, P were not detected in all the samples and the mean value of Cu, Fe, Mn were 0.0087mg/l, 0.0303mg/l, 0.018mg/l, respectively and it's contents were low. 4. The mean value of Pb, Zn, Cr$^{+6}$, As and Cd were 0.016mg/l, 0.015mg/l, 0.0025mg/l. 0.0059mg/l and 0.0011mg/l respectively.

  • PDF

A Technique of Parameter Identification via Mean Value and Variance and Its Application to Course Changes of a Ship

  • Hane, Fuyuki;Masuzawa, Isao
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1999.10a
    • /
    • pp.153-156
    • /
    • 1999
  • The technique is reported of identifying parameters in off-line process. The technique demands that closed-loop system consists of a reference and two-degree-of-freedom controllers (TDFC) in real process. A model process is the same as the real process except their parameters. Deviations are differences between the reference and the output of the plant or the model. The technique is based on minimizing identification error between the two deviations. The parameter differences between the plant and the model are characterized of mean value and of variance which are derived from the identification error. Consequently, the algorithm which identifies the unknown plant parameters is shown by minimizing the mean value and the variance, respectively, within double convergence loops. The technique is applied to course change of a ship. The plant deviation at the first trial is shown to occur in replacing the nominal parameters by the default parameters. The plant deviation at the second trial is shown to not occur in replacing the nominal parameters by the identified parameters. Hence, the identification technique is confirmed to be feasible in the real field.

  • PDF

Measurement of Joint Aperture Using 3-D Laser Profilometer (3차원 레이저 측정기를 이용한 절리 간극의 측정)

  • 이희석;이연규;이희근
    • Economic and Environmental Geology
    • /
    • v.33 no.4
    • /
    • pp.309-320
    • /
    • 2000
  • Aperture is an important parameter for determining the hydraulic characteristics of fractured media. In this study the topography of artificial rock joint surface was measured using 3D laser profilometer to analyze the aperture distribution. The initial aperture distribution was determined when the contact area became one percent of total joint surface. The initial aperture distribution of granite joint, with the mean value of 0.78 mm and the standard deviation of 0.34 mm was much different from that of the marble joint, with the mean value of 0.57 mm and the standard deviation of 0.26 mm. Apertures of both granite and marble showed normal distributions. Aperture distribution with the contact area of 25% was also analyzed. Mean value was decreased to one third compared to the initial aperture, but the standard deviation was decreased slightly. To determine the spatial correlation of the aperture distribution variogram analysis was carried out on the initial aperture data. Most experimental variograms were fitted well with exponential model. It is expected that the measured aperture characteristics can be used for stochastic analysis of fluid flow through rock joints.

  • PDF

Lipid Content and Fatty Acid Composition of Commercial Fatty Processed Food(I) -Chocolate- (시판 지방성 가공식품의 지질함량과 지방산조성(1)-쵸코렛을 중심으로-)

  • 김정헌;박건용;김복순;오수경;한상운;박성배
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.23 no.2
    • /
    • pp.303-307
    • /
    • 1994
  • This study was carried out to investigate lipid content, melting point, refractive index and fatty acid composition of commercial chocolate and imitation chocolate. Fifty-eight samples for test were 45 of domestics and 13 of foreign in Seoul. The results were as follows ; Mean value of lipid content was 35.1% in chocolate and 31.9% in imitation chocolate, and foreigns were lower than domestics. In melting point of lipid, chocolates and imitation chocolate were 26.4$^{\circ}C$ and 27.4$^{\circ}C$ as mean value, respectively. Mean value of refractive index of lipid was 1.4560, imitation chocolate of domestic were lower than another. The fatty acid compositions were chiefly consisted of {{{{C_18:1 , C_18 , C_16, C_16:1 and C_18:2. }} The ratio of SFA : MUFA : PUFA in chocolate and limitation chocolate were 8.2 :6.9 :1.0 and 3.1 : 4.3: 1.0 , respectively.

  • PDF

A Study on the Efficiency of a Two Stage Shrinkage Testimator for the Mean of an Exponential Distribution

  • Myung-Sang Moon
    • Communications for Statistical Applications and Methods
    • /
    • v.5 no.1
    • /
    • pp.231-238
    • /
    • 1998
  • A two stage shrinkage testimator for the mean of an exponential distribution is considered with the assumption that an initial estimate of the mean is available. Mean squared error(MSE) of testimator and its relative efficiency (to usual single sample mean) are briefly reviewed. It is shown that relative efficiency depends only on the ratio of true mean value and its initial estimate.

  • PDF

Transport Velocity of Perilla Grain on Oscillating Sieve in Elliptical Motion

  • Pang, Yeoun Gyu;Kim, Sang Hun
    • Journal of Biosystems Engineering
    • /
    • v.43 no.3
    • /
    • pp.194-201
    • /
    • 2018
  • Purpose: The objective of this study was to propose a formula for the theoretical grain mean transport velocities of an elliptically moving oscillator by modifying the grain mean transport velocity formula applied to linear motion and to compare the calculated values with the experimental values of grain mean transport velocity. Methods: The values of the throwing index ($K_v$) and the maximum horizontal velocities for various positions on the elliptical oscillator were obtained using kinematic analysis. To obtain the actual grain transport velocity, the mean transport velocities of perilla grains at six positions on the sieve surface were measured using a high-speed camera and compared with the theoretical values. The cam with an eccentric bearing on the oscillator was designed to be eccentric by 1.6 cm so that the lengths of the major axis of the elliptical motion were 3.2-3.6 cm. The material used in the experiments was perilla grain. Results: The experimental result was consistent with the theoretical value calculated using the proposed formula ($R^2$ is 0.80). It is considered that the angle difference between the maximum accelerations in the directions vertical and horizontal to the sieve has as much influence on the grain mean transport velocity as the value of Kv itself. Conclusions: It was possible to theoretically obtain the grain mean transport velocities through a screening device in elliptical motion by modifying the formula of the grain mean transport velocities used in linear motion.

A Cepstral Analysis of Breathy Voice with Vocal Fold Paralysis (성대마비로 인한 기식 음성에 대한 Cepstral 분석)

  • Kang, Young-Ae;Seong, Cheol-Jae
    • Phonetics and Speech Sciences
    • /
    • v.4 no.2
    • /
    • pp.89-94
    • /
    • 2012
  • The aim of this study is to investigate the usefulness of the parameter CPP (cepstral peak prominence) and LTAS (long term average spectrum) band energy for an analysis of breathy voice with vocal fold paralysis. Thirty-four female subjects who have vocal paralysis after thyroidectomy participated in this study. According to the perceptual judgements by three speech pathologists and one phonetic scholar, subjects were divided into two groups: breathy voice group (n = 21) and non-breathy voice group (n = 13). Maximum sustained phonation task was measured for acoustic analysis. CPP-related (i.e. mean F0, mean CPP, and mean CPPs) and LTAS-related (i.e. minimum, maximum, and mean) parameters were used. Independent samples t-test was conducted. Regarding CPP, there are significant differences in mean CPP and mean CPPs between groups. The values of mean CPP and CPPs in the non-breathy voice group are higher than those in the breathy voice group. The CPP could be regarded as the useful parameter for breathy voice analysis in the clinic. When it comes to LTAS, energy from 0 to 2 kHz are significantly different between groups. The minimum value of non-breathy group is lower than that of breathy group, whereas the maximum value of non-breathy group is higher. The frequency band below 2 kHz seems to be related to breathy voice.

Adaptive Shot Change Detection using Mean of Feature Value on Variable Reference Blocks and Implementation on PMP

  • Kim, Jong-Nam;Kim, Won-Hee
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2009.01a
    • /
    • pp.229-232
    • /
    • 2009
  • Shot change detection is an important technique for effective management of video data, so detection scheme requires adaptive detection techniques to be used actually in various video. In this paper, we propose an adaptive shot change detection algorithm using the mean of feature value on variable reference blocks. Our algorithm determines shot change detection by defining adaptive threshold values with the feature value extracted from video frames and comparing the feature value and the threshold value. We obtained better detection ratio than the conventional methods maximally by 15% in the experiment with the same test sequence. We also had good detection ratio for other several methods of feature extraction and could see real-time operation of shot change detection in the hardware platform with low performance was possible by implementing it in TVUS model of HOMECAST Company. Thus, our algorithm in the paper can be useful in PMP or other portable players.

  • PDF