• Title/Summary/Keyword: maximum strength

Search Result 3,749, Processing Time 0.031 seconds

Comparison of Muscle Activity During a Push-up on a Suspension Sling and a Fixed Support (슬링(sling)과 고정된 지지면에서의 팔굽혀펴기 동작 시 근 활성도 비교)

  • Oh, Jae-Seop;Park, Jun-Sang;Kim, Suhn-Yeop;Kwon, Oh-Yun
    • Physical Therapy Korea
    • /
    • v.10 no.3
    • /
    • pp.29-40
    • /
    • 2003
  • The purpose of this study was to compare the muscle activity during a push-up on a suspension sling and a fixed support at the same level. Tests were performed on 15 male subjects. Electromyography using a surface EMG recorded the activity of the triceps, pectoralis major, and internal and external oblique muscles during each push-up. EMG activity was recorded at 0, 45, and 90 degrees of elbow flexion in the push-up position on a suspension sling or a fixed support at the same height above the floor (30 cm). The testing order was selected randomly. The subjects were asked to maintain the push-up position with straight knees, hips, and trunk for 5 seconds at each elbow angle. The mean root mean square (RMS) of EMG activity was calculated. EMG activity was normalized using the maximum voluntary isometric contractιn elicited using a manual muscle testing technique. Two-factor repeated measures analysis of variance (ANOVA) was used to compare the average RMS value of EMG activity for each condition. The EMG activity for the pectoralis major, and internal and external oblique muscles during a push-up on a sling was significantly higher than on a fixed support at all angles of elbow flexion (p<.01). There were significant differences in the EMG activity of the pectoralis major and triceps brachii muscles at difference angles of elbow flexion (p<.05). The pectoralis major muscle had the highest EMG activity at 90 degrees of elbow flexion on both the sling and fixed support. The triceps brachii muscle had the highest EMG activity at 45 degrees of elbow flexion on both the sling and fixed support. The internal and external oblique muscles had the highest EMG activity at 0 degrees of elbow flexion, although the difference with angle of flexion was not significant. These results suggest that to improve proximal and trunk stability and muscle strength, push-ups are more useful when performed on a suspension sling than On a fixed support.

  • PDF

A Study on Structural Performance Evaluation of RC Beams Strengthened with CFRP Plate (탄소섬유판으로 보강된 철근콘크리트 보의 보강성능에 관한 연구)

  • Kim Joong-Koo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.5 no.6 s.22
    • /
    • pp.212-217
    • /
    • 2004
  • Carbon fiber reinforced plastic(CFRP) plate Is one of the alterative materials for soengthening of reinforced and prestressed connote members due to excellent strength and light weight In this paper, the behavior of beams strengthened with CFRP plate and CFS(Carbon fiber sheet) is observed and analyzed from the test results. Especially specimens with thick plate is tested when large moment and large shear lone appear in same position. The main failure mode is a peeling-off of the CFRP plate near the loading points due to flexural-shear crack, Because of this failure mode, failure load is not linearly proportional to the thickness of CFRP plates. When beam is wrapped with CFS around oかy loading point it does not influence on the failure loads. Depending on the loading pattern, it is necessary to consider different design criteria for reinforced concrete members with external reinforcement. When line moment and large shear force appear in same location, maximum thickness may limit to 0.6mm and ratio between moment of strengthened beam and moment of unstrengthened beam is proposed 1.5-2.0. In order to use the plate of thicker than 6mm, CFS may be extended to the location which moment of strengthened beam is 1.5 times than moment of unstrengthened beam.

Properties and Prediction Model for Ultra High Performance Fiber Reinforced Concrete (UHPFRC): (II) Evaluation of Restrained Shrinkage Characteristics and Prediction of Degree of Restraint (초고성능 섬유보강 콘크리트(UHPFRC)의 재료 특성 및 예측모델: (II) 구속 수축 특성 평가 및 구속도 예측)

  • Yoo, Doo-Yeol;Park, Jung-Jun;Kim, Sung-Wook;Yoon, Young-Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.5A
    • /
    • pp.317-325
    • /
    • 2012
  • In this study, to evaluate the shrinkage behavior of ultra high performance fiber reinforced concrete (UHPFRC) under restrained condition, restrained shrinkage test was performed according to ring-test mostly used at home and abroad. Ring-test was performed with the various thicknesses and radii of inner steel ring to give different degree of restraint. Free shrinkage and tensile tests were carried out simultaneously to estimate the degree of restraint, stress relaxation, and shrinkage cracking potential. Test results indicated that the average steel strain and residual tensile stress were reduced as the thicker inner steel ring was used, whereas degree of restraint was increased. The steel strain, residual tensile stress and degree of restraint were hardly affected by the size of radius of inner ring. In the case of all ring specimens, shrinkage crack did not occur because the residual tensile stress was lower than the tensile strength. About 39~65% of the elastic shrinkage stress was relaxed by the sustained interface pressure, and the maximum relaxed stress was increased as the thicker inner ring was applied. Finally, the degree of restraint with age was predicted by performing non-linear regression analysis, and it was in good agreement with the test results.

Flexural Design of Double Composite Box Girder over Interior Pier by LRFD Method (LRFD법에 의한 이중합성 박스거더 최대부모멘트 단면 휨 설계)

  • Cho, Eun Young;Shin, Dong Ku
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.6
    • /
    • pp.737-749
    • /
    • 2007
  • Flexural design of double composite box girder over the interior pier for three-span continuous bridge was performed by the LRFD method. The maximum span length of the continuous bridge ranged from 80m to 120m and the relative ratio of the span length was assumed to be 1:1.25:1. The girder section was designed for the strength limit state and service limit state with additional design check for constructibility. Before the bottom concrete and compression flange showed a complete composite action, the buckling of lower compression flange was checked. The flexural stiffness and flexural resistance characteristics for the section and for the constituent members such as tension flange, compression flange, and web were analyzed for different thicknesses of the bottom concrete on top of the compression flange. The effect of the distribution ratio of steel between the top and bottom flanges was investigated by analyzing ductility behavior and stress distribution through the girder's depth for several different relative area ratios of steel between the top and bottom flanges. It was found that a total amount of 15% of steel can be saved by applying the double composite system compared with that of the conventional composite system.

Blend Films of Poly(acrylic acid-co-maleic acid) with Poly(vinyl alcohol) (I) : Thermo-mechanical Properties and Gas Permeability (폴리(비닐 알코올)과 폴리(아크릴산-말레산) 공중합체의 블렌드 필름 (I) : 열적-기계적 성질 및 가스 투과도)

  • Ham Shin-Kyun;Jung Min-Hye;Chang Jin-Hae
    • Polymer(Korea)
    • /
    • v.30 no.4
    • /
    • pp.298-304
    • /
    • 2006
  • Blends of poly (acrylic acid-co-maleic acid)(PAM) with poly (vinyl alcohol)(PVA) were obtained by solution blending. The blends were solvent-on to a film to examine thermo-mechanical properties and gas permeability. The transition temperatures $(T_g\;and\;T_m)$ of the blends remained constant regardless of PAM contents. However, the values of enthalpy changes corresponding to melting transition $({\Delta}H_m)$ and initial degradation temperature $({T_D}^i)$ were decreased with increasing PAM content. The values of ultimate strength and initial modulus gave the maximum value at the 12 wt% PAM then decreased with further increase of PAM content up to 15 wt%. To measure the gas permeability of the PVA/PAM blend films, the PVA blend solutions were coated onto both biaxially oriented propylene (BOPP) and poly (ethylene terephthalate)(PET) films. The oxygen transmission rate $(O_2\;TR)$ permeability values mono- tonically decreased with increasing PAM content. However, moisture vapor transmission rate was not affected by PAM content.

Setting up Relationship between Pull-out Resistance of Helical Anchor and Rotational Penetration Torque for Methodology Development (헬리컬 앵커개발 및 적용을 위한 앵커의 회전 관입 토크와 인발저항력과의 상관관계 정립)

  • Kim, Nak-Kyeong;Kim, Young-Uk;Moon, Jun-Ho;Xin, Zhen-Hua;Gu, Kyo-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.661-667
    • /
    • 2016
  • This study evaluated the potential of methodology development of the helical type anchor for soft ground applications. The rotational penetration of the helix structure might make construction-steps easy without the soil spitting and reusable rods could reduce the material cost. Removal of the anchors would be simple as a construction, which can be named the removal anchor. The anchoring resistance after construction is strongly related to the number of helixes resulting in a concise design process. The investigation involved a chamber test with soft soils. In the test, a specially designed and fabricated helical anchor and torque-driver were used to obtain the maximum pull-out resistance of the anchor after rotational penetration. As a result of the tests, The rotational torque and pull-out resistance have a proportional relationship with the strength of the prepared soils. Within the range of the study, the torque of the anchor penetrating increased with increasing pull-out resistance.

Adsorption Characteristics of Aqueous Phosphate Using Biochar Derived from Oak Tree (참나무 바이오차의 인산염 인(PO4-P) 흡착특성)

  • Choi, Yong-Su;Hong, Seung-Gil;Kim, Sung-Chul;Shin, Joung-Du
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.23 no.3
    • /
    • pp.60-67
    • /
    • 2015
  • Objective of this study was to investigate adsorption characteristics of $PO_4-P$ to biochar produced from oak tree in respective to reduce eutrophication from runoff water in the cropland. For adsorption experiment, input amount of biochar was varied from 4 to 20 g/L with 30 mg/L $PO_4-P$ solution. Adsorption amounts and removal rates of $PO_4-P$ was increased at 3 times in 4~14 g/L, and increased at 28.6% in 4~16 g/L, respectively. The maximum adsorption amount ($q_m$) and binding strength constant(b) were calculated as 0.10 mg/g and 0.06 L/mg, respectively. The sorption of $PO_4-P$ to biochar was fitted well by Langmuir model because it was observed that dimensionless constant($R_L$) was 0.37. It was indicated that biochar is favorably adsorbed $PO_4-P$ because this value lie within 0 < $R_L$ < 1. Therefore, biochar produced from oak tree could be used as adsorbent for reduce eutrophication from runoff water in the cropland.

Electrorheological Behaviors and Interfacial Polarization of Semi-conductive Polymer-based Suspensions (반도성 고분자 현탁액의 전기유변학적 거동과 계면편극화)

  • B.D Chin;Lee, Y.S.;Lee, H.J.;S.M. Yang;Park, O.O.
    • The Korean Journal of Rheology
    • /
    • v.10 no.4
    • /
    • pp.195-201
    • /
    • 1998
  • We have studied the rheological and electrical properties of two types of electrorheological (ER) fluids based on semi-conductive polymers (poly(p-phenylene) and polyaniline). These semi-conductive polymer-based suspensions showed a dramatic increase in viscosity on the application of the static electric field due to the large value of conductivity ratio between particle and medium. The dynamic yield stresses of these ER suspensions exhibited a quadratic dependence on electric field strength at low electric fields and a linear one for high fields. They showed a maximum and then decreased with increasing bulk conductivity of particles. These yield stress behaviors under the static electric field were found to be closely related to the dielectric properties, which is in accord with Maxwell-Wagner interfacial polarization induced by the conductivity effects. In order to achieve better understanding of interfacial polarization effect on ER response and to improve the stability of ER suspension, different kinds of surfactants were employed for controlling the ER activity as well as for enhancing the colloidal stability of suspensions.

  • PDF

Damage Analysis of Nearby Structures with the Consideration of Tunnel Construction Conditions in Sandy and Clayey Ground (모래 및 점토지반에서 터널시공조건을 고려한 인접구조물의 손상도 분석)

  • Son, Moorak;Yun, Jongcheol
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.1C
    • /
    • pp.53-63
    • /
    • 2011
  • This paper investigates the effects of tunnelling-induced ground movements on nearby structures, considering soil-structure interactions of different ground (loose sand, dense sand, soft clay, stiff clay) and construction conditions (ground loss). The response of four-story block structures, which are subjected to tunnelling-induced ground movements, has been investigated in different ground and construction conditions (ground loss) using numerical analysis. The structures for numerical analysis has been modelled using Discrete Element Method (DEM) to have real cracks when the shear and tensile stress exceed the maximum shear and tensile strength. The response of four-story block structures has been investigated with a ground movement magnitude and compared in terms of ground and construction conditions (ground loss) considering the magnitude of deformations and cracks in structures. In addition, the damage levels, which are possibly induced in structures, has been provided in terms of ground and construction conditions (ground loss) using the state of strain damage estimation criterion (Son and Cording, 2005). The results of this study will provide a background for better understandings for controlling and minimizing building damage on nearby structures due to tunnelling-induced ground movements.

Analysis of Accuracy of Apparent Activity According to Calibration Method for High Dose Rate Brachytherapy Source (측정용 전리함에 따른 고 선량율 근접치료용 방사성 선원의 겉보기 활성도의 정확도 비교 분석)

  • Huh, Hyun-Do;Choi, Jin-Ho;Choi, Sang-Hyoun;Kim, Seong-Hoon;Kim, Woo-Chul;Kim, Hun-Jeong;Lee, Re-Na;Kim, Kum-Bae;Hong, Seong-Eon;Shin, Dong-Oh
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.305-312
    • /
    • 2008
  • The aim of this study is to introduce the accuracy of Ir-192 source's apparent activity using the well-type chamber and the Farmer-type ionization chamber in the high dose rate brachytherapy. We measured the apparent activity of Ir-192 that each medical center in the country has and the apparent activity of calibration certificate provided by manufacturer is compared with that by our experimental measurement. The number of sources used for the activity comparison was 5. The accuracy of the measured activity was in the range of -2.8% to -1.0% and -2.1% to 0.2% for the Farmer-type chamber system (Jig) and for the well-type, respectively. The maximum difference was within 1.0% for comparison with two calibration's tool. Our results demonstrate that well-type chamber as wall as Farmer-type chamber is a appropriate system as the routine source calibration procedures in HDR brachytherapy. Whenever a new source is installed to use in clinics, by periods, a source calibration should be carried out.

  • PDF