• Title/Summary/Keyword: maximum sensitivity

Search Result 941, Processing Time 0.035 seconds

FBG Sensor Probes with Silver Epoxy for Tracing the Maximum Strain of Structures

  • Im, Jooeun;Kim, Mihyun;Choi, Ki-Sun;Hwang, Tae-Kyung;Kwon, Il-Bum
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.5
    • /
    • pp.459-464
    • /
    • 2013
  • Structures can be evaluated their health status by allowable loading criteria. These criteria can be determined by the maximum strain. Therefore, in order to detect this maximum strain of structures, fiber optic Bragg grating(FBG) sensor probes are newly designed and fabricated to perform the memorizing detection even if the sensor system is on-and-off. The probe is constructed with an FBG optical fiber embedded in silver epoxy. When the load is applied and removed on the structure, the residual strain remains in the silver epoxy to memorize the maximum strain effect. In this study, a commercial Al-foil bonded FBG sensor probe was tested to investigate the detection feasibility at first. FBG sensor probes with silver epoxy were fabricated as three different sizes. The detection feasibility of maximum strain was studied by doing the tensile tests of CFRP specimens bonded with these FBG sensor probes. It was investigated the sensitivity coefficient defined as the maximum strain divided by the residual strain. The highest sensitivity was 0.078 of the thin probe having the thickness of 2 mm.

A Design of Pressure Sensor for Improving Linearity at Low Pressure Range (저압에서의 선형성을 향상시키기 위한 압력센서의 설계)

  • Lee, Bo-Na;Lee, Moon-Key
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.2
    • /
    • pp.1-8
    • /
    • 1996
  • In this paper, We have designed silicon pressure sensor with center-bossed diaphragm which improving sensitivity and linearity by reducing diaphragm deflection. Designed center-bossed pressure sensor showed maximum deflection of $0.125{\mu}m$, maximum stress of $2.24{\times}10^7 Pa$ and sensitivity of 27.67 mV/V.psii. As a result, diaphragm deflection was reduced to 1/160 that of diaphragm thickness and 1/35 that of square diaphragm. Also, sensitivity was increased 19 times compared to square diaphragm.

  • PDF

Airbag Accelerometers Using Silicon Epitaxial Layers (실리콘 에피층을 이용한 자동차 에어백용 가속도계)

  • 고종수;김규현;이창렬;조영호;이귀로;곽병만
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.5
    • /
    • pp.9-15
    • /
    • 1996
  • A silicon microaccelerometer is designed and fabricated using silicon epitaxial layers for automotive electronic airbag applications. A cantilever structure is chosen for high sensitivity and piezoresistive detection method is adopted for circuit simplicity and low cost. An optimum design is used to find optimum microstructure sizes for maximum sensitivity subject to performance requirements and design constraints on natural frequency, damping ratio, maximum allowable stress and microfabrication limitations. The microaccelerometer is fabricated by micromachining processing steps, composed of material-selective and orientation-dependent chemical etching techniques. Fabricated prototype shows a sensitivity of 88.6$\mu\textrm{V}$/g within a resonant frequency of 1.75KHz. Estimated performance of the microaccelerometer is compared with measured one. Discrepancy between the theoretical values and the experimental values is discussed together with possible sources of the errors.

  • PDF

Numerical Investigation on Surface Plasmon Resonance Sensor Design with High Sensitivity Using Single and Bimetallic Film Structures (고감도 단금속 및 쌍금속 표면 플라즈몬 공명 센서 설계를 위한 수치해석 연구)

  • Gwon, Hyuk-Rok;Lee, Seong-Hyuk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.4
    • /
    • pp.795-800
    • /
    • 2009
  • Surface plasmon resonance (SPR) has been widely used for biological and chemical sensing applications. The present study investigates numerically the optical characteristics for the single Au film and bimetallic Ag/Au film SPR configurations by using the multiple beam interference matrix (MBIM) method. We use the prism coupling method, especially Kretschmann configuration for excitation of surface plasmon wave (SPW). The estimated results of reflectance, phase shift and magnetic field intensity enhancement factor are provided for finding out the optimum configuration with high sensitivity for SPR measurement. As a result, the optimum thicknesses are found to be 52 nm for a single Au film and 5 nm to 36 nm for bimetallic Ag-Au film. From the comparison of full width half maximum (FWHM) values for reflectance, phase shift, and enhancement of magnetic field intensity, it is concluded that the highest sensitivity can be obtained when using the phase shift for SPR sensor.

High-sensitivity NIR Sensing with Stacked Photodiode Architecture

  • Hyunjoon Sung;Yunkyung Kim
    • Current Optics and Photonics
    • /
    • v.7 no.2
    • /
    • pp.200-206
    • /
    • 2023
  • Near-infrared (NIR) sensing technology using CMOS image sensors is used in many applications, including automobiles, biological inspection, surveillance, and mobile devices. An intuitive way to improve NIR sensitivity is to thicken the light absorption layer (silicon). However, thickened silicon lacks NIR sensitivity and has other disadvantages, such as diminished optical performance (e.g. crosstalk) and difficulty in processing. In this paper, a pixel structure for NIR sensing using a stacked CMOS image sensor is introduced. There are two photodetection layers, a conventional layer and a bottom photodiode, in the stacked CMOS image sensor. The bottom photodiode is used as the NIR absorption layer. Therefore, the suggested pixel structure does not change the thickness of the conventional photodiode. To verify the suggested pixel structure, sensitivity was simulated using an optical simulator. As a result, the sensitivity was improved by a maximum of 130% and 160% at wavelengths of 850 nm and 940 nm, respectively, with a pixel size of 1.2 ㎛. Therefore, the proposed pixel structure is useful for NIR sensing without thickening the silicon.

Optimization of Operation Frequency of Orthogonal Fluxgate Sensor Fabricated with Co Based Amorphous Wire

  • Kim, Young-Hak;Kim, Yongmin;Yang, Chang-Seob;Shin, Kwang-Ho
    • Journal of Magnetics
    • /
    • v.18 no.2
    • /
    • pp.159-162
    • /
    • 2013
  • We present how to optimize the operation condition including frequency of the orthogonal fluxgate sensor in this paper. The orthogonal fluxgate sensor was fabricated with a Co-based amorphous wire with 10 mm long and 100 ${\mu}m$ in the diameter and a 270-turn pickup coil wound on the amorphous wire. In order to investigate the frequency dependence of the sensitivity, output spectra of the sensor which was connected by using a coaxial cable with various lengths of 0.5-5 m were measured with a RF lock-in amplifier. The maximum sensitivities were obtained at different frequencies according to coaxial cable lengths. It was found that the optimal operation frequencies, at which maximum sensitivities were appeared, were almost identical to the frequencies of impedance resonance. The maximum sensitivity and optimal operation frequency were 1.1 V/Oe (${\approx}$ 11000 V/T) and 1.25 MHz respectively.

Regional Heterogeneity of Morphological Changes in Cultured Rat Astrocytes

  • Won, Chung-Kil;Oh, Young-S.
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.5 no.6
    • /
    • pp.467-477
    • /
    • 2001
  • We examined astrocyte regional heterogeneity in their morphological changes in response to various stimuli. Astrocytes were cultured from six different neonatal rat brain regions including cerebral cortex, hippocampus, cerebellum, mid brain, brain stem and hypothalamus. Astrocyte stellation was induced by serum deprivation and the maximum stellation in different regional astrocytes was achieved after 2 h. After 24 h, in all astrocyte cultures, the level of stellation returned to their original level. Cerebellar or hypothalamic astrocytes were the most or the least sensitive, respectively, to serum deprivation. The order of maximum sensitivity to serum deprivation among different regional astrocytes was: cerebellum>mid $brain{\ge}hippocampus,\;brain\;stem{\ge}cerebral$ cortex>hypothalamus. Isoproterenol-induced astrocyte stellation was also examined in different regional astrocytes, and similar order of maximum sensitivity as in serum deprivation was observed. Next a possible developmental effect on astrocyte morphological changes was examined in cerebral cortex and cerebellum astrocytes cultured from postnatal day 1 (P1), P4 and P7 rat brains. A much higher sensitivity of cerebellum astrocytes to serum deprivation as well as isoproterenol treatment was consistently observed in P1, P4 and P7-derived astrocytes compared to cerebral cortex astrocytes. The present study demonstrates different regional astrocytes maintain different levels of morphological plasticity in vitro.

  • PDF

Diagnostic performance of enzyme-linked immnosorbent assays for diagnosing paratuberculosis in cattle: a meta-analysis

  • Pak, Son-Il
    • Korean Journal of Veterinary Research
    • /
    • v.44 no.4
    • /
    • pp.669-676
    • /
    • 2004
  • To evaluate the diagnostic accuracy of two commercial ELISA tests (Allied- and CSL-ELISA) for the diagnosis of Mycobacterium paratuberculosis in cattle, Meta-analysis using English language papers published during 1990-2001 was performed. Diagnostic odds ratios (DOR) were analyzed using regression analysis together with summary receiver operating characteristic (ROC) curves. The difference in diagnostic performance between the two ELISA systems was evaluated by using linear regression. Publication bias was assessed by funnel plot and linear regression. The pooled sensitivity and specificity were 44% (95% CI, 38 to 51) and 98% (95% CI, 96 to 99) for the random-effect model. The DOR between studies was heterogeneous. The area under the fitted ROC curve (AUC) was 0.72 for the unweighted and 0.77 for the weighted model. Maximum joint sensitivity and specificity for the unweighted and weighted model from their summary ROC curve were 70% and 75%, respectively. Based on the fitted model, at a specificity of 95%, sensitivity was estimated to be 52% for the unweighted and 57% for the weighted model. From the final multivariable model study characteristic, the country was the only significant variable with an explained component variance of 13.3%. There were no significant differences in discriminatory power, sensitivity, and specificity between the two ELISA tests. The overall diagnostic accuracy of two commercial ELISA tests was moderate, as judged by the AUC, maximum joint sensitivity and specificity, and estimates from the fitted model and clinical usefulness of the tests for screening program is limited because of low sensitivity and heterogeneous of DOR. It is, therefore, recommended to use ELISA tests as a parallel testing with other diagnostic tests together to increase test sensitivity in the screening program.

Development of a Simplified Statistical Methodology for Nuclear Fuel Rod Internal Pressure Calculation

  • Kim, Kyu-Tae;Kim, Oh-Hwan
    • Nuclear Engineering and Technology
    • /
    • v.31 no.3
    • /
    • pp.257-266
    • /
    • 1999
  • A simplified statistical methodology is developed in order to both reduce over-conservatism of deterministic methodologies employed for PWR fuel rod internal pressure (RIP) calculation and simplify the complicated calculation procedure of the widely used statistical methodology which employs the response surface method and Monte Carlo simulation. The simplified statistical methodology employs the system moment method with a deterministic approach in determining the maximum variance of RIP The maximum RIP variance is determined with the square sum of each maximum value of a mean RIP value times a RIP sensitivity factor for all input variables considered. This approach makes this simplified statistical methodology much more efficient in the routine reload core design analysis since it eliminates the numerous calculations required for the power history-dependent RIP variance determination. This simplified statistical methodology is shown to be more conservative in generating RIP distribution than the widely used statistical methodology. Comparison of the significances of each input variable to RIP indicates that fission gas release model is the most significant input variable.

  • PDF

Simultaneous Spectral Resolution and Sensitivity Enhancement in MR spectrum: Maximum Likelihood Deconvolution Reconstruction

  • Jeong, Gwang-Woo;Jeong, Jenny Eunice;Kang, Heoung-Keun
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.15 no.2
    • /
    • pp.157-174
    • /
    • 2011
  • Although the use of apodization functions in connection with postprocessing of a 2D NMR spectrum proves improved spectral quality, there is usually a trade-off between resolution enhancement and noise suppression due to a classical "uncertainty principle." In this study, therefore, a mathematical deconvolution technique called "Maximum Likelihood Deconvolution (MLD)" was adopted to achieve the spectral resolution and sensitivity enhancement simultaneously. The MLD technique greatly facilitates visualization and restoration of the genuine spectral information from complex 2D NMR spectra that would be problematic with the conventional apodization/FT processing. In particular, application of the MLD to the 2D-NOE spectrum would be very useful to derive the important proton connectivities, which are essential to achieve elucidating the 3D molecular structure.