• Title/Summary/Keyword: maximum power tracking

Search Result 569, Processing Time 0.037 seconds

A Study on the Installation Angle of the Marine Solar Power Generation System (해상용 태양광 발전 시스템의 설치 각도에 관한 연구)

  • Oh, Jin-Seok;Jang, Jae-Hee
    • Journal of Navigation and Port Research
    • /
    • v.42 no.3
    • /
    • pp.167-176
    • /
    • 2018
  • A solar power generation system on single point moored offshore plant has independent power system In order to satisfy the maritime environment and account for the number of sunless days, it is important to supply stable electric power to the systems. For these reasons, solar panels are installed in multiple directions. However, a partial shading effect occurs because the amount of light incident on each panel is different. The generated power by the solar generation system installed on land is affected by the latitude, then it is installed at an angle of 30 to $45^{\circ}$. in the case of Korea. In the case of a solar power generation system installed in a mooring type of marine plant, there is a possibility that the maximum power point is outside of the controllable range due to the partial shading effect. Therefore, a power generation loss occurs. By reducing the light amount difference between both panels, the maximum power point can exist in a range where the MPPT algorithm can track the power. The purpose is so the power generation efficiency can be further increased. In this paper, simulation results show that the highest power generation efficiency is obtained at an installation angle of $20^{\circ}$.

High-Frequency DC Link Inverter for Grid-Connected Photovoltaic System (고주파링크방식을 이용한 PV용 PCS의 고찰)

  • Jung, Young-Seok;Yu, Gwon-Jong;Jung, Myoung-Woong;Choi, Jae-Ho;Choi, Ju-Yeop
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1313-1315
    • /
    • 2002
  • This paper proposes an inverter for the grid-connected photovoltaic system based on the transformer-less inverter. This system consists of a high frequency inverter bridge, high frequency transformer, diode bridge rectifiers, a DC filter, a low frequency inverter bridge, and an AD filter. The high frequency inverter bridge switching at 20kHz is used to generate bipolar PWM pulse, which is subsequently rectified by diode bridge rectifiers to result in a full-wave rectified sine wave. Finally, it is unfolded by a low frequency inverter bridge to result in a 60Hz sine wave power output. In this paper, the control algorithm for synchronous current feedback control method and a maximum power point tracking (MPPT) method using DSP are described. And, the simulation and experimental results are shown to verify the validity of the proposed system.

  • PDF

Photovoltaic Maximum Power Point Tracking method without Current Sensor for Module Integrated Converter operating independently (전류 센서없이 독립적으로 동작하는 모듈 통합형 컨버터에서의 최대 전력점 추종 기법)

  • Moon, Sol;Kim, Do-Hyun;Kim, Chan-In;Thang, Tran-Viet;Park, Joung-Hu
    • Proceedings of the KIPE Conference
    • /
    • 2011.11a
    • /
    • pp.61-62
    • /
    • 2011
  • 기존의 직렬 연결된 부스트 컨버터 타입의 태양광 전력 조절기는 MPPT 동작을 하기에 있어서 반드시 하나의 모듈만 동작했어야 하기 때문에 각 모듈이 MPPT 지점에 도달했다는 것을 알리기 위하여 양방향 통신 기술을 필요로 했다. 하지만 제안하는 MPPT 방법은 통신 기능을 사용하지 않음으로서 가격적인 측면에서 합리적이다. 본 논문에서는 제안하는 MPPT 방법의 동작원리를 설명하고 시뮬레이션으로 확인하였다.

  • PDF

Realization of Digital control of Grid_connected Modular Photovoltaic Inverter (계통연계형 모듈형 태양광 인버터의 디지털 제어의 구현)

  • Lee, Seung min;Lee, Woo cheol
    • Proceedings of the KIPE Conference
    • /
    • 2011.11a
    • /
    • pp.287-288
    • /
    • 2011
  • 주택 혹 산업용, 공공건물용으로 상용화 되어 있는 스트링 어레이 중앙 인버터 방식은 고압의 DC 배선으로 인한 안전문제, 고가의 고압 DC 차단기의 설치 및 과전압보호기 등으로 가격이 상승하게 되고 설치 시에도 패널간 균일 성능을 보장해야하고 스트링 상에 놓여 있는 패널 일부가 불량이거나 그림자가 져서 발전이 미비할 경우 전체 시스템 발전이 정지하거나 발전량이 미비해지는 문제가 생기므로 항상 최적의 상태로 운전할 수 없다. 그래서 이러한 태양광 발전 방식의 문제점을 해결하기 위해 각 모듈마다 마이크로 인버터를 장착하여 각각 패널마다 분산적인 MPPT(Maximum Power Point Tracking) 를 수행할 수 있고 DC 배선이 없기 때문에 시스템 설치비용을 획기적으로 절감할 수 있으며 안정성 문제도 중앙 인버터 방식보다 획기적으로 향상된다. 패널 또는 인버터 고장 시 전체 시스템의 차단 없이 교체가 가능 하여 시스템의 설비 이용률을 최대로 할 수 있다. 이러한 패널에 쓰이는 마이크로 인버터를 PSIM으로 구현하여 DLL로 통해 디지털 제어로 구현을 하고 시뮬레이션으로 통해 시스템의 효능을 알아보았다.

  • PDF

FLC Implementation for Maximum Power Point Tracking Control of Wind Turbine System (풍력발전 시스템의 최대전력점 추종 제어를 위한 FLC 구현)

  • Jang, Mi-Geum;Song, Sung-Geun;Oh, Seung-Yeol;Choi, Jung-Sik;Chung, Dong-Hwa
    • Proceedings of the KIPE Conference
    • /
    • 2011.11a
    • /
    • pp.273-274
    • /
    • 2011
  • 최근에는 풍속변화에 대응하여 최대전력을 발생할 수 있는 가변속 풍력발전 시스템에 대한 연구가 활발히 진행 중이며 국내의 지형적 조건에 따른 바람의 영향으로 풍력발전 시스템의 MPPT제어가 반드시 필요하다. 종래의 풍력발전 MPPT 제어는 풍속변화에 대한 응답속도 등에 대한 문제점이 나타난다. 따라서 본 논문에서는 파라미터 변동에 대해 강인성 제어가 가능한 FLC(Fuzzy Logic Control)을 기반으로 한 풍력발전시스템의 MPPT 제어를 제안하고, 시뮬레이션 결과를 통하여 타당성을 입증한다.

  • PDF

The Photovoltaic Power Generation System with SEPIC-Flyback Converter (태양광 발전용 SEPIC-Flyback 컨버터)

  • Jung, Doo-Yong;Jang, Su-Jin;Ji, Yong-Hyuk;Won, Chung-Yuen;Jung, Yong-Chae
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.49-52
    • /
    • 2007
  • In this paper, we proposed a design photovoltaic generation systems with SEPIC-Flyback converter. The SEPIC-Flyback converter is operated to SEPIC converter the state turn-on of the switch and the state turn-off the switch is operated Flyback converter. Therefore application rate of the core increases and voltage stress of switch and transformer decreases with active clamp operation. Also we performed MPPT(Maximum Power Point Tracking) control for efficient working of Photovoltaic Dower generation system.

  • PDF

Design of the Anti-sway Controller for a Boom Type Crane Using the LQ Control (LQ 제어를 이용한 붐형 크레인의 흔들림 제어기 설계)

  • Son, J.K.;Hong, J.P.;Kwon, S.J.
    • Journal of Power System Engineering
    • /
    • v.7 no.4
    • /
    • pp.74-81
    • /
    • 2003
  • An LQ controller design method is proposed for effective anti-sway control of boom type crane in this paper. It is important for high productivity that the sway of a load is controlled as fast as possible when the trolley arrives to the destination with maximum velocity. To prove the effectiveness of the proposed LQ controller. simulations and experiments using the boom type crane as experimental device is carried out. Tracking performance for a step type reference and robustness for the change of working environment such as the change of load weight and parameters produced by a wire rope and disturbance by the wind arc proved by the experiment. It will be examined that boom type crane can be applied to industrial fields through experiment in this paper.

  • PDF

The Study of Maximum Power Point Tracking Controller for the Wind Power Generator (풍력발전기용 최대전력점 추종제어기에 관한 연구)

  • Kang, Ju-Sung;Koh, Kang-Hoon;Han, Ho-Dong;Lee, Hyun-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2006.10d
    • /
    • pp.155-157
    • /
    • 2006
  • 현재 화석연료에만 의존하는 에너지 시장을 변화시키고자 하는 연구가 활발히 이루어지고 있는 가운데 신재생에너지(연료전지, 풍력, 태양광 등)를 복합적으로 활용한 분산전원시스템에 관한 관심이 증가하고 있다. 이 가운데 풍력 발전시스템은 발전효율, 가격측면 등에 있어 많이 연구되고 있다. 그러나 풍력발전시스템의 경우 난류가 되기 쉽고, 풍향이나 풍속이 수십초의 간격으로 변화하기 때문에, 바람의 에너지를 최대한 이용하는 최대전력점추종(MPPT)제어기의 역할이 가장 중요하다. 본 논문에서는 소형풍력발전기를 활용하여 풍속, 풍차 회전속도, 전력 등의 정보를 이용한 기존 방식에 비하여 아주 간단한 제어기법을 구현하고자 한다.

  • PDF

FPGA Implementation of Fuzzy Logic Controller for Maximum Power Point Tracking in Solar Power System (태양전지 최대전력점 추종제어를 위한 퍼지 제어기의 FPGA구현)

  • Kim, Hyung-Jin;Chun, Kyung-Min;Lee, Woo-Hee;Lee, Jun-Ha;Lee, Hoong-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.555-556
    • /
    • 2006
  • 태양전지는 일사량에 따라 그 출력특성이 변화하기 때문에 태양전지로부터 최대출력을 얻기 위해서는 컨버터에 의한 최대 전력점 추종 제어가 필요하다. 본 연구에서는 태양광 발전시스템의 최대전력추종을 위해 퍼지 이론을 도입한 퍼지제어기를 설계하였다. 그리고 퍼지제어기의 디지털 설계를 위해 태양광 발전시스템의 각 부분을 구성하고, 마이크로프로세서와 FPGA의 두 가지 방식으로 제어기를 구현하였다. 또한 구현된 두 가지 방식의 퍼지제어기에 대해 실험을 통하여 비교 분석하였다.

  • PDF

Heart-rate Measurement During Exercise Using PPG Signal (PPG 신호를 이용한 운동 중 맥박수 측정)

  • Lee, Keun-Sang;Baek, Young-Hyun;Park, Young-Chool
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.2
    • /
    • pp.170-175
    • /
    • 2010
  • A method of measuring heart rate using photoplethysmograph(PPG) signal during exercise is proposed. PPG's are composed of strong base tones and their harmonics, and the strong base tones are trackable by the adaptive notch filter (ANF) which adjusts its coefficients to minimize the output power. The proposed heart rate measurement algorithm continuously notches the frequency component with the maximum power in the measured PPG, so that the fundamental frequency corresponding to heart rate is traced. We also presents methods of detecting degeneration and impulsive noise blocks to minimize the coefficient fluctuation. Experiments were conducted using real PPG signals captured during exercise. Results showed that the proposed algorithm is capable of consistently tracking the heart rate embedded in the noisy PPG's.