• Title/Summary/Keyword: maximum moment

Search Result 908, Processing Time 0.024 seconds

A new model based on Lomax distribution

  • Alshingiti, Arwa M.;Kayid, M.;Aldossary, H.
    • International Journal of Reliability and Applications
    • /
    • v.15 no.1
    • /
    • pp.65-76
    • /
    • 2014
  • In this article, a new model based on Lomax distribution is introduced. This new model is both useful and practical in areas such as economic, reliability and life testing. Some statistical properties of this model are presented including moments, hazard rate, reversed hazard rate, mean residual life and mean inactivity time functions, among others. It is also shown that the distributions of the new model are ordered with respect to the strongest likelihood ratio ordering. The method of moment and maximum likelihood estimation are used to estimates the unknown parameters. Simulation is utilized to calculate the unknown shape parameter and to study its properties. Finally, to illustrate the concepts, the appropriateness of the new model for real data sets are included.

  • PDF

Study on the Ultimate Flexural Behavior Analysis of Prestressed Concrete Beam with External Unbonded Tendons (외적 비부착강선을 가진 프리스트레스트 콘크리트 보의 극한휨거동 해석)

  • 오병환;유성원;신정성
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10b
    • /
    • pp.662-667
    • /
    • 1998
  • Recently, the using PSC with external unbonded tendons is increased. However, the behavior of external unbonded tendons is different with that of bonded internal tendon at ultimate state by compatibility condition, the slip with friction at deviator and the change of tendon eccentricity e.t.c., So, the analytical research considered the effect of these inherent characters was performed and the tendency of external unbonded tendons was estimated by numerical examples. By the analytical results, load-deflection relationship and stress increment of external unbonded tendons were similar to those of internal bonded tendon at initial elastic behavior state. Those characters were, however, smaller than those character of internal bonded tendons. For external unbonded tendons, if the 1 deviator which is positioned at maximum moment point and more 2 deviators which are position between maximum moment point and support are existed, the flexural behavior is similar to internal bonded tendons.

  • PDF

Determination of Span Length Ratio in Bridges Constructed using a Free Cantilever Method (FCM 교량의 경간비(SLR) 결정)

  • 곽효경;손제국
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2003.10a
    • /
    • pp.259-266
    • /
    • 2003
  • This paper introduces a relation to determine the span ratio between exterior and interior spans, which is strongly required in the preliminary design stage of bridges constructed by Free Cantilever Method (FCM). A relation for the initial tendon force is derived on the basis of an assumption that no vertical deflection occurs at the far end of a cantilever beam due to the balanced condition between the self-weight and the cantilever tendons. In advance, the span ratio can be determined by using an assumption that the negative maximum moment must be the same with the positive maximum moment along the entire spans to be a rational bridge design. Finally, many rigorous lime-dependent analyses are conducted to establish the validity of the introduced relations. The obtained numerical results show that the rational design of FCM bridges may be achieved when the span length ratio of the exterior span to the interior span ranges about 0.75 to 0.8.

  • PDF

Length-biased Rayleigh distribution: reliability analysis, estimation of the parameter, and applications

  • Kayid, M.;Alshingiti, Arwa M.;Aldossary, H.
    • International Journal of Reliability and Applications
    • /
    • v.14 no.1
    • /
    • pp.27-39
    • /
    • 2013
  • In this article, a new model based on the Rayleigh distribution is introduced. This model is useful and practical in physics, reliability, and life testing. The statistical and reliability properties of this model are presented, including moments, the hazard rate, the reversed hazard rate, and mean residual life functions, among others. In addition, it is shown that the distributions of the new model are ordered regarding the strongest likelihood ratio ordering. Four estimating methods, namely, method of moment, maximum likelihood method, Bayes estimation, and uniformly minimum variance unbiased, are used to estimate the parameters of this model. Simulation is used to calculate the estimates and to study their properties. Finally, the appropriateness of this model for real data sets is shown by using the chi-square goodness of fit test and the Kolmogorov-Smirnov statistic.

  • PDF

Prediction of Lateral Deflection and Maximum Bending Moment of Model Piles Using Artificial Neural Network (인공 신경망을 이용한 모형말뚝의 수평변위와 최대 휨모멘트 예측)

  • 김병탁;김영수;이우진
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.5
    • /
    • pp.169-178
    • /
    • 2000
  • 본 논문에서는 단일 및 군말뚝의 수평변위와 최대 휨모멘트를 예측하기 위하여 인공신경망을 도입하였다. 인공신경망에 의한 결과는 낙동강 모래지반에서 단일 및 군말뚝에 대하여 수행한 일련의 모형실험결과와 비교하였다. 인공신경망 중의 하나인 오류 역전파 신경망(EBIPNN)의 적용성 검증을 위하여 600개의 모형실험결과들을 이용하였다. 그리고 신경망의 구조는 한개의 입력층과 두개의 은닉층 그리고 한개의 출력층으로 구성되었다. 전체 데이터의 25%, 50% 그리고 75% 결과는 각각 신경망의 학습에 이용되었으며 학슴에 이용하지 않은 데이터들은 예측에 이용되었다. 인공신경망 학습결과와 실험결과의 비교에 의하면, 신경망의 최적학습을 위하여 최적학습을 위하여 적합한 은닉층의 뉴런수는 각각 30개로 그리고 학습률은 0.9로 결정되었다. 전체 데이터의 50%이상으로 학습을 수행한 신경망의 모델은 정확한 예측을 하는 것으로 나타났다. 따라서, 인공신경망 모델리 수평하중을 받는 말뚝의 수평변위와 최대 휨모멘트의 예측에 적용될 수 있는 가능성을 보여주었다.

  • PDF

A Numerical Study of Car Seat Recliner (자동차 시트 리클라이너의 해석적 연구)

  • Lee, K.Y.;Do, J.Y.;Nam, K.W.
    • Journal of Power System Engineering
    • /
    • v.15 no.5
    • /
    • pp.67-71
    • /
    • 2011
  • Fine blanking is a specialized form of blanking where there is no fracture zone when shearing. This is achieved by compressing the whole part and then an upper and lower punch extract the blank. This allows the process to hold very tight tolerances, and perhaps eliminate secondary operations. In the present study, tensile test and numerical simulation has been performed to investigate distribution of deformation and stress of car seat recliner. The commercial ABAQUS/Explicit software was applied for analyzing the stress and strain of the recliner. In analysis, three lock gear has reached the maximum moment on rotational degree of 2.27. This is more than two times than maximum moment of same size recliner, and can be used safely. Therefore, these can use as criterion of actual structural design.

An Analysis of Flexural Performance of Concrete Filled Soldier Pile Applied to Temporary Retaining Wall (흙막이 벽체에 적용하는 콘크리트 충전형 엄지말뚝의 휨성능 분석)

  • Park, Yong-Hyeon;Kim, Do-Bumn;Ju, Young-Kyu;Yang, Il-Seung;Yom, Kyong-Soo
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.3
    • /
    • pp.19-25
    • /
    • 2019
  • The purpose of this study was to evaluate bending performance of concrete filled soldier pile for temporary retaining wall. Structural performance tests were conducted on total number of four specimens. Each specimen had a unique characteristics with combination of the following variables, existence of reinforcing bar and locations of reinforcing steel plates. The results of this study were as follows; concrete filled steel tubes with being reinforced bar and flange rather than non-bar showed better performance. Higher yield, tensile strength and sufficient plastic strain were archived and maximum moment observed in experiments exceeded theoretical maximum moment in both allowable stress design and limit state design at all specimens.

Development of Multi-Axis Force/Moment Sensor for Stroke Patient's Hand Fixing System Control (뇌졸중 환자의 손 고정장치 제어를 위한 다축 힘/모멘트센서 개발)

  • Kim, H.M.;Kim, J.W.;Kim, G.S.
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.351-356
    • /
    • 2011
  • Stroke patients should exercise for the rehabilitation of their fingers, because they can't use their hand and fingers. Their hand and fingers are fixed on the hand fixing system for rehabilitation exercise of them. But the hands clenched the fist of stroke patients are difficult to fix on it. In order to fix the hands and fingers, their palms are pressed with pressing bars and are controlled by reference force. The fixing system must have a five-axis force/moment sensor to force control. In this paper, the five-axis force/moment sensor was developed for the hand fixing system of finger-rehabilitation exercising system. The structure of the five-axis force/moment sensor was modeled, and designed using finite element method(FEM). And it was fabricated with strain-gages, then, its characteristic test was carried out. As a result, the maximum interference error is less than 2.43 %.

Seismic Performance and Design Process of a Ceiling Bracket-Typed Modular Connection (천장 브래킷형 모듈러 시스템의 접합부 내진 성능과 설계 프로세스)

  • Lee, Seungjae;Kang, Changhoon;Park, Jaeseong;Kwak, Euishin;Shon, Sudeok
    • Journal of Korean Association for Spatial Structures
    • /
    • v.20 no.3
    • /
    • pp.27-34
    • /
    • 2020
  • This paper examines the seismic performance and structural design of the ceiling bracket-type modular connection. The bracket-type system reduces the cross-sectional area loss of members and combines units using fitting steel plate, and it has been developed to be fit for medium-story and higher-story buildings. In particular, this study conducted the cyclic loading test for the performance of the C-type and L-type brackets, and compared the results. The test results were also compared with the commercial FEA program. In addition, the structural design process for the bracket-type modular connection was presented. The two connections, proposed as a result of the test results, were all found to secure the seismic performance level of the special moment steel frame. In the case of initial stiffness, the L-type bracket connection was found to be great, but in the case of the maximum moment or fully plastic moment, it was different depending on the loading direction.

Effective Punching Shear and Moment Capacity of Flat Plate-Column Connection with Shear Reinforcements for Lateral Loading

  • Song, Jin-Kyu;Kim, Ju-Bum;Song, Ho-Bum;Song, Jeong-Won
    • International Journal of Concrete Structures and Materials
    • /
    • v.6 no.1
    • /
    • pp.19-29
    • /
    • 2012
  • In this study, three isolated interior flat slab-column connections that include three types of shear reinforcement details; stirrup, shear stud and shear band were tested under reversed cyclic lateral loading to observe the capacity of slab-column connections. These reinforced joints are 2/3 scale miniatures designed to have identical punching capacities. These experiments showed that the flexural failure mode appears in most specimens while the maximum unbalanced moment and energy absorbing capacity increases effectively, with the exception of an unreinforced standard specimen. Finally, the results of the experiments, as wel l as those of experiments previously carried out by researchers, are applied to the eccentricity shear stress model presented in ACI 318-08. The failure mode is therefore defined in this study by considering the upper limits for punching shear and unbalanced moment. In addition, an intensity factor is proposed for effective widths of slabs that carry an unbalanced moment delivered by bending.